{"id":"https://openalex.org/W1639208179","doi":"https://doi.org/10.1109/mmar.2015.7283943","title":"Predictive functional control of dissolved oxygen with online estimation of oxygene uptake rate","display_name":"Predictive functional control of dissolved oxygen with online estimation of oxygene uptake rate","publication_year":2015,"publication_date":"2015-08-01","ids":{"openalex":"https://openalex.org/W1639208179","doi":"https://doi.org/10.1109/mmar.2015.7283943","mag":"1639208179"},"language":"en","primary_location":{"id":"doi:10.1109/mmar.2015.7283943","is_oa":false,"landing_page_url":"https://doi.org/10.1109/mmar.2015.7283943","pdf_url":null,"source":null,"license":null,"license_id":null,"version":"publishedVersion","is_accepted":true,"is_published":true,"raw_source_name":"2015 20th International Conference on Methods and Models in Automation and Robotics (MMAR)","raw_type":"proceedings-article"},"type":"article","indexed_in":["crossref"],"open_access":{"is_oa":false,"oa_status":"closed","oa_url":null,"any_repository_has_fulltext":false},"authorships":[{"author_position":"first","author":{"id":"https://openalex.org/A5003090944","display_name":"Piotr \u0141aszczyk","orcid":"https://orcid.org/0000-0001-5655-7818"},"institutions":[{"id":"https://openalex.org/I119004910","display_name":"Silesian University of Technology","ror":"https://ror.org/02dyjk442","country_code":"PL","type":"education","lineage":["https://openalex.org/I119004910"]}],"countries":["PL"],"is_corresponding":true,"raw_author_name":"Piotr Laszczyk","raw_affiliation_strings":["Institute of Automatic Control, Silesian University of Technology, Gliwice, Poland"],"affiliations":[{"raw_affiliation_string":"Institute of Automatic Control, Silesian University of Technology, Gliwice, Poland","institution_ids":["https://openalex.org/I119004910"]}]}],"institutions":[],"countries_distinct_count":1,"institutions_distinct_count":1,"corresponding_author_ids":["https://openalex.org/A5003090944"],"corresponding_institution_ids":["https://openalex.org/I119004910"],"apc_list":null,"apc_paid":null,"fwci":0.0,"has_fulltext":false,"cited_by_count":0,"citation_normalized_percentile":{"value":0.04375394,"is_in_top_1_percent":false,"is_in_top_10_percent":false},"cited_by_percentile_year":null,"biblio":{"volume":"48","issue":null,"first_page":"602","last_page":"607"},"is_retracted":false,"is_paratext":false,"is_xpac":false,"primary_topic":{"id":"https://openalex.org/T10791","display_name":"Advanced Control Systems Optimization","score":0.9998000264167786,"subfield":{"id":"https://openalex.org/subfields/2207","display_name":"Control and Systems Engineering"},"field":{"id":"https://openalex.org/fields/22","display_name":"Engineering"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}},"topics":[{"id":"https://openalex.org/T10791","display_name":"Advanced Control Systems Optimization","score":0.9998000264167786,"subfield":{"id":"https://openalex.org/subfields/2207","display_name":"Control and Systems Engineering"},"field":{"id":"https://openalex.org/fields/22","display_name":"Engineering"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}},{"id":"https://openalex.org/T10876","display_name":"Fault Detection and Control Systems","score":0.9955999851226807,"subfield":{"id":"https://openalex.org/subfields/2207","display_name":"Control and Systems Engineering"},"field":{"id":"https://openalex.org/fields/22","display_name":"Engineering"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}},{"id":"https://openalex.org/T10564","display_name":"Wastewater Treatment and Nitrogen Removal","score":0.9943000078201294,"subfield":{"id":"https://openalex.org/subfields/2310","display_name":"Pollution"},"field":{"id":"https://openalex.org/fields/23","display_name":"Environmental Science"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}}],"keywords":[{"id":"https://openalex.org/keywords/oxygen","display_name":"Oxygen","score":0.7432951927185059},{"id":"https://openalex.org/keywords/bioreactor","display_name":"Bioreactor","score":0.6108413934707642},{"id":"https://openalex.org/keywords/sewage-treatment","display_name":"Sewage treatment","score":0.5554446578025818},{"id":"https://openalex.org/keywords/limiting-oxygen-concentration","display_name":"Limiting oxygen concentration","score":0.5520492196083069},{"id":"https://openalex.org/keywords/wastewater","display_name":"Wastewater","score":0.5084113478660583},{"id":"https://openalex.org/keywords/control-theory","display_name":"Control theory (sociology)","score":0.48871850967407227},{"id":"https://openalex.org/keywords/feedback-control","display_name":"Feedback control","score":0.46906065940856934},{"id":"https://openalex.org/keywords/oxygen-sensor","display_name":"Oxygen sensor","score":0.44561389088630676},{"id":"https://openalex.org/keywords/activated-sludge","display_name":"Activated sludge","score":0.43938297033309937},{"id":"https://openalex.org/keywords/model-predictive-control","display_name":"Model predictive control","score":0.4324409067630768},{"id":"https://openalex.org/keywords/volumetric-flow-rate","display_name":"Volumetric flow rate","score":0.41986721754074097},{"id":"https://openalex.org/keywords/chemistry","display_name":"Chemistry","score":0.40434664487838745},{"id":"https://openalex.org/keywords/environmental-science","display_name":"Environmental science","score":0.29834306240081787},{"id":"https://openalex.org/keywords/environmental-engineering","display_name":"Environmental engineering","score":0.28860709071159363},{"id":"https://openalex.org/keywords/computer-science","display_name":"Computer science","score":0.2381085753440857},{"id":"https://openalex.org/keywords/thermodynamics","display_name":"Thermodynamics","score":0.20687541365623474},{"id":"https://openalex.org/keywords/control-engineering","display_name":"Control engineering","score":0.19827181100845337},{"id":"https://openalex.org/keywords/control","display_name":"Control (management)","score":0.19320490956306458},{"id":"https://openalex.org/keywords/engineering","display_name":"Engineering","score":0.1527816355228424},{"id":"https://openalex.org/keywords/physics","display_name":"Physics","score":0.07790890336036682}],"concepts":[{"id":"https://openalex.org/C540031477","wikidata":"https://www.wikidata.org/wiki/Q629","display_name":"Oxygen","level":2,"score":0.7432951927185059},{"id":"https://openalex.org/C168170006","wikidata":"https://www.wikidata.org/wiki/Q864699","display_name":"Bioreactor","level":2,"score":0.6108413934707642},{"id":"https://openalex.org/C57442070","wikidata":"https://www.wikidata.org/wiki/Q221275","display_name":"Sewage treatment","level":2,"score":0.5554446578025818},{"id":"https://openalex.org/C89169090","wikidata":"https://www.wikidata.org/wiki/Q593204","display_name":"Limiting oxygen concentration","level":3,"score":0.5520492196083069},{"id":"https://openalex.org/C94061648","wikidata":"https://www.wikidata.org/wiki/Q336191","display_name":"Wastewater","level":2,"score":0.5084113478660583},{"id":"https://openalex.org/C47446073","wikidata":"https://www.wikidata.org/wiki/Q5165890","display_name":"Control theory (sociology)","level":3,"score":0.48871850967407227},{"id":"https://openalex.org/C3018651601","wikidata":"https://www.wikidata.org/wiki/Q183635","display_name":"Feedback control","level":2,"score":0.46906065940856934},{"id":"https://openalex.org/C17734536","wikidata":"https://www.wikidata.org/wiki/Q286588","display_name":"Oxygen sensor","level":3,"score":0.44561389088630676},{"id":"https://openalex.org/C2777730692","wikidata":"https://www.wikidata.org/wiki/Q815353","display_name":"Activated sludge","level":3,"score":0.43938297033309937},{"id":"https://openalex.org/C172205157","wikidata":"https://www.wikidata.org/wiki/Q1782962","display_name":"Model predictive control","level":3,"score":0.4324409067630768},{"id":"https://openalex.org/C172120300","wikidata":"https://www.wikidata.org/wiki/Q1134348","display_name":"Volumetric flow rate","level":2,"score":0.41986721754074097},{"id":"https://openalex.org/C185592680","wikidata":"https://www.wikidata.org/wiki/Q2329","display_name":"Chemistry","level":0,"score":0.40434664487838745},{"id":"https://openalex.org/C39432304","wikidata":"https://www.wikidata.org/wiki/Q188847","display_name":"Environmental science","level":0,"score":0.29834306240081787},{"id":"https://openalex.org/C87717796","wikidata":"https://www.wikidata.org/wiki/Q146326","display_name":"Environmental engineering","level":1,"score":0.28860709071159363},{"id":"https://openalex.org/C41008148","wikidata":"https://www.wikidata.org/wiki/Q21198","display_name":"Computer science","level":0,"score":0.2381085753440857},{"id":"https://openalex.org/C97355855","wikidata":"https://www.wikidata.org/wiki/Q11473","display_name":"Thermodynamics","level":1,"score":0.20687541365623474},{"id":"https://openalex.org/C133731056","wikidata":"https://www.wikidata.org/wiki/Q4917288","display_name":"Control engineering","level":1,"score":0.19827181100845337},{"id":"https://openalex.org/C2775924081","wikidata":"https://www.wikidata.org/wiki/Q55608371","display_name":"Control (management)","level":2,"score":0.19320490956306458},{"id":"https://openalex.org/C127413603","wikidata":"https://www.wikidata.org/wiki/Q11023","display_name":"Engineering","level":0,"score":0.1527816355228424},{"id":"https://openalex.org/C121332964","wikidata":"https://www.wikidata.org/wiki/Q413","display_name":"Physics","level":0,"score":0.07790890336036682},{"id":"https://openalex.org/C154945302","wikidata":"https://www.wikidata.org/wiki/Q11660","display_name":"Artificial intelligence","level":1,"score":0.0},{"id":"https://openalex.org/C178790620","wikidata":"https://www.wikidata.org/wiki/Q11351","display_name":"Organic chemistry","level":1,"score":0.0}],"mesh":[],"locations_count":1,"locations":[{"id":"doi:10.1109/mmar.2015.7283943","is_oa":false,"landing_page_url":"https://doi.org/10.1109/mmar.2015.7283943","pdf_url":null,"source":null,"license":null,"license_id":null,"version":"publishedVersion","is_accepted":true,"is_published":true,"raw_source_name":"2015 20th International Conference on Methods and Models in Automation and Robotics (MMAR)","raw_type":"proceedings-article"}],"best_oa_location":null,"sustainable_development_goals":[{"score":0.8700000047683716,"id":"https://metadata.un.org/sdg/6","display_name":"Clean water and sanitation"}],"awards":[],"funders":[],"has_content":{"pdf":false,"grobid_xml":false},"content_urls":null,"referenced_works_count":26,"referenced_works":["https://openalex.org/W67341124","https://openalex.org/W296363114","https://openalex.org/W1593601104","https://openalex.org/W1642027243","https://openalex.org/W1967441290","https://openalex.org/W1999734856","https://openalex.org/W2006352352","https://openalex.org/W2009305466","https://openalex.org/W2015468649","https://openalex.org/W2015692069","https://openalex.org/W2038517185","https://openalex.org/W2074487159","https://openalex.org/W2074731840","https://openalex.org/W2082024984","https://openalex.org/W2092099260","https://openalex.org/W2095068859","https://openalex.org/W2143493317","https://openalex.org/W2414616884","https://openalex.org/W2415980832","https://openalex.org/W2496685523","https://openalex.org/W2617877710","https://openalex.org/W6636704881","https://openalex.org/W6654650406","https://openalex.org/W6715969046","https://openalex.org/W6716346364","https://openalex.org/W6738510061"],"related_works":["https://openalex.org/W2064864436","https://openalex.org/W2012890259","https://openalex.org/W915682155","https://openalex.org/W2392713276","https://openalex.org/W2380807943","https://openalex.org/W4386066012","https://openalex.org/W37553110","https://openalex.org/W4206119653","https://openalex.org/W587107261","https://openalex.org/W2157107170"],"abstract_inverted_index":{"Presented":[0],"research":[1],"relates":[2],"to":[3],"control":[4,44,71],"of":[5,40,83,90,113,120],"dissolved":[6,75],"oxygen":[7,20,32,49,76,105,114],"in":[8,78,104,108],"a":[9,14,38,68,88],"bioreactor.":[10],"There":[11],"were":[12,46,61],"assumed":[13,36],"nonlinear":[15],"relation":[16],"between":[17],"the":[18,27,30,84,95],"volumetric":[19,31],"transfer":[21,33],"coefficient":[22,34],"and":[23,53,66,107],"air":[24],"flow":[25],"into":[26],"reactor.":[28],"Thus":[29,116],"was":[35,128],"as":[37,67],"substitute":[39],"manipulated":[41],"value.":[42],"Two":[43],"algorithms":[45,60],"considered":[47],"for":[48,73,117],"stabilization:":[50],"classical":[51],"PI":[52],"model":[54,121],"predictive":[55],"one":[56],"-":[57],"PFC.":[58],"Both":[59],"tested":[62],"with":[63],"simulated":[64],"plant":[65],"conclusion":[69],"selective":[70],"concept":[72],"stabilizing":[74],"concentration":[77],"bioreactor":[79],"is":[80,87],"proposed.":[81],"One":[82],"strongest":[85],"disturbances":[86],"change":[89,101],"nutrients":[91],"load,":[92],"while":[93],"considering":[94],"wastewater":[96],"treatment":[97],"activated":[98],"sludge.":[99],"That":[100],"causes":[102],"variations":[103],"consumption":[106],"result":[109],"destabilizes":[110],"desired":[111],"level":[112],"concentration.":[115],"correct":[118],"performance":[119],"base":[122],"controller,":[123],"an":[124],"estimation":[125],"on-line":[126],"procedure":[127],"applied.":[129]},"counts_by_year":[],"updated_date":"2025-11-06T03:46:38.306776","created_date":"2025-10-10T00:00:00"}
