{"id":"https://openalex.org/W2737235972","doi":"https://doi.org/10.1109/med.2017.7984212","title":"Cascaded operation-mode-adaptive control for power conditioning systems with uninterruptible power supply capability","display_name":"Cascaded operation-mode-adaptive control for power conditioning systems with uninterruptible power supply capability","publication_year":2017,"publication_date":"2017-07-01","ids":{"openalex":"https://openalex.org/W2737235972","doi":"https://doi.org/10.1109/med.2017.7984212","mag":"2737235972"},"language":"en","primary_location":{"id":"doi:10.1109/med.2017.7984212","is_oa":false,"landing_page_url":"https://doi.org/10.1109/med.2017.7984212","pdf_url":null,"source":null,"license":null,"license_id":null,"version":"publishedVersion","is_accepted":true,"is_published":true,"raw_source_name":"2017 25th Mediterranean Conference on Control and Automation (MED)","raw_type":"proceedings-article"},"type":"article","indexed_in":["crossref"],"open_access":{"is_oa":false,"oa_status":"closed","oa_url":null,"any_repository_has_fulltext":false},"authorships":[{"author_position":"first","author":{"id":"https://openalex.org/A5004572382","display_name":"Florian Bendrat","orcid":"https://orcid.org/0000-0002-6308-8690"},"institutions":[{"id":"https://openalex.org/I904495901","display_name":"Ruhr University Bochum","ror":"https://ror.org/04tsk2644","country_code":"DE","type":"education","lineage":["https://openalex.org/I904495901"]}],"countries":["DE"],"is_corresponding":true,"raw_author_name":"Florian Bendrat","raw_affiliation_strings":["Department of Electrical Engineering and Information Technology, Ruhr-University Bochum, Bochum, Germany"],"affiliations":[{"raw_affiliation_string":"Department of Electrical Engineering and Information Technology, Ruhr-University Bochum, Bochum, Germany","institution_ids":["https://openalex.org/I904495901"]}]},{"author_position":"middle","author":{"id":"https://openalex.org/A5040862249","display_name":"Johnny Chhor","orcid":"https://orcid.org/0000-0001-8597-2658"},"institutions":[{"id":"https://openalex.org/I904495901","display_name":"Ruhr University Bochum","ror":"https://ror.org/04tsk2644","country_code":"DE","type":"education","lineage":["https://openalex.org/I904495901"]}],"countries":["DE"],"is_corresponding":false,"raw_author_name":"Johnny Chhor","raw_affiliation_strings":["Department of Electrical Engineering and Information Technology, Ruhr-University Bochum, Bochum, Germany"],"affiliations":[{"raw_affiliation_string":"Department of Electrical Engineering and Information Technology, Ruhr-University Bochum, Bochum, Germany","institution_ids":["https://openalex.org/I904495901"]}]},{"author_position":"last","author":{"id":"https://openalex.org/A5038189908","display_name":"Constantinos Sourkounis","orcid":"https://orcid.org/0000-0002-7340-1636"},"institutions":[{"id":"https://openalex.org/I904495901","display_name":"Ruhr University Bochum","ror":"https://ror.org/04tsk2644","country_code":"DE","type":"education","lineage":["https://openalex.org/I904495901"]}],"countries":["DE"],"is_corresponding":false,"raw_author_name":"Constantinos Sourkounis","raw_affiliation_strings":["Department of Electrical Engineering and Information Technology, Ruhr-University Bochum, Bochum, Germany"],"affiliations":[{"raw_affiliation_string":"Department of Electrical Engineering and Information Technology, Ruhr-University Bochum, Bochum, Germany","institution_ids":["https://openalex.org/I904495901"]}]}],"institutions":[],"countries_distinct_count":1,"institutions_distinct_count":3,"corresponding_author_ids":["https://openalex.org/A5004572382"],"corresponding_institution_ids":["https://openalex.org/I904495901"],"apc_list":null,"apc_paid":null,"fwci":0.8046,"has_fulltext":false,"cited_by_count":4,"citation_normalized_percentile":{"value":0.73693792,"is_in_top_1_percent":false,"is_in_top_10_percent":false},"cited_by_percentile_year":{"min":90,"max":97},"biblio":{"volume":null,"issue":null,"first_page":"774","last_page":"780"},"is_retracted":false,"is_paratext":false,"is_xpac":false,"primary_topic":{"id":"https://openalex.org/T10223","display_name":"Microgrid Control and Optimization","score":1.0,"subfield":{"id":"https://openalex.org/subfields/2207","display_name":"Control and Systems Engineering"},"field":{"id":"https://openalex.org/fields/22","display_name":"Engineering"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}},"topics":[{"id":"https://openalex.org/T10223","display_name":"Microgrid Control and Optimization","score":1.0,"subfield":{"id":"https://openalex.org/subfields/2207","display_name":"Control and Systems Engineering"},"field":{"id":"https://openalex.org/fields/22","display_name":"Engineering"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}},{"id":"https://openalex.org/T10573","display_name":"Power Quality and Harmonics","score":0.9991999864578247,"subfield":{"id":"https://openalex.org/subfields/2208","display_name":"Electrical and Electronic Engineering"},"field":{"id":"https://openalex.org/fields/22","display_name":"Engineering"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}},{"id":"https://openalex.org/T10603","display_name":"Smart Grid Energy Management","score":0.9991000294685364,"subfield":{"id":"https://openalex.org/subfields/2208","display_name":"Electrical and Electronic Engineering"},"field":{"id":"https://openalex.org/fields/22","display_name":"Engineering"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}}],"keywords":[{"id":"https://openalex.org/keywords/uninterruptible-power-supply","display_name":"Uninterruptible power supply","score":0.9352476596832275},{"id":"https://openalex.org/keywords/power-control","display_name":"Power control","score":0.5378227829933167},{"id":"https://openalex.org/keywords/modular-design","display_name":"Modular design","score":0.5283635258674622},{"id":"https://openalex.org/keywords/power-conditioner","display_name":"Power conditioner","score":0.49417784810066223},{"id":"https://openalex.org/keywords/power","display_name":"Power (physics)","score":0.4790140986442566},{"id":"https://openalex.org/keywords/grid","display_name":"Grid","score":0.4726499617099762},{"id":"https://openalex.org/keywords/computer-science","display_name":"Computer science","score":0.4485149681568146},{"id":"https://openalex.org/keywords/renewable-energy","display_name":"Renewable energy","score":0.43012842535972595},{"id":"https://openalex.org/keywords/engineering","display_name":"Engineering","score":0.4024052023887634},{"id":"https://openalex.org/keywords/automotive-engineering","display_name":"Automotive engineering","score":0.38536810874938965},{"id":"https://openalex.org/keywords/electronic-engineering","display_name":"Electronic engineering","score":0.36764025688171387},{"id":"https://openalex.org/keywords/reliability-engineering","display_name":"Reliability engineering","score":0.34213221073150635},{"id":"https://openalex.org/keywords/electrical-engineering","display_name":"Electrical engineering","score":0.32295751571655273},{"id":"https://openalex.org/keywords/ac-power","display_name":"AC power","score":0.29180675745010376},{"id":"https://openalex.org/keywords/voltage","display_name":"Voltage","score":0.21924251317977905}],"concepts":[{"id":"https://openalex.org/C2988808934","wikidata":"https://www.wikidata.org/wiki/Q207696","display_name":"Uninterruptible power supply","level":3,"score":0.9352476596832275},{"id":"https://openalex.org/C56685638","wikidata":"https://www.wikidata.org/wiki/Q2300474","display_name":"Power control","level":3,"score":0.5378227829933167},{"id":"https://openalex.org/C101468663","wikidata":"https://www.wikidata.org/wiki/Q1620158","display_name":"Modular design","level":2,"score":0.5283635258674622},{"id":"https://openalex.org/C2780765089","wikidata":"https://www.wikidata.org/wiki/Q1326101","display_name":"Power conditioner","level":4,"score":0.49417784810066223},{"id":"https://openalex.org/C163258240","wikidata":"https://www.wikidata.org/wiki/Q25342","display_name":"Power (physics)","level":2,"score":0.4790140986442566},{"id":"https://openalex.org/C187691185","wikidata":"https://www.wikidata.org/wiki/Q2020720","display_name":"Grid","level":2,"score":0.4726499617099762},{"id":"https://openalex.org/C41008148","wikidata":"https://www.wikidata.org/wiki/Q21198","display_name":"Computer science","level":0,"score":0.4485149681568146},{"id":"https://openalex.org/C188573790","wikidata":"https://www.wikidata.org/wiki/Q12705","display_name":"Renewable energy","level":2,"score":0.43012842535972595},{"id":"https://openalex.org/C127413603","wikidata":"https://www.wikidata.org/wiki/Q11023","display_name":"Engineering","level":0,"score":0.4024052023887634},{"id":"https://openalex.org/C171146098","wikidata":"https://www.wikidata.org/wiki/Q124192","display_name":"Automotive engineering","level":1,"score":0.38536810874938965},{"id":"https://openalex.org/C24326235","wikidata":"https://www.wikidata.org/wiki/Q126095","display_name":"Electronic engineering","level":1,"score":0.36764025688171387},{"id":"https://openalex.org/C200601418","wikidata":"https://www.wikidata.org/wiki/Q2193887","display_name":"Reliability engineering","level":1,"score":0.34213221073150635},{"id":"https://openalex.org/C119599485","wikidata":"https://www.wikidata.org/wiki/Q43035","display_name":"Electrical engineering","level":1,"score":0.32295751571655273},{"id":"https://openalex.org/C108755667","wikidata":"https://www.wikidata.org/wiki/Q1930258","display_name":"AC power","level":3,"score":0.29180675745010376},{"id":"https://openalex.org/C165801399","wikidata":"https://www.wikidata.org/wiki/Q25428","display_name":"Voltage","level":2,"score":0.21924251317977905},{"id":"https://openalex.org/C111919701","wikidata":"https://www.wikidata.org/wiki/Q9135","display_name":"Operating system","level":1,"score":0.0},{"id":"https://openalex.org/C33923547","wikidata":"https://www.wikidata.org/wiki/Q395","display_name":"Mathematics","level":0,"score":0.0},{"id":"https://openalex.org/C2524010","wikidata":"https://www.wikidata.org/wiki/Q8087","display_name":"Geometry","level":1,"score":0.0},{"id":"https://openalex.org/C62520636","wikidata":"https://www.wikidata.org/wiki/Q944","display_name":"Quantum mechanics","level":1,"score":0.0},{"id":"https://openalex.org/C121332964","wikidata":"https://www.wikidata.org/wiki/Q413","display_name":"Physics","level":0,"score":0.0}],"mesh":[],"locations_count":1,"locations":[{"id":"doi:10.1109/med.2017.7984212","is_oa":false,"landing_page_url":"https://doi.org/10.1109/med.2017.7984212","pdf_url":null,"source":null,"license":null,"license_id":null,"version":"publishedVersion","is_accepted":true,"is_published":true,"raw_source_name":"2017 25th Mediterranean Conference on Control and Automation (MED)","raw_type":"proceedings-article"}],"best_oa_location":null,"sustainable_development_goals":[{"score":0.8399999737739563,"display_name":"Affordable and clean energy","id":"https://metadata.un.org/sdg/7"}],"awards":[],"funders":[{"id":"https://openalex.org/F4320321114","display_name":"Bundesministerium f\u00fcr Bildung und Forschung","ror":"https://ror.org/04pz7b180"}],"has_content":{"grobid_xml":false,"pdf":false},"content_urls":null,"referenced_works_count":13,"referenced_works":["https://openalex.org/W1523872367","https://openalex.org/W1965095201","https://openalex.org/W1976113763","https://openalex.org/W2006445910","https://openalex.org/W2022180998","https://openalex.org/W2119120604","https://openalex.org/W2131191410","https://openalex.org/W2171230910","https://openalex.org/W2279582073","https://openalex.org/W2590458594","https://openalex.org/W3204083426","https://openalex.org/W6631100125","https://openalex.org/W6802375488"],"related_works":["https://openalex.org/W4361989019","https://openalex.org/W2378711340","https://openalex.org/W2728195845","https://openalex.org/W2978413108","https://openalex.org/W2352555376","https://openalex.org/W2010397900","https://openalex.org/W2737235972","https://openalex.org/W2772622743","https://openalex.org/W2556482352","https://openalex.org/W2167980904"],"abstract_inverted_index":{"The":[0,82],"growing":[1],"number":[2],"of":[3,16,67,85,97],"renewable":[4],"energy":[5],"sources":[6],"and":[7,40,64,90],"power":[8,25,30,38,53],"electronic":[9],"participants":[10],"are":[11],"increasingly":[12],"endangering":[13],"the":[14,52,86],"quality":[15,39,58],"supply":[17,31,41],"at":[18],"distribution":[19],"grid":[20],"level.":[21],"A":[22],"modular":[23],"shunt-connected":[24],"conditioning":[26,62],"system":[27,89],"featuring":[28],"uninterruptible":[29],"capability":[32],"is":[33,74,93],"proposed":[34],"to":[35,55],"locally":[36],"increase":[37],"reliability.":[42],"This":[43],"paper":[44],"proposes":[45],"an":[46],"operation-mode-adaptive":[47],"cascaded":[48],"control":[49,88],"strategy":[50],"enabling":[51],"conditioner":[54],"fulfill":[56],"respective":[57],"requirements":[59],"for":[60],"grid-connected":[61],"mode":[63,66],"island":[65],"operation.":[68],"Seamless":[69],"transition":[70],"between":[71],"both":[72],"modes":[73],"guaranteed":[75],"by":[76,95],"using":[77],"a":[78],"load-friendly":[79],"synchronization":[80],"strategy.":[81],"dynamic":[83],"performance":[84],"chosen":[87],"operation":[91],"management":[92],"evaluated":[94],"means":[96],"simulative":[98],"investigations.":[99]},"counts_by_year":[{"year":2018,"cited_by_count":1},{"year":2017,"cited_by_count":3}],"updated_date":"2025-11-06T03:46:38.306776","created_date":"2025-10-10T00:00:00"}