{"id":"https://openalex.org/W2057140097","doi":"https://doi.org/10.1109/memea.2013.6549763","title":"An automated test system for measuring and improving electrosurgical effects","display_name":"An automated test system for measuring and improving electrosurgical effects","publication_year":2013,"publication_date":"2013-05-01","ids":{"openalex":"https://openalex.org/W2057140097","doi":"https://doi.org/10.1109/memea.2013.6549763","mag":"2057140097"},"language":"en","primary_location":{"id":"doi:10.1109/memea.2013.6549763","is_oa":false,"landing_page_url":"https://doi.org/10.1109/memea.2013.6549763","pdf_url":null,"source":null,"license":null,"license_id":null,"version":"publishedVersion","is_accepted":true,"is_published":true,"raw_source_name":"2013 IEEE International Symposium on Medical Measurements and Applications (MeMeA)","raw_type":"proceedings-article"},"type":"article","indexed_in":["crossref"],"open_access":{"is_oa":true,"oa_status":"green","oa_url":"https://zenodo.org/record/1275449","any_repository_has_fulltext":true},"authorships":[{"author_position":"first","author":{"id":"https://openalex.org/A5052049763","display_name":"Abu El-Eyuoon Abu Zied Amin","orcid":"https://orcid.org/0000-0002-4915-9413"},"institutions":[{"id":"https://openalex.org/I189196454","display_name":"The University of Texas at Arlington","ror":"https://ror.org/019kgqr73","country_code":"US","type":"education","lineage":["https://openalex.org/I189196454"]}],"countries":["US"],"is_corresponding":true,"raw_author_name":"A. Amin","raw_affiliation_strings":["University of Texas at Arlington, Arlington, TX, US","[University of Texas at Arlington, Arlington, TX, USA]"],"affiliations":[{"raw_affiliation_string":"University of Texas at Arlington, Arlington, TX, US","institution_ids":["https://openalex.org/I189196454"]},{"raw_affiliation_string":"[University of Texas at Arlington, Arlington, TX, USA]","institution_ids":["https://openalex.org/I189196454"]}]},{"author_position":"middle","author":{"id":"https://openalex.org/A5019754462","display_name":"Daniel Friedrichs","orcid":"https://orcid.org/0000-0003-1102-4916"},"institutions":[{"id":"https://openalex.org/I4210133043","display_name":"Clinical Solutions","ror":"https://ror.org/02p9evb60","country_code":"US","type":"other","lineage":["https://openalex.org/I4210133043"]}],"countries":["US"],"is_corresponding":false,"raw_author_name":"D. Friedrichs","raw_affiliation_strings":["Covidien Surgical Solutions, Boulder, CO, USA","Covidien Surg. Solutions, Boulder, CO, USA"],"affiliations":[{"raw_affiliation_string":"Covidien Surgical Solutions, Boulder, CO, USA","institution_ids":["https://openalex.org/I4210133043"]},{"raw_affiliation_string":"Covidien Surg. Solutions, Boulder, CO, USA","institution_ids":[]}]},{"author_position":"middle","author":{"id":"https://openalex.org/A5037577218","display_name":"Carolyn Ford","orcid":null},"institutions":[{"id":"https://openalex.org/I4210133043","display_name":"Clinical Solutions","ror":"https://ror.org/02p9evb60","country_code":"US","type":"other","lineage":["https://openalex.org/I4210133043"]}],"countries":["US"],"is_corresponding":false,"raw_author_name":"C. Ford","raw_affiliation_strings":["Covidien Surgical Solutions, Boulder, CO, USA","Covidien Surg. Solutions, Boulder, CO, USA"],"affiliations":[{"raw_affiliation_string":"Covidien Surgical Solutions, Boulder, CO, USA","institution_ids":["https://openalex.org/I4210133043"]},{"raw_affiliation_string":"Covidien Surg. Solutions, Boulder, CO, USA","institution_ids":[]}]},{"author_position":"middle","author":{"id":"https://openalex.org/A5114105937","display_name":"Erik B. Larson","orcid":null},"institutions":[{"id":"https://openalex.org/I4210133043","display_name":"Clinical Solutions","ror":"https://ror.org/02p9evb60","country_code":"US","type":"other","lineage":["https://openalex.org/I4210133043"]}],"countries":["US"],"is_corresponding":false,"raw_author_name":"E. Larson","raw_affiliation_strings":["Covidien Surgical Solutions, Boulder, CO, USA","Covidien Surg. Solutions, Boulder, CO, USA"],"affiliations":[{"raw_affiliation_string":"Covidien Surgical Solutions, Boulder, CO, USA","institution_ids":["https://openalex.org/I4210133043"]},{"raw_affiliation_string":"Covidien Surg. Solutions, Boulder, CO, USA","institution_ids":[]}]},{"author_position":"last","author":{"id":"https://openalex.org/A5076736767","display_name":"James Gilbert","orcid":"https://orcid.org/0000-0001-8079-3159"},"institutions":[{"id":"https://openalex.org/I4210133043","display_name":"Clinical Solutions","ror":"https://ror.org/02p9evb60","country_code":"US","type":"other","lineage":["https://openalex.org/I4210133043"]}],"countries":["US"],"is_corresponding":false,"raw_author_name":"J. Gilbert","raw_affiliation_strings":["Covidien Surgical Solutions, Boulder, CO, USA","Covidien Surg. Solutions, Boulder, CO, USA"],"affiliations":[{"raw_affiliation_string":"Covidien Surgical Solutions, Boulder, CO, USA","institution_ids":["https://openalex.org/I4210133043"]},{"raw_affiliation_string":"Covidien Surg. Solutions, Boulder, CO, USA","institution_ids":[]}]}],"institutions":[],"countries_distinct_count":1,"institutions_distinct_count":5,"corresponding_author_ids":["https://openalex.org/A5052049763"],"corresponding_institution_ids":["https://openalex.org/I189196454"],"apc_list":null,"apc_paid":null,"fwci":0.0,"has_fulltext":false,"cited_by_count":1,"citation_normalized_percentile":{"value":0.11659423,"is_in_top_1_percent":false,"is_in_top_10_percent":false},"cited_by_percentile_year":{"min":90,"max":94},"biblio":{"volume":null,"issue":null,"first_page":"334","last_page":"338"},"is_retracted":false,"is_paratext":false,"is_xpac":false,"primary_topic":{"id":"https://openalex.org/T11249","display_name":"Wireless Power Transfer Systems","score":0.9559999704360962,"subfield":{"id":"https://openalex.org/subfields/2208","display_name":"Electrical and Electronic Engineering"},"field":{"id":"https://openalex.org/fields/22","display_name":"Engineering"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}},"topics":[{"id":"https://openalex.org/T11249","display_name":"Wireless Power Transfer Systems","score":0.9559999704360962,"subfield":{"id":"https://openalex.org/subfields/2208","display_name":"Electrical and Electronic Engineering"},"field":{"id":"https://openalex.org/fields/22","display_name":"Engineering"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}},{"id":"https://openalex.org/T11728","display_name":"Thyroid and Parathyroid Surgery","score":0.9298999905586243,"subfield":{"id":"https://openalex.org/subfields/2746","display_name":"Surgery"},"field":{"id":"https://openalex.org/fields/27","display_name":"Medicine"},"domain":{"id":"https://openalex.org/domains/4","display_name":"Health Sciences"}}],"keywords":[{"id":"https://openalex.org/keywords/electrosurgery","display_name":"Electrosurgery","score":0.6361641883850098},{"id":"https://openalex.org/keywords/computer-science","display_name":"Computer science","score":0.6313983201980591},{"id":"https://openalex.org/keywords/process","display_name":"Process (computing)","score":0.5343636274337769},{"id":"https://openalex.org/keywords/test","display_name":"Test (biology)","score":0.4843674600124359},{"id":"https://openalex.org/keywords/reliability-engineering","display_name":"Reliability engineering","score":0.45667195320129395},{"id":"https://openalex.org/keywords/systems-engineering","display_name":"Systems engineering","score":0.41409367322921753},{"id":"https://openalex.org/keywords/industrial-engineering","display_name":"Industrial engineering","score":0.33754464983940125},{"id":"https://openalex.org/keywords/engineering","display_name":"Engineering","score":0.2874411344528198},{"id":"https://openalex.org/keywords/electrical-engineering","display_name":"Electrical engineering","score":0.12911957502365112},{"id":"https://openalex.org/keywords/operating-system","display_name":"Operating system","score":0.08750176429748535}],"concepts":[{"id":"https://openalex.org/C2778842199","wikidata":"https://www.wikidata.org/wiki/Q1563560","display_name":"Electrosurgery","level":2,"score":0.6361641883850098},{"id":"https://openalex.org/C41008148","wikidata":"https://www.wikidata.org/wiki/Q21198","display_name":"Computer science","level":0,"score":0.6313983201980591},{"id":"https://openalex.org/C98045186","wikidata":"https://www.wikidata.org/wiki/Q205663","display_name":"Process (computing)","level":2,"score":0.5343636274337769},{"id":"https://openalex.org/C2777267654","wikidata":"https://www.wikidata.org/wiki/Q3519023","display_name":"Test (biology)","level":2,"score":0.4843674600124359},{"id":"https://openalex.org/C200601418","wikidata":"https://www.wikidata.org/wiki/Q2193887","display_name":"Reliability engineering","level":1,"score":0.45667195320129395},{"id":"https://openalex.org/C201995342","wikidata":"https://www.wikidata.org/wiki/Q682496","display_name":"Systems engineering","level":1,"score":0.41409367322921753},{"id":"https://openalex.org/C13736549","wikidata":"https://www.wikidata.org/wiki/Q4489420","display_name":"Industrial engineering","level":1,"score":0.33754464983940125},{"id":"https://openalex.org/C127413603","wikidata":"https://www.wikidata.org/wiki/Q11023","display_name":"Engineering","level":0,"score":0.2874411344528198},{"id":"https://openalex.org/C119599485","wikidata":"https://www.wikidata.org/wiki/Q43035","display_name":"Electrical engineering","level":1,"score":0.12911957502365112},{"id":"https://openalex.org/C111919701","wikidata":"https://www.wikidata.org/wiki/Q9135","display_name":"Operating system","level":1,"score":0.08750176429748535},{"id":"https://openalex.org/C86803240","wikidata":"https://www.wikidata.org/wiki/Q420","display_name":"Biology","level":0,"score":0.0},{"id":"https://openalex.org/C151730666","wikidata":"https://www.wikidata.org/wiki/Q7205","display_name":"Paleontology","level":1,"score":0.0}],"mesh":[],"locations_count":2,"locations":[{"id":"doi:10.1109/memea.2013.6549763","is_oa":false,"landing_page_url":"https://doi.org/10.1109/memea.2013.6549763","pdf_url":null,"source":null,"license":null,"license_id":null,"version":"publishedVersion","is_accepted":true,"is_published":true,"raw_source_name":"2013 IEEE International Symposium on Medical Measurements and Applications (MeMeA)","raw_type":"proceedings-article"},{"id":"pmh:oai:zenodo.org:1275449","is_oa":true,"landing_page_url":"https://zenodo.org/record/1275449","pdf_url":null,"source":{"id":"https://openalex.org/S4306400562","display_name":"Zenodo (CERN European Organization for Nuclear Research)","issn_l":null,"issn":null,"is_oa":true,"is_in_doaj":false,"is_core":false,"host_organization":"https://openalex.org/I67311998","host_organization_name":"European Organization for Nuclear Research","host_organization_lineage":["https://openalex.org/I67311998"],"host_organization_lineage_names":[],"type":"repository"},"license":"public-domain","license_id":"https://openalex.org/licenses/public-domain","version":"submittedVersion","is_accepted":false,"is_published":false,"raw_source_name":"","raw_type":"info:eu-repo/semantics/conferencePaper"}],"best_oa_location":{"id":"pmh:oai:zenodo.org:1275449","is_oa":true,"landing_page_url":"https://zenodo.org/record/1275449","pdf_url":null,"source":{"id":"https://openalex.org/S4306400562","display_name":"Zenodo (CERN European Organization for Nuclear Research)","issn_l":null,"issn":null,"is_oa":true,"is_in_doaj":false,"is_core":false,"host_organization":"https://openalex.org/I67311998","host_organization_name":"European Organization for Nuclear Research","host_organization_lineage":["https://openalex.org/I67311998"],"host_organization_lineage_names":[],"type":"repository"},"license":"public-domain","license_id":"https://openalex.org/licenses/public-domain","version":"submittedVersion","is_accepted":false,"is_published":false,"raw_source_name":"","raw_type":"info:eu-repo/semantics/conferencePaper"},"sustainable_development_goals":[{"id":"https://metadata.un.org/sdg/7","score":0.550000011920929,"display_name":"Affordable and clean energy"}],"awards":[],"funders":[],"has_content":{"pdf":false,"grobid_xml":false},"content_urls":null,"referenced_works_count":5,"referenced_works":["https://openalex.org/W1984182461","https://openalex.org/W2002061613","https://openalex.org/W2072665871","https://openalex.org/W2143653068","https://openalex.org/W2491764613"],"related_works":["https://openalex.org/W2102140470","https://openalex.org/W2055600812","https://openalex.org/W1942042441","https://openalex.org/W4244015577","https://openalex.org/W32056985","https://openalex.org/W2624904882","https://openalex.org/W2022920255","https://openalex.org/W3136498042","https://openalex.org/W2460780684","https://openalex.org/W2047451803"],"abstract_inverted_index":{"Designing":[0],"instruments":[1],"and":[2,53,67],"power":[3],"supplies":[4],"for":[5],"electrosurgery":[6],"(a":[7],"critical":[8],"tool":[9],"in":[10],"modern":[11],"surgical":[12],"practice)":[13],"is":[14],"a":[15,18,58],"difficult":[16],"proposition;":[17],"large":[19],"number":[20,28],"of":[21,29,38],"competing":[22],"variables":[23],"affect":[24],"an":[25,39],"even":[26],"larger":[27],"electrosurgical":[30],"performance":[31],"metrics.":[32],"This":[33],"paper":[34],"describes":[35],"the":[36,55,63],"design":[37,72],"apparatus":[40],"used":[41],"to":[42],"tightly":[43],"control":[44],"experimental":[45],"variables,":[46],"record":[47],"high-speed":[48],"data":[49],"from":[50],"numerous":[51],"sensors,":[52],"process":[54],"results":[56],"into":[57,70],"form":[59],"which":[60],"better":[61],"elucidates":[62],"underlying":[64],"physical":[65],"mechanisms":[66],"gives":[68],"insight":[69],"potential":[71],"improvements.":[73]},"counts_by_year":[{"year":2017,"cited_by_count":1}],"updated_date":"2026-03-20T23:20:44.827607","created_date":"2025-10-10T00:00:00"}