{"id":"https://openalex.org/W1561567108","doi":"https://doi.org/10.1109/meco.2015.7181945","title":"Medical devices in legal metrology","display_name":"Medical devices in legal metrology","publication_year":2015,"publication_date":"2015-06-01","ids":{"openalex":"https://openalex.org/W1561567108","doi":"https://doi.org/10.1109/meco.2015.7181945","mag":"1561567108"},"language":"en","primary_location":{"id":"doi:10.1109/meco.2015.7181945","is_oa":false,"landing_page_url":"https://doi.org/10.1109/meco.2015.7181945","pdf_url":null,"source":null,"license":null,"license_id":null,"version":"publishedVersion","is_accepted":true,"is_published":true,"raw_source_name":"2015 4th Mediterranean Conference on Embedded Computing (MECO)","raw_type":"proceedings-article"},"type":"article","indexed_in":["crossref"],"open_access":{"is_oa":false,"oa_status":"closed","oa_url":null,"any_repository_has_fulltext":false},"authorships":[{"author_position":"first","author":{"id":"https://openalex.org/A5082472767","display_name":"Almir Badnjevi\u0107","orcid":"https://orcid.org/0000-0003-1265-1292"},"institutions":[{"id":"https://openalex.org/I4210117113","display_name":"Verlab (Bosnia and Herzegovina)","ror":"https://ror.org/025jqxp42","country_code":"BA","type":"company","lineage":["https://openalex.org/I4210117113"]}],"countries":["BA"],"is_corresponding":false,"raw_author_name":"Almir Badnjevic","raw_affiliation_strings":["Medical Device Verification Laboratory, Verlab Ltd Sarajevo, Bosnia and Herzegovina"],"raw_orcid":null,"affiliations":[{"raw_affiliation_string":"Medical Device Verification Laboratory, Verlab Ltd Sarajevo, Bosnia and Herzegovina","institution_ids":["https://openalex.org/I4210117113"]}]},{"author_position":"middle","author":{"id":"https://openalex.org/A5110429324","display_name":"Lejla Gurbeta","orcid":null},"institutions":[{"id":"https://openalex.org/I4210117113","display_name":"Verlab (Bosnia and Herzegovina)","ror":"https://ror.org/025jqxp42","country_code":"BA","type":"company","lineage":["https://openalex.org/I4210117113"]}],"countries":["BA"],"is_corresponding":false,"raw_author_name":"Lejla Gurbeta","raw_affiliation_strings":["Medical Device Verification Laboratory, Verlab Ltd Sarajevo, Bosnia and Herzegovina"],"raw_orcid":null,"affiliations":[{"raw_affiliation_string":"Medical Device Verification Laboratory, Verlab Ltd Sarajevo, Bosnia and Herzegovina","institution_ids":["https://openalex.org/I4210117113"]}]},{"author_position":"middle","author":{"id":"https://openalex.org/A5014553261","display_name":"Du\u0161anka Bo\u0161kovi\u0107","orcid":"https://orcid.org/0000-0002-7535-4693"},"institutions":[{"id":"https://openalex.org/I104817121","display_name":"University of Sarajevo","ror":"https://ror.org/02hhwgd43","country_code":"BA","type":"education","lineage":["https://openalex.org/I104817121"]},{"id":"https://openalex.org/I4210094856","display_name":"Institute of Metrology of Bosnia and Herzegovina","ror":"https://ror.org/00h90tt32","country_code":"BA","type":"facility","lineage":["https://openalex.org/I4210094856"]}],"countries":["BA"],"is_corresponding":false,"raw_author_name":"Dusanka Boskovic","raw_affiliation_strings":["Insititute of Metrology of Bosnia and Herzegovina, Sarajevo, Bosnia, Herzegovina","University of Sarajevo,Faculty of Electrical engineering,Sarajevo,Bosnia and Herzegovina"],"raw_orcid":null,"affiliations":[{"raw_affiliation_string":"Insititute of Metrology of Bosnia and Herzegovina, Sarajevo, Bosnia, Herzegovina","institution_ids":["https://openalex.org/I4210094856"]},{"raw_affiliation_string":"University of Sarajevo,Faculty of Electrical engineering,Sarajevo,Bosnia and Herzegovina","institution_ids":["https://openalex.org/I104817121"]}]},{"author_position":"last","author":{"id":"https://openalex.org/A5083390985","display_name":"Zijad D\u017eemi\u0107","orcid":null},"institutions":[{"id":"https://openalex.org/I4210094856","display_name":"Institute of Metrology of Bosnia and Herzegovina","ror":"https://ror.org/00h90tt32","country_code":"BA","type":"facility","lineage":["https://openalex.org/I4210094856"]}],"countries":["BA"],"is_corresponding":false,"raw_author_name":"Zijad Dzemic","raw_affiliation_strings":["Insititute of Metrology of Bosnia and Herzegovina Sarajevo, Bosnia and Herzegovina"],"raw_orcid":null,"affiliations":[{"raw_affiliation_string":"Insititute of Metrology of Bosnia and Herzegovina Sarajevo, Bosnia and Herzegovina","institution_ids":["https://openalex.org/I4210094856"]}]}],"institutions":[],"countries_distinct_count":1,"institutions_distinct_count":4,"corresponding_author_ids":[],"corresponding_institution_ids":[],"apc_list":null,"apc_paid":null,"fwci":21.8466,"has_fulltext":false,"cited_by_count":46,"citation_normalized_percentile":{"value":0.99140753,"is_in_top_1_percent":true,"is_in_top_10_percent":true},"cited_by_percentile_year":{"min":94,"max":99},"biblio":{"volume":null,"issue":null,"first_page":"365","last_page":"367"},"is_retracted":false,"is_paratext":false,"is_xpac":false,"primary_topic":{"id":"https://openalex.org/T13690","display_name":"Quality and Safety in Healthcare","score":0.9954000115394592,"subfield":{"id":"https://openalex.org/subfields/3607","display_name":"Medical Laboratory Technology"},"field":{"id":"https://openalex.org/fields/36","display_name":"Health Professions"},"domain":{"id":"https://openalex.org/domains/4","display_name":"Health Sciences"}},"topics":[{"id":"https://openalex.org/T13690","display_name":"Quality and Safety in Healthcare","score":0.9954000115394592,"subfield":{"id":"https://openalex.org/subfields/3607","display_name":"Medical Laboratory Technology"},"field":{"id":"https://openalex.org/fields/36","display_name":"Health Professions"},"domain":{"id":"https://openalex.org/domains/4","display_name":"Health Sciences"}},{"id":"https://openalex.org/T13248","display_name":"Healthcare Technology and Patient Monitoring","score":0.9599999785423279,"subfield":{"id":"https://openalex.org/subfields/2746","display_name":"Surgery"},"field":{"id":"https://openalex.org/fields/27","display_name":"Medicine"},"domain":{"id":"https://openalex.org/domains/4","display_name":"Health Sciences"}}],"keywords":[{"id":"https://openalex.org/keywords/metrology","display_name":"Metrology","score":0.78196120262146},{"id":"https://openalex.org/keywords/medical-device","display_name":"Medical device","score":0.6193907856941223},{"id":"https://openalex.org/keywords/medical-equipment","display_name":"Medical equipment","score":0.44015151262283325},{"id":"https://openalex.org/keywords/computer-science","display_name":"Computer science","score":0.4332396984100342},{"id":"https://openalex.org/keywords/medical-physics","display_name":"Medical physics","score":0.40576881170272827},{"id":"https://openalex.org/keywords/medicine","display_name":"Medicine","score":0.37317508459091187},{"id":"https://openalex.org/keywords/medical-emergency","display_name":"Medical emergency","score":0.3558555543422699},{"id":"https://openalex.org/keywords/biomedical-engineering","display_name":"Biomedical engineering","score":0.19058454036712646},{"id":"https://openalex.org/keywords/nursing","display_name":"Nursing","score":0.10206994414329529}],"concepts":[{"id":"https://openalex.org/C195766429","wikidata":"https://www.wikidata.org/wiki/Q394","display_name":"Metrology","level":2,"score":0.78196120262146},{"id":"https://openalex.org/C3020535179","wikidata":"https://www.wikidata.org/wiki/Q6554101","display_name":"Medical device","level":2,"score":0.6193907856941223},{"id":"https://openalex.org/C513323569","wikidata":"https://www.wikidata.org/wiki/Q6554101","display_name":"Medical equipment","level":2,"score":0.44015151262283325},{"id":"https://openalex.org/C41008148","wikidata":"https://www.wikidata.org/wiki/Q21198","display_name":"Computer science","level":0,"score":0.4332396984100342},{"id":"https://openalex.org/C19527891","wikidata":"https://www.wikidata.org/wiki/Q1120908","display_name":"Medical physics","level":1,"score":0.40576881170272827},{"id":"https://openalex.org/C71924100","wikidata":"https://www.wikidata.org/wiki/Q11190","display_name":"Medicine","level":0,"score":0.37317508459091187},{"id":"https://openalex.org/C545542383","wikidata":"https://www.wikidata.org/wiki/Q2751242","display_name":"Medical emergency","level":1,"score":0.3558555543422699},{"id":"https://openalex.org/C136229726","wikidata":"https://www.wikidata.org/wiki/Q327092","display_name":"Biomedical engineering","level":1,"score":0.19058454036712646},{"id":"https://openalex.org/C159110408","wikidata":"https://www.wikidata.org/wiki/Q121176","display_name":"Nursing","level":1,"score":0.10206994414329529},{"id":"https://openalex.org/C33923547","wikidata":"https://www.wikidata.org/wiki/Q395","display_name":"Mathematics","level":0,"score":0.0},{"id":"https://openalex.org/C105795698","wikidata":"https://www.wikidata.org/wiki/Q12483","display_name":"Statistics","level":1,"score":0.0}],"mesh":[],"locations_count":1,"locations":[{"id":"doi:10.1109/meco.2015.7181945","is_oa":false,"landing_page_url":"https://doi.org/10.1109/meco.2015.7181945","pdf_url":null,"source":null,"license":null,"license_id":null,"version":"publishedVersion","is_accepted":true,"is_published":true,"raw_source_name":"2015 4th Mediterranean Conference on Embedded Computing (MECO)","raw_type":"proceedings-article"}],"best_oa_location":null,"sustainable_development_goals":[{"display_name":"Partnerships for the goals","score":0.4099999964237213,"id":"https://metadata.un.org/sdg/17"}],"awards":[],"funders":[],"has_content":{"grobid_xml":false,"pdf":false},"content_urls":null,"referenced_works_count":2,"referenced_works":["https://openalex.org/W325784746","https://openalex.org/W2539238575"],"related_works":["https://openalex.org/W1998546186","https://openalex.org/W2061967405","https://openalex.org/W2174860717","https://openalex.org/W2392646414","https://openalex.org/W2110528520","https://openalex.org/W2590542424","https://openalex.org/W2021243286","https://openalex.org/W2350771407","https://openalex.org/W2392869446","https://openalex.org/W2120907055"],"abstract_inverted_index":{"In":[0,24],"addition":[1],"to":[2,45,61],"knowledge":[3],"and":[4,11,19,50,60,66,69,87,99,154,172,217,224,250,270,295,300],"experience":[5],"of":[6,21,28,34,53,55,77,83,85,94,105,117,123,126,128,138,150,182,188,245,262,274,282,290,304],"medical":[7,22,30,35,56,106,139,192,233,246,263,283,291],"doctors,":[8],"correct":[9],"diagnosis":[10,68,294],"appropriate":[12],"patient":[13,70,209,296],"treatment":[14],"largely":[15],"depend":[16],"on":[17],"accuracy":[18],"functionality":[20,33],"devices.":[23,107],"a":[25,133,186,239,275],"large":[26],"number":[27],"serious":[29],"situations":[31],"proper":[32],"devices":[36,57,118,140,193,234,247,264,292],"is":[37,43],"crucial":[38],"for":[39,103,114,135,230,242,280],"patients.":[40],"Therefore":[41],"it":[42,109,251],"necessary":[44],"carry":[46],"out":[47],"as":[48,58],"strict":[49],"independent":[51],"testing":[52],"functionalities":[54],"possible":[59],"obtain":[62],"the":[63,75,81,92,124,136,142,180,191,199,231,243,255,260,266,272,288,302,305],"most":[64],"accurate":[65],"reliable":[67],"treatment.":[71],"This":[72],"paper":[73],"presents":[74],"results":[76],"study":[78,157],"conducted":[79],"by":[80],"Institute":[82,125],"Metrology":[84,127],"Bosnia":[86],"Herzegovina":[88],"(IMBIH)":[89],"that":[90,119,194,287,301],"highlight":[91],"necessity":[93],"introducing":[95],"metrology":[96,144,201,268],"into":[97,141,198,265],"medicine":[98],"defining":[100],"standard":[101,227],"regulations":[102,229],"inspections":[104],"As":[108,185],"has":[110],"been":[111,196],"previously":[112],"done":[113],"other":[115],"kinds":[116],"are":[120,235],"under":[121,254],"jurisdiction":[122],"BH,":[129],"this":[130,189],"research":[131],"provides":[132],"foundation":[134],"introduction":[137,261],"legal":[143,200,267],"system":[145,202,269,308],"with":[146,271],"precisely":[147],"defined":[148],"units":[149],"measurement,":[151],"their":[152],"ranges":[153],"errors.":[155],"The":[156],"was":[158,248],"based":[159],"upon":[160],"data":[161],"collected":[162],"through":[163],"three":[164],"clinical":[165],"centers,":[166],"25":[167],"hospitals,":[168],"63":[169],"health":[170,175,306],"centers":[171],"320":[173],"private":[174],"institutions":[176],"in":[177,203,293,309],"BH":[178,204,310],"over":[179],"course":[181],"one":[183],"year.":[184],"result":[187],"study,":[190],"have":[195],"introduced":[197],"include":[205],"ECG":[206],"devices,":[207,284],"defibrillators,":[208],"monitors,":[210],"respirators,":[211],"anesthesia":[212],"machines,":[213,215],"dialysis":[214],"pediatric":[216],"neonatal":[218],"incubators,":[219],"therapeutic":[220],"ultrasounds,":[221],"infusion":[222],"pumps":[223],"perfusors.":[225],"Furthermore,":[226],"inspection":[228,244,281],"aforementioned":[232],"also":[236],"defined.":[237],"Additionally,":[238],"national":[240,278],"laboratory":[241,279],"established":[249],"currently":[252],"operates":[253],"ISO":[256],"17020":[257],"standard.":[258],"With":[259],"establishment":[273],"fully":[276],"operational":[277],"we":[285],"expect":[286],"reliability":[289],"care":[297,307],"will":[298,311],"increase":[299],"costs":[303],"be":[312],"reduced.":[313]},"counts_by_year":[{"year":2026,"cited_by_count":1},{"year":2025,"cited_by_count":4},{"year":2024,"cited_by_count":7},{"year":2023,"cited_by_count":4},{"year":2021,"cited_by_count":4},{"year":2020,"cited_by_count":4},{"year":2019,"cited_by_count":10},{"year":2018,"cited_by_count":2},{"year":2017,"cited_by_count":8},{"year":2016,"cited_by_count":2}],"updated_date":"2026-06-11T09:08:48.828518","created_date":"2025-10-10T00:00:00"}
