{"id":"https://openalex.org/W2756846406","doi":"https://doi.org/10.1109/mmar.2017.8046955","title":"Simultaneous estimation of multiple actuator anc sensor faults for Takagi-Sugeno fuzzy systems","display_name":"Simultaneous estimation of multiple actuator anc sensor faults for Takagi-Sugeno fuzzy systems","publication_year":2017,"publication_date":"2017-08-01","ids":{"openalex":"https://openalex.org/W2756846406","doi":"https://doi.org/10.1109/mmar.2017.8046955","mag":"2756846406"},"language":"en","primary_location":{"id":"doi:10.1109/mmar.2017.8046955","is_oa":false,"landing_page_url":"https://doi.org/10.1109/mmar.2017.8046955","pdf_url":null,"source":null,"license":null,"license_id":null,"version":"publishedVersion","is_accepted":true,"is_published":true,"raw_source_name":"2017 22nd International Conference on Methods and Models in Automation and Robotics (MMAR)","raw_type":"proceedings-article"},"type":"conference-paper","indexed_in":["crossref"],"open_access":{"is_oa":false,"oa_status":"closed","oa_url":null,"any_repository_has_fulltext":false},"authorships":[{"author_position":"first","author":{"id":"https://openalex.org/A5013565304","display_name":"Marcin Pazera","orcid":"https://orcid.org/0000-0003-2469-7570"},"institutions":[{"id":"https://openalex.org/I46305939","display_name":"University of Zielona G\u00f3ra","ror":"https://ror.org/04fzm7v55","country_code":"PL","type":"education","lineage":["https://openalex.org/I46305939"]}],"countries":["PL"],"is_corresponding":false,"raw_author_name":"Marcin Pazera","raw_affiliation_strings":["Institute of Control and Computation Engineering, University of Zielona G\u00f3ra, Zielona G\u00f3ra, Poland"],"raw_orcid":null,"affiliations":[{"raw_affiliation_string":"Institute of Control and Computation Engineering, University of Zielona G\u00f3ra, Zielona G\u00f3ra, Poland","institution_ids":["https://openalex.org/I46305939"]}]},{"author_position":"middle","author":{"id":"https://openalex.org/A5038922169","display_name":"Marcin Witczak","orcid":"https://orcid.org/0000-0002-0031-0004"},"institutions":[{"id":"https://openalex.org/I46305939","display_name":"University of Zielona G\u00f3ra","ror":"https://ror.org/04fzm7v55","country_code":"PL","type":"education","lineage":["https://openalex.org/I46305939"]}],"countries":["PL"],"is_corresponding":false,"raw_author_name":"Marcin Witczak","raw_affiliation_strings":["Institute of Control and Computation Engineering, University of Zielona G\u00f3ra, Zielona G\u00f3ra, Poland"],"raw_orcid":null,"affiliations":[{"raw_affiliation_string":"Institute of Control and Computation Engineering, University of Zielona G\u00f3ra, Zielona G\u00f3ra, Poland","institution_ids":["https://openalex.org/I46305939"]}]},{"author_position":"middle","author":{"id":"https://openalex.org/A5024236530","display_name":"Mariusz Buciakowski","orcid":"https://orcid.org/0000-0002-0801-0145"},"institutions":[{"id":"https://openalex.org/I46305939","display_name":"University of Zielona G\u00f3ra","ror":"https://ror.org/04fzm7v55","country_code":"PL","type":"education","lineage":["https://openalex.org/I46305939"]}],"countries":["PL"],"is_corresponding":false,"raw_author_name":"Mariusz Buciakowski","raw_affiliation_strings":["Institute of Control and Computation Engineering, University of Zielona G\u00f3ra, Zielona G\u00f3ra, Poland"],"raw_orcid":null,"affiliations":[{"raw_affiliation_string":"Institute of Control and Computation Engineering, University of Zielona G\u00f3ra, Zielona G\u00f3ra, Poland","institution_ids":["https://openalex.org/I46305939"]}]},{"author_position":"last","author":{"id":"https://openalex.org/A5018349793","display_name":"Marcin Mrugalski","orcid":"https://orcid.org/0000-0003-3078-411X"},"institutions":[{"id":"https://openalex.org/I46305939","display_name":"University of Zielona G\u00f3ra","ror":"https://ror.org/04fzm7v55","country_code":"PL","type":"education","lineage":["https://openalex.org/I46305939"]}],"countries":["PL"],"is_corresponding":false,"raw_author_name":"Marcin Mrugalski","raw_affiliation_strings":["Institute of Control and Computation Engineering, University of Zielona G\u00f3ra, Zielona G\u00f3ra, Poland"],"raw_orcid":null,"affiliations":[{"raw_affiliation_string":"Institute of Control and Computation Engineering, University of Zielona G\u00f3ra, Zielona G\u00f3ra, Poland","institution_ids":["https://openalex.org/I46305939"]}]}],"institutions":[],"countries_distinct_count":1,"institutions_distinct_count":1,"corresponding_author_ids":[],"corresponding_institution_ids":["https://openalex.org/I46305939"],"apc_list":null,"apc_paid":null,"fwci":1.3244,"has_fulltext":false,"cited_by_count":5,"citation_normalized_percentile":{"value":0.76433599,"is_in_top_1_percent":false,"is_in_top_10_percent":false},"cited_by_percentile_year":{"min":89,"max":97},"biblio":{"volume":"13","issue":null,"first_page":"939","last_page":"944"},"is_retracted":false,"is_paratext":false,"is_xpac":false,"primary_topic":{"id":"https://openalex.org/T10876","display_name":"Fault Detection and Control Systems","score":0.9998999834060669,"subfield":{"id":"https://openalex.org/subfields/2207","display_name":"Control and Systems Engineering"},"field":{"id":"https://openalex.org/fields/22","display_name":"Engineering"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}},"topics":[{"id":"https://openalex.org/T10876","display_name":"Fault Detection and Control Systems","score":0.9998999834060669,"subfield":{"id":"https://openalex.org/subfields/2207","display_name":"Control and Systems Engineering"},"field":{"id":"https://openalex.org/fields/22","display_name":"Engineering"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}},{"id":"https://openalex.org/T10820","display_name":"Fuzzy Logic and Control Systems","score":0.9993000030517578,"subfield":{"id":"https://openalex.org/subfields/1702","display_name":"Artificial Intelligence"},"field":{"id":"https://openalex.org/fields/17","display_name":"Computer Science"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}},{"id":"https://openalex.org/T11236","display_name":"Control Systems and Identification","score":0.9947999715805054,"subfield":{"id":"https://openalex.org/subfields/2207","display_name":"Control and Systems Engineering"},"field":{"id":"https://openalex.org/fields/22","display_name":"Engineering"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}}],"keywords":[{"id":"https://openalex.org/keywords/estimator","display_name":"Estimator","score":0.7704423666000366},{"id":"https://openalex.org/keywords/actuator","display_name":"Actuator","score":0.7375799417495728},{"id":"https://openalex.org/keywords/computer-science","display_name":"Computer science","score":0.5875222682952881},{"id":"https://openalex.org/keywords/control-theory","display_name":"Control theory (sociology)","score":0.5468050241470337},{"id":"https://openalex.org/keywords/fault","display_name":"Fault (geology)","score":0.5189871191978455},{"id":"https://openalex.org/keywords/convergence","display_name":"Convergence (economics)","score":0.504988968372345},{"id":"https://openalex.org/keywords/fault-detection-and-isolation","display_name":"Fault detection and isolation","score":0.4659496247768402},{"id":"https://openalex.org/keywords/fuzzy-logic","display_name":"Fuzzy logic","score":0.45306310057640076},{"id":"https://openalex.org/keywords/control-engineering","display_name":"Control engineering","score":0.4459637701511383},{"id":"https://openalex.org/keywords/engineering","display_name":"Engineering","score":0.2683264911174774},{"id":"https://openalex.org/keywords/artificial-intelligence","display_name":"Artificial intelligence","score":0.2591254711151123},{"id":"https://openalex.org/keywords/mathematics","display_name":"Mathematics","score":0.18509382009506226},{"id":"https://openalex.org/keywords/control","display_name":"Control (management)","score":0.08687853813171387}],"concepts":[{"id":"https://openalex.org/C185429906","wikidata":"https://www.wikidata.org/wiki/Q1130160","display_name":"Estimator","level":2,"score":0.7704423666000366},{"id":"https://openalex.org/C172707124","wikidata":"https://www.wikidata.org/wiki/Q423488","display_name":"Actuator","level":2,"score":0.7375799417495728},{"id":"https://openalex.org/C41008148","wikidata":"https://www.wikidata.org/wiki/Q21198","display_name":"Computer science","level":0,"score":0.5875222682952881},{"id":"https://openalex.org/C47446073","wikidata":"https://www.wikidata.org/wiki/Q5165890","display_name":"Control theory (sociology)","level":3,"score":0.5468050241470337},{"id":"https://openalex.org/C175551986","wikidata":"https://www.wikidata.org/wiki/Q47089","display_name":"Fault (geology)","level":2,"score":0.5189871191978455},{"id":"https://openalex.org/C2777303404","wikidata":"https://www.wikidata.org/wiki/Q759757","display_name":"Convergence (economics)","level":2,"score":0.504988968372345},{"id":"https://openalex.org/C152745839","wikidata":"https://www.wikidata.org/wiki/Q5438153","display_name":"Fault detection and isolation","level":3,"score":0.4659496247768402},{"id":"https://openalex.org/C58166","wikidata":"https://www.wikidata.org/wiki/Q224821","display_name":"Fuzzy logic","level":2,"score":0.45306310057640076},{"id":"https://openalex.org/C133731056","wikidata":"https://www.wikidata.org/wiki/Q4917288","display_name":"Control engineering","level":1,"score":0.4459637701511383},{"id":"https://openalex.org/C127413603","wikidata":"https://www.wikidata.org/wiki/Q11023","display_name":"Engineering","level":0,"score":0.2683264911174774},{"id":"https://openalex.org/C154945302","wikidata":"https://www.wikidata.org/wiki/Q11660","display_name":"Artificial intelligence","level":1,"score":0.2591254711151123},{"id":"https://openalex.org/C33923547","wikidata":"https://www.wikidata.org/wiki/Q395","display_name":"Mathematics","level":0,"score":0.18509382009506226},{"id":"https://openalex.org/C2775924081","wikidata":"https://www.wikidata.org/wiki/Q55608371","display_name":"Control (management)","level":2,"score":0.08687853813171387},{"id":"https://openalex.org/C105795698","wikidata":"https://www.wikidata.org/wiki/Q12483","display_name":"Statistics","level":1,"score":0.0},{"id":"https://openalex.org/C127313418","wikidata":"https://www.wikidata.org/wiki/Q1069","display_name":"Geology","level":0,"score":0.0},{"id":"https://openalex.org/C165205528","wikidata":"https://www.wikidata.org/wiki/Q83371","display_name":"Seismology","level":1,"score":0.0},{"id":"https://openalex.org/C162324750","wikidata":"https://www.wikidata.org/wiki/Q8134","display_name":"Economics","level":0,"score":0.0},{"id":"https://openalex.org/C50522688","wikidata":"https://www.wikidata.org/wiki/Q189833","display_name":"Economic growth","level":1,"score":0.0}],"mesh":[],"locations_count":1,"locations":[{"id":"doi:10.1109/mmar.2017.8046955","is_oa":false,"landing_page_url":"https://doi.org/10.1109/mmar.2017.8046955","pdf_url":null,"source":null,"license":null,"license_id":null,"version":"publishedVersion","is_accepted":true,"is_published":true,"raw_source_name":"2017 22nd International Conference on Methods and Models in Automation and Robotics (MMAR)","raw_type":"proceedings-article"}],"best_oa_location":null,"sustainable_development_goals":[],"awards":[],"funders":[{"id":"https://openalex.org/F4320322650","display_name":"Narodowym Centrum Nauki","ror":"https://ror.org/03ha2q922"}],"has_content":{"pdf":false,"grobid_xml":false},"content_urls":null,"referenced_works_count":41,"referenced_works":["https://openalex.org/W127587312","https://openalex.org/W224240778","https://openalex.org/W619893528","https://openalex.org/W1491231144","https://openalex.org/W1509358801","https://openalex.org/W1566387820","https://openalex.org/W1585152006","https://openalex.org/W1633664367","https://openalex.org/W1788576935","https://openalex.org/W1854607770","https://openalex.org/W1985690966","https://openalex.org/W2020774607","https://openalex.org/W2039130051","https://openalex.org/W2040049254","https://openalex.org/W2042741865","https://openalex.org/W2044861271","https://openalex.org/W2052562583","https://openalex.org/W2064007681","https://openalex.org/W2064815138","https://openalex.org/W2068167285","https://openalex.org/W2068192622","https://openalex.org/W2079325629","https://openalex.org/W2081341054","https://openalex.org/W2103509780","https://openalex.org/W2116349459","https://openalex.org/W2121908804","https://openalex.org/W2128511080","https://openalex.org/W2146920625","https://openalex.org/W2148885430","https://openalex.org/W2151367048","https://openalex.org/W2153094178","https://openalex.org/W2168568021","https://openalex.org/W2206118737","https://openalex.org/W2263516000","https://openalex.org/W2371435256","https://openalex.org/W2396963557","https://openalex.org/W2406095378","https://openalex.org/W2504218592","https://openalex.org/W2604556401","https://openalex.org/W3146551586","https://openalex.org/W4230460640"],"related_works":["https://openalex.org/W4287880334","https://openalex.org/W4366700029","https://openalex.org/W4285230481","https://openalex.org/W4385769873","https://openalex.org/W4281634296","https://openalex.org/W4319161863","https://openalex.org/W2371687270","https://openalex.org/W4311888330","https://openalex.org/W2517641583","https://openalex.org/W4221071877"],"abstract_inverted_index":{"The":[0,29,43,60,75],"paper":[1,80],"is":[2,38,49],"devoted":[3],"to":[4],"the":[5,19,22,47,72,79,85,88,92,95,99],"problem":[6],"of":[7,21,26,32,46,53,71,78,84,87,94,98],"a":[8,34,64],"Takagi-Sugeno(TS)-based":[9],"robust":[10],"simultaneous":[11,54],"actuator":[12,57],"and":[13,56,69],"sensor":[14,55],"faults":[15,58],"estimator":[16,37],"design":[17],"for":[18],"purpose":[20],"Fault":[23],"Diagnosis":[24],"(FD)":[25],"non-linear":[27],"systems.":[28],"proposed":[30],"methodology":[31],"designing":[33],"TS-based":[35],"H\u221efault":[36],"developed":[39,61,89],"in":[40,91],"this":[41],"paper.":[42],"main":[44],"novelty":[45],"approach":[48,62,90],"associated":[50],"with":[51],"possibly":[52],"estimation.":[59],"guaranties":[63],"predefined":[65],"disturbance":[66],"attenuation":[67],"level":[68],"convergence":[70],"designed":[73],"estimator.":[74],"illustrative":[76],"part":[77],"shows":[81],"an":[82],"example":[83],"application":[86],"task":[93],"fault":[96],"diagnosis":[97],"multi-tank":[100],"system.":[101]},"counts_by_year":[{"year":2024,"cited_by_count":1},{"year":2022,"cited_by_count":1},{"year":2019,"cited_by_count":3}],"updated_date":"2026-07-29T14:22:42.915294","created_date":"2025-10-10T00:00:00"}
