{"id":"https://openalex.org/W2481270628","doi":"https://doi.org/10.1109/meco.2016.7525684","title":"New approaches to maintenance procedures of medical devices with measuring functions","display_name":"New approaches to maintenance procedures of medical devices with measuring functions","publication_year":2016,"publication_date":"2016-06-01","ids":{"openalex":"https://openalex.org/W2481270628","doi":"https://doi.org/10.1109/meco.2016.7525684","mag":"2481270628"},"language":"en","primary_location":{"id":"doi:10.1109/meco.2016.7525684","is_oa":true,"landing_page_url":"https://doi.org/10.1109/meco.2016.7525684","pdf_url":"https://ieeexplore.ieee.org/ielx7/7513174/7525673/07525684.pdf","source":null,"license":null,"license_id":null,"version":"publishedVersion","is_accepted":true,"is_published":true,"raw_source_name":"2016 5th Mediterranean Conference on Embedded Computing (MECO)","raw_type":"proceedings-article"},"type":"article","indexed_in":["crossref"],"open_access":{"is_oa":true,"oa_status":"gold","oa_url":"https://ieeexplore.ieee.org/ielx7/7513174/7525673/07525684.pdf","any_repository_has_fulltext":null},"authorships":[{"author_position":"first","author":{"id":"https://openalex.org/A5082472767","display_name":"Almir Badnjevi\u0107","orcid":"https://orcid.org/0000-0003-1265-1292"},"institutions":[{"id":"https://openalex.org/I51716468","display_name":"International Burch University","ror":"https://ror.org/040cm8d21","country_code":"BA","type":"education","lineage":["https://openalex.org/I51716468"]}],"countries":["BA"],"is_corresponding":true,"raw_author_name":"Almir Badnjevic\u0301","raw_affiliation_strings":["Department of Genetics and Bioengineering, International Burch University, Sarajevo, Bosnia and Herzegovina"],"affiliations":[{"raw_affiliation_string":"Department of Genetics and Bioengineering, International Burch University, Sarajevo, Bosnia and Herzegovina","institution_ids":["https://openalex.org/I51716468"]}]}],"institutions":[],"countries_distinct_count":1,"institutions_distinct_count":1,"corresponding_author_ids":["https://openalex.org/A5082472767"],"corresponding_institution_ids":["https://openalex.org/I51716468"],"apc_list":null,"apc_paid":null,"fwci":0.0,"has_fulltext":false,"cited_by_count":0,"citation_normalized_percentile":{"value":0.11890244,"is_in_top_1_percent":false,"is_in_top_10_percent":false},"cited_by_percentile_year":null,"biblio":{"volume":null,"issue":null,"first_page":"13","last_page":"13"},"is_retracted":false,"is_paratext":false,"is_xpac":false,"primary_topic":{"id":"https://openalex.org/T13690","display_name":"Quality and Safety in Healthcare","score":0.9929999709129333,"subfield":{"id":"https://openalex.org/subfields/3607","display_name":"Medical Laboratory Technology"},"field":{"id":"https://openalex.org/fields/36","display_name":"Health Professions"},"domain":{"id":"https://openalex.org/domains/4","display_name":"Health Sciences"}},"topics":[{"id":"https://openalex.org/T13690","display_name":"Quality and Safety in Healthcare","score":0.9929999709129333,"subfield":{"id":"https://openalex.org/subfields/3607","display_name":"Medical Laboratory Technology"},"field":{"id":"https://openalex.org/fields/36","display_name":"Health Professions"},"domain":{"id":"https://openalex.org/domains/4","display_name":"Health Sciences"}}],"keywords":[{"id":"https://openalex.org/keywords/medical-equipment","display_name":"Medical equipment","score":0.7095080018043518},{"id":"https://openalex.org/keywords/reliability-engineering","display_name":"Reliability engineering","score":0.5894281268119812},{"id":"https://openalex.org/keywords/reliability","display_name":"Reliability (semiconductor)","score":0.5809193253517151},{"id":"https://openalex.org/keywords/directive","display_name":"Directive","score":0.5733044743537903},{"id":"https://openalex.org/keywords/risk-analysis","display_name":"Risk analysis (engineering)","score":0.5629887580871582},{"id":"https://openalex.org/keywords/service","display_name":"Service (business)","score":0.5308844447135925},{"id":"https://openalex.org/keywords/process","display_name":"Process (computing)","score":0.4737033545970917},{"id":"https://openalex.org/keywords/computer-science","display_name":"Computer science","score":0.41951674222946167},{"id":"https://openalex.org/keywords/order","display_name":"Order (exchange)","score":0.41033393144607544},{"id":"https://openalex.org/keywords/operations-management","display_name":"Operations management","score":0.3330247402191162},{"id":"https://openalex.org/keywords/business","display_name":"Business","score":0.3240296244621277},{"id":"https://openalex.org/keywords/engineering","display_name":"Engineering","score":0.2485005259513855},{"id":"https://openalex.org/keywords/medicine","display_name":"Medicine","score":0.16839194297790527}],"concepts":[{"id":"https://openalex.org/C513323569","wikidata":"https://www.wikidata.org/wiki/Q6554101","display_name":"Medical equipment","level":2,"score":0.7095080018043518},{"id":"https://openalex.org/C200601418","wikidata":"https://www.wikidata.org/wiki/Q2193887","display_name":"Reliability engineering","level":1,"score":0.5894281268119812},{"id":"https://openalex.org/C43214815","wikidata":"https://www.wikidata.org/wiki/Q7310987","display_name":"Reliability (semiconductor)","level":3,"score":0.5809193253517151},{"id":"https://openalex.org/C2779547435","wikidata":"https://www.wikidata.org/wiki/Q1121492","display_name":"Directive","level":2,"score":0.5733044743537903},{"id":"https://openalex.org/C112930515","wikidata":"https://www.wikidata.org/wiki/Q4389547","display_name":"Risk analysis (engineering)","level":1,"score":0.5629887580871582},{"id":"https://openalex.org/C2780378061","wikidata":"https://www.wikidata.org/wiki/Q25351891","display_name":"Service (business)","level":2,"score":0.5308844447135925},{"id":"https://openalex.org/C98045186","wikidata":"https://www.wikidata.org/wiki/Q205663","display_name":"Process (computing)","level":2,"score":0.4737033545970917},{"id":"https://openalex.org/C41008148","wikidata":"https://www.wikidata.org/wiki/Q21198","display_name":"Computer science","level":0,"score":0.41951674222946167},{"id":"https://openalex.org/C182306322","wikidata":"https://www.wikidata.org/wiki/Q1779371","display_name":"Order (exchange)","level":2,"score":0.41033393144607544},{"id":"https://openalex.org/C21547014","wikidata":"https://www.wikidata.org/wiki/Q1423657","display_name":"Operations management","level":1,"score":0.3330247402191162},{"id":"https://openalex.org/C144133560","wikidata":"https://www.wikidata.org/wiki/Q4830453","display_name":"Business","level":0,"score":0.3240296244621277},{"id":"https://openalex.org/C127413603","wikidata":"https://www.wikidata.org/wiki/Q11023","display_name":"Engineering","level":0,"score":0.2485005259513855},{"id":"https://openalex.org/C71924100","wikidata":"https://www.wikidata.org/wiki/Q11190","display_name":"Medicine","level":0,"score":0.16839194297790527},{"id":"https://openalex.org/C159110408","wikidata":"https://www.wikidata.org/wiki/Q121176","display_name":"Nursing","level":1,"score":0.0},{"id":"https://openalex.org/C121332964","wikidata":"https://www.wikidata.org/wiki/Q413","display_name":"Physics","level":0,"score":0.0},{"id":"https://openalex.org/C10138342","wikidata":"https://www.wikidata.org/wiki/Q43015","display_name":"Finance","level":1,"score":0.0},{"id":"https://openalex.org/C163258240","wikidata":"https://www.wikidata.org/wiki/Q25342","display_name":"Power (physics)","level":2,"score":0.0},{"id":"https://openalex.org/C111919701","wikidata":"https://www.wikidata.org/wiki/Q9135","display_name":"Operating system","level":1,"score":0.0},{"id":"https://openalex.org/C162853370","wikidata":"https://www.wikidata.org/wiki/Q39809","display_name":"Marketing","level":1,"score":0.0},{"id":"https://openalex.org/C199360897","wikidata":"https://www.wikidata.org/wiki/Q9143","display_name":"Programming language","level":1,"score":0.0},{"id":"https://openalex.org/C62520636","wikidata":"https://www.wikidata.org/wiki/Q944","display_name":"Quantum mechanics","level":1,"score":0.0}],"mesh":[],"locations_count":1,"locations":[{"id":"doi:10.1109/meco.2016.7525684","is_oa":true,"landing_page_url":"https://doi.org/10.1109/meco.2016.7525684","pdf_url":"https://ieeexplore.ieee.org/ielx7/7513174/7525673/07525684.pdf","source":null,"license":null,"license_id":null,"version":"publishedVersion","is_accepted":true,"is_published":true,"raw_source_name":"2016 5th Mediterranean Conference on Embedded Computing (MECO)","raw_type":"proceedings-article"}],"best_oa_location":{"id":"doi:10.1109/meco.2016.7525684","is_oa":true,"landing_page_url":"https://doi.org/10.1109/meco.2016.7525684","pdf_url":"https://ieeexplore.ieee.org/ielx7/7513174/7525673/07525684.pdf","source":null,"license":null,"license_id":null,"version":"publishedVersion","is_accepted":true,"is_published":true,"raw_source_name":"2016 5th Mediterranean Conference on Embedded Computing (MECO)","raw_type":"proceedings-article"},"sustainable_development_goals":[],"awards":[],"funders":[],"has_content":{"pdf":true,"grobid_xml":true},"content_urls":{"pdf":"https://content.openalex.org/works/W2481270628.pdf","grobid_xml":"https://content.openalex.org/works/W2481270628.grobid-xml"},"referenced_works_count":0,"referenced_works":[],"related_works":["https://openalex.org/W2033512842","https://openalex.org/W4322734194","https://openalex.org/W3005535424","https://openalex.org/W4233600955","https://openalex.org/W2913665393","https://openalex.org/W2369695847","https://openalex.org/W2994319598","https://openalex.org/W2047067935","https://openalex.org/W1607054433","https://openalex.org/W2110842462"],"abstract_inverted_index":{"Medical":[0],"devices":[1,30,85,197],"with":[2,198],"measuring":[3],"functions":[4,200],"play":[5],"a":[6],"crucial":[7],"role":[8],"in":[9,27,43,86,176,239],"diagnostics":[10],"and":[11,22,46,68,81,99,184,212,222,243,245,249],"treatment":[12],"of":[13,55,74,83,90,123,128,135,141,169,195],"patients":[14],"is":[15,150],"health":[16],"care":[17],"establishments.":[18,109],"Both":[19],"the":[20,28,37,56,66,75,79,87,112,132,136,139,147,156,166,174,185,210,227],"testing":[21],"manufacturing":[23,67,215],"guidelines":[24,57],"laid":[25],"out":[26],"medical":[29,41,84,196,219,240],"directive":[31],"MDD":[32],"93/42,":[33],"as":[34,36,72],"well":[35,71],"recommendations":[38],"for":[39,138],"electrical":[40],"equipment":[42,158],"IEC":[44,47],"60601":[45],"62353":[48],"are":[49,59,62,92,127],"largely":[50],"not":[51,93,120,154,224],"implemented.":[52],"The":[53,96],"majority":[54],"that":[58,151,214],"being":[60],"followed":[61],"those":[63,107],"relating":[64],"to":[65,106,131,160,173,178,190,202,230],"selling":[69],"(as":[70],"obtaining":[73],"CE":[76],"mark),":[77],"while":[78,111],"precision":[80],"accuracy":[82],"subsequent":[88],"period":[89],"use":[91],"sufficiently":[94],"monitored.":[95],"manufacturers,":[97],"distributors":[98],"servicing":[100,148],"companies":[101,149,216],"do":[102,153],"provide":[103],"yearly":[104],"service":[105,114],"contracted":[108],"However,":[110],"aforementioned":[113],"includes":[115],"part":[116],"replacement,":[117],"it":[118,234],"does":[119],"include":[121],"measurements":[122],"output":[124],"parameters":[125,145],"which":[126],"vital":[129],"interest":[130],"patients.":[133],"Part":[134],"reason":[137],"lack":[140],"focus":[142],"on":[143],"exit":[144],"by":[146],"they":[152],"possess":[155],"necessary":[157],"needed":[159],"perform":[161,191],"said":[162],"tasks,":[163],"thereby":[164,223],"compromising":[165],"entire":[167],"process":[168],"preventative":[170],"maintenance.":[171],"Due":[172],"aforementioned,":[175],"order":[177],"regulate":[179],"this":[180],"domain,":[181],"state":[182],"agencies":[183],"affiliated":[186],"measurement":[187,199],"laboratories":[188],"ought":[189],"independent":[192],"inspection":[193],"(verification)":[194],"according":[201],"ISO":[203],"17020":[204],"standards.":[205],"This":[206],"would":[207,235],"effectively":[208],"abolish":[209],"lobby":[211],"monopoly":[213],"hold":[217],"over":[218],"device":[220,241],"repair":[221],"only":[225],"lower":[226],"cost":[228],"due":[229],"unnecessary":[231],"servicing,":[232],"but":[233],"ensure":[236],"an":[237],"increase":[238],"reliability":[242],"safety":[244],"ultimately":[246],"patient":[247],"diagnosis":[248],"treatment.":[250]},"counts_by_year":[],"updated_date":"2025-11-06T03:46:38.306776","created_date":"2025-10-10T00:00:00"}
