{"id":"https://openalex.org/W4415821166","doi":"https://doi.org/10.1109/mim.2025.11224698","title":"Smart Meter-Based System for Real-Time Fault Diagnosis of Inter-Turn Short Circuits in Induction Motors Leveraging Attention-Enhanced ResNet","display_name":"Smart Meter-Based System for Real-Time Fault Diagnosis of Inter-Turn Short Circuits in Induction Motors Leveraging Attention-Enhanced ResNet","publication_year":2025,"publication_date":"2025-11-01","ids":{"openalex":"https://openalex.org/W4415821166","doi":"https://doi.org/10.1109/mim.2025.11224698"},"language":null,"primary_location":{"id":"doi:10.1109/mim.2025.11224698","is_oa":false,"landing_page_url":"https://doi.org/10.1109/mim.2025.11224698","pdf_url":null,"source":{"id":"https://openalex.org/S121167460","display_name":"IEEE Instrumentation & Measurement Magazine","issn_l":"1094-6969","issn":["1094-6969","1941-0123"],"is_oa":false,"is_in_doaj":false,"is_core":true,"host_organization":"https://openalex.org/P4310319808","host_organization_name":"Institute of Electrical and Electronics Engineers","host_organization_lineage":["https://openalex.org/P4310319808"],"host_organization_lineage_names":["Institute of Electrical and Electronics Engineers"],"type":"journal"},"license":null,"license_id":null,"version":"publishedVersion","is_accepted":true,"is_published":true,"raw_source_name":"IEEE Instrumentation &amp; Measurement Magazine","raw_type":"journal-article"},"type":"article","indexed_in":["crossref"],"open_access":{"is_oa":false,"oa_status":"closed","oa_url":null,"any_repository_has_fulltext":false},"authorships":[{"author_position":"first","author":{"id":"https://openalex.org/A5110770272","display_name":"Kun Xia","orcid":null},"institutions":[],"countries":[],"is_corresponding":false,"raw_author_name":"Kun Xia","raw_affiliation_strings":[],"raw_orcid":null,"affiliations":[]},{"author_position":"middle","author":{"id":"https://openalex.org/A5065125441","display_name":"Ziyu Zhou","orcid":"https://orcid.org/0000-0002-0792-1801"},"institutions":[],"countries":[],"is_corresponding":false,"raw_author_name":"Ziyu Zhou","raw_affiliation_strings":[],"raw_orcid":null,"affiliations":[]},{"author_position":"last","author":{"id":"https://openalex.org/A5101840275","display_name":"Jingxia Wang","orcid":"https://orcid.org/0000-0002-6715-3277"},"institutions":[],"countries":[],"is_corresponding":false,"raw_author_name":"Jingxia Wang","raw_affiliation_strings":[],"raw_orcid":null,"affiliations":[]}],"institutions":[],"countries_distinct_count":0,"institutions_distinct_count":0,"corresponding_author_ids":[],"corresponding_institution_ids":[],"apc_list":null,"apc_paid":null,"fwci":0.0,"has_fulltext":false,"cited_by_count":0,"citation_normalized_percentile":{"value":0.35181377,"is_in_top_1_percent":false,"is_in_top_10_percent":false},"cited_by_percentile_year":null,"biblio":{"volume":"28","issue":"8","first_page":"3","last_page":"10"},"is_retracted":false,"is_paratext":false,"is_xpac":false,"primary_topic":{"id":"https://openalex.org/T10220","display_name":"Machine Fault Diagnosis Techniques","score":0.9871000051498413,"subfield":{"id":"https://openalex.org/subfields/2207","display_name":"Control and Systems Engineering"},"field":{"id":"https://openalex.org/fields/22","display_name":"Engineering"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}},"topics":[{"id":"https://openalex.org/T10220","display_name":"Machine Fault Diagnosis Techniques","score":0.9871000051498413,"subfield":{"id":"https://openalex.org/subfields/2207","display_name":"Control and Systems Engineering"},"field":{"id":"https://openalex.org/fields/22","display_name":"Engineering"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}},{"id":"https://openalex.org/T10228","display_name":"Multilevel Inverters and Converters","score":0.0024999999441206455,"subfield":{"id":"https://openalex.org/subfields/2208","display_name":"Electrical and Electronic Engineering"},"field":{"id":"https://openalex.org/fields/22","display_name":"Engineering"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}},{"id":"https://openalex.org/T12737","display_name":"Electrical Fault Detection and Protection","score":0.0017000000225380063,"subfield":{"id":"https://openalex.org/subfields/2208","display_name":"Electrical and Electronic Engineering"},"field":{"id":"https://openalex.org/fields/22","display_name":"Engineering"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}}],"keywords":[{"id":"https://openalex.org/keywords/fault-detection-and-isolation","display_name":"Fault detection and isolation","score":0.670799970626831},{"id":"https://openalex.org/keywords/fault","display_name":"Fault (geology)","score":0.6119999885559082},{"id":"https://openalex.org/keywords/stator","display_name":"Stator","score":0.5376999974250793},{"id":"https://openalex.org/keywords/induction-motor","display_name":"Induction motor","score":0.49900001287460327},{"id":"https://openalex.org/keywords/reliability","display_name":"Reliability (semiconductor)","score":0.42989999055862427},{"id":"https://openalex.org/keywords/residual","display_name":"Residual","score":0.41749998927116394},{"id":"https://openalex.org/keywords/fault-indicator","display_name":"Fault indicator","score":0.4092000126838684},{"id":"https://openalex.org/keywords/artificial-neural-network","display_name":"Artificial neural network","score":0.39730000495910645},{"id":"https://openalex.org/keywords/electromagnetic-coil","display_name":"Electromagnetic coil","score":0.3865000009536743},{"id":"https://openalex.org/keywords/voltage","display_name":"Voltage","score":0.37779998779296875}],"concepts":[{"id":"https://openalex.org/C152745839","wikidata":"https://www.wikidata.org/wiki/Q5438153","display_name":"Fault detection and isolation","level":3,"score":0.670799970626831},{"id":"https://openalex.org/C175551986","wikidata":"https://www.wikidata.org/wiki/Q47089","display_name":"Fault (geology)","level":2,"score":0.6119999885559082},{"id":"https://openalex.org/C127413603","wikidata":"https://www.wikidata.org/wiki/Q11023","display_name":"Engineering","level":0,"score":0.5467000007629395},{"id":"https://openalex.org/C2776529397","wikidata":"https://www.wikidata.org/wiki/Q190312","display_name":"Stator","level":2,"score":0.5376999974250793},{"id":"https://openalex.org/C80962145","wikidata":"https://www.wikidata.org/wiki/Q207450","display_name":"Induction motor","level":3,"score":0.49900001287460327},{"id":"https://openalex.org/C41008148","wikidata":"https://www.wikidata.org/wiki/Q21198","display_name":"Computer science","level":0,"score":0.46149998903274536},{"id":"https://openalex.org/C43214815","wikidata":"https://www.wikidata.org/wiki/Q7310987","display_name":"Reliability (semiconductor)","level":3,"score":0.42989999055862427},{"id":"https://openalex.org/C155512373","wikidata":"https://www.wikidata.org/wiki/Q287450","display_name":"Residual","level":2,"score":0.41749998927116394},{"id":"https://openalex.org/C133731056","wikidata":"https://www.wikidata.org/wiki/Q4917288","display_name":"Control engineering","level":1,"score":0.4099000096321106},{"id":"https://openalex.org/C21267803","wikidata":"https://www.wikidata.org/wiki/Q5438159","display_name":"Fault indicator","level":4,"score":0.4092000126838684},{"id":"https://openalex.org/C50644808","wikidata":"https://www.wikidata.org/wiki/Q192776","display_name":"Artificial neural network","level":2,"score":0.39730000495910645},{"id":"https://openalex.org/C30403606","wikidata":"https://www.wikidata.org/wiki/Q2981904","display_name":"Electromagnetic coil","level":2,"score":0.3865000009536743},{"id":"https://openalex.org/C165801399","wikidata":"https://www.wikidata.org/wiki/Q25428","display_name":"Voltage","level":2,"score":0.37779998779296875},{"id":"https://openalex.org/C2775846686","wikidata":"https://www.wikidata.org/wiki/Q643012","display_name":"Condition monitoring","level":2,"score":0.34619998931884766},{"id":"https://openalex.org/C79403827","wikidata":"https://www.wikidata.org/wiki/Q3988","display_name":"Real-time computing","level":1,"score":0.32919999957084656},{"id":"https://openalex.org/C67172668","wikidata":"https://www.wikidata.org/wiki/Q622756","display_name":"Electricity meter","level":3,"score":0.32739999890327454},{"id":"https://openalex.org/C176871988","wikidata":"https://www.wikidata.org/wiki/Q72313","display_name":"Electric motor","level":2,"score":0.31310001015663147},{"id":"https://openalex.org/C24326235","wikidata":"https://www.wikidata.org/wiki/Q126095","display_name":"Electronic engineering","level":1,"score":0.3098999857902527},{"id":"https://openalex.org/C2412688","wikidata":"https://www.wikidata.org/wiki/Q503732","display_name":"Protective relay","level":4,"score":0.30309998989105225},{"id":"https://openalex.org/C13625343","wikidata":"https://www.wikidata.org/wiki/Q7627418","display_name":"Stuck-at fault","level":4,"score":0.3003999888896942},{"id":"https://openalex.org/C89227174","wikidata":"https://www.wikidata.org/wiki/Q2388981","display_name":"Electric power system","level":3,"score":0.29179999232292175},{"id":"https://openalex.org/C61352017","wikidata":"https://www.wikidata.org/wiki/Q211058","display_name":"Circuit breaker","level":2,"score":0.29159998893737793},{"id":"https://openalex.org/C126953365","wikidata":"https://www.wikidata.org/wiki/Q5438152","display_name":"Fault coverage","level":3,"score":0.2849999964237213},{"id":"https://openalex.org/C134146338","wikidata":"https://www.wikidata.org/wiki/Q1815901","display_name":"Electronic circuit","level":2,"score":0.28439998626708984},{"id":"https://openalex.org/C38361682","wikidata":"https://www.wikidata.org/wiki/Q1756067","display_name":"Power-system protection","level":4,"score":0.2825999855995178},{"id":"https://openalex.org/C149635348","wikidata":"https://www.wikidata.org/wiki/Q193040","display_name":"Embedded system","level":1,"score":0.27799999713897705},{"id":"https://openalex.org/C176563091","wikidata":"https://www.wikidata.org/wiki/Q669238","display_name":"Intelligent sensor","level":3,"score":0.2736999988555908},{"id":"https://openalex.org/C2779510800","wikidata":"https://www.wikidata.org/wiki/Q1630602","display_name":"Smart meter","level":3,"score":0.2702000141143799},{"id":"https://openalex.org/C200601418","wikidata":"https://www.wikidata.org/wiki/Q2193887","display_name":"Reliability engineering","level":1,"score":0.26980000734329224},{"id":"https://openalex.org/C52622490","wikidata":"https://www.wikidata.org/wiki/Q1026626","display_name":"Feature extraction","level":2,"score":0.26899999380111694},{"id":"https://openalex.org/C32022120","wikidata":"https://www.wikidata.org/wiki/Q797225","display_name":"Interference (communication)","level":3,"score":0.26589998602867126},{"id":"https://openalex.org/C196796808","wikidata":"https://www.wikidata.org/wiki/Q132629","display_name":"Electrical network","level":2,"score":0.265500009059906},{"id":"https://openalex.org/C126780896","wikidata":"https://www.wikidata.org/wiki/Q899871","display_name":"Distortion (music)","level":4,"score":0.2597000002861023},{"id":"https://openalex.org/C68583231","wikidata":"https://www.wikidata.org/wiki/Q206907","display_name":"Short circuit","level":3,"score":0.2563000023365021},{"id":"https://openalex.org/C151011524","wikidata":"https://www.wikidata.org/wiki/Q11573","display_name":"Metre","level":2,"score":0.25429999828338623}],"mesh":[],"locations_count":1,"locations":[{"id":"doi:10.1109/mim.2025.11224698","is_oa":false,"landing_page_url":"https://doi.org/10.1109/mim.2025.11224698","pdf_url":null,"source":{"id":"https://openalex.org/S121167460","display_name":"IEEE Instrumentation & Measurement Magazine","issn_l":"1094-6969","issn":["1094-6969","1941-0123"],"is_oa":false,"is_in_doaj":false,"is_core":true,"host_organization":"https://openalex.org/P4310319808","host_organization_name":"Institute of Electrical and Electronics Engineers","host_organization_lineage":["https://openalex.org/P4310319808"],"host_organization_lineage_names":["Institute of Electrical and Electronics Engineers"],"type":"journal"},"license":null,"license_id":null,"version":"publishedVersion","is_accepted":true,"is_published":true,"raw_source_name":"IEEE Instrumentation &amp; Measurement Magazine","raw_type":"journal-article"}],"best_oa_location":null,"sustainable_development_goals":[],"awards":[],"funders":[],"has_content":{"grobid_xml":false,"pdf":false},"content_urls":null,"referenced_works_count":15,"referenced_works":["https://openalex.org/W2943389092","https://openalex.org/W2972184175","https://openalex.org/W2991221038","https://openalex.org/W3046966979","https://openalex.org/W3094517863","https://openalex.org/W3139011613","https://openalex.org/W3167120002","https://openalex.org/W4285291864","https://openalex.org/W4313041929","https://openalex.org/W4313119025","https://openalex.org/W4313428502","https://openalex.org/W4320713298","https://openalex.org/W4362650689","https://openalex.org/W4375854195","https://openalex.org/W4396553997"],"related_works":[],"abstract_inverted_index":{"Early-stage":[0],"inter-turn":[1],"short":[2],"circuits":[3],"(ITSC)":[4],"in":[5,27],"three-phase":[6],"induction":[7],"motor":[8,78],"(TIM)":[9],"stators":[10],"present":[11],"critical":[12],"detection":[13,61,131,141],"reliability":[14],"challenges":[15],"due":[16],"to":[17,35,48,70],"their":[18],"subtle":[19],"electrical":[20,94],"signatures.":[21],"These":[22],"faults":[23,47],"induce":[24],"current":[25],"deviations":[26],"stator":[28],"windings":[29],"-":[30],"variations":[31],"that":[32],"are":[33],"difficult":[34],"distinguish":[36],"from":[37,85,93],"inherent":[38],"voltage":[39,86,119],"unbalance":[40,87],"effects.":[41],"This":[42,54,133],"diagnostic":[43],"ambiguity":[44],"allows":[45],"incipient":[46],"evolve":[49],"into":[50],"catastrophic":[51],"winding":[52],"failures.":[53],"study":[55],"proposes":[56],"a":[57,64,102],"novel":[58],"real-time":[59],"fault":[60,90,130,140],"system":[62,74],"integrating":[63],"smart":[65,98,144],"meter":[66,145],"and":[67,100,120,143],"neural":[68],"networks":[69],"address":[71],"limitations.":[72],"The":[73],"enables":[75],"high-precision,":[76],"non-intrusive":[77],"condition":[79],"monitoring":[80],"while":[81],"effectively":[82],"mitigating":[83],"interference":[84],"by":[88,97],"automating":[89],"feature":[91],"extraction":[92],"signals":[95],"collected":[96],"meters":[99],"utilizing":[101],"Residual":[103],"Neural":[104],"Network":[105],"(ResNet)":[106],"incorporating":[107],"the":[108,136],"Squeeze-and-Excitation":[109],"attention":[110],"mechanism":[111],"(SENet)":[112],"for":[113],"processing":[114],"multi-channel":[115],"input":[116],"data":[117],"(three-phase":[118],"current),":[121],"enhancing":[122],"fault-related":[123],"features.":[124],"Cloud-based":[125],"deployment":[126],"further":[127],"enhances":[128],"online":[129],"performance.":[132],"approach":[134],"highlights":[135],"synergy":[137],"between":[138],"advanced":[139],"techniques":[142],"capabilities.":[146]},"counts_by_year":[],"updated_date":"2025-11-06T03:46:38.306776","created_date":"2025-11-03T00:00:00"}
