{"id":"https://openalex.org/W4411726887","doi":"https://doi.org/10.1109/meco66322.2025.11049255","title":"End-Winding Leakage Flux Monitoring for Stator Fault Detection in Induction Machines using Fiber Bragg Grating (FBG)-Terfenol-D Composite Sensors","display_name":"End-Winding Leakage Flux Monitoring for Stator Fault Detection in Induction Machines using Fiber Bragg Grating (FBG)-Terfenol-D Composite Sensors","publication_year":2025,"publication_date":"2025-06-10","ids":{"openalex":"https://openalex.org/W4411726887","doi":"https://doi.org/10.1109/meco66322.2025.11049255"},"language":"en","primary_location":{"id":"doi:10.1109/meco66322.2025.11049255","is_oa":false,"landing_page_url":"https://doi.org/10.1109/meco66322.2025.11049255","pdf_url":null,"source":null,"license":null,"license_id":null,"version":"publishedVersion","is_accepted":true,"is_published":true,"raw_source_name":"2025 14th Mediterranean Conference on Embedded Computing (MECO)","raw_type":"proceedings-article"},"type":"conference-paper","indexed_in":["crossref"],"open_access":{"is_oa":false,"oa_status":"closed","oa_url":null,"any_repository_has_fulltext":false},"authorships":[{"author_position":"first","author":{"id":"https://openalex.org/A5049947672","display_name":"Asep Andi Suryandi","orcid":"https://orcid.org/0000-0001-6685-9510"},"institutions":[],"countries":[],"is_corresponding":false,"raw_author_name":"Asep Andi Suryandi","raw_affiliation_strings":["National Research and Innovation Agency (BRIN),PRTIPM-OREM,Jakarta,Indonesia"],"raw_orcid":null,"affiliations":[{"raw_affiliation_string":"National Research and Innovation Agency (BRIN),PRTIPM-OREM,Jakarta,Indonesia","institution_ids":[]}]},{"author_position":"middle","author":{"id":"https://openalex.org/A5057559153","display_name":"Paul M. Tuohy","orcid":"https://orcid.org/0000-0001-9646-3832"},"institutions":[{"id":"https://openalex.org/I28407311","display_name":"University of Manchester","ror":"https://ror.org/027m9bs27","country_code":"GB","type":"education","lineage":["https://openalex.org/I28407311"]}],"countries":["GB"],"is_corresponding":false,"raw_author_name":"Paul Tuohy","raw_affiliation_strings":["The University of Manchester,Department of Electrical and Electronic Engineering,Manchester,UK"],"raw_orcid":null,"affiliations":[{"raw_affiliation_string":"The University of Manchester,Department of Electrical and Electronic Engineering,Manchester,UK","institution_ids":["https://openalex.org/I28407311"]}]},{"author_position":"last","author":{"id":"https://openalex.org/A5023381158","display_name":"Sini\u0161a Djurovi\u0107","orcid":"https://orcid.org/0000-0001-7700-6492"},"institutions":[{"id":"https://openalex.org/I28407311","display_name":"University of Manchester","ror":"https://ror.org/027m9bs27","country_code":"GB","type":"education","lineage":["https://openalex.org/I28407311"]}],"countries":["GB"],"is_corresponding":false,"raw_author_name":"Sini\u0161a Djurovi\u0107","raw_affiliation_strings":["The University of Manchester,Department of Electrical and Electronic Engineering,Manchester,UK"],"raw_orcid":null,"affiliations":[{"raw_affiliation_string":"The University of Manchester,Department of Electrical and Electronic Engineering,Manchester,UK","institution_ids":["https://openalex.org/I28407311"]}]}],"institutions":[],"countries_distinct_count":1,"institutions_distinct_count":1,"corresponding_author_ids":[],"corresponding_institution_ids":[],"apc_list":null,"apc_paid":null,"fwci":3.4704,"has_fulltext":false,"cited_by_count":1,"citation_normalized_percentile":{"value":0.88040103,"is_in_top_1_percent":false,"is_in_top_10_percent":false},"cited_by_percentile_year":{"min":91,"max":95},"biblio":{"volume":null,"issue":null,"first_page":"1","last_page":"7"},"is_retracted":false,"is_paratext":false,"is_xpac":false,"primary_topic":{"id":"https://openalex.org/T11343","display_name":"Power Transformer Diagnostics and Insulation","score":0.9678000211715698,"subfield":{"id":"https://openalex.org/subfields/2208","display_name":"Electrical and Electronic Engineering"},"field":{"id":"https://openalex.org/fields/22","display_name":"Engineering"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}},"topics":[{"id":"https://openalex.org/T11343","display_name":"Power Transformer Diagnostics and Insulation","score":0.9678000211715698,"subfield":{"id":"https://openalex.org/subfields/2208","display_name":"Electrical and Electronic Engineering"},"field":{"id":"https://openalex.org/fields/22","display_name":"Engineering"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}},{"id":"https://openalex.org/T12206","display_name":"Vibration and Dynamic Analysis","score":0.9660000205039978,"subfield":{"id":"https://openalex.org/subfields/2207","display_name":"Control and Systems Engineering"},"field":{"id":"https://openalex.org/fields/22","display_name":"Engineering"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}},{"id":"https://openalex.org/T10220","display_name":"Machine Fault Diagnosis Techniques","score":0.9315000176429749,"subfield":{"id":"https://openalex.org/subfields/2207","display_name":"Control and Systems Engineering"},"field":{"id":"https://openalex.org/fields/22","display_name":"Engineering"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}}],"keywords":[{"id":"https://openalex.org/keywords/fiber-bragg-grating","display_name":"Fiber Bragg grating","score":0.8495293855667114},{"id":"https://openalex.org/keywords/materials-science","display_name":"Materials science","score":0.6654065251350403},{"id":"https://openalex.org/keywords/stator","display_name":"Stator","score":0.6354506611824036},{"id":"https://openalex.org/keywords/composite-number","display_name":"Composite number","score":0.5404284000396729},{"id":"https://openalex.org/keywords/leakage","display_name":"Leakage (economics)","score":0.5238242745399475},{"id":"https://openalex.org/keywords/magnetic-flux-leakage","display_name":"Magnetic flux leakage","score":0.5178749561309814},{"id":"https://openalex.org/keywords/fault-detection-and-isolation","display_name":"Fault detection and isolation","score":0.4870648682117462},{"id":"https://openalex.org/keywords/fiber-optic-sensor","display_name":"Fiber optic sensor","score":0.43211978673934937},{"id":"https://openalex.org/keywords/grating","display_name":"Grating","score":0.41774463653564453},{"id":"https://openalex.org/keywords/optical-fiber","display_name":"Optical fiber","score":0.4150931239128113},{"id":"https://openalex.org/keywords/electromagnetic-coil","display_name":"Electromagnetic coil","score":0.33064109086990356},{"id":"https://openalex.org/keywords/optoelectronics","display_name":"Optoelectronics","score":0.29932737350463867},{"id":"https://openalex.org/keywords/fiber","display_name":"Fiber","score":0.28653448820114136},{"id":"https://openalex.org/keywords/optics","display_name":"Optics","score":0.27501732110977173},{"id":"https://openalex.org/keywords/composite-material","display_name":"Composite material","score":0.25349265336990356},{"id":"https://openalex.org/keywords/electrical-engineering","display_name":"Electrical engineering","score":0.1654549241065979},{"id":"https://openalex.org/keywords/engineering","display_name":"Engineering","score":0.13453355431556702},{"id":"https://openalex.org/keywords/physics","display_name":"Physics","score":0.11692658066749573},{"id":"https://openalex.org/keywords/actuator","display_name":"Actuator","score":0.0722404420375824}],"concepts":[{"id":"https://openalex.org/C43091971","wikidata":"https://www.wikidata.org/wiki/Q1397391","display_name":"Fiber Bragg grating","level":3,"score":0.8495293855667114},{"id":"https://openalex.org/C192562407","wikidata":"https://www.wikidata.org/wiki/Q228736","display_name":"Materials science","level":0,"score":0.6654065251350403},{"id":"https://openalex.org/C2776529397","wikidata":"https://www.wikidata.org/wiki/Q190312","display_name":"Stator","level":2,"score":0.6354506611824036},{"id":"https://openalex.org/C104779481","wikidata":"https://www.wikidata.org/wiki/Q50707","display_name":"Composite number","level":2,"score":0.5404284000396729},{"id":"https://openalex.org/C2777042071","wikidata":"https://www.wikidata.org/wiki/Q6509304","display_name":"Leakage (economics)","level":2,"score":0.5238242745399475},{"id":"https://openalex.org/C20892748","wikidata":"https://www.wikidata.org/wiki/Q4390394","display_name":"Magnetic flux leakage","level":3,"score":0.5178749561309814},{"id":"https://openalex.org/C152745839","wikidata":"https://www.wikidata.org/wiki/Q5438153","display_name":"Fault detection and isolation","level":3,"score":0.4870648682117462},{"id":"https://openalex.org/C21651689","wikidata":"https://www.wikidata.org/wiki/Q1397427","display_name":"Fiber optic sensor","level":3,"score":0.43211978673934937},{"id":"https://openalex.org/C2777813233","wikidata":"https://www.wikidata.org/wiki/Q1527816","display_name":"Grating","level":2,"score":0.41774463653564453},{"id":"https://openalex.org/C194232370","wikidata":"https://www.wikidata.org/wiki/Q162","display_name":"Optical fiber","level":2,"score":0.4150931239128113},{"id":"https://openalex.org/C30403606","wikidata":"https://www.wikidata.org/wiki/Q2981904","display_name":"Electromagnetic coil","level":2,"score":0.33064109086990356},{"id":"https://openalex.org/C49040817","wikidata":"https://www.wikidata.org/wiki/Q193091","display_name":"Optoelectronics","level":1,"score":0.29932737350463867},{"id":"https://openalex.org/C519885992","wikidata":"https://www.wikidata.org/wiki/Q161","display_name":"Fiber","level":2,"score":0.28653448820114136},{"id":"https://openalex.org/C120665830","wikidata":"https://www.wikidata.org/wiki/Q14620","display_name":"Optics","level":1,"score":0.27501732110977173},{"id":"https://openalex.org/C159985019","wikidata":"https://www.wikidata.org/wiki/Q181790","display_name":"Composite material","level":1,"score":0.25349265336990356},{"id":"https://openalex.org/C119599485","wikidata":"https://www.wikidata.org/wiki/Q43035","display_name":"Electrical engineering","level":1,"score":0.1654549241065979},{"id":"https://openalex.org/C127413603","wikidata":"https://www.wikidata.org/wiki/Q11023","display_name":"Engineering","level":0,"score":0.13453355431556702},{"id":"https://openalex.org/C121332964","wikidata":"https://www.wikidata.org/wiki/Q413","display_name":"Physics","level":0,"score":0.11692658066749573},{"id":"https://openalex.org/C172707124","wikidata":"https://www.wikidata.org/wiki/Q423488","display_name":"Actuator","level":2,"score":0.0722404420375824},{"id":"https://openalex.org/C139719470","wikidata":"https://www.wikidata.org/wiki/Q39680","display_name":"Macroeconomics","level":1,"score":0.0},{"id":"https://openalex.org/C6260449","wikidata":"https://www.wikidata.org/wiki/Q41364","display_name":"Wavelength","level":2,"score":0.0},{"id":"https://openalex.org/C162324750","wikidata":"https://www.wikidata.org/wiki/Q8134","display_name":"Economics","level":0,"score":0.0}],"mesh":[],"locations_count":2,"locations":[{"id":"doi:10.1109/meco66322.2025.11049255","is_oa":false,"landing_page_url":"https://doi.org/10.1109/meco66322.2025.11049255","pdf_url":null,"source":null,"license":null,"license_id":null,"version":"publishedVersion","is_accepted":true,"is_published":true,"raw_source_name":"2025 14th Mediterranean Conference on Embedded Computing (MECO)","raw_type":"proceedings-article"},{"id":"pmh:oai:pure.atira.dk:openaire_cris_publications/bbb76264-736b-404e-b3ee-4971b061f4da","is_oa":false,"landing_page_url":"https://research.manchester.ac.uk/en/publications/bbb76264-736b-404e-b3ee-4971b061f4da","pdf_url":null,"source":{"id":"https://openalex.org/S4306400662","display_name":"Research Explorer (The University of Manchester)","issn_l":null,"issn":null,"is_oa":false,"is_in_doaj":false,"is_core":false,"host_organization":"https://openalex.org/I28407311","host_organization_name":"University of Manchester","host_organization_lineage":["https://openalex.org/I28407311"],"host_organization_lineage_names":[],"type":"repository"},"license":null,"license_id":null,"version":"publishedVersion","is_accepted":true,"is_published":true,"raw_source_name":"Suryandi, A A, Tuohy, P & Durovic, S 2025, End-Winding Leakage Flux Monitoring for Stator Fault Detection in Induction Machines using Fiber Bragg Grating (FBG)-Terfenol-D Composite Sensors. in IEEE MECO (14th Mediterranean Conference on Embedded Computing). IEEE MECO (14th Mediterranean Conference on Embedded Computing) , Budva, Montenegro, 10/06/25.","raw_type":"info:eu-repo/semantics/conferenceObject"}],"best_oa_location":null,"sustainable_development_goals":[{"score":0.8399999737739563,"display_name":"Affordable and clean energy","id":"https://metadata.un.org/sdg/7"}],"awards":[],"funders":[{"id":"https://openalex.org/F4320323084","display_name":"Ministry of Finance","ror":"https://ror.org/02jnxpg76"}],"has_content":{"pdf":false,"grobid_xml":false},"content_urls":null,"referenced_works_count":24,"referenced_works":["https://openalex.org/W1508381292","https://openalex.org/W1511816136","https://openalex.org/W1584040213","https://openalex.org/W1978655391","https://openalex.org/W2072896013","https://openalex.org/W2098389818","https://openalex.org/W2101231451","https://openalex.org/W2113835869","https://openalex.org/W2126853551","https://openalex.org/W2143602060","https://openalex.org/W2151066929","https://openalex.org/W2326892665","https://openalex.org/W2329888565","https://openalex.org/W2789524316","https://openalex.org/W2884588443","https://openalex.org/W2977250818","https://openalex.org/W2982570814","https://openalex.org/W3002466428","https://openalex.org/W3083444278","https://openalex.org/W3112148998","https://openalex.org/W3114633309","https://openalex.org/W4212914375","https://openalex.org/W4285210209","https://openalex.org/W4403277653"],"related_works":["https://openalex.org/W2463721724","https://openalex.org/W2365148668","https://openalex.org/W2917685425","https://openalex.org/W3216900447","https://openalex.org/W2096440838","https://openalex.org/W3205454610","https://openalex.org/W3146793764","https://openalex.org/W2014016592","https://openalex.org/W2025425461","https://openalex.org/W2038705077"],"abstract_inverted_index":{"This":[0],"study":[1],"presents":[2],"an":[3],"approach":[4],"for":[5,68,76],"detecting":[6],"stator":[7,34,56],"faults":[8],"in":[9],"induction":[10,78],"machines":[11],"using":[12],"Fiber":[13],"Bragg":[14],"Grating":[15],"(FBG)":[16],"composite":[17,66],"Terfenol-D":[18],"sensors.":[19],"The":[20,58],"proposed":[21],"sensor":[22,67],"utilises":[23],"the":[24,46,61,64],"magnetostriction":[25],"effect":[26],"to":[27,49,55],"monitor":[28],"magnetic":[29],"flux":[30,40,71],"density":[31],"and":[32,73],"detect":[33,50],"electrical":[35],"unbalance":[36],"conditions":[37],"through":[38],"leakage":[39,70],"spectrum":[41,52],"analysis.":[42],"Experimental":[43],"results":[44],"demonstrate":[45],"sensor's":[47],"ability":[48,62],"frequency":[51],"changes":[53],"related":[54],"faults.":[57],"findings":[59],"highlight":[60],"of":[63],"FBG-Terfenol-D":[65],"in-situ":[69],"measurements":[72],"its":[74],"potential":[75],"monitoring":[77],"machine":[79],"health":[80],"under":[81],"various":[82],"load":[83],"conditions.":[84]},"counts_by_year":[{"year":2025,"cited_by_count":1}],"updated_date":"2026-07-29T14:22:42.915294","created_date":"2025-10-10T00:00:00"}
