{"id":"https://openalex.org/W1983271167","doi":"https://doi.org/10.1109/milcom.2011.6127765","title":"Coalition formation games for energy-efficient wireless network cocast","display_name":"Coalition formation games for energy-efficient wireless network cocast","publication_year":2011,"publication_date":"2011-11-01","ids":{"openalex":"https://openalex.org/W1983271167","doi":"https://doi.org/10.1109/milcom.2011.6127765","mag":"1983271167"},"language":"en","primary_location":{"id":"doi:10.1109/milcom.2011.6127765","is_oa":false,"landing_page_url":"https://doi.org/10.1109/milcom.2011.6127765","pdf_url":null,"source":null,"license":null,"license_id":null,"version":"publishedVersion","is_accepted":true,"is_published":true,"raw_source_name":"2011 - MILCOM 2011 Military Communications Conference","raw_type":"proceedings-article"},"type":"article","indexed_in":["crossref"],"open_access":{"is_oa":false,"oa_status":"closed","oa_url":null,"any_repository_has_fulltext":false},"authorships":[{"author_position":"first","author":{"id":"https://openalex.org/A5080061286","display_name":"Hung-Quoc Lai","orcid":null},"institutions":[{"id":"https://openalex.org/I66946132","display_name":"University of Maryland, College Park","ror":"https://ror.org/047s2c258","country_code":"US","type":"education","lineage":["https://openalex.org/I66946132"]},{"id":"https://openalex.org/I1304082316","display_name":"United States Department of the Army","ror":"https://ror.org/035w1gb98","country_code":"US","type":"government","lineage":["https://openalex.org/I1304082316","https://openalex.org/I1330347796"]}],"countries":["US"],"is_corresponding":true,"raw_author_name":"Hung-Quoc Lai","raw_affiliation_strings":["Department of Electrical and Computer Engineering, University of Maryland, College Park, MD, USA","US Army RDECOM CERDEC, RDER-STA-DS, Aberdeen Proving Ground, MD 21005, USA"],"affiliations":[{"raw_affiliation_string":"Department of Electrical and Computer Engineering, University of Maryland, College Park, MD, USA","institution_ids":["https://openalex.org/I66946132"]},{"raw_affiliation_string":"US Army RDECOM CERDEC, RDER-STA-DS, Aberdeen Proving Ground, MD 21005, USA","institution_ids":["https://openalex.org/I1304082316"]}]},{"author_position":"middle","author":{"id":"https://openalex.org/A5100703983","display_name":"Yan Chen","orcid":"https://orcid.org/0009-0005-0674-2675"},"institutions":[{"id":"https://openalex.org/I66946132","display_name":"University of Maryland, College Park","ror":"https://ror.org/047s2c258","country_code":"US","type":"education","lineage":["https://openalex.org/I66946132"]}],"countries":["US"],"is_corresponding":false,"raw_author_name":"Yan Chen","raw_affiliation_strings":["Department of Electrical and Computer Engineering, University of Maryland, College Park, MD, USA","Department of Electrical and Computer Engineering, University of Maryland, College Park 20742, USA"],"affiliations":[{"raw_affiliation_string":"Department of Electrical and Computer Engineering, University of Maryland, College Park, MD, USA","institution_ids":["https://openalex.org/I66946132"]},{"raw_affiliation_string":"Department of Electrical and Computer Engineering, University of Maryland, College Park 20742, USA","institution_ids":["https://openalex.org/I66946132"]}]},{"author_position":"last","author":{"id":"https://openalex.org/A5032395820","display_name":"K. J. Ray Liu","orcid":"https://orcid.org/0000-0001-5469-5811"},"institutions":[{"id":"https://openalex.org/I66946132","display_name":"University of Maryland, College Park","ror":"https://ror.org/047s2c258","country_code":"US","type":"education","lineage":["https://openalex.org/I66946132"]}],"countries":["US"],"is_corresponding":false,"raw_author_name":"K. J. Ray Liu","raw_affiliation_strings":["Department of Electrical and Computer Engineering, University of Maryland, College Park, MD, USA","Department of Electrical and Computer Engineering, University of Maryland, College Park 20742, USA"],"affiliations":[{"raw_affiliation_string":"Department of Electrical and Computer Engineering, University of Maryland, College Park, MD, USA","institution_ids":["https://openalex.org/I66946132"]},{"raw_affiliation_string":"Department of Electrical and Computer Engineering, University of Maryland, College Park 20742, USA","institution_ids":["https://openalex.org/I66946132"]}]}],"institutions":[],"countries_distinct_count":1,"institutions_distinct_count":3,"corresponding_author_ids":["https://openalex.org/A5080061286"],"corresponding_institution_ids":["https://openalex.org/I1304082316","https://openalex.org/I66946132"],"apc_list":null,"apc_paid":null,"fwci":0.0,"has_fulltext":false,"cited_by_count":0,"citation_normalized_percentile":{"value":0.10609006,"is_in_top_1_percent":false,"is_in_top_10_percent":false},"cited_by_percentile_year":null,"biblio":{"volume":null,"issue":null,"first_page":"741","last_page":"746"},"is_retracted":false,"is_paratext":false,"is_xpac":false,"primary_topic":{"id":"https://openalex.org/T10796","display_name":"Cooperative Communication and Network Coding","score":1.0,"subfield":{"id":"https://openalex.org/subfields/1705","display_name":"Computer Networks and Communications"},"field":{"id":"https://openalex.org/fields/17","display_name":"Computer Science"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}},"topics":[{"id":"https://openalex.org/T10796","display_name":"Cooperative Communication and Network Coding","score":1.0,"subfield":{"id":"https://openalex.org/subfields/1705","display_name":"Computer Networks and Communications"},"field":{"id":"https://openalex.org/fields/17","display_name":"Computer Science"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}},{"id":"https://openalex.org/T10246","display_name":"Mobile Ad Hoc Networks","score":0.9984999895095825,"subfield":{"id":"https://openalex.org/subfields/1705","display_name":"Computer Networks and Communications"},"field":{"id":"https://openalex.org/fields/17","display_name":"Computer Science"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}},{"id":"https://openalex.org/T10148","display_name":"Advanced MIMO Systems Optimization","score":0.9973999857902527,"subfield":{"id":"https://openalex.org/subfields/2208","display_name":"Electrical and Electronic Engineering"},"field":{"id":"https://openalex.org/fields/22","display_name":"Engineering"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}}],"keywords":[{"id":"https://openalex.org/keywords/computer-network","display_name":"Computer network","score":0.7422469854354858},{"id":"https://openalex.org/keywords/computer-science","display_name":"Computer science","score":0.7359766364097595},{"id":"https://openalex.org/keywords/merge","display_name":"Merge (version control)","score":0.6532319188117981},{"id":"https://openalex.org/keywords/time-division-multiple-access","display_name":"Time division multiple access","score":0.5731738209724426},{"id":"https://openalex.org/keywords/efficient-energy-use","display_name":"Efficient energy use","score":0.5563790798187256},{"id":"https://openalex.org/keywords/quality-of-service","display_name":"Quality of service","score":0.5315969586372375},{"id":"https://openalex.org/keywords/wireless","display_name":"Wireless","score":0.4984734058380127},{"id":"https://openalex.org/keywords/wireless-network","display_name":"Wireless network","score":0.49096444249153137},{"id":"https://openalex.org/keywords/synchronization","display_name":"Synchronization (alternating current)","score":0.4663262665271759},{"id":"https://openalex.org/keywords/wireless-sensor-network","display_name":"Wireless sensor network","score":0.41088899970054626},{"id":"https://openalex.org/keywords/distributed-computing","display_name":"Distributed computing","score":0.39397257566452026},{"id":"https://openalex.org/keywords/telecommunications","display_name":"Telecommunications","score":0.24579063057899475},{"id":"https://openalex.org/keywords/engineering","display_name":"Engineering","score":0.14925578236579895}],"concepts":[{"id":"https://openalex.org/C31258907","wikidata":"https://www.wikidata.org/wiki/Q1301371","display_name":"Computer network","level":1,"score":0.7422469854354858},{"id":"https://openalex.org/C41008148","wikidata":"https://www.wikidata.org/wiki/Q21198","display_name":"Computer science","level":0,"score":0.7359766364097595},{"id":"https://openalex.org/C197129107","wikidata":"https://www.wikidata.org/wiki/Q1921621","display_name":"Merge (version control)","level":2,"score":0.6532319188117981},{"id":"https://openalex.org/C117313154","wikidata":"https://www.wikidata.org/wiki/Q878344","display_name":"Time division multiple access","level":2,"score":0.5731738209724426},{"id":"https://openalex.org/C2742236","wikidata":"https://www.wikidata.org/wiki/Q924713","display_name":"Efficient energy use","level":2,"score":0.5563790798187256},{"id":"https://openalex.org/C5119721","wikidata":"https://www.wikidata.org/wiki/Q220501","display_name":"Quality of service","level":2,"score":0.5315969586372375},{"id":"https://openalex.org/C555944384","wikidata":"https://www.wikidata.org/wiki/Q249","display_name":"Wireless","level":2,"score":0.4984734058380127},{"id":"https://openalex.org/C108037233","wikidata":"https://www.wikidata.org/wiki/Q11375","display_name":"Wireless network","level":3,"score":0.49096444249153137},{"id":"https://openalex.org/C2778562939","wikidata":"https://www.wikidata.org/wiki/Q1298791","display_name":"Synchronization (alternating current)","level":3,"score":0.4663262665271759},{"id":"https://openalex.org/C24590314","wikidata":"https://www.wikidata.org/wiki/Q336038","display_name":"Wireless sensor network","level":2,"score":0.41088899970054626},{"id":"https://openalex.org/C120314980","wikidata":"https://www.wikidata.org/wiki/Q180634","display_name":"Distributed computing","level":1,"score":0.39397257566452026},{"id":"https://openalex.org/C76155785","wikidata":"https://www.wikidata.org/wiki/Q418","display_name":"Telecommunications","level":1,"score":0.24579063057899475},{"id":"https://openalex.org/C127413603","wikidata":"https://www.wikidata.org/wiki/Q11023","display_name":"Engineering","level":0,"score":0.14925578236579895},{"id":"https://openalex.org/C127162648","wikidata":"https://www.wikidata.org/wiki/Q16858953","display_name":"Channel (broadcasting)","level":2,"score":0.0},{"id":"https://openalex.org/C23123220","wikidata":"https://www.wikidata.org/wiki/Q816826","display_name":"Information retrieval","level":1,"score":0.0},{"id":"https://openalex.org/C119599485","wikidata":"https://www.wikidata.org/wiki/Q43035","display_name":"Electrical engineering","level":1,"score":0.0}],"mesh":[],"locations_count":2,"locations":[{"id":"doi:10.1109/milcom.2011.6127765","is_oa":false,"landing_page_url":"https://doi.org/10.1109/milcom.2011.6127765","pdf_url":null,"source":null,"license":null,"license_id":null,"version":"publishedVersion","is_accepted":true,"is_published":true,"raw_source_name":"2011 - MILCOM 2011 Military Communications Conference","raw_type":"proceedings-article"},{"id":"pmh:oai:CiteSeerX.psu:10.1.1.419.3591","is_oa":false,"landing_page_url":"http://citeseerx.ist.psu.edu/viewdoc/summary?doi=10.1.1.419.3591","pdf_url":null,"source":null,"license":null,"license_id":null,"version":"submittedVersion","is_accepted":false,"is_published":false,"raw_source_name":"http://sig.umd.edu/publications/Lai_Milcom2011.pdf","raw_type":"text"}],"best_oa_location":null,"sustainable_development_goals":[{"display_name":"Affordable and clean energy","score":0.8999999761581421,"id":"https://metadata.un.org/sdg/7"}],"awards":[],"funders":[],"has_content":{"grobid_xml":false,"pdf":false},"content_urls":null,"referenced_works_count":11,"referenced_works":["https://openalex.org/W2090939903","https://openalex.org/W2098695001","https://openalex.org/W2115728676","https://openalex.org/W2136578267","https://openalex.org/W2139671306","https://openalex.org/W2140666908","https://openalex.org/W2152481521","https://openalex.org/W2161850939","https://openalex.org/W2313247059","https://openalex.org/W2798333393","https://openalex.org/W3128611524"],"related_works":["https://openalex.org/W2160222453","https://openalex.org/W2121800375","https://openalex.org/W2362971132","https://openalex.org/W2020063395","https://openalex.org/W2371687215","https://openalex.org/W1521875845","https://openalex.org/W1967958706","https://openalex.org/W2117591691","https://openalex.org/W2134795081","https://openalex.org/W4307865488"],"abstract_inverted_index":{"Wireless":[0],"network":[1,129],"cocast":[2],"(WNC)":[3],"is":[4,70,79],"a":[5,61,82],"cooperative":[6,75,83],"communication":[7],"protocol":[8],"that":[9,102],"overcomes":[10],"the":[11,86,128],"issues":[12],"of":[13,113,115],"imperfect":[14],"frequency":[15],"and":[16,39,48],"timing":[17],"synchronization":[18],"while":[19],"achieving":[20],"spatial":[21],"diversity":[22],"to":[23,33,72,89,97,109],"substantially":[24],"reduce":[25],"transmit":[26],"power":[27,36,90,95,108,124],"over":[28],"direct":[29],"transmission":[30],"(DTX).":[31],"Due":[32],"additional":[34,94],"processing":[35],"in":[37,52],"receiving":[38],"retransmitting":[40],"each":[41],"other":[42],"information,":[43],"however,":[44],"not":[45],"all":[46],"nodes":[47],"WNC":[49,59,103,120],"networks":[50,104,121],"result":[51],"energy":[53,57],"efficiency.":[54],"To":[55],"ensure":[56],"efficient":[58],"networks,":[60],"TDMA-based":[62],"merge":[63,87],"process":[64],"based":[65],"on":[66],"coalition":[67],"formation":[68],"games":[69],"proposed":[71],"orderly":[73],"form":[74],"groups.":[76],"A":[77],"node":[78],"merged":[80],"into":[81],"group":[84],"if":[85],"leads":[88],"saving":[91],"without":[92],"causing":[93],"burden":[96],"individual":[98],"nodes.":[99],"Simulation":[100],"shows":[101],"require":[105],"much":[106],"less":[107],"provide":[110],"comparable":[111],"quality":[112],"service":[114],"DTX":[116],"networks.":[117],"In":[118],"addition,":[119],"achieve":[122],"even":[123],"distribution,":[125],"which":[126],"improves":[127],"lifetime.":[130]},"counts_by_year":[],"updated_date":"2026-04-05T17:49:38.594831","created_date":"2025-10-10T00:00:00"}
