{"id":"https://openalex.org/W3171193412","doi":"https://doi.org/10.1109/mim.2021.9448264","title":"Electro-Microfluidic Viscometer with Integrated Microcontroller and Pumping System for Point-of-Care Biosensing Applications","display_name":"Electro-Microfluidic Viscometer with Integrated Microcontroller and Pumping System for Point-of-Care Biosensing Applications","publication_year":2021,"publication_date":"2021-06-01","ids":{"openalex":"https://openalex.org/W3171193412","doi":"https://doi.org/10.1109/mim.2021.9448264","mag":"3171193412"},"language":"en","primary_location":{"id":"doi:10.1109/mim.2021.9448264","is_oa":false,"landing_page_url":"https://doi.org/10.1109/mim.2021.9448264","pdf_url":null,"source":{"id":"https://openalex.org/S121167460","display_name":"IEEE Instrumentation & Measurement Magazine","issn_l":"1094-6969","issn":["1094-6969","1941-0123"],"is_oa":false,"is_in_doaj":false,"is_core":true,"host_organization":"https://openalex.org/P4310319808","host_organization_name":"Institute of Electrical and Electronics Engineers","host_organization_lineage":["https://openalex.org/P4310319808"],"host_organization_lineage_names":["Institute of Electrical and Electronics Engineers"],"type":"journal"},"license":null,"license_id":null,"version":"publishedVersion","is_accepted":true,"is_published":true,"raw_source_name":"IEEE Instrumentation &amp; Measurement Magazine","raw_type":"journal-article"},"type":"article","indexed_in":["crossref"],"open_access":{"is_oa":false,"oa_status":"closed","oa_url":null,"any_repository_has_fulltext":false},"authorships":[{"author_position":"first","author":{"id":"https://openalex.org/A5022106362","display_name":"S B Puneeth","orcid":null},"institutions":[{"id":"https://openalex.org/I4210101034","display_name":"Birla Institute of Technology and Science - Hyderabad Campus","ror":"https://ror.org/014ctt859","country_code":"IN","type":"education","lineage":["https://openalex.org/I4210101034","https://openalex.org/I74796645"]}],"countries":["IN"],"is_corresponding":false,"raw_author_name":"S. B. Puneeth","raw_affiliation_strings":["Birla Institute of Technology and Science, Hyderabad, India"],"raw_orcid":null,"affiliations":[{"raw_affiliation_string":"Birla Institute of Technology and Science, Hyderabad, India","institution_ids":["https://openalex.org/I4210101034"]}]},{"author_position":"middle","author":{"id":"https://openalex.org/A5047175435","display_name":"H. L. Hithesh","orcid":null},"institutions":[{"id":"https://openalex.org/I4210101034","display_name":"Birla Institute of Technology and Science - Hyderabad Campus","ror":"https://ror.org/014ctt859","country_code":"IN","type":"education","lineage":["https://openalex.org/I4210101034","https://openalex.org/I74796645"]}],"countries":["IN"],"is_corresponding":false,"raw_author_name":"H. L. Hithesh","raw_affiliation_strings":["Birla Institute of Technology and Science, Hyderabad, India"],"raw_orcid":null,"affiliations":[{"raw_affiliation_string":"Birla Institute of Technology and Science, Hyderabad, India","institution_ids":["https://openalex.org/I4210101034"]}]},{"author_position":"last","author":{"id":"https://openalex.org/A5047102862","display_name":"Sanket Goel","orcid":"https://orcid.org/0000-0002-9739-4178"},"institutions":[{"id":"https://openalex.org/I4210101034","display_name":"Birla Institute of Technology and Science - Hyderabad Campus","ror":"https://ror.org/014ctt859","country_code":"IN","type":"education","lineage":["https://openalex.org/I4210101034","https://openalex.org/I74796645"]}],"countries":["IN"],"is_corresponding":false,"raw_author_name":"Sanket Goel","raw_affiliation_strings":["MEMS, Microfluidics and Nanoelectronics Lab, BITS-Pilani, Hyderabad, India"],"raw_orcid":null,"affiliations":[{"raw_affiliation_string":"MEMS, Microfluidics and Nanoelectronics Lab, BITS-Pilani, Hyderabad, India","institution_ids":["https://openalex.org/I4210101034"]}]}],"institutions":[],"countries_distinct_count":1,"institutions_distinct_count":1,"corresponding_author_ids":[],"corresponding_institution_ids":["https://openalex.org/I4210101034"],"apc_list":null,"apc_paid":null,"fwci":0.1698,"has_fulltext":false,"cited_by_count":4,"citation_normalized_percentile":{"value":0.44573539,"is_in_top_1_percent":false,"is_in_top_10_percent":false},"cited_by_percentile_year":{"min":91,"max":97},"biblio":{"volume":"24","issue":"4","first_page":"23","last_page":"28"},"is_retracted":false,"is_paratext":false,"is_xpac":false,"primary_topic":{"id":"https://openalex.org/T10412","display_name":"Microfluidic and Capillary Electrophoresis Applications","score":0.9998999834060669,"subfield":{"id":"https://openalex.org/subfields/2204","display_name":"Biomedical Engineering"},"field":{"id":"https://openalex.org/fields/22","display_name":"Engineering"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}},"topics":[{"id":"https://openalex.org/T10412","display_name":"Microfluidic and Capillary Electrophoresis Applications","score":0.9998999834060669,"subfield":{"id":"https://openalex.org/subfields/2204","display_name":"Biomedical Engineering"},"field":{"id":"https://openalex.org/fields/22","display_name":"Engineering"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}},{"id":"https://openalex.org/T11255","display_name":"Microfluidic and Bio-sensing Technologies","score":0.9998999834060669,"subfield":{"id":"https://openalex.org/subfields/2204","display_name":"Biomedical Engineering"},"field":{"id":"https://openalex.org/fields/22","display_name":"Engineering"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}},{"id":"https://openalex.org/T11393","display_name":"Biosensors and Analytical Detection","score":0.9983999729156494,"subfield":{"id":"https://openalex.org/subfields/2204","display_name":"Biomedical Engineering"},"field":{"id":"https://openalex.org/fields/22","display_name":"Engineering"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}}],"keywords":[{"id":"https://openalex.org/keywords/viscometer","display_name":"Viscometer","score":0.9289847612380981},{"id":"https://openalex.org/keywords/microfluidics","display_name":"Microfluidics","score":0.6753209829330444},{"id":"https://openalex.org/keywords/microchannel","display_name":"Microchannel","score":0.6488336324691772},{"id":"https://openalex.org/keywords/materials-science","display_name":"Materials science","score":0.5729845762252808},{"id":"https://openalex.org/keywords/microcontroller","display_name":"Microcontroller","score":0.5174161195755005},{"id":"https://openalex.org/keywords/biosensor","display_name":"Biosensor","score":0.511695384979248},{"id":"https://openalex.org/keywords/viscosity","display_name":"Viscosity","score":0.45700252056121826},{"id":"https://openalex.org/keywords/peristaltic-pump","display_name":"Peristaltic pump","score":0.43445777893066406},{"id":"https://openalex.org/keywords/biomedical-engineering","display_name":"Biomedical engineering","score":0.35182178020477295},{"id":"https://openalex.org/keywords/nanotechnology","display_name":"Nanotechnology","score":0.31589609384536743},{"id":"https://openalex.org/keywords/computer-science","display_name":"Computer science","score":0.3021770715713501},{"id":"https://openalex.org/keywords/embedded-system","display_name":"Embedded system","score":0.1832643747329712},{"id":"https://openalex.org/keywords/engineering","display_name":"Engineering","score":0.15732336044311523},{"id":"https://openalex.org/keywords/mechanical-engineering","display_name":"Mechanical engineering","score":0.15088891983032227},{"id":"https://openalex.org/keywords/composite-material","display_name":"Composite material","score":0.10132157802581787}],"concepts":[{"id":"https://openalex.org/C93356670","wikidata":"https://www.wikidata.org/wiki/Q868743","display_name":"Viscometer","level":3,"score":0.9289847612380981},{"id":"https://openalex.org/C8673954","wikidata":"https://www.wikidata.org/wiki/Q138845","display_name":"Microfluidics","level":2,"score":0.6753209829330444},{"id":"https://openalex.org/C63662833","wikidata":"https://www.wikidata.org/wiki/Q6839341","display_name":"Microchannel","level":2,"score":0.6488336324691772},{"id":"https://openalex.org/C192562407","wikidata":"https://www.wikidata.org/wiki/Q228736","display_name":"Materials science","level":0,"score":0.5729845762252808},{"id":"https://openalex.org/C173018170","wikidata":"https://www.wikidata.org/wiki/Q165678","display_name":"Microcontroller","level":2,"score":0.5174161195755005},{"id":"https://openalex.org/C160756335","wikidata":"https://www.wikidata.org/wiki/Q669391","display_name":"Biosensor","level":2,"score":0.511695384979248},{"id":"https://openalex.org/C127172972","wikidata":"https://www.wikidata.org/wiki/Q128709","display_name":"Viscosity","level":2,"score":0.45700252056121826},{"id":"https://openalex.org/C134519083","wikidata":"https://www.wikidata.org/wiki/Q650921","display_name":"Peristaltic pump","level":2,"score":0.43445777893066406},{"id":"https://openalex.org/C136229726","wikidata":"https://www.wikidata.org/wiki/Q327092","display_name":"Biomedical engineering","level":1,"score":0.35182178020477295},{"id":"https://openalex.org/C171250308","wikidata":"https://www.wikidata.org/wiki/Q11468","display_name":"Nanotechnology","level":1,"score":0.31589609384536743},{"id":"https://openalex.org/C41008148","wikidata":"https://www.wikidata.org/wiki/Q21198","display_name":"Computer science","level":0,"score":0.3021770715713501},{"id":"https://openalex.org/C149635348","wikidata":"https://www.wikidata.org/wiki/Q193040","display_name":"Embedded system","level":1,"score":0.1832643747329712},{"id":"https://openalex.org/C127413603","wikidata":"https://www.wikidata.org/wiki/Q11023","display_name":"Engineering","level":0,"score":0.15732336044311523},{"id":"https://openalex.org/C78519656","wikidata":"https://www.wikidata.org/wiki/Q101333","display_name":"Mechanical engineering","level":1,"score":0.15088891983032227},{"id":"https://openalex.org/C159985019","wikidata":"https://www.wikidata.org/wiki/Q181790","display_name":"Composite material","level":1,"score":0.10132157802581787}],"mesh":[],"locations_count":1,"locations":[{"id":"doi:10.1109/mim.2021.9448264","is_oa":false,"landing_page_url":"https://doi.org/10.1109/mim.2021.9448264","pdf_url":null,"source":{"id":"https://openalex.org/S121167460","display_name":"IEEE Instrumentation & Measurement Magazine","issn_l":"1094-6969","issn":["1094-6969","1941-0123"],"is_oa":false,"is_in_doaj":false,"is_core":true,"host_organization":"https://openalex.org/P4310319808","host_organization_name":"Institute of Electrical and Electronics Engineers","host_organization_lineage":["https://openalex.org/P4310319808"],"host_organization_lineage_names":["Institute of Electrical and Electronics Engineers"],"type":"journal"},"license":null,"license_id":null,"version":"publishedVersion","is_accepted":true,"is_published":true,"raw_source_name":"IEEE Instrumentation &amp; Measurement Magazine","raw_type":"journal-article"}],"best_oa_location":null,"sustainable_development_goals":[],"awards":[],"funders":[],"has_content":{"pdf":false,"grobid_xml":false},"content_urls":null,"referenced_works_count":13,"referenced_works":["https://openalex.org/W1770420141","https://openalex.org/W1964186648","https://openalex.org/W2112971416","https://openalex.org/W2140347085","https://openalex.org/W2294364997","https://openalex.org/W2335110132","https://openalex.org/W2342973494","https://openalex.org/W2617692000","https://openalex.org/W2625295457","https://openalex.org/W2891920990","https://openalex.org/W2941200683","https://openalex.org/W2952772784","https://openalex.org/W2960258433"],"related_works":["https://openalex.org/W2244863842","https://openalex.org/W1818839458","https://openalex.org/W2387714547","https://openalex.org/W4379229462","https://openalex.org/W4377019070","https://openalex.org/W3095560982","https://openalex.org/W3085731770","https://openalex.org/W2800781465","https://openalex.org/W4200169273","https://openalex.org/W1964765353"],"abstract_inverted_index":{"Viscometers":[0],"are":[1,154],"extensively":[2],"utilized":[3],"for":[4],"a":[5,38,54,72,95,99,156,162],"wide":[6],"variety":[7],"of":[8,53,94,112,141,169],"sensing":[9],"and":[10,21,46,57,68,79,84,92,102,121,133],"monitoring":[11],"applications":[12],"like":[13],"biomedical":[14],"diagnostics,":[15],"biochemical":[16],"optimization,":[17],"fluid":[18,131],"adulteration":[19],"detection":[20],"quality":[22],"control":[23],"in":[24,29,71],"pharmaceuticals.":[25],"Realizing":[26],"the":[27,30,51,103,109,129,166,170],"viscometer":[28],"lab-on-chip/microfluidic":[31],"domain":[32],"increases":[33],"its":[34],"potential":[35,168],"to":[36,105,128,149],"be":[37],"point-of-care":[39],"device":[40,138,172],"by":[41],"making":[42],"it":[43],"completely":[44,76],"automated":[45],"robust.":[47],"This":[48],"work":[49],"presents":[50],"development":[52],"simplified,":[55],"cost-effective":[56],"time":[58],"efficient":[59],"3D":[60],"Printed":[61],"(3DP)":[62],"Electro-Microfluidic":[63],"Viscometer":[64],"(EMV),":[65],"with":[66,98,126,161,173],"microchannel":[67],"intersecting":[69],"electrodes,":[70],"single-step":[73],"process.":[74],"A":[75],"automated,":[77],"integrated":[78],"handheld":[80],"EMV":[81],"was":[82],"realized":[83],"comprised":[85],"an":[86],"in-house":[87],"made":[88],"3DP":[89],"peristaltic":[90],"pump":[91],"motherboard":[93],"microcontroller,":[96],"along":[97],"display":[100],"unit":[101],"microcontroller":[104],"estimate":[106],"viscosity.":[107],"Here,":[108],"viscosity":[110,143],"values":[111,144,153],"bovine":[113],"serum":[114,118],"albumin":[115,119],"(BSA),":[116],"human":[117],"(HSA),":[120],"lysozyme":[122],"enzyme":[123],"were":[124],"measured":[125],"respect":[127],"reference":[130],"before":[132],"after":[134],"denaturation.":[135],"The":[136],"developed":[137],"is":[139],"capable":[140],"measuring":[142],"ranging":[145],"from":[146],"0.5":[147],"cP":[148],"10":[150],"cP.":[151],"These":[152],"within":[155],"\u00b16%":[157],"limit":[158],"when":[159],"compared":[160],"benchtop":[163],"viscometer,":[164],"showing":[165],"commercial":[167],"present":[171],"innumerable":[174],"add-on":[175],"features.":[176]},"counts_by_year":[{"year":2026,"cited_by_count":1},{"year":2025,"cited_by_count":1},{"year":2022,"cited_by_count":2}],"updated_date":"2026-06-26T08:34:08.712188","created_date":"2025-10-10T00:00:00"}
