{"id":"https://openalex.org/W2021836563","doi":"https://doi.org/10.1109/mwscas.2012.6291987","title":"Evaluation of fault tolerant channel buffers for improving reliability in NoCs","display_name":"Evaluation of fault tolerant channel buffers for improving reliability in NoCs","publication_year":2012,"publication_date":"2012-08-01","ids":{"openalex":"https://openalex.org/W2021836563","doi":"https://doi.org/10.1109/mwscas.2012.6291987","mag":"2021836563"},"language":"en","primary_location":{"id":"doi:10.1109/mwscas.2012.6291987","is_oa":false,"landing_page_url":"https://doi.org/10.1109/mwscas.2012.6291987","pdf_url":null,"source":null,"license":null,"license_id":null,"version":"publishedVersion","is_accepted":true,"is_published":true,"raw_source_name":"2012 IEEE 55th International Midwest Symposium on Circuits and Systems (MWSCAS)","raw_type":"proceedings-article"},"type":"conference-paper","indexed_in":["crossref"],"open_access":{"is_oa":false,"oa_status":"closed","oa_url":null,"any_repository_has_fulltext":false},"authorships":[{"author_position":"first","author":{"id":"https://openalex.org/A5054786064","display_name":"Dominic DiTomaso","orcid":null},"institutions":[{"id":"https://openalex.org/I4210106879","display_name":"Ohio University","ror":"https://ror.org/01jr3y717","country_code":"US","type":"education","lineage":["https://openalex.org/I4210106879"]}],"countries":["US"],"is_corresponding":false,"raw_author_name":"Dominic DiTomaso","raw_affiliation_strings":["Electrical Engineering and Computer Science, Ohio University, Athens, OH, USA","Electrical Engineering and Computer Science, Ohio University, Athens, 45701, USA"],"raw_orcid":null,"affiliations":[{"raw_affiliation_string":"Electrical Engineering and Computer Science, Ohio University, Athens, OH, USA","institution_ids":["https://openalex.org/I4210106879"]},{"raw_affiliation_string":"Electrical Engineering and Computer Science, Ohio University, Athens, 45701, USA","institution_ids":["https://openalex.org/I4210106879"]}]},{"author_position":"middle","author":{"id":"https://openalex.org/A5070955932","display_name":"Travis Boraten","orcid":"https://orcid.org/0000-0002-1627-7069"},"institutions":[{"id":"https://openalex.org/I4210106879","display_name":"Ohio University","ror":"https://ror.org/01jr3y717","country_code":"US","type":"education","lineage":["https://openalex.org/I4210106879"]}],"countries":["US"],"is_corresponding":false,"raw_author_name":"Travis Boraten","raw_affiliation_strings":["Electrical Engineering and Computer Science, Ohio University, Athens, OH, USA","Electrical Engineering and Computer Science, Ohio University, Athens, 45701, USA"],"raw_orcid":null,"affiliations":[{"raw_affiliation_string":"Electrical Engineering and Computer Science, Ohio University, Athens, OH, USA","institution_ids":["https://openalex.org/I4210106879"]},{"raw_affiliation_string":"Electrical Engineering and Computer Science, Ohio University, Athens, 45701, USA","institution_ids":["https://openalex.org/I4210106879"]}]},{"author_position":"middle","author":{"id":null,"display_name":"Avinash Kodi","orcid":null},"institutions":[{"id":"https://openalex.org/I4210106879","display_name":"Ohio University","ror":"https://ror.org/01jr3y717","country_code":"US","type":"education","lineage":["https://openalex.org/I4210106879"]}],"countries":["US"],"is_corresponding":false,"raw_author_name":"Avinash Kodi","raw_affiliation_strings":["Electrical Engineering and Computer Science, Ohio University, Athens, OH, USA","Electrical Engineering and Computer Science, Ohio University, Athens, 45701, USA"],"raw_orcid":null,"affiliations":[{"raw_affiliation_string":"Electrical Engineering and Computer Science, Ohio University, Athens, OH, USA","institution_ids":["https://openalex.org/I4210106879"]},{"raw_affiliation_string":"Electrical Engineering and Computer Science, Ohio University, Athens, 45701, USA","institution_ids":["https://openalex.org/I4210106879"]}]},{"author_position":"last","author":{"id":"https://openalex.org/A5034189643","display_name":"Ahmed Louri","orcid":"https://orcid.org/0000-0003-4262-6688"},"institutions":[{"id":"https://openalex.org/I138006243","display_name":"University of Arizona","ror":"https://ror.org/03m2x1q45","country_code":"US","type":"education","lineage":["https://openalex.org/I138006243"]}],"countries":["US"],"is_corresponding":false,"raw_author_name":"Ahmed Louri","raw_affiliation_strings":["Electrical and Computer Engineering, University of Arizona Tucson, Tucson, AZ, USA","Electrical and Computer Engineering, University of Arizona, Tucson, 85721, USA#TAB#"],"raw_orcid":null,"affiliations":[{"raw_affiliation_string":"Electrical and Computer Engineering, University of Arizona Tucson, Tucson, AZ, USA","institution_ids":["https://openalex.org/I138006243"]},{"raw_affiliation_string":"Electrical and Computer Engineering, University of Arizona, Tucson, 85721, USA#TAB#","institution_ids":["https://openalex.org/I138006243"]}]}],"institutions":[],"countries_distinct_count":1,"institutions_distinct_count":2,"corresponding_author_ids":[],"corresponding_institution_ids":[],"apc_list":null,"apc_paid":null,"fwci":null,"has_fulltext":false,"cited_by_count":1,"citation_normalized_percentile":null,"cited_by_percentile_year":null,"biblio":{"volume":"39","issue":null,"first_page":"182","last_page":"185"},"is_retracted":false,"is_paratext":false,"is_xpac":false,"primary_topic":{"id":"https://openalex.org/T10829","display_name":"Interconnection Networks and Systems","score":1.0,"subfield":{"id":"https://openalex.org/subfields/1705","display_name":"Computer Networks and Communications"},"field":{"id":"https://openalex.org/fields/17","display_name":"Computer Science"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}},"topics":[{"id":"https://openalex.org/T10829","display_name":"Interconnection Networks and Systems","score":1.0,"subfield":{"id":"https://openalex.org/subfields/1705","display_name":"Computer Networks and Communications"},"field":{"id":"https://openalex.org/fields/17","display_name":"Computer Science"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}},{"id":"https://openalex.org/T10054","display_name":"Parallel Computing and Optimization Techniques","score":0.9961000084877014,"subfield":{"id":"https://openalex.org/subfields/1708","display_name":"Hardware and Architecture"},"field":{"id":"https://openalex.org/fields/17","display_name":"Computer Science"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}},{"id":"https://openalex.org/T10018","display_name":"Advancements in Battery Materials","score":0.9955999851226807,"subfield":{"id":"https://openalex.org/subfields/2208","display_name":"Electrical and Electronic Engineering"},"field":{"id":"https://openalex.org/fields/22","display_name":"Engineering"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}}],"keywords":[{"id":"https://openalex.org/keywords/computer-science","display_name":"Computer science","score":0.6708751320838928},{"id":"https://openalex.org/keywords/network-topology","display_name":"Network topology","score":0.654425323009491},{"id":"https://openalex.org/keywords/router","display_name":"Router","score":0.649712324142456},{"id":"https://openalex.org/keywords/fault-tolerance","display_name":"Fault tolerance","score":0.6144599914550781},{"id":"https://openalex.org/keywords/latency","display_name":"Latency (audio)","score":0.5451064705848694},{"id":"https://openalex.org/keywords/network-on-a-chip","display_name":"Network on a chip","score":0.5389429330825806},{"id":"https://openalex.org/keywords/embedded-system","display_name":"Embedded system","score":0.5141206383705139},{"id":"https://openalex.org/keywords/throughput","display_name":"Throughput","score":0.4507673382759094},{"id":"https://openalex.org/keywords/reliability","display_name":"Reliability (semiconductor)","score":0.4314265251159668},{"id":"https://openalex.org/keywords/ranging","display_name":"Ranging","score":0.4116145372390747},{"id":"https://openalex.org/keywords/topology","display_name":"Topology (electrical circuits)","score":0.3811088800430298},{"id":"https://openalex.org/keywords/computer-network","display_name":"Computer network","score":0.3027943968772888},{"id":"https://openalex.org/keywords/power","display_name":"Power (physics)","score":0.2687014937400818},{"id":"https://openalex.org/keywords/distributed-computing","display_name":"Distributed computing","score":0.25665295124053955},{"id":"https://openalex.org/keywords/engineering","display_name":"Engineering","score":0.2293386161327362},{"id":"https://openalex.org/keywords/wireless","display_name":"Wireless","score":0.10911703109741211},{"id":"https://openalex.org/keywords/electrical-engineering","display_name":"Electrical engineering","score":0.09626227617263794}],"concepts":[{"id":"https://openalex.org/C41008148","wikidata":"https://www.wikidata.org/wiki/Q21198","display_name":"Computer science","level":0,"score":0.6708751320838928},{"id":"https://openalex.org/C199845137","wikidata":"https://www.wikidata.org/wiki/Q145490","display_name":"Network topology","level":2,"score":0.654425323009491},{"id":"https://openalex.org/C2775896111","wikidata":"https://www.wikidata.org/wiki/Q642560","display_name":"Router","level":2,"score":0.649712324142456},{"id":"https://openalex.org/C63540848","wikidata":"https://www.wikidata.org/wiki/Q3140932","display_name":"Fault tolerance","level":2,"score":0.6144599914550781},{"id":"https://openalex.org/C82876162","wikidata":"https://www.wikidata.org/wiki/Q17096504","display_name":"Latency (audio)","level":2,"score":0.5451064705848694},{"id":"https://openalex.org/C128519102","wikidata":"https://www.wikidata.org/wiki/Q339554","display_name":"Network on a chip","level":2,"score":0.5389429330825806},{"id":"https://openalex.org/C149635348","wikidata":"https://www.wikidata.org/wiki/Q193040","display_name":"Embedded system","level":1,"score":0.5141206383705139},{"id":"https://openalex.org/C157764524","wikidata":"https://www.wikidata.org/wiki/Q1383412","display_name":"Throughput","level":3,"score":0.4507673382759094},{"id":"https://openalex.org/C43214815","wikidata":"https://www.wikidata.org/wiki/Q7310987","display_name":"Reliability (semiconductor)","level":3,"score":0.4314265251159668},{"id":"https://openalex.org/C115051666","wikidata":"https://www.wikidata.org/wiki/Q6522493","display_name":"Ranging","level":2,"score":0.4116145372390747},{"id":"https://openalex.org/C184720557","wikidata":"https://www.wikidata.org/wiki/Q7825049","display_name":"Topology (electrical circuits)","level":2,"score":0.3811088800430298},{"id":"https://openalex.org/C31258907","wikidata":"https://www.wikidata.org/wiki/Q1301371","display_name":"Computer network","level":1,"score":0.3027943968772888},{"id":"https://openalex.org/C163258240","wikidata":"https://www.wikidata.org/wiki/Q25342","display_name":"Power (physics)","level":2,"score":0.2687014937400818},{"id":"https://openalex.org/C120314980","wikidata":"https://www.wikidata.org/wiki/Q180634","display_name":"Distributed computing","level":1,"score":0.25665295124053955},{"id":"https://openalex.org/C127413603","wikidata":"https://www.wikidata.org/wiki/Q11023","display_name":"Engineering","level":0,"score":0.2293386161327362},{"id":"https://openalex.org/C555944384","wikidata":"https://www.wikidata.org/wiki/Q249","display_name":"Wireless","level":2,"score":0.10911703109741211},{"id":"https://openalex.org/C119599485","wikidata":"https://www.wikidata.org/wiki/Q43035","display_name":"Electrical engineering","level":1,"score":0.09626227617263794},{"id":"https://openalex.org/C121332964","wikidata":"https://www.wikidata.org/wiki/Q413","display_name":"Physics","level":0,"score":0.0},{"id":"https://openalex.org/C62520636","wikidata":"https://www.wikidata.org/wiki/Q944","display_name":"Quantum mechanics","level":1,"score":0.0},{"id":"https://openalex.org/C76155785","wikidata":"https://www.wikidata.org/wiki/Q418","display_name":"Telecommunications","level":1,"score":0.0}],"mesh":[],"locations_count":1,"locations":[{"id":"doi:10.1109/mwscas.2012.6291987","is_oa":false,"landing_page_url":"https://doi.org/10.1109/mwscas.2012.6291987","pdf_url":null,"source":null,"license":null,"license_id":null,"version":"publishedVersion","is_accepted":true,"is_published":true,"raw_source_name":"2012 IEEE 55th International Midwest Symposium on Circuits and Systems (MWSCAS)","raw_type":"proceedings-article"}],"best_oa_location":null,"sustainable_development_goals":[{"id":"https://metadata.un.org/sdg/7","score":0.8999999761581421,"display_name":"Affordable and clean energy"}],"awards":[],"funders":[{"id":"https://openalex.org/F4320306076","display_name":"National Science Foundation","ror":"https://ror.org/021nxhr62"},{"id":"https://openalex.org/F4320337392","display_name":"Division of Electrical, Communications and Cyber Systems","ror":"https://ror.org/01krpsy48"}],"has_content":{"pdf":false,"grobid_xml":false},"content_urls":null,"referenced_works_count":11,"referenced_works":["https://openalex.org/W2008984813","https://openalex.org/W2021625815","https://openalex.org/W2025177582","https://openalex.org/W2071552002","https://openalex.org/W2085581890","https://openalex.org/W2114522727","https://openalex.org/W2158382658","https://openalex.org/W2160642395","https://openalex.org/W3140261852","https://openalex.org/W4241149914","https://openalex.org/W6668538802"],"related_works":["https://openalex.org/W2052816277","https://openalex.org/W2167988973","https://openalex.org/W2603824091","https://openalex.org/W2560886726","https://openalex.org/W2091258882","https://openalex.org/W2541438272","https://openalex.org/W2013729863","https://openalex.org/W3006485811","https://openalex.org/W2510977931","https://openalex.org/W2181632526"],"abstract_inverted_index":{"Elastic":[0],"or":[1,18],"channel":[2,36],"buffers":[3,37],"can":[4],"improve":[5,52],"the":[6,67],"overall":[7,97],"power":[8,21,49],"and":[9,51,54,71,94],"area":[10,100],"overhead":[11,101],"of":[12,92],"Network-on-Chip":[13],"(NoC)":[14],"architectures":[15],"by":[16,102],"reducing":[17],"replacing":[19],"large,":[20],"hungry":[22],"router":[23],"buffers.":[24],"In":[25],"this":[26],"paper,":[27],"we":[28],"design":[29],"three":[30],"fault":[31,58],"tolerant":[32,59],"schemes":[33],"for":[34],"our":[35,72],"which":[38],"are":[39,64],"used":[40],"in":[41,78,89,99],"a":[42],"concentrated":[43],"torus":[44],"(CTorus)":[45],"topology":[46,63],"to":[47,85],"reduce":[48],"consumption":[50],"throughput":[53,91],"latency.":[55],"Our":[56],"proposed":[57],"techniques":[60],"on":[61],"CTorus":[62],"evaluated":[65],"using":[66],"Synopsys":[68],"Design":[69],"Compiler":[70],"results":[73],"show":[74],"(i)":[75],"an":[76,96],"improvement":[77,88],"energy-delay":[79],"product":[80],"(EDP)":[81],"ranging":[82],"from":[83],"20%":[84],"43%,":[86],"(ii)":[87],"saturation":[90],"32%":[93],"(iii)":[95],"reduction":[98],"53-68%":[103],"over":[104],"other":[105],"state-of-the-art":[106],"electrical":[107],"topologies.":[108]},"counts_by_year":[{"year":2014,"cited_by_count":1}],"updated_date":"2026-07-21T08:15:58.654021","created_date":"2025-10-10T00:00:00"}
