{"id":"https://openalex.org/W7114913857","doi":"https://doi.org/10.1109/mim.2025.11224806","title":"A Rapid Temperature Rise Testing Scheme and Device for Low-Voltage Switchgear","display_name":"A Rapid Temperature Rise Testing Scheme and Device for Low-Voltage Switchgear","publication_year":2025,"publication_date":"2025-12-12","ids":{"openalex":"https://openalex.org/W7114913857","doi":"https://doi.org/10.1109/mim.2025.11224806"},"language":null,"primary_location":{"id":"doi:10.1109/mim.2025.11224806","is_oa":false,"landing_page_url":"https://doi.org/10.1109/mim.2025.11224806","pdf_url":null,"source":{"id":"https://openalex.org/S121167460","display_name":"IEEE Instrumentation & Measurement Magazine","issn_l":"1094-6969","issn":["1094-6969","1941-0123"],"is_oa":false,"is_in_doaj":false,"is_core":true,"host_organization":"https://openalex.org/P4310319808","host_organization_name":"Institute of Electrical and Electronics Engineers","host_organization_lineage":["https://openalex.org/P4310319808"],"host_organization_lineage_names":["Institute of Electrical and Electronics Engineers"],"type":"journal"},"license":null,"license_id":null,"version":"publishedVersion","is_accepted":true,"is_published":true,"raw_source_name":"IEEE Instrumentation &amp; Measurement Magazine","raw_type":"journal-article"},"type":"article","indexed_in":["crossref"],"open_access":{"is_oa":false,"oa_status":"closed","oa_url":null,"any_repository_has_fulltext":false},"authorships":[{"author_position":"first","author":{"id":null,"display_name":"Bin Xiang","orcid":null},"institutions":[],"countries":[],"is_corresponding":false,"raw_author_name":"Bin Xiang","raw_affiliation_strings":["State Grid Hubei Electric Power Co"],"raw_orcid":null,"affiliations":[{"raw_affiliation_string":"State Grid Hubei Electric Power Co","institution_ids":[]}]},{"author_position":"middle","author":{"id":null,"display_name":"Hu Xiong","orcid":null},"institutions":[],"countries":[],"is_corresponding":false,"raw_author_name":"Hu Xiong","raw_affiliation_strings":["State Grid Hubei Electric Power Co"],"raw_orcid":null,"affiliations":[{"raw_affiliation_string":"State Grid Hubei Electric Power Co","institution_ids":[]}]},{"author_position":"middle","author":{"id":null,"display_name":"Jiayuan Li","orcid":null},"institutions":[],"countries":[],"is_corresponding":false,"raw_author_name":"Jiayuan Li","raw_affiliation_strings":["State Grid Hubei Electric Power Co"],"raw_orcid":null,"affiliations":[{"raw_affiliation_string":"State Grid Hubei Electric Power Co","institution_ids":[]}]},{"author_position":"middle","author":{"id":null,"display_name":"Xiaoguang Jiang","orcid":null},"institutions":[],"countries":[],"is_corresponding":false,"raw_author_name":"Xiaoguang Jiang","raw_affiliation_strings":["State Grid Hubei Electric Power Co"],"raw_orcid":null,"affiliations":[{"raw_affiliation_string":"State Grid Hubei Electric Power Co","institution_ids":[]}]},{"author_position":"middle","author":{"id":null,"display_name":"Zhixiong Liu","orcid":null},"institutions":[{"id":"https://openalex.org/I37461747","display_name":"Wuhan University","ror":"https://ror.org/033vjfk17","country_code":"CN","type":"education","lineage":["https://openalex.org/I37461747"]}],"countries":["CN"],"is_corresponding":false,"raw_author_name":"Zhixiong Liu","raw_affiliation_strings":["Wuhan University"],"raw_orcid":null,"affiliations":[{"raw_affiliation_string":"Wuhan University","institution_ids":["https://openalex.org/I37461747"]}]},{"author_position":"last","author":{"id":null,"display_name":"Jiarui Yang","orcid":null},"institutions":[{"id":"https://openalex.org/I37461747","display_name":"Wuhan University","ror":"https://ror.org/033vjfk17","country_code":"CN","type":"education","lineage":["https://openalex.org/I37461747"]}],"countries":["CN"],"is_corresponding":false,"raw_author_name":"Jiarui Yang","raw_affiliation_strings":["Wuhan University"],"raw_orcid":null,"affiliations":[{"raw_affiliation_string":"Wuhan University","institution_ids":["https://openalex.org/I37461747"]}]}],"institutions":[],"countries_distinct_count":1,"institutions_distinct_count":1,"corresponding_author_ids":[],"corresponding_institution_ids":[],"apc_list":null,"apc_paid":null,"fwci":0.0,"has_fulltext":false,"cited_by_count":0,"citation_normalized_percentile":{"value":0.51359536,"is_in_top_1_percent":false,"is_in_top_10_percent":false},"cited_by_percentile_year":null,"biblio":{"volume":"29","issue":"2","first_page":"38","last_page":"45"},"is_retracted":false,"is_paratext":false,"is_xpac":false,"primary_topic":{"id":"https://openalex.org/T12804","display_name":"Thermal Analysis in Power Transmission","score":0.7940000295639038,"subfield":{"id":"https://openalex.org/subfields/2207","display_name":"Control and Systems Engineering"},"field":{"id":"https://openalex.org/fields/22","display_name":"Engineering"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}},"topics":[{"id":"https://openalex.org/T12804","display_name":"Thermal Analysis in Power Transmission","score":0.7940000295639038,"subfield":{"id":"https://openalex.org/subfields/2207","display_name":"Control and Systems Engineering"},"field":{"id":"https://openalex.org/fields/22","display_name":"Engineering"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}},{"id":"https://openalex.org/T10511","display_name":"High voltage insulation and dielectric phenomena","score":0.11330000311136246,"subfield":{"id":"https://openalex.org/subfields/2505","display_name":"Materials Chemistry"},"field":{"id":"https://openalex.org/fields/25","display_name":"Materials Science"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}},{"id":"https://openalex.org/T12737","display_name":"Electrical Fault Detection and Protection","score":0.010300000198185444,"subfield":{"id":"https://openalex.org/subfields/2208","display_name":"Electrical and Electronic Engineering"},"field":{"id":"https://openalex.org/fields/22","display_name":"Engineering"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}}],"keywords":[{"id":"https://openalex.org/keywords/switchgear","display_name":"Switchgear","score":0.9517999887466431},{"id":"https://openalex.org/keywords/overheating","display_name":"Overheating (electricity)","score":0.906499981880188},{"id":"https://openalex.org/keywords/reliability","display_name":"Reliability (semiconductor)","score":0.5644999742507935},{"id":"https://openalex.org/keywords/power-grid","display_name":"Power grid","score":0.4876999855041504},{"id":"https://openalex.org/keywords/dissipation","display_name":"Dissipation","score":0.42669999599456787},{"id":"https://openalex.org/keywords/temperature-measurement","display_name":"Temperature measurement","score":0.36820000410079956},{"id":"https://openalex.org/keywords/electric-power-system","display_name":"Electric power system","score":0.3646000027656555},{"id":"https://openalex.org/keywords/fuse","display_name":"Fuse (electrical)","score":0.3506999909877777},{"id":"https://openalex.org/keywords/dielectric-withstand-test","display_name":"Dielectric withstand test","score":0.3450999855995178}],"concepts":[{"id":"https://openalex.org/C93893174","wikidata":"https://www.wikidata.org/wiki/Q1273786","display_name":"Switchgear","level":2,"score":0.9517999887466431},{"id":"https://openalex.org/C2778284599","wikidata":"https://www.wikidata.org/wiki/Q25340000","display_name":"Overheating (electricity)","level":2,"score":0.906499981880188},{"id":"https://openalex.org/C43214815","wikidata":"https://www.wikidata.org/wiki/Q7310987","display_name":"Reliability (semiconductor)","level":3,"score":0.5644999742507935},{"id":"https://openalex.org/C127413603","wikidata":"https://www.wikidata.org/wiki/Q11023","display_name":"Engineering","level":0,"score":0.5238000154495239},{"id":"https://openalex.org/C171146098","wikidata":"https://www.wikidata.org/wiki/Q124192","display_name":"Automotive engineering","level":1,"score":0.5038999915122986},{"id":"https://openalex.org/C2983254600","wikidata":"https://www.wikidata.org/wiki/Q1096907","display_name":"Power grid","level":3,"score":0.4876999855041504},{"id":"https://openalex.org/C119599485","wikidata":"https://www.wikidata.org/wiki/Q43035","display_name":"Electrical engineering","level":1,"score":0.4586000144481659},{"id":"https://openalex.org/C116915560","wikidata":"https://www.wikidata.org/wiki/Q83504","display_name":"Nuclear engineering","level":1,"score":0.45399999618530273},{"id":"https://openalex.org/C135402231","wikidata":"https://www.wikidata.org/wiki/Q898440","display_name":"Dissipation","level":2,"score":0.42669999599456787},{"id":"https://openalex.org/C200601418","wikidata":"https://www.wikidata.org/wiki/Q2193887","display_name":"Reliability engineering","level":1,"score":0.37040001153945923},{"id":"https://openalex.org/C72293138","wikidata":"https://www.wikidata.org/wiki/Q909741","display_name":"Temperature measurement","level":2,"score":0.36820000410079956},{"id":"https://openalex.org/C89227174","wikidata":"https://www.wikidata.org/wiki/Q2388981","display_name":"Electric power system","level":3,"score":0.3646000027656555},{"id":"https://openalex.org/C141353440","wikidata":"https://www.wikidata.org/wiki/Q182221","display_name":"Fuse (electrical)","level":2,"score":0.3506999909877777},{"id":"https://openalex.org/C190540093","wikidata":"https://www.wikidata.org/wiki/Q5274914","display_name":"Dielectric withstand test","level":3,"score":0.3450999855995178},{"id":"https://openalex.org/C130143024","wikidata":"https://www.wikidata.org/wiki/Q1929972","display_name":"Partial discharge","level":3,"score":0.3375999927520752},{"id":"https://openalex.org/C123671423","wikidata":"https://www.wikidata.org/wiki/Q332329","display_name":"Contact resistance","level":3,"score":0.33309999108314514},{"id":"https://openalex.org/C162175671","wikidata":"https://www.wikidata.org/wiki/Q3749263","display_name":"Electrical equipment","level":2,"score":0.3215999901294708},{"id":"https://openalex.org/C132519959","wikidata":"https://www.wikidata.org/wiki/Q3077373","display_name":"Test method","level":2,"score":0.3142000138759613},{"id":"https://openalex.org/C78519656","wikidata":"https://www.wikidata.org/wiki/Q101333","display_name":"Mechanical engineering","level":1,"score":0.30970001220703125},{"id":"https://openalex.org/C148043351","wikidata":"https://www.wikidata.org/wiki/Q4456944","display_name":"Current (fluid)","level":2,"score":0.3091000020503998},{"id":"https://openalex.org/C114834414","wikidata":"https://www.wikidata.org/wiki/Q15477170","display_name":"Thermal management of electronic devices and systems","level":2,"score":0.3075999915599823},{"id":"https://openalex.org/C163258240","wikidata":"https://www.wikidata.org/wiki/Q25342","display_name":"Power (physics)","level":2,"score":0.3019999861717224},{"id":"https://openalex.org/C64839514","wikidata":"https://www.wikidata.org/wiki/Q918306","display_name":"Thermal insulation","level":3,"score":0.2793000042438507},{"id":"https://openalex.org/C204530211","wikidata":"https://www.wikidata.org/wiki/Q752823","display_name":"Thermal","level":2,"score":0.2718999981880188},{"id":"https://openalex.org/C137693562","wikidata":"https://www.wikidata.org/wiki/Q899628","display_name":"Thermal resistance","level":3,"score":0.2619999945163727},{"id":"https://openalex.org/C202374169","wikidata":"https://www.wikidata.org/wiki/Q124291","display_name":"Electrical conductor","level":2,"score":0.2583000063896179},{"id":"https://openalex.org/C168993435","wikidata":"https://www.wikidata.org/wiki/Q6501125","display_name":"Ground","level":2,"score":0.2533000111579895},{"id":"https://openalex.org/C2780061162","wikidata":"https://www.wikidata.org/wiki/Q13221754","display_name":"Electric heating","level":2,"score":0.2522999942302704}],"mesh":[],"locations_count":1,"locations":[{"id":"doi:10.1109/mim.2025.11224806","is_oa":false,"landing_page_url":"https://doi.org/10.1109/mim.2025.11224806","pdf_url":null,"source":{"id":"https://openalex.org/S121167460","display_name":"IEEE Instrumentation & Measurement Magazine","issn_l":"1094-6969","issn":["1094-6969","1941-0123"],"is_oa":false,"is_in_doaj":false,"is_core":true,"host_organization":"https://openalex.org/P4310319808","host_organization_name":"Institute of Electrical and Electronics Engineers","host_organization_lineage":["https://openalex.org/P4310319808"],"host_organization_lineage_names":["Institute of Electrical and Electronics Engineers"],"type":"journal"},"license":null,"license_id":null,"version":"publishedVersion","is_accepted":true,"is_published":true,"raw_source_name":"IEEE Instrumentation &amp; Measurement Magazine","raw_type":"journal-article"}],"best_oa_location":null,"sustainable_development_goals":[{"id":"https://metadata.un.org/sdg/7","score":0.6547592878341675,"display_name":"Affordable and clean energy"}],"awards":[],"funders":[],"has_content":{"grobid_xml":false,"pdf":false},"content_urls":null,"referenced_works_count":0,"referenced_works":[],"related_works":[],"abstract_inverted_index":{"Low-voltage":[0],"switchgear":[1,14],"is":[2,15,41],"widely":[3],"used":[4],"in":[5,19,51],"power":[6,104],"distribution":[7,105],"networks.":[8],"The":[9],"temperature":[10,73,89,116],"rise":[11,90,117],"test":[12,30],"for":[13,119],"a":[16],"critical":[17],"step":[18],"verifying":[20],"the":[21,38,99,102],"safety":[22],"and":[23],"reliability":[24],"of":[25,101],"electrical":[26],"equipment":[27],"[1].":[28],"This":[29],"ensures":[31],"safe":[32],"operation:":[33],"when":[34],"current":[35],"flows":[36],"through":[37],"switchgear,":[39],"heat":[40,44],"generated.":[42],"Poor":[43],"dissipation":[45],"design":[46],"or":[47,69,79],"excessive":[48,88],"contact":[49,67],"resistance":[50],"components":[52],"may":[53,74,94],"lead":[54],"to":[55,64,83],"overheating":[56],"during":[57,109],"long-term":[58],"operation,":[59],"potentially":[60],"causing":[61],"accidents":[62],"due":[63],"insulation":[65,96],"aging,":[66],"burnout,":[68],"short-circuit":[70],"faults.":[71],"Excessive":[72],"also":[75],"trigger":[76],"partial":[77],"discharge":[78],"thermal":[80],"runaway,":[81],"leading":[82],"cascading":[84],"failures.":[85],"For":[86],"example,":[87],"at":[91],"cable":[92],"joints":[93],"cause":[95],"breakdown,":[97],"affecting":[98],"stability":[100],"entire":[103],"system":[106],"[2][3][4][5].":[107],"Currently,":[108],"material":[110],"procurement,":[111],"China":[112],"State":[113],"Grid":[114],"mandates":[115],"testing":[118],"low-voltage":[120],"switchgear.":[121]},"counts_by_year":[],"updated_date":"2026-04-02T13:48:15.688549","created_date":"2025-12-12T00:00:00"}
