{"id":"https://openalex.org/W1965706740","doi":"https://doi.org/10.1109/mdat.2013.2294466","title":"Data Center Energy Efficiency:Improving Energy Efficiency in Data Centers Beyond Technology Scaling","display_name":"Data Center Energy Efficiency:Improving Energy Efficiency in Data Centers Beyond Technology Scaling","publication_year":2014,"publication_date":"2014-01-31","ids":{"openalex":"https://openalex.org/W1965706740","doi":"https://doi.org/10.1109/mdat.2013.2294466","mag":"1965706740"},"language":"en","primary_location":{"id":"doi:10.1109/mdat.2013.2294466","is_oa":false,"landing_page_url":"https://doi.org/10.1109/mdat.2013.2294466","pdf_url":null,"source":{"id":"https://openalex.org/S4210176427","display_name":"IEEE Design and Test","issn_l":"2168-2356","issn":["2168-2356","2168-2364"],"is_oa":false,"is_in_doaj":false,"is_core":true,"host_organization":"https://openalex.org/P4310319808","host_organization_name":"Institute of Electrical and Electronics Engineers","host_organization_lineage":["https://openalex.org/P4310319808"],"host_organization_lineage_names":["Institute of Electrical and Electronics Engineers"],"type":"journal"},"license":null,"license_id":null,"version":"publishedVersion","is_accepted":true,"is_published":true,"raw_source_name":"IEEE Design &amp; Test","raw_type":"journal-article"},"type":"article","indexed_in":["crossref"],"open_access":{"is_oa":false,"oa_status":"closed","oa_url":null,"any_repository_has_fulltext":false},"authorships":[{"author_position":"first","author":{"id":"https://openalex.org/A5083979678","display_name":"Frederic T. Chong","orcid":"https://orcid.org/0000-0001-9282-4645"},"institutions":[{"id":"https://openalex.org/I154570441","display_name":"University of California, Santa Barbara","ror":"https://ror.org/02t274463","country_code":"US","type":"education","lineage":["https://openalex.org/I154570441"]}],"countries":["US"],"is_corresponding":false,"raw_author_name":"Frederic T. Chong","raw_affiliation_strings":["University of California at Santa Barbara","University of California, at Santa Barbara"],"raw_orcid":null,"affiliations":[{"raw_affiliation_string":"University of California at Santa Barbara","institution_ids":["https://openalex.org/I154570441"]},{"raw_affiliation_string":"University of California, at Santa Barbara","institution_ids":["https://openalex.org/I154570441"]}]},{"author_position":"middle","author":{"id":"https://openalex.org/A5024408237","display_name":"Martijn J. R. Heck","orcid":"https://orcid.org/0000-0003-4201-4614"},"institutions":[{"id":"https://openalex.org/I154570441","display_name":"University of California, Santa Barbara","ror":"https://ror.org/02t274463","country_code":"US","type":"education","lineage":["https://openalex.org/I154570441"]},{"id":"https://openalex.org/I204337017","display_name":"Aarhus University","ror":"https://ror.org/01aj84f44","country_code":"DK","type":"education","lineage":["https://openalex.org/I204337017"]}],"countries":["DK","US"],"is_corresponding":false,"raw_author_name":"Martijn J. R. Heck","raw_affiliation_strings":["University of California at Santa Barbara","Aarhus University"],"raw_orcid":null,"affiliations":[{"raw_affiliation_string":"University of California at Santa Barbara","institution_ids":["https://openalex.org/I154570441"]},{"raw_affiliation_string":"Aarhus University","institution_ids":["https://openalex.org/I204337017"]}]},{"author_position":"middle","author":{"id":"https://openalex.org/A5011491987","display_name":"Parthasarathy Ranganathan","orcid":"https://orcid.org/0000-0002-9751-5902"},"institutions":[{"id":"https://openalex.org/I1291425158","display_name":"Google (United States)","ror":"https://ror.org/00njsd438","country_code":"US","type":"company","lineage":["https://openalex.org/I1291425158","https://openalex.org/I4210128969"]},{"id":"https://openalex.org/I204337017","display_name":"Aarhus University","ror":"https://ror.org/01aj84f44","country_code":"DK","type":"education","lineage":["https://openalex.org/I204337017"]}],"countries":["DK","US"],"is_corresponding":false,"raw_author_name":"Parthasarathy Ranganathan","raw_affiliation_strings":["Aarhus University","Google\u2020#TAB#"],"raw_orcid":null,"affiliations":[{"raw_affiliation_string":"Aarhus University","institution_ids":["https://openalex.org/I204337017"]},{"raw_affiliation_string":"Google\u2020#TAB#","institution_ids":["https://openalex.org/I1291425158"]}]},{"author_position":"middle","author":{"id":"https://openalex.org/A5052156704","display_name":"A.A.M. Saleh","orcid":"https://orcid.org/0000-0001-8245-1136"},"institutions":[{"id":"https://openalex.org/I1291425158","display_name":"Google (United States)","ror":"https://ror.org/00njsd438","country_code":"US","type":"company","lineage":["https://openalex.org/I1291425158","https://openalex.org/I4210128969"]},{"id":"https://openalex.org/I154570441","display_name":"University of California, Santa Barbara","ror":"https://ror.org/02t274463","country_code":"US","type":"education","lineage":["https://openalex.org/I154570441"]}],"countries":["US"],"is_corresponding":false,"raw_author_name":"Adel A. M. Saleh","raw_affiliation_strings":["Google","University of California, at Santa Barbara"],"raw_orcid":null,"affiliations":[{"raw_affiliation_string":"Google","institution_ids":["https://openalex.org/I1291425158"]},{"raw_affiliation_string":"University of California, at Santa Barbara","institution_ids":["https://openalex.org/I154570441"]}]},{"author_position":"last","author":{"id":"https://openalex.org/A5045933110","display_name":"Hassan M. G. Wassel","orcid":"https://orcid.org/0009-0004-4090-5987"},"institutions":[{"id":"https://openalex.org/I1291425158","display_name":"Google (United States)","ror":"https://ror.org/00njsd438","country_code":"US","type":"company","lineage":["https://openalex.org/I1291425158","https://openalex.org/I4210128969"]}],"countries":["US"],"is_corresponding":false,"raw_author_name":"Hassan M. G. Wassel","raw_affiliation_strings":["Google","Google\u2020#TAB#"],"raw_orcid":null,"affiliations":[{"raw_affiliation_string":"Google","institution_ids":["https://openalex.org/I1291425158"]},{"raw_affiliation_string":"Google\u2020#TAB#","institution_ids":["https://openalex.org/I1291425158"]}]}],"institutions":[],"countries_distinct_count":2,"institutions_distinct_count":3,"corresponding_author_ids":[],"corresponding_institution_ids":[],"apc_list":null,"apc_paid":null,"fwci":4.8514,"has_fulltext":false,"cited_by_count":35,"citation_normalized_percentile":{"value":0.94808542,"is_in_top_1_percent":false,"is_in_top_10_percent":true},"cited_by_percentile_year":{"min":90,"max":99},"biblio":{"volume":"31","issue":"1","first_page":"93","last_page":"104"},"is_retracted":false,"is_paratext":false,"is_xpac":false,"primary_topic":{"id":"https://openalex.org/T10101","display_name":"Cloud Computing and Resource Management","score":0.9998999834060669,"subfield":{"id":"https://openalex.org/subfields/1710","display_name":"Information Systems"},"field":{"id":"https://openalex.org/fields/17","display_name":"Computer Science"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}},"topics":[{"id":"https://openalex.org/T10101","display_name":"Cloud Computing and Resource Management","score":0.9998999834060669,"subfield":{"id":"https://openalex.org/subfields/1710","display_name":"Information Systems"},"field":{"id":"https://openalex.org/fields/17","display_name":"Computer Science"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}},{"id":"https://openalex.org/T11181","display_name":"Advanced Data Storage Technologies","score":0.9990000128746033,"subfield":{"id":"https://openalex.org/subfields/1705","display_name":"Computer Networks and Communications"},"field":{"id":"https://openalex.org/fields/17","display_name":"Computer Science"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}},{"id":"https://openalex.org/T10273","display_name":"IoT and Edge/Fog Computing","score":0.9965000152587891,"subfield":{"id":"https://openalex.org/subfields/1705","display_name":"Computer Networks and Communications"},"field":{"id":"https://openalex.org/fields/17","display_name":"Computer Science"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}}],"keywords":[{"id":"https://openalex.org/keywords/data-center","display_name":"Data center","score":0.7974199056625366},{"id":"https://openalex.org/keywords/computer-science","display_name":"Computer science","score":0.7242909669876099},{"id":"https://openalex.org/keywords/provisioning","display_name":"Provisioning","score":0.693657398223877},{"id":"https://openalex.org/keywords/efficient-energy-use","display_name":"Efficient energy use","score":0.618472158908844},{"id":"https://openalex.org/keywords/workload","display_name":"Workload","score":0.5793155431747437},{"id":"https://openalex.org/keywords/software","display_name":"Software","score":0.5752522945404053},{"id":"https://openalex.org/keywords/energy-consumption","display_name":"Energy consumption","score":0.5341982245445251},{"id":"https://openalex.org/keywords/key","display_name":"Key (lock)","score":0.5209671258926392},{"id":"https://openalex.org/keywords/component","display_name":"Component (thermodynamics)","score":0.4105141758918762},{"id":"https://openalex.org/keywords/distributed-computing","display_name":"Distributed computing","score":0.38843971490859985},{"id":"https://openalex.org/keywords/embedded-system","display_name":"Embedded system","score":0.36423105001449585},{"id":"https://openalex.org/keywords/computer-architecture","display_name":"Computer architecture","score":0.3301914930343628},{"id":"https://openalex.org/keywords/database","display_name":"Database","score":0.32410064339637756},{"id":"https://openalex.org/keywords/operating-system","display_name":"Operating system","score":0.26328665018081665},{"id":"https://openalex.org/keywords/engineering","display_name":"Engineering","score":0.14796891808509827},{"id":"https://openalex.org/keywords/electrical-engineering","display_name":"Electrical engineering","score":0.09596720337867737}],"concepts":[{"id":"https://openalex.org/C153740404","wikidata":"https://www.wikidata.org/wiki/Q671224","display_name":"Data center","level":2,"score":0.7974199056625366},{"id":"https://openalex.org/C41008148","wikidata":"https://www.wikidata.org/wiki/Q21198","display_name":"Computer science","level":0,"score":0.7242909669876099},{"id":"https://openalex.org/C172191483","wikidata":"https://www.wikidata.org/wiki/Q1071806","display_name":"Provisioning","level":2,"score":0.693657398223877},{"id":"https://openalex.org/C2742236","wikidata":"https://www.wikidata.org/wiki/Q924713","display_name":"Efficient energy use","level":2,"score":0.618472158908844},{"id":"https://openalex.org/C2778476105","wikidata":"https://www.wikidata.org/wiki/Q628539","display_name":"Workload","level":2,"score":0.5793155431747437},{"id":"https://openalex.org/C2777904410","wikidata":"https://www.wikidata.org/wiki/Q7397","display_name":"Software","level":2,"score":0.5752522945404053},{"id":"https://openalex.org/C2780165032","wikidata":"https://www.wikidata.org/wiki/Q16869822","display_name":"Energy consumption","level":2,"score":0.5341982245445251},{"id":"https://openalex.org/C26517878","wikidata":"https://www.wikidata.org/wiki/Q228039","display_name":"Key (lock)","level":2,"score":0.5209671258926392},{"id":"https://openalex.org/C168167062","wikidata":"https://www.wikidata.org/wiki/Q1117970","display_name":"Component (thermodynamics)","level":2,"score":0.4105141758918762},{"id":"https://openalex.org/C120314980","wikidata":"https://www.wikidata.org/wiki/Q180634","display_name":"Distributed computing","level":1,"score":0.38843971490859985},{"id":"https://openalex.org/C149635348","wikidata":"https://www.wikidata.org/wiki/Q193040","display_name":"Embedded system","level":1,"score":0.36423105001449585},{"id":"https://openalex.org/C118524514","wikidata":"https://www.wikidata.org/wiki/Q173212","display_name":"Computer architecture","level":1,"score":0.3301914930343628},{"id":"https://openalex.org/C77088390","wikidata":"https://www.wikidata.org/wiki/Q8513","display_name":"Database","level":1,"score":0.32410064339637756},{"id":"https://openalex.org/C111919701","wikidata":"https://www.wikidata.org/wiki/Q9135","display_name":"Operating system","level":1,"score":0.26328665018081665},{"id":"https://openalex.org/C127413603","wikidata":"https://www.wikidata.org/wiki/Q11023","display_name":"Engineering","level":0,"score":0.14796891808509827},{"id":"https://openalex.org/C119599485","wikidata":"https://www.wikidata.org/wiki/Q43035","display_name":"Electrical engineering","level":1,"score":0.09596720337867737},{"id":"https://openalex.org/C97355855","wikidata":"https://www.wikidata.org/wiki/Q11473","display_name":"Thermodynamics","level":1,"score":0.0},{"id":"https://openalex.org/C121332964","wikidata":"https://www.wikidata.org/wiki/Q413","display_name":"Physics","level":0,"score":0.0}],"mesh":[],"locations_count":2,"locations":[{"id":"doi:10.1109/mdat.2013.2294466","is_oa":false,"landing_page_url":"https://doi.org/10.1109/mdat.2013.2294466","pdf_url":null,"source":{"id":"https://openalex.org/S4210176427","display_name":"IEEE Design and Test","issn_l":"2168-2356","issn":["2168-2356","2168-2364"],"is_oa":false,"is_in_doaj":false,"is_core":true,"host_organization":"https://openalex.org/P4310319808","host_organization_name":"Institute of Electrical and Electronics Engineers","host_organization_lineage":["https://openalex.org/P4310319808"],"host_organization_lineage_names":["Institute of Electrical and Electronics Engineers"],"type":"journal"},"license":null,"license_id":null,"version":"publishedVersion","is_accepted":true,"is_published":true,"raw_source_name":"IEEE Design &amp; Test","raw_type":"journal-article"},{"id":"pmh:oai:pure.atira.dk:publications/6c78d93b-7030-4433-8230-7ba5c36edb42","is_oa":false,"landing_page_url":"https://pure.au.dk/portal/en/publications/6c78d93b-7030-4433-8230-7ba5c36edb42","pdf_url":null,"source":null,"license":null,"license_id":null,"version":"submittedVersion","is_accepted":false,"is_published":false,"raw_source_name":"Chong, F T, Heck, M, Ranganathan, P, Saleh, A M & Wassel, H M G 2014, 'Data center energy efficiency: Improving energy efficiency in data centers beyond technology scaling', IEEE Design and Test of Computers, vol. 31, no. 1, pp. 93-104. https://doi.org/10.1109/MDAT.2013.2294466","raw_type":"info:eu-repo/semantics/article"}],"best_oa_location":null,"sustainable_development_goals":[{"score":0.8899999856948853,"id":"https://metadata.un.org/sdg/7","display_name":"Affordable and clean energy"}],"awards":[],"funders":[{"id":"https://openalex.org/F4320306399","display_name":"Kavli Foundation","ror":"https://ror.org/00kztt736"},{"id":"https://openalex.org/F4320332500","display_name":"University of California, Santa Barbara","ror":"https://ror.org/02t274463"}],"has_content":{"pdf":false,"grobid_xml":false},"content_urls":null,"referenced_works_count":8,"referenced_works":["https://openalex.org/W1986141617","https://openalex.org/W2065088268","https://openalex.org/W2119565742","https://openalex.org/W2119638333","https://openalex.org/W2141262802","https://openalex.org/W2161047342","https://openalex.org/W4239670432","https://openalex.org/W4312920248"],"related_works":["https://openalex.org/W2000785801","https://openalex.org/W986318368","https://openalex.org/W2384410913","https://openalex.org/W2352878646","https://openalex.org/W2004734601","https://openalex.org/W2287264064","https://openalex.org/W2165967062","https://openalex.org/W4389065284","https://openalex.org/W2903994135","https://openalex.org/W2185314374"],"abstract_inverted_index":{"The":[0],"paper":[1],"identifies":[2],"four":[3],"key":[4],"themes":[5],"that":[6],"should":[7],"be":[8],"addressed":[9],"to":[10,25,32,53,57,80],"improve":[11],"energy":[12,48],"efficiency":[13],"in":[14],"data":[15,36],"centers:":[16],"These":[17],"include":[18],"understanding":[19],"the":[20,47,63,82],"newly":[21],"emerging":[22],"workload":[23],"space":[24],"ensure":[26],"proper":[27],"matching":[28],"of":[29,50,66,84],"architecture":[30],"design":[31],"application":[33],"requirements;":[34],"provisioning":[35],"center":[37],"resources":[38],"for":[39,75],"predicted":[40],"future":[41],"workloads":[42],"and":[43,45,69,72,77,87],"applications,":[44],"improving":[46,59],"proportionality":[49],"individual":[51],"machines":[52],"correlate":[54],"power":[55],"consumption":[56],"load;":[58],"vertical":[60],"integration":[61,83],"within":[62],"software":[64,78],"stacks":[65],"communication,":[67],"storage,":[68],"runtime":[70],"systems;":[71],"establishing":[73],"standards":[74],"hardware":[76],"communications":[79],"allow":[81],"new":[85],"technologies":[86],"component":[88],"designs.":[89]},"counts_by_year":[{"year":2025,"cited_by_count":3},{"year":2024,"cited_by_count":2},{"year":2023,"cited_by_count":3},{"year":2021,"cited_by_count":3},{"year":2020,"cited_by_count":4},{"year":2019,"cited_by_count":6},{"year":2018,"cited_by_count":8},{"year":2017,"cited_by_count":2},{"year":2016,"cited_by_count":1},{"year":2015,"cited_by_count":3}],"updated_date":"2025-11-06T03:46:38.306776","created_date":"2025-10-10T00:00:00"}
