{"id":"https://openalex.org/W7124438762","doi":"https://doi.org/10.1109/mcom.001.2500288","title":"A Real-Time Energy-Efficient Monitoring and Management Framework for Sustainability of F5G-Advanced Networks","display_name":"A Real-Time Energy-Efficient Monitoring and Management Framework for Sustainability of F5G-Advanced Networks","publication_year":2026,"publication_date":"2026-01-16","ids":{"openalex":"https://openalex.org/W7124438762","doi":"https://doi.org/10.1109/mcom.001.2500288"},"language":"en","primary_location":{"id":"doi:10.1109/mcom.001.2500288","is_oa":false,"landing_page_url":"https://doi.org/10.1109/mcom.001.2500288","pdf_url":null,"source":{"id":"https://openalex.org/S158797327","display_name":"IEEE Communications Magazine","issn_l":"0163-6804","issn":["0163-6804","1558-1896"],"is_oa":false,"is_in_doaj":false,"is_core":true,"host_organization":"https://openalex.org/P4310319808","host_organization_name":"Institute of Electrical and Electronics Engineers","host_organization_lineage":["https://openalex.org/P4310319808"],"host_organization_lineage_names":["Institute of Electrical and Electronics Engineers"],"type":"journal"},"license":null,"license_id":null,"version":"publishedVersion","is_accepted":true,"is_published":true,"raw_source_name":"IEEE Communications Magazine","raw_type":"journal-article"},"type":"article","indexed_in":["crossref"],"open_access":{"is_oa":true,"oa_status":"green","oa_url":"https://doi.org/10.1109/MCOM.001.2500288","any_repository_has_fulltext":true},"authorships":[{"author_position":"first","author":{"id":"https://openalex.org/A5123250443","display_name":"Waleed Akbar","orcid":null},"institutions":[{"id":"https://openalex.org/I4210087295","display_name":"Centre Tecnologic de Telecomunicacions de Catalunya","ror":"https://ror.org/001cwea56","country_code":"ES","type":"nonprofit","lineage":["https://openalex.org/I4210087295","https://openalex.org/I4387153040"]}],"countries":["ES"],"is_corresponding":false,"raw_author_name":"Waleed Akbar","raw_affiliation_strings":["Centre Tecnol&#x00F2;gic de Telecomunicacions de Catalunya (CTTC/CERCA),Spain"],"raw_orcid":null,"affiliations":[{"raw_affiliation_string":"Centre Tecnol&#x00F2;gic de Telecomunicacions de Catalunya (CTTC/CERCA),Spain","institution_ids":["https://openalex.org/I4210087295"]}]},{"author_position":"middle","author":{"id":"https://openalex.org/A5076014328","display_name":"F. Javier V\u00edlchez","orcid":"https://orcid.org/0000-0003-1048-2077"},"institutions":[{"id":"https://openalex.org/I4210087295","display_name":"Centre Tecnologic de Telecomunicacions de Catalunya","ror":"https://ror.org/001cwea56","country_code":"ES","type":"nonprofit","lineage":["https://openalex.org/I4210087295","https://openalex.org/I4387153040"]}],"countries":["ES"],"is_corresponding":false,"raw_author_name":"Francisco Javier Vilchez","raw_affiliation_strings":["Centre Tecnol&#x00F2;gic de Telecomunicacions de Catalunya (CTTC/CERCA),Spain"],"raw_orcid":null,"affiliations":[{"raw_affiliation_string":"Centre Tecnol&#x00F2;gic de Telecomunicacions de Catalunya (CTTC/CERCA),Spain","institution_ids":["https://openalex.org/I4210087295"]}]},{"author_position":"middle","author":{"id":"https://openalex.org/A5106662382","display_name":"Pablo Armingol Robles","orcid":"https://orcid.org/0009-0007-5733-4238"},"institutions":[{"id":"https://openalex.org/I4210134591","display_name":"Telefonica Research and Development","ror":"https://ror.org/03qgzzb04","country_code":"ES","type":"company","lineage":["https://openalex.org/I4210097190","https://openalex.org/I4210134591"]}],"countries":["ES"],"is_corresponding":false,"raw_author_name":"Pablo Armingol Robles","raw_affiliation_strings":["Telef&#x00F3;nica Innovaci&#x00F3;n Digital,Spain"],"raw_orcid":null,"affiliations":[{"raw_affiliation_string":"Telef&#x00F3;nica Innovaci&#x00F3;n Digital,Spain","institution_ids":["https://openalex.org/I4210134591"]}]},{"author_position":"middle","author":{"id":"https://openalex.org/A5025992295","display_name":"Lluis Gifre","orcid":null},"institutions":[{"id":"https://openalex.org/I4210087295","display_name":"Centre Tecnologic de Telecomunicacions de Catalunya","ror":"https://ror.org/001cwea56","country_code":"ES","type":"nonprofit","lineage":["https://openalex.org/I4210087295","https://openalex.org/I4387153040"]}],"countries":["ES"],"is_corresponding":false,"raw_author_name":"Lluis Gifre","raw_affiliation_strings":["Centre Tecnol&#x00F2;gic de Telecomunicacions de Catalunya (CTTC/CERCA),Spain"],"raw_orcid":null,"affiliations":[{"raw_affiliation_string":"Centre Tecnol&#x00F2;gic de Telecomunicacions de Catalunya (CTTC/CERCA),Spain","institution_ids":["https://openalex.org/I4210087295"]}]},{"author_position":"middle","author":{"id":"https://openalex.org/A5123214931","display_name":"Ricard Vilalta","orcid":null},"institutions":[{"id":"https://openalex.org/I4210087295","display_name":"Centre Tecnologic de Telecomunicacions de Catalunya","ror":"https://ror.org/001cwea56","country_code":"ES","type":"nonprofit","lineage":["https://openalex.org/I4210087295","https://openalex.org/I4387153040"]}],"countries":["ES"],"is_corresponding":false,"raw_author_name":"Ricard Vilalta","raw_affiliation_strings":["Centre Tecnol&#x00F2;gic de Telecomunicacions de Catalunya (CTTC/CERCA),Spain"],"raw_orcid":null,"affiliations":[{"raw_affiliation_string":"Centre Tecnol&#x00F2;gic de Telecomunicacions de Catalunya (CTTC/CERCA),Spain","institution_ids":["https://openalex.org/I4210087295"]}]},{"author_position":"middle","author":{"id":"https://openalex.org/A5041287258","display_name":"\u00d3scar Gonz\u00e1lez de Dios","orcid":"https://orcid.org/0000-0002-1898-0807"},"institutions":[{"id":"https://openalex.org/I4210134591","display_name":"Telefonica Research and Development","ror":"https://ror.org/03qgzzb04","country_code":"ES","type":"company","lineage":["https://openalex.org/I4210097190","https://openalex.org/I4210134591"]}],"countries":["ES"],"is_corresponding":false,"raw_author_name":"\u00d3scar Gonz\u00e1lez de Dios","raw_affiliation_strings":["Telef&#x00F3;nica Innovaci&#x00F3;n Digital,Spain"],"raw_orcid":null,"affiliations":[{"raw_affiliation_string":"Telef&#x00F3;nica Innovaci&#x00F3;n Digital,Spain","institution_ids":["https://openalex.org/I4210134591"]}]},{"author_position":"middle","author":{"id":"https://openalex.org/A5035631505","display_name":"Juan Pedro Fern\u00e1ndez-Palacios","orcid":"https://orcid.org/0009-0006-1672-6449"},"institutions":[{"id":"https://openalex.org/I4210134591","display_name":"Telefonica Research and Development","ror":"https://ror.org/03qgzzb04","country_code":"ES","type":"company","lineage":["https://openalex.org/I4210097190","https://openalex.org/I4210134591"]}],"countries":["ES"],"is_corresponding":false,"raw_author_name":"Juan Pedro Fern\u00e1ndez-Palacios","raw_affiliation_strings":["Telef&#x00F3;nica Innovaci&#x00F3;n Digital,Spain"],"raw_orcid":null,"affiliations":[{"raw_affiliation_string":"Telef&#x00F3;nica Innovaci&#x00F3;n Digital,Spain","institution_ids":["https://openalex.org/I4210134591"]}]},{"author_position":"middle","author":{"id":"https://openalex.org/A5123231911","display_name":"Yi Lin","orcid":null},"institutions":[{"id":"https://openalex.org/I4210123571","display_name":"Huawei Technologies (France)","ror":"https://ror.org/02rbzf697","country_code":"FR","type":"company","lineage":["https://openalex.org/I2250955327","https://openalex.org/I4210123571"]}],"countries":["FR"],"is_corresponding":false,"raw_author_name":"Yi Lin","raw_affiliation_strings":["Huawei Technologies,France"],"raw_orcid":null,"affiliations":[{"raw_affiliation_string":"Huawei Technologies,France","institution_ids":["https://openalex.org/I4210123571"]}]},{"author_position":"middle","author":{"id":"https://openalex.org/A5123179921","display_name":"Liang Zhang","orcid":null},"institutions":[{"id":"https://openalex.org/I4210123571","display_name":"Huawei Technologies (France)","ror":"https://ror.org/02rbzf697","country_code":"FR","type":"company","lineage":["https://openalex.org/I2250955327","https://openalex.org/I4210123571"]}],"countries":["FR"],"is_corresponding":false,"raw_author_name":"Liang Zhang","raw_affiliation_strings":["Huawei Technologies,France"],"raw_orcid":null,"affiliations":[{"raw_affiliation_string":"Huawei Technologies,France","institution_ids":["https://openalex.org/I4210123571"]}]},{"author_position":"last","author":{"id":null,"display_name":"Ra\u00fcl Mu\u00f1oz","orcid":null},"institutions":[{"id":"https://openalex.org/I4210087295","display_name":"Centre Tecnologic de Telecomunicacions de Catalunya","ror":"https://ror.org/001cwea56","country_code":"ES","type":"nonprofit","lineage":["https://openalex.org/I4210087295","https://openalex.org/I4387153040"]}],"countries":["ES"],"is_corresponding":false,"raw_author_name":"Ra\u00fcl Mu\u00f1oz","raw_affiliation_strings":["Centre Tecnol&#x00F2;gic de Telecomunicacions de Catalunya (CTTC/CERCA),Spain"],"raw_orcid":null,"affiliations":[{"raw_affiliation_string":"Centre Tecnol&#x00F2;gic de Telecomunicacions de Catalunya (CTTC/CERCA),Spain","institution_ids":["https://openalex.org/I4210087295"]}]}],"institutions":[],"countries_distinct_count":2,"institutions_distinct_count":3,"corresponding_author_ids":[],"corresponding_institution_ids":[],"apc_list":null,"apc_paid":null,"fwci":0.0,"has_fulltext":false,"cited_by_count":0,"citation_normalized_percentile":{"value":0.04756367,"is_in_top_1_percent":false,"is_in_top_10_percent":false},"cited_by_percentile_year":null,"biblio":{"volume":"64","issue":"3","first_page":"142","last_page":"147"},"is_retracted":false,"is_paratext":false,"is_xpac":false,"primary_topic":{"id":"https://openalex.org/T10847","display_name":"Advanced Optical Network Technologies","score":0.8555999994277954,"subfield":{"id":"https://openalex.org/subfields/2208","display_name":"Electrical and Electronic Engineering"},"field":{"id":"https://openalex.org/fields/22","display_name":"Engineering"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}},"topics":[{"id":"https://openalex.org/T10847","display_name":"Advanced Optical Network Technologies","score":0.8555999994277954,"subfield":{"id":"https://openalex.org/subfields/2208","display_name":"Electrical and Electronic Engineering"},"field":{"id":"https://openalex.org/fields/22","display_name":"Engineering"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}},{"id":"https://openalex.org/T10714","display_name":"Software-Defined Networks and 5G","score":0.051100000739097595,"subfield":{"id":"https://openalex.org/subfields/1705","display_name":"Computer Networks and Communications"},"field":{"id":"https://openalex.org/fields/17","display_name":"Computer Science"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}},{"id":"https://openalex.org/T10232","display_name":"Optical Network Technologies","score":0.039000000804662704,"subfield":{"id":"https://openalex.org/subfields/2208","display_name":"Electrical and Electronic Engineering"},"field":{"id":"https://openalex.org/fields/22","display_name":"Engineering"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}}],"keywords":[{"id":"https://openalex.org/keywords/testbed","display_name":"Testbed","score":0.6934000253677368},{"id":"https://openalex.org/keywords/agile-software-development","display_name":"Agile software development","score":0.5178999900817871},{"id":"https://openalex.org/keywords/key","display_name":"Key (lock)","score":0.5099999904632568},{"id":"https://openalex.org/keywords/network-architecture","display_name":"Network architecture","score":0.5055999755859375},{"id":"https://openalex.org/keywords/network-management","display_name":"Network management","score":0.48330000042915344},{"id":"https://openalex.org/keywords/sustainability","display_name":"Sustainability","score":0.45579999685287476},{"id":"https://openalex.org/keywords/network-monitoring","display_name":"Network monitoring","score":0.43140000104904175},{"id":"https://openalex.org/keywords/energy-management","display_name":"Energy management","score":0.42410001158714294},{"id":"https://openalex.org/keywords/efficient-energy-use","display_name":"Efficient energy use","score":0.4203999936580658}],"concepts":[{"id":"https://openalex.org/C41008148","wikidata":"https://www.wikidata.org/wiki/Q21198","display_name":"Computer science","level":0,"score":0.7688000202178955},{"id":"https://openalex.org/C31395832","wikidata":"https://www.wikidata.org/wiki/Q1318674","display_name":"Testbed","level":2,"score":0.6934000253677368},{"id":"https://openalex.org/C14185376","wikidata":"https://www.wikidata.org/wiki/Q30232","display_name":"Agile software development","level":2,"score":0.5178999900817871},{"id":"https://openalex.org/C26517878","wikidata":"https://www.wikidata.org/wiki/Q228039","display_name":"Key (lock)","level":2,"score":0.5099999904632568},{"id":"https://openalex.org/C193415008","wikidata":"https://www.wikidata.org/wiki/Q639681","display_name":"Network architecture","level":2,"score":0.5055999755859375},{"id":"https://openalex.org/C129763632","wikidata":"https://www.wikidata.org/wiki/Q1454667","display_name":"Network management","level":2,"score":0.48330000042915344},{"id":"https://openalex.org/C66204764","wikidata":"https://www.wikidata.org/wiki/Q219416","display_name":"Sustainability","level":2,"score":0.45579999685287476},{"id":"https://openalex.org/C31258907","wikidata":"https://www.wikidata.org/wiki/Q1301371","display_name":"Computer network","level":1,"score":0.43810001015663147},{"id":"https://openalex.org/C81877898","wikidata":"https://www.wikidata.org/wiki/Q1965787","display_name":"Network monitoring","level":2,"score":0.43140000104904175},{"id":"https://openalex.org/C7817414","wikidata":"https://www.wikidata.org/wiki/Q1779504","display_name":"Energy management","level":3,"score":0.42410001158714294},{"id":"https://openalex.org/C2742236","wikidata":"https://www.wikidata.org/wiki/Q924713","display_name":"Efficient energy use","level":2,"score":0.4203999936580658},{"id":"https://openalex.org/C32802771","wikidata":"https://www.wikidata.org/wiki/Q2443617","display_name":"Port (circuit theory)","level":2,"score":0.38690000772476196},{"id":"https://openalex.org/C123657996","wikidata":"https://www.wikidata.org/wiki/Q12271","display_name":"Architecture","level":2,"score":0.36239999532699585},{"id":"https://openalex.org/C159631557","wikidata":"https://www.wikidata.org/wiki/Q1546066","display_name":"Networking hardware","level":2,"score":0.34869998693466187},{"id":"https://openalex.org/C104954878","wikidata":"https://www.wikidata.org/wiki/Q1648707","display_name":"Routing protocol","level":3,"score":0.33660000562667847},{"id":"https://openalex.org/C74172769","wikidata":"https://www.wikidata.org/wiki/Q1446839","display_name":"Routing (electronic design automation)","level":2,"score":0.3231000006198883},{"id":"https://openalex.org/C186370098","wikidata":"https://www.wikidata.org/wiki/Q442787","display_name":"Energy (signal processing)","level":2,"score":0.32030001282691956},{"id":"https://openalex.org/C192126672","wikidata":"https://www.wikidata.org/wiki/Q1068715","display_name":"Telecommunications network","level":2,"score":0.29980000853538513},{"id":"https://openalex.org/C138236772","wikidata":"https://www.wikidata.org/wiki/Q25098575","display_name":"Edge device","level":3,"score":0.296099990606308},{"id":"https://openalex.org/C76155785","wikidata":"https://www.wikidata.org/wiki/Q418","display_name":"Telecommunications","level":1,"score":0.2937999963760376},{"id":"https://openalex.org/C98025372","wikidata":"https://www.wikidata.org/wiki/Q477538","display_name":"Systems architecture","level":3,"score":0.2913999855518341},{"id":"https://openalex.org/C201995342","wikidata":"https://www.wikidata.org/wiki/Q682496","display_name":"Systems engineering","level":1,"score":0.2831999957561493},{"id":"https://openalex.org/C162307627","wikidata":"https://www.wikidata.org/wiki/Q204833","display_name":"Enhanced Data Rates for GSM Evolution","level":2,"score":0.28060001134872437},{"id":"https://openalex.org/C120314980","wikidata":"https://www.wikidata.org/wiki/Q180634","display_name":"Distributed computing","level":1,"score":0.2752000093460083},{"id":"https://openalex.org/C16986412","wikidata":"https://www.wikidata.org/wiki/Q918419","display_name":"Network management station","level":3,"score":0.27230000495910645},{"id":"https://openalex.org/C2780165032","wikidata":"https://www.wikidata.org/wiki/Q16869822","display_name":"Energy consumption","level":2,"score":0.26460000872612},{"id":"https://openalex.org/C114563136","wikidata":"https://www.wikidata.org/wiki/Q19725982","display_name":"Network planning and design","level":2,"score":0.25920000672340393},{"id":"https://openalex.org/C5119721","wikidata":"https://www.wikidata.org/wiki/Q220501","display_name":"Quality of service","level":2,"score":0.2581000030040741},{"id":"https://openalex.org/C195094911","wikidata":"https://www.wikidata.org/wiki/Q14167904","display_name":"Process management","level":1,"score":0.25270000100135803},{"id":"https://openalex.org/C129705703","wikidata":"https://www.wikidata.org/wiki/Q786988","display_name":"Operations support system","level":2,"score":0.25099998712539673}],"mesh":[],"locations_count":2,"locations":[{"id":"doi:10.1109/mcom.001.2500288","is_oa":false,"landing_page_url":"https://doi.org/10.1109/mcom.001.2500288","pdf_url":null,"source":{"id":"https://openalex.org/S158797327","display_name":"IEEE Communications Magazine","issn_l":"0163-6804","issn":["0163-6804","1558-1896"],"is_oa":false,"is_in_doaj":false,"is_core":true,"host_organization":"https://openalex.org/P4310319808","host_organization_name":"Institute of Electrical and Electronics Engineers","host_organization_lineage":["https://openalex.org/P4310319808"],"host_organization_lineage_names":["Institute of Electrical and Electronics Engineers"],"type":"journal"},"license":null,"license_id":null,"version":"publishedVersion","is_accepted":true,"is_published":true,"raw_source_name":"IEEE Communications Magazine","raw_type":"journal-article"},{"id":"pmh:oai:zenodo.org:18933750","is_oa":true,"landing_page_url":"https://doi.org/10.1109/MCOM.001.2500288","pdf_url":null,"source":{"id":"https://openalex.org/S4306400562","display_name":"Zenodo (CERN European Organization for Nuclear Research)","issn_l":null,"issn":null,"is_oa":true,"is_in_doaj":false,"is_core":false,"host_organization":"https://openalex.org/I67311998","host_organization_name":"European Organization for Nuclear Research","host_organization_lineage":["https://openalex.org/I67311998"],"host_organization_lineage_names":[],"type":"repository"},"license":"cc-by","license_id":"https://openalex.org/licenses/cc-by","version":"submittedVersion","is_accepted":false,"is_published":false,"raw_source_name":"IEEE COMMUNICATIONS MAGAZINE, (2026-01-01)","raw_type":"info:eu-repo/semantics/article"}],"best_oa_location":{"id":"pmh:oai:zenodo.org:18933750","is_oa":true,"landing_page_url":"https://doi.org/10.1109/MCOM.001.2500288","pdf_url":null,"source":{"id":"https://openalex.org/S4306400562","display_name":"Zenodo (CERN European Organization for Nuclear Research)","issn_l":null,"issn":null,"is_oa":true,"is_in_doaj":false,"is_core":false,"host_organization":"https://openalex.org/I67311998","host_organization_name":"European Organization for Nuclear Research","host_organization_lineage":["https://openalex.org/I67311998"],"host_organization_lineage_names":[],"type":"repository"},"license":"cc-by","license_id":"https://openalex.org/licenses/cc-by","version":"submittedVersion","is_accepted":false,"is_published":false,"raw_source_name":"IEEE COMMUNICATIONS MAGAZINE, (2026-01-01)","raw_type":"info:eu-repo/semantics/article"},"sustainable_development_goals":[{"display_name":"Industry, innovation and infrastructure","id":"https://metadata.un.org/sdg/9","score":0.46334871649742126}],"awards":[],"funders":[],"has_content":{"pdf":false,"grobid_xml":false},"content_urls":null,"referenced_works_count":0,"referenced_works":[],"related_works":[],"abstract_inverted_index":{"The":[0,230,241],"Fifth-Generation":[1],"(5G)":[2],"network":[3,6,79,105,130,145,170],"offers":[4,176],"higher":[5],"capacity":[7],"and":[8,62,89,123,150,185,195,235,248],"edge":[9],"processing,":[10],"while":[11],"the":[12,37,50,71,93,103,111,158,173,200,211,215,233],"transition":[13],"to":[14,48,75,97,120,127,147,169,178,217,221,227,244],"Sixth-Generation":[15],"(6G)":[16],"will":[17],"further":[18],"enhance":[19,49],"these":[20,30,162],"capabilities":[21,53,177],"adding":[22],"support":[23],"for":[24],"more":[25],"advanced":[26],"devices.":[27],"To":[28,132],"address":[29],"emerging":[31],"challenges":[32,95],"in":[33,87,157],"future":[34,253],"telecommunication":[35],"industry,":[36],"ETSI":[38],"Fifth":[39],"Generation":[40],"Fixed":[41],"Network":[42],"(F5G)":[43],"group":[44,73],"is":[45,74,166],"actively":[46],"working":[47],"F5G-A":[51],"architecture":[52,203],"such":[54],"as":[55,188,190],"guaranteed":[56],"reliable":[57],"experience,":[58],"real-time":[59],"resilient":[60],"link":[61],"green":[63],"agile":[64],"optical":[65],"network.":[66,159],"A":[67],"key":[68],"priority":[69],"of":[70,113,182,237],"F5G":[72],"develop":[76],"a":[77,137,167,205],"greener":[78],"solution":[80],"by":[81,193,209],"enhancing":[82],"overall":[83],"energy":[84,100,125,140,152,180,191],"efficiency,":[85],"especially":[86],"routing":[88,247],"computing.":[90],"This":[91],"induces":[92],"practical":[94],"related":[96],"comprehensively":[98],"understanding":[99],"utilization":[101,153],"across":[102],"entire":[104],"infrastructure.":[106],"These":[107],"requirements":[108],"align":[109],"with":[110],"concept":[112],"an":[114],"energy-efficient":[115,246],"monitoring":[116,141,202],"system,":[117],"which":[118],"aims":[119],"track,":[121],"analyze":[122,151],"manage":[124],"usage":[126],"enable":[128],"autonomous":[129],"reconfiguration.":[131],"this":[133,164],"end,":[134],"we":[135],"introduce":[136],"novel":[138],"distributed":[139],"system":[142,165,175],"that":[143],"empowers":[144],"operators":[146],"collect,":[148],"process,":[149],"at":[154],"various":[155],"points":[156],"By":[160],"offering":[161],"insights,":[163],"pathway":[168],"automation.":[171],"Additionally,":[172],"proposed":[174,201,239],"measure":[179],"generation":[181],"both":[183],"local":[184],"external":[186],"sources,":[187],"well":[189],"consumed":[192],"heating":[194],"cooling":[196],"subsystems.":[197],"We":[198],"evaluated":[199],"on":[204],"lab":[206],"testbed":[207],"demonstration":[208],"detecting":[210],"underutilized":[212],"port,":[213],"rerouting":[214],"traffic":[216],"alternative":[218],"path,":[219],"prior":[220],"enabling":[222],"low":[223],"power":[224],"port":[225],"mode":[226],"save":[228],"energy.":[229],"results":[231],"validated":[232],"practicality":[234],"functionality":[236],"our":[238],"approach.":[240],"findings":[242],"contribute":[243],"achieving":[245],"computing,":[249],"thereby":[250],"supporting":[251],"longterm":[252],"sustainability":[254],"goals.":[255]},"counts_by_year":[],"updated_date":"2026-03-13T14:20:09.374765","created_date":"2026-01-17T00:00:00"}
