{"id":"https://openalex.org/W2943786378","doi":"https://doi.org/10.1109/mcom.2019.1800473","title":"Optical- and Electrical-Domain Compensation Techniques for Next-Generation Passive Optical Networks","display_name":"Optical- and Electrical-Domain Compensation Techniques for Next-Generation Passive Optical Networks","publication_year":2019,"publication_date":"2019-04-01","ids":{"openalex":"https://openalex.org/W2943786378","doi":"https://doi.org/10.1109/mcom.2019.1800473","mag":"2943786378"},"language":"en","primary_location":{"id":"doi:10.1109/mcom.2019.1800473","is_oa":false,"landing_page_url":"https://doi.org/10.1109/mcom.2019.1800473","pdf_url":null,"source":{"id":"https://openalex.org/S158797327","display_name":"IEEE Communications Magazine","issn_l":"0163-6804","issn":["0163-6804","1558-1896"],"is_oa":false,"is_in_doaj":false,"is_core":true,"host_organization":"https://openalex.org/P4310319808","host_organization_name":"Institute of Electrical and Electronics Engineers","host_organization_lineage":["https://openalex.org/P4310319808"],"host_organization_lineage_names":["Institute of Electrical and Electronics Engineers"],"type":"journal"},"license":null,"license_id":null,"version":"publishedVersion","is_accepted":true,"is_published":true,"raw_source_name":"IEEE Communications Magazine","raw_type":"journal-article"},"type":"article","indexed_in":["crossref"],"open_access":{"is_oa":false,"oa_status":"closed","oa_url":null,"any_repository_has_fulltext":false},"authorships":[{"author_position":"first","author":{"id":"https://openalex.org/A5100363355","display_name":"Zhiguo Zhang","orcid":"https://orcid.org/0009-0000-4839-8079"},"institutions":[],"countries":[],"is_corresponding":true,"raw_author_name":"Zhiguo Zhang","raw_affiliation_strings":["State Key Laboratory of IPOC, BUPT"],"affiliations":[{"raw_affiliation_string":"State Key Laboratory of IPOC, BUPT","institution_ids":[]}]},{"author_position":"middle","author":{"id":"https://openalex.org/A5103109985","display_name":"Qi Guo","orcid":"https://orcid.org/0000-0002-7151-5074"},"institutions":[],"countries":[],"is_corresponding":false,"raw_author_name":"Qi Guo","raw_affiliation_strings":["State Key Laboratory of IPOC, BUPT"],"affiliations":[{"raw_affiliation_string":"State Key Laboratory of IPOC, BUPT","institution_ids":[]}]},{"author_position":"middle","author":{"id":"https://openalex.org/A5101541728","display_name":"Cheng Ju","orcid":"https://orcid.org/0000-0002-2282-6917"},"institutions":[],"countries":[],"is_corresponding":false,"raw_author_name":"Cheng Ju","raw_affiliation_strings":["State Key Laboratory of IPOC, BUPT"],"affiliations":[{"raw_affiliation_string":"State Key Laboratory of IPOC, BUPT","institution_ids":[]}]},{"author_position":"middle","author":{"id":"https://openalex.org/A5069760044","display_name":"Shanyong Cai","orcid":"https://orcid.org/0000-0001-8596-4252"},"institutions":[],"countries":[],"is_corresponding":false,"raw_author_name":"Shanyong Cai","raw_affiliation_strings":["State Key Laboratory of IPOC, BUPT"],"affiliations":[{"raw_affiliation_string":"State Key Laboratory of IPOC, BUPT","institution_ids":[]}]},{"author_position":"middle","author":{"id":"https://openalex.org/A5037297143","display_name":"Liqian Wang","orcid":"https://orcid.org/0000-0001-5456-7051"},"institutions":[],"countries":[],"is_corresponding":false,"raw_author_name":"Liqian Wang","raw_affiliation_strings":["State Key Laboratory of IPOC, BUPT"],"affiliations":[{"raw_affiliation_string":"State Key Laboratory of IPOC, BUPT","institution_ids":[]}]},{"author_position":"middle","author":{"id":"https://openalex.org/A5100402952","display_name":"Min Zhang","orcid":"https://orcid.org/0000-0002-8230-300X"},"institutions":[],"countries":[],"is_corresponding":false,"raw_author_name":"Min Zhang","raw_affiliation_strings":["State Key Laboratory of IPOC, BUPT"],"affiliations":[{"raw_affiliation_string":"State Key Laboratory of IPOC, BUPT","institution_ids":[]}]},{"author_position":"last","author":{"id":"https://openalex.org/A5027933789","display_name":"Xue Chen","orcid":"https://orcid.org/0000-0001-5219-8176"},"institutions":[],"countries":[],"is_corresponding":false,"raw_author_name":"Xue Chen","raw_affiliation_strings":["State Key Laboratory of IPOC, BUPT"],"affiliations":[{"raw_affiliation_string":"State Key Laboratory of IPOC, BUPT","institution_ids":[]}]}],"institutions":[],"countries_distinct_count":0,"institutions_distinct_count":7,"corresponding_author_ids":["https://openalex.org/A5100363355"],"corresponding_institution_ids":[],"apc_list":null,"apc_paid":null,"fwci":1.4307,"has_fulltext":false,"cited_by_count":17,"citation_normalized_percentile":{"value":0.82023372,"is_in_top_1_percent":false,"is_in_top_10_percent":false},"cited_by_percentile_year":{"min":89,"max":97},"biblio":{"volume":"57","issue":"4","first_page":"144","last_page":"150"},"is_retracted":false,"is_paratext":false,"is_xpac":false,"primary_topic":{"id":"https://openalex.org/T10232","display_name":"Optical Network Technologies","score":1.0,"subfield":{"id":"https://openalex.org/subfields/2208","display_name":"Electrical and Electronic Engineering"},"field":{"id":"https://openalex.org/fields/22","display_name":"Engineering"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}},"topics":[{"id":"https://openalex.org/T10232","display_name":"Optical Network Technologies","score":1.0,"subfield":{"id":"https://openalex.org/subfields/2208","display_name":"Electrical and Electronic Engineering"},"field":{"id":"https://openalex.org/fields/22","display_name":"Engineering"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}},{"id":"https://openalex.org/T10767","display_name":"Advanced Photonic Communication Systems","score":1.0,"subfield":{"id":"https://openalex.org/subfields/2208","display_name":"Electrical and Electronic Engineering"},"field":{"id":"https://openalex.org/fields/22","display_name":"Engineering"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}},{"id":"https://openalex.org/T10847","display_name":"Advanced Optical Network Technologies","score":0.9962999820709229,"subfield":{"id":"https://openalex.org/subfields/2208","display_name":"Electrical and Electronic Engineering"},"field":{"id":"https://openalex.org/fields/22","display_name":"Engineering"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}}],"keywords":[{"id":"https://openalex.org/keywords/computer-science","display_name":"Computer science","score":0.809968113899231},{"id":"https://openalex.org/keywords/passive-optical-network","display_name":"Passive optical network","score":0.5580416917800903},{"id":"https://openalex.org/keywords/optical-performance-monitoring","display_name":"Optical performance monitoring","score":0.4965842366218567},{"id":"https://openalex.org/keywords/optical-cross-connect","display_name":"Optical cross-connect","score":0.4940808117389679},{"id":"https://openalex.org/keywords/compensation","display_name":"Compensation (psychology)","score":0.48578813672065735},{"id":"https://openalex.org/keywords/telecommunications","display_name":"Telecommunications","score":0.4673612117767334},{"id":"https://openalex.org/keywords/computer-network","display_name":"Computer network","score":0.43475541472435},{"id":"https://openalex.org/keywords/optical-switch","display_name":"Optical switch","score":0.42829716205596924},{"id":"https://openalex.org/keywords/electronic-engineering","display_name":"Electronic engineering","score":0.3938521146774292},{"id":"https://openalex.org/keywords/wavelength-division-multiplexing","display_name":"Wavelength-division multiplexing","score":0.28813502192497253},{"id":"https://openalex.org/keywords/optical-fiber","display_name":"Optical fiber","score":0.26599588990211487},{"id":"https://openalex.org/keywords/optoelectronics","display_name":"Optoelectronics","score":0.19472181797027588}],"concepts":[{"id":"https://openalex.org/C41008148","wikidata":"https://www.wikidata.org/wiki/Q21198","display_name":"Computer science","level":0,"score":0.809968113899231},{"id":"https://openalex.org/C204827203","wikidata":"https://www.wikidata.org/wiki/Q1027795","display_name":"Passive optical network","level":4,"score":0.5580416917800903},{"id":"https://openalex.org/C26840048","wikidata":"https://www.wikidata.org/wiki/Q7098880","display_name":"Optical performance monitoring","level":4,"score":0.4965842366218567},{"id":"https://openalex.org/C196129803","wikidata":"https://www.wikidata.org/wiki/Q241448","display_name":"Optical cross-connect","level":3,"score":0.4940808117389679},{"id":"https://openalex.org/C2780023022","wikidata":"https://www.wikidata.org/wiki/Q1338171","display_name":"Compensation (psychology)","level":2,"score":0.48578813672065735},{"id":"https://openalex.org/C76155785","wikidata":"https://www.wikidata.org/wiki/Q418","display_name":"Telecommunications","level":1,"score":0.4673612117767334},{"id":"https://openalex.org/C31258907","wikidata":"https://www.wikidata.org/wiki/Q1301371","display_name":"Computer network","level":1,"score":0.43475541472435},{"id":"https://openalex.org/C101336846","wikidata":"https://www.wikidata.org/wiki/Q17105111","display_name":"Optical switch","level":2,"score":0.42829716205596924},{"id":"https://openalex.org/C24326235","wikidata":"https://www.wikidata.org/wiki/Q126095","display_name":"Electronic engineering","level":1,"score":0.3938521146774292},{"id":"https://openalex.org/C160724564","wikidata":"https://www.wikidata.org/wiki/Q1620670","display_name":"Wavelength-division multiplexing","level":3,"score":0.28813502192497253},{"id":"https://openalex.org/C194232370","wikidata":"https://www.wikidata.org/wiki/Q162","display_name":"Optical fiber","level":2,"score":0.26599588990211487},{"id":"https://openalex.org/C49040817","wikidata":"https://www.wikidata.org/wiki/Q193091","display_name":"Optoelectronics","level":1,"score":0.19472181797027588},{"id":"https://openalex.org/C127413603","wikidata":"https://www.wikidata.org/wiki/Q11023","display_name":"Engineering","level":0,"score":0.0},{"id":"https://openalex.org/C11171543","wikidata":"https://www.wikidata.org/wiki/Q41630","display_name":"Psychoanalysis","level":1,"score":0.0},{"id":"https://openalex.org/C121332964","wikidata":"https://www.wikidata.org/wiki/Q413","display_name":"Physics","level":0,"score":0.0},{"id":"https://openalex.org/C15744967","wikidata":"https://www.wikidata.org/wiki/Q9418","display_name":"Psychology","level":0,"score":0.0},{"id":"https://openalex.org/C6260449","wikidata":"https://www.wikidata.org/wiki/Q41364","display_name":"Wavelength","level":2,"score":0.0}],"mesh":[],"locations_count":1,"locations":[{"id":"doi:10.1109/mcom.2019.1800473","is_oa":false,"landing_page_url":"https://doi.org/10.1109/mcom.2019.1800473","pdf_url":null,"source":{"id":"https://openalex.org/S158797327","display_name":"IEEE Communications Magazine","issn_l":"0163-6804","issn":["0163-6804","1558-1896"],"is_oa":false,"is_in_doaj":false,"is_core":true,"host_organization":"https://openalex.org/P4310319808","host_organization_name":"Institute of Electrical and Electronics Engineers","host_organization_lineage":["https://openalex.org/P4310319808"],"host_organization_lineage_names":["Institute of Electrical and Electronics Engineers"],"type":"journal"},"license":null,"license_id":null,"version":"publishedVersion","is_accepted":true,"is_published":true,"raw_source_name":"IEEE Communications Magazine","raw_type":"journal-article"}],"best_oa_location":null,"sustainable_development_goals":[],"awards":[],"funders":[{"id":"https://openalex.org/F4320321001","display_name":"National Natural Science Foundation of China","ror":"https://ror.org/01h0zpd94"}],"has_content":{"grobid_xml":false,"pdf":false},"content_urls":null,"referenced_works_count":15,"referenced_works":["https://openalex.org/W1109453361","https://openalex.org/W2002143698","https://openalex.org/W2018007034","https://openalex.org/W2116044920","https://openalex.org/W2293570110","https://openalex.org/W2417483723","https://openalex.org/W2548527156","https://openalex.org/W2570265381","https://openalex.org/W2584485759","https://openalex.org/W2592661272","https://openalex.org/W2621221899","https://openalex.org/W2762065697","https://openalex.org/W2772179645","https://openalex.org/W2783323148","https://openalex.org/W2886421174"],"related_works":["https://openalex.org/W2049554003","https://openalex.org/W2125133545","https://openalex.org/W1632860450","https://openalex.org/W2080267596","https://openalex.org/W2195204489","https://openalex.org/W266944638","https://openalex.org/W2110607493","https://openalex.org/W2151612091","https://openalex.org/W2052968483","https://openalex.org/W2144784937"],"abstract_inverted_index":{"High-capacity":[0],"TDM-PONs,":[1],"TWDM":[2],"PONs,":[3],"and":[4,30,50,59,65,76,88,107,111,117,125,131],"WDM":[5],"PONs":[6,15,24],"have":[7],"great":[8],"potential":[9],"to":[10,94],"be":[11],"used":[12],"as":[13],"next-generation":[14,73],"in":[16],"emerging":[17],"broadband":[18],"services":[19],"for":[20,61],"various":[21,129],"applications.":[22],"As":[23],"typically":[25],"use":[26],"direct":[27],"detection":[28],"techniques":[29,93],"low-cost":[31],"components,":[32],"transmission":[33,43],"impairments":[34],"become":[35],"one":[36],"of":[37,78,119,127],"the":[38,72,120,128],"main":[39],"limiting":[40],"factors.":[41],"Various":[42],"impairment":[44],"compensation":[45,80,87,92,133],"techniques,":[46,56],"including":[47],"both":[48],"optical":[49,86],"digital":[51],"signal":[52],"processing":[53],"(DSP)":[54],"based":[55],"are":[57,135],"proposed":[58],"demonstrated":[60],"high-speed":[62],"TDM-,":[63],"TWDM-,":[64],"WDM-PONs.":[66],"In":[67,114],"this":[68],"article,":[69],"we":[70],"describe":[71],"PON":[74],"schemes":[75,134],"principles":[77],"different":[79],"techniques.":[81],"We":[82],"propose":[83],"filter":[84],"type":[85,90],"Volterra":[89],"electrical":[91],"compensate":[95],"nonlinear":[96],"inter-symbol":[97],"interference":[98],"caused":[99],"by":[100],"vestigial":[101],"sideband,":[102],"limited":[103],"modulation":[104],"bandwidth,":[105],"in-phase":[106],"quadrature":[108],"imbalance,":[109],"dispersion,":[110],"square-law":[112],"detection.":[113],"addition,":[115],"analyses":[116],"comparison":[118],"equilibrium":[121],"performances,":[122],"features,":[123],"characteristics,":[124],"applicability":[126],"optical-":[130],"electrical-domain":[132],"presented.":[136]},"counts_by_year":[{"year":2025,"cited_by_count":3},{"year":2024,"cited_by_count":1},{"year":2023,"cited_by_count":1},{"year":2022,"cited_by_count":3},{"year":2021,"cited_by_count":4},{"year":2020,"cited_by_count":2},{"year":2019,"cited_by_count":3}],"updated_date":"2025-11-06T03:46:38.306776","created_date":"2025-10-10T00:00:00"}
