{"id":"https://openalex.org/W2844173199","doi":"https://doi.org/10.1109/meco.2018.8405990","title":"Electromagnetic compatibility of medical devices: Effects in everyday healthcare environment","display_name":"Electromagnetic compatibility of medical devices: Effects in everyday healthcare environment","publication_year":2018,"publication_date":"2018-06-01","ids":{"openalex":"https://openalex.org/W2844173199","doi":"https://doi.org/10.1109/meco.2018.8405990","mag":"2844173199"},"language":"en","primary_location":{"id":"doi:10.1109/meco.2018.8405990","is_oa":false,"landing_page_url":"https://doi.org/10.1109/meco.2018.8405990","pdf_url":null,"source":null,"license":null,"license_id":null,"version":"publishedVersion","is_accepted":true,"is_published":true,"raw_source_name":"2018 7th Mediterranean Conference on Embedded Computing (MECO)","raw_type":"proceedings-article"},"type":"article","indexed_in":["crossref"],"open_access":{"is_oa":false,"oa_status":"closed","oa_url":null,"any_repository_has_fulltext":false},"authorships":[{"author_position":"first","author":{"id":"https://openalex.org/A5046603661","display_name":"Emina Kurta","orcid":null},"institutions":[{"id":"https://openalex.org/I51716468","display_name":"International Burch University","ror":"https://ror.org/040cm8d21","country_code":"BA","type":"education","lineage":["https://openalex.org/I51716468"]}],"countries":["BA"],"is_corresponding":true,"raw_author_name":"Emina Kurta","raw_affiliation_strings":["Genetics and Bioengineering, Lyoness Sarajevo International Burch University Sarajevo Bosnia and Herzegovina"],"affiliations":[{"raw_affiliation_string":"Genetics and Bioengineering, Lyoness Sarajevo International Burch University Sarajevo Bosnia and Herzegovina","institution_ids":["https://openalex.org/I51716468"]}]},{"author_position":"middle","author":{"id":"https://openalex.org/A5014834315","display_name":"\u017divorad Kova\u010devi\u0107","orcid":null},"institutions":[{"id":"https://openalex.org/I51716468","display_name":"International Burch University","ror":"https://ror.org/040cm8d21","country_code":"BA","type":"education","lineage":["https://openalex.org/I51716468"]}],"countries":["BA"],"is_corresponding":false,"raw_author_name":"Zivorad Kovacevic","raw_affiliation_strings":["Genetics and Bioengineering, Lyoness Sarajevo International Burch University Sarajevo Bosnia and Herzegovina"],"affiliations":[{"raw_affiliation_string":"Genetics and Bioengineering, Lyoness Sarajevo International Burch University Sarajevo Bosnia and Herzegovina","institution_ids":["https://openalex.org/I51716468"]}]},{"author_position":"middle","author":{"id":"https://openalex.org/A5110429324","display_name":"Lejla Gurbeta","orcid":null},"institutions":[{"id":"https://openalex.org/I51716468","display_name":"International Burch University","ror":"https://ror.org/040cm8d21","country_code":"BA","type":"education","lineage":["https://openalex.org/I51716468"]}],"countries":["BA"],"is_corresponding":false,"raw_author_name":"Lejla Gurbeta","raw_affiliation_strings":["International Burch University, Sarajevo"],"affiliations":[{"raw_affiliation_string":"International Burch University, Sarajevo","institution_ids":["https://openalex.org/I51716468"]}]},{"author_position":"last","author":{"id":"https://openalex.org/A5082472767","display_name":"Almir Badnjevi\u0107","orcid":"https://orcid.org/0000-0003-1265-1292"},"institutions":[{"id":"https://openalex.org/I52574355","display_name":"University of Biha\u0107","ror":"https://ror.org/03y601s20","country_code":"BA","type":"education","lineage":["https://openalex.org/I52574355"]}],"countries":["BA"],"is_corresponding":false,"raw_author_name":"Almir Badnjevic","raw_affiliation_strings":["Technical faculty Bihac, University of Bihac l"],"affiliations":[{"raw_affiliation_string":"Technical faculty Bihac, University of Bihac l","institution_ids":["https://openalex.org/I52574355"]}]}],"institutions":[],"countries_distinct_count":1,"institutions_distinct_count":4,"corresponding_author_ids":["https://openalex.org/A5046603661"],"corresponding_institution_ids":["https://openalex.org/I51716468"],"apc_list":null,"apc_paid":null,"fwci":3.8018,"has_fulltext":false,"cited_by_count":7,"citation_normalized_percentile":{"value":0.93905817,"is_in_top_1_percent":false,"is_in_top_10_percent":true},"cited_by_percentile_year":{"min":89,"max":96},"biblio":{"volume":null,"issue":null,"first_page":"1","last_page":"4"},"is_retracted":false,"is_paratext":false,"is_xpac":false,"primary_topic":{"id":"https://openalex.org/T13690","display_name":"Quality and Safety in Healthcare","score":0.9997000098228455,"subfield":{"id":"https://openalex.org/subfields/3607","display_name":"Medical Laboratory Technology"},"field":{"id":"https://openalex.org/fields/36","display_name":"Health Professions"},"domain":{"id":"https://openalex.org/domains/4","display_name":"Health Sciences"}},"topics":[{"id":"https://openalex.org/T13690","display_name":"Quality and Safety in Healthcare","score":0.9997000098228455,"subfield":{"id":"https://openalex.org/subfields/3607","display_name":"Medical Laboratory Technology"},"field":{"id":"https://openalex.org/fields/36","display_name":"Health Professions"},"domain":{"id":"https://openalex.org/domains/4","display_name":"Health Sciences"}},{"id":"https://openalex.org/T13280","display_name":"Biomedical and Engineering Education","score":0.9919000267982483,"subfield":{"id":"https://openalex.org/subfields/2204","display_name":"Biomedical Engineering"},"field":{"id":"https://openalex.org/fields/22","display_name":"Engineering"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}},{"id":"https://openalex.org/T13248","display_name":"Healthcare Technology and Patient Monitoring","score":0.9485999941825867,"subfield":{"id":"https://openalex.org/subfields/2746","display_name":"Surgery"},"field":{"id":"https://openalex.org/fields/27","display_name":"Medicine"},"domain":{"id":"https://openalex.org/domains/4","display_name":"Health Sciences"}}],"keywords":[{"id":"https://openalex.org/keywords/electromagnetic-compatibility","display_name":"Electromagnetic compatibility","score":0.9062543511390686},{"id":"https://openalex.org/keywords/electromagnetic-interference","display_name":"Electromagnetic interference","score":0.8790788650512695},{"id":"https://openalex.org/keywords/emi","display_name":"EMI","score":0.8666846752166748},{"id":"https://openalex.org/keywords/medical-equipment","display_name":"Medical equipment","score":0.5920462012290955},{"id":"https://openalex.org/keywords/medical-device","display_name":"Medical device","score":0.5136155486106873},{"id":"https://openalex.org/keywords/electronics","display_name":"Electronics","score":0.5029820799827576},{"id":"https://openalex.org/keywords/computer-science","display_name":"Computer science","score":0.4990863800048828},{"id":"https://openalex.org/keywords/reliability","display_name":"Reliability (semiconductor)","score":0.47924140095710754},{"id":"https://openalex.org/keywords/electrical-engineering","display_name":"Electrical engineering","score":0.4484793543815613},{"id":"https://openalex.org/keywords/interference","display_name":"Interference (communication)","score":0.4279623031616211},{"id":"https://openalex.org/keywords/electromagnetic-environment","display_name":"Electromagnetic environment","score":0.4106999635696411},{"id":"https://openalex.org/keywords/reliability-engineering","display_name":"Reliability engineering","score":0.38933926820755005},{"id":"https://openalex.org/keywords/electronic-engineering","display_name":"Electronic engineering","score":0.35798409581184387},{"id":"https://openalex.org/keywords/engineering","display_name":"Engineering","score":0.26305124163627625},{"id":"https://openalex.org/keywords/telecommunications","display_name":"Telecommunications","score":0.2629307508468628},{"id":"https://openalex.org/keywords/biomedical-engineering","display_name":"Biomedical engineering","score":0.23483511805534363},{"id":"https://openalex.org/keywords/medicine","display_name":"Medicine","score":0.20970097184181213},{"id":"https://openalex.org/keywords/physics","display_name":"Physics","score":0.09658461809158325}],"concepts":[{"id":"https://openalex.org/C125470083","wikidata":"https://www.wikidata.org/wiki/Q747288","display_name":"Electromagnetic compatibility","level":2,"score":0.9062543511390686},{"id":"https://openalex.org/C184892835","wikidata":"https://www.wikidata.org/wiki/Q1474513","display_name":"Electromagnetic interference","level":2,"score":0.8790788650512695},{"id":"https://openalex.org/C43461449","wikidata":"https://www.wikidata.org/wiki/Q2495531","display_name":"EMI","level":3,"score":0.8666846752166748},{"id":"https://openalex.org/C513323569","wikidata":"https://www.wikidata.org/wiki/Q6554101","display_name":"Medical equipment","level":2,"score":0.5920462012290955},{"id":"https://openalex.org/C3020535179","wikidata":"https://www.wikidata.org/wiki/Q6554101","display_name":"Medical device","level":2,"score":0.5136155486106873},{"id":"https://openalex.org/C138331895","wikidata":"https://www.wikidata.org/wiki/Q11650","display_name":"Electronics","level":2,"score":0.5029820799827576},{"id":"https://openalex.org/C41008148","wikidata":"https://www.wikidata.org/wiki/Q21198","display_name":"Computer science","level":0,"score":0.4990863800048828},{"id":"https://openalex.org/C43214815","wikidata":"https://www.wikidata.org/wiki/Q7310987","display_name":"Reliability (semiconductor)","level":3,"score":0.47924140095710754},{"id":"https://openalex.org/C119599485","wikidata":"https://www.wikidata.org/wiki/Q43035","display_name":"Electrical engineering","level":1,"score":0.4484793543815613},{"id":"https://openalex.org/C32022120","wikidata":"https://www.wikidata.org/wiki/Q797225","display_name":"Interference (communication)","level":3,"score":0.4279623031616211},{"id":"https://openalex.org/C64183698","wikidata":"https://www.wikidata.org/wiki/Q4530886","display_name":"Electromagnetic environment","level":2,"score":0.4106999635696411},{"id":"https://openalex.org/C200601418","wikidata":"https://www.wikidata.org/wiki/Q2193887","display_name":"Reliability engineering","level":1,"score":0.38933926820755005},{"id":"https://openalex.org/C24326235","wikidata":"https://www.wikidata.org/wiki/Q126095","display_name":"Electronic engineering","level":1,"score":0.35798409581184387},{"id":"https://openalex.org/C127413603","wikidata":"https://www.wikidata.org/wiki/Q11023","display_name":"Engineering","level":0,"score":0.26305124163627625},{"id":"https://openalex.org/C76155785","wikidata":"https://www.wikidata.org/wiki/Q418","display_name":"Telecommunications","level":1,"score":0.2629307508468628},{"id":"https://openalex.org/C136229726","wikidata":"https://www.wikidata.org/wiki/Q327092","display_name":"Biomedical engineering","level":1,"score":0.23483511805534363},{"id":"https://openalex.org/C71924100","wikidata":"https://www.wikidata.org/wiki/Q11190","display_name":"Medicine","level":0,"score":0.20970097184181213},{"id":"https://openalex.org/C121332964","wikidata":"https://www.wikidata.org/wiki/Q413","display_name":"Physics","level":0,"score":0.09658461809158325},{"id":"https://openalex.org/C159110408","wikidata":"https://www.wikidata.org/wiki/Q121176","display_name":"Nursing","level":1,"score":0.0},{"id":"https://openalex.org/C62520636","wikidata":"https://www.wikidata.org/wiki/Q944","display_name":"Quantum mechanics","level":1,"score":0.0},{"id":"https://openalex.org/C163258240","wikidata":"https://www.wikidata.org/wiki/Q25342","display_name":"Power (physics)","level":2,"score":0.0},{"id":"https://openalex.org/C127162648","wikidata":"https://www.wikidata.org/wiki/Q16858953","display_name":"Channel (broadcasting)","level":2,"score":0.0}],"mesh":[],"locations_count":1,"locations":[{"id":"doi:10.1109/meco.2018.8405990","is_oa":false,"landing_page_url":"https://doi.org/10.1109/meco.2018.8405990","pdf_url":null,"source":null,"license":null,"license_id":null,"version":"publishedVersion","is_accepted":true,"is_published":true,"raw_source_name":"2018 7th Mediterranean Conference on Embedded Computing (MECO)","raw_type":"proceedings-article"}],"best_oa_location":null,"sustainable_development_goals":[],"awards":[],"funders":[],"has_content":{"grobid_xml":false,"pdf":false},"content_urls":null,"referenced_works_count":13,"referenced_works":["https://openalex.org/W1526600937","https://openalex.org/W1998636579","https://openalex.org/W2004583800","https://openalex.org/W2025569906","https://openalex.org/W2039823793","https://openalex.org/W2063299050","https://openalex.org/W2065119946","https://openalex.org/W2083617531","https://openalex.org/W2123188911","https://openalex.org/W2270363415","https://openalex.org/W2604877023","https://openalex.org/W2625752443","https://openalex.org/W6739531632"],"related_works":["https://openalex.org/W2041511579","https://openalex.org/W1921091955","https://openalex.org/W2535925839","https://openalex.org/W2124450871","https://openalex.org/W1986241886","https://openalex.org/W2358021413","https://openalex.org/W2076345965","https://openalex.org/W2540407017","https://openalex.org/W2160921373","https://openalex.org/W2071764837"],"abstract_inverted_index":{"This":[0],"paper":[1],"presents":[2],"an":[3],"overview":[4],"of":[5,14,42,55,65,68,77,89,117,122,134,171,176],"a":[6,86,126],"study":[7],"in":[8,30,52,107,114,131,142],"which":[9,150,182],"the":[10,22,31,38,53,66,72,75,135,146,183],"immunity":[11,164],"and":[12,40,83,119,165],"susceptibility":[13],"life-supporting":[15],"medical":[16,44,69,90,154,172],"equipment":[17,23],"was":[18,112,129],"evaluated":[19],"by":[20],"exposing":[21],"to":[24,36,103,158,181],"electromagnetic":[25,59,178],"interference":[26,128],"(EMI).":[27],"Electromagnetic":[28],"interference,":[29],"past,":[32],"has":[33,48],"been":[34,49],"proven":[35],"influence":[37,76],"activity":[39],"reliability":[41],"certain":[43],"devices.":[45,70],"Since":[46],"there":[47],"dramatic":[50],"increase":[51],"use":[54],"cellular":[56,78,104],"phones,":[57],"these":[58],"emitting":[60],"devices":[61,91,97,155,173,184],"have":[62],"become":[63],"part":[64],"environment":[67],"In":[71,94],"present":[73],"paper,":[74],"phones":[79,105],"at":[80],"various":[81,136],"distances":[82],"proportions":[84],"on":[85],"wide":[87],"range":[88],"were":[92,98,148],"studied.":[93],"total":[95],"136":[96,124],"tested":[99],"after":[100],"being":[101],"exposed":[102],"working":[106],"different":[108],"operating":[109],"modes.":[110],"Testing":[111],"performed":[113],"Healthcare":[115],"institutions":[116],"Bosnia":[118],"Herzegovina.":[120],"Out":[121],"all":[123],"devices,":[125],"significant":[127],"detected":[130],"only":[132],"one":[133],"defibrillators":[137],"tested.":[138],"Other":[139],"EMI":[140],"encountered":[141],"two":[143],"electrocardiograms,":[144],"during":[145],"tests,":[147],"negligible":[149],"proves":[151],"that":[152],"current":[153],"are":[156,174],"designed":[157],"operate":[159],"more":[160],"safely,":[161],"with":[162],"higher":[163],"lower":[166],"susceptibility.":[167],"The":[168],"improved":[169],"designs":[170],"results":[175],"strict":[177],"compatibility":[179],"standards":[180],"must":[185],"comply.":[186]},"counts_by_year":[{"year":2024,"cited_by_count":2},{"year":2023,"cited_by_count":1},{"year":2021,"cited_by_count":1},{"year":2020,"cited_by_count":1},{"year":2019,"cited_by_count":2}],"updated_date":"2025-11-06T03:46:38.306776","created_date":"2025-10-10T00:00:00"}
