{"id":"https://openalex.org/W4403094439","doi":"https://doi.org/10.1109/lra.2024.3474552","title":"Binocular Vision-Assisted Magnetic Soft Catheter Robot System for Minimally Invasive in-Situ Bioprinting","display_name":"Binocular Vision-Assisted Magnetic Soft Catheter Robot System for Minimally Invasive in-Situ Bioprinting","publication_year":2024,"publication_date":"2024-10-03","ids":{"openalex":"https://openalex.org/W4403094439","doi":"https://doi.org/10.1109/lra.2024.3474552"},"language":"en","primary_location":{"id":"doi:10.1109/lra.2024.3474552","is_oa":false,"landing_page_url":"https://doi.org/10.1109/lra.2024.3474552","pdf_url":null,"source":{"id":"https://openalex.org/S4210169774","display_name":"IEEE Robotics and Automation Letters","issn_l":"2377-3766","issn":["2377-3766"],"is_oa":false,"is_in_doaj":false,"is_core":true,"host_organization":"https://openalex.org/P4310319808","host_organization_name":"Institute of Electrical and Electronics Engineers","host_organization_lineage":["https://openalex.org/P4310319808"],"host_organization_lineage_names":["Institute of Electrical and Electronics Engineers"],"type":"journal"},"license":null,"license_id":null,"version":"publishedVersion","is_accepted":true,"is_published":true,"raw_source_name":"IEEE Robotics and Automation Letters","raw_type":"journal-article"},"type":"article","indexed_in":["crossref"],"open_access":{"is_oa":false,"oa_status":"closed","oa_url":null,"any_repository_has_fulltext":false},"authorships":[{"author_position":"first","author":{"id":"https://openalex.org/A5107219631","display_name":"Jiarong Hu","orcid":null},"institutions":[{"id":"https://openalex.org/I76130692","display_name":"Zhejiang University","ror":"https://ror.org/00a2xv884","country_code":"CN","type":"education","lineage":["https://openalex.org/I76130692"]}],"countries":["CN"],"is_corresponding":true,"raw_author_name":"Jiarong Hu","raw_affiliation_strings":["State Key Laboratory of Fluid Power and Mechatronic Systems, College of Mechanical Engineering, Zhejiang University, Hangzhou, China"],"affiliations":[{"raw_affiliation_string":"State Key Laboratory of Fluid Power and Mechatronic Systems, College of Mechanical Engineering, Zhejiang University, Hangzhou, China","institution_ids":["https://openalex.org/I76130692"]}]},{"author_position":"middle","author":{"id":"https://openalex.org/A5108995680","display_name":"Liwen Guo","orcid":null},"institutions":[{"id":"https://openalex.org/I76130692","display_name":"Zhejiang University","ror":"https://ror.org/00a2xv884","country_code":"CN","type":"education","lineage":["https://openalex.org/I76130692"]}],"countries":["CN"],"is_corresponding":false,"raw_author_name":"Liwen Guo","raw_affiliation_strings":["State Key Laboratory of Fluid Power and Mechatronic Systems, College of Mechanical Engineering, Zhejiang University, Hangzhou, China"],"affiliations":[{"raw_affiliation_string":"State Key Laboratory of Fluid Power and Mechatronic Systems, College of Mechanical Engineering, Zhejiang University, Hangzhou, China","institution_ids":["https://openalex.org/I76130692"]}]},{"author_position":"middle","author":{"id":"https://openalex.org/A5111351841","display_name":"Wangxie Gu","orcid":null},"institutions":[{"id":"https://openalex.org/I76130692","display_name":"Zhejiang University","ror":"https://ror.org/00a2xv884","country_code":"CN","type":"education","lineage":["https://openalex.org/I76130692"]}],"countries":["CN"],"is_corresponding":false,"raw_author_name":"Wangxie Gu","raw_affiliation_strings":["State Key Laboratory of Fluid Power and Mechatronic Systems, College of Mechanical Engineering, Zhejiang University, Hangzhou, China"],"affiliations":[{"raw_affiliation_string":"State Key Laboratory of Fluid Power and Mechatronic Systems, College of Mechanical Engineering, Zhejiang University, Hangzhou, China","institution_ids":["https://openalex.org/I76130692"]}]},{"author_position":"middle","author":{"id":"https://openalex.org/A5101475204","display_name":"Jiaying Hu","orcid":"https://orcid.org/0000-0003-2718-2783"},"institutions":[{"id":"https://openalex.org/I76130692","display_name":"Zhejiang University","ror":"https://ror.org/00a2xv884","country_code":"CN","type":"education","lineage":["https://openalex.org/I76130692"]}],"countries":["CN"],"is_corresponding":false,"raw_author_name":"Jiaying Hu","raw_affiliation_strings":["State Key Laboratory of Fluid Power and Mechatronic Systems, College of Mechanical Engineering, Zhejiang University, Hangzhou, China"],"affiliations":[{"raw_affiliation_string":"State Key Laboratory of Fluid Power and Mechatronic Systems, College of Mechanical Engineering, Zhejiang University, Hangzhou, China","institution_ids":["https://openalex.org/I76130692"]}]},{"author_position":"middle","author":{"id":"https://openalex.org/A5100340369","display_name":"An Liu","orcid":"https://orcid.org/0000-0002-3943-5234"},"institutions":[{"id":"https://openalex.org/I4210158318","display_name":"Second Affiliated Hospital of Zhejiang University","ror":"https://ror.org/059cjpv64","country_code":"CN","type":"healthcare","lineage":["https://openalex.org/I4210158318"]}],"countries":["CN"],"is_corresponding":false,"raw_author_name":"An Liu","raw_affiliation_strings":["Department of Orthopaedic Surgery, Second Affiliated Hospital, School of Medicine, Zhejiang University, Hangzhou, China"],"affiliations":[{"raw_affiliation_string":"Department of Orthopaedic Surgery, Second Affiliated Hospital, School of Medicine, Zhejiang University, Hangzhou, China","institution_ids":["https://openalex.org/I4210158318"]}]},{"author_position":"middle","author":{"id":"https://openalex.org/A5066372412","display_name":"Yong He","orcid":"https://orcid.org/0000-0002-9408-2937"},"institutions":[{"id":"https://openalex.org/I76130692","display_name":"Zhejiang University","ror":"https://ror.org/00a2xv884","country_code":"CN","type":"education","lineage":["https://openalex.org/I76130692"]}],"countries":["CN"],"is_corresponding":false,"raw_author_name":"Yong He","raw_affiliation_strings":["State Key Laboratory of Fluid Power and Mechatronic Systems, College of Mechanical Engineering, Zhejiang University, Hangzhou, China"],"affiliations":[{"raw_affiliation_string":"State Key Laboratory of Fluid Power and Mechatronic Systems, College of Mechanical Engineering, Zhejiang University, Hangzhou, China","institution_ids":["https://openalex.org/I76130692"]}]},{"author_position":"middle","author":{"id":"https://openalex.org/A5100728019","display_name":"Jianzhong Fu","orcid":"https://orcid.org/0000-0002-5289-9295"},"institutions":[{"id":"https://openalex.org/I76130692","display_name":"Zhejiang University","ror":"https://ror.org/00a2xv884","country_code":"CN","type":"education","lineage":["https://openalex.org/I76130692"]}],"countries":["CN"],"is_corresponding":false,"raw_author_name":"Jianzhong Fu","raw_affiliation_strings":["State Key Laboratory of Fluid Power and Mechatronic Systems, College of Mechanical Engineering, Zhejiang University, Hangzhou, China"],"affiliations":[{"raw_affiliation_string":"State Key Laboratory of Fluid Power and Mechatronic Systems, College of Mechanical Engineering, Zhejiang University, Hangzhou, China","institution_ids":["https://openalex.org/I76130692"]}]},{"author_position":"last","author":{"id":"https://openalex.org/A5048959626","display_name":"Songyu Hu","orcid":"https://orcid.org/0000-0002-0549-309X"},"institutions":[{"id":"https://openalex.org/I76130692","display_name":"Zhejiang University","ror":"https://ror.org/00a2xv884","country_code":"CN","type":"education","lineage":["https://openalex.org/I76130692"]}],"countries":["CN"],"is_corresponding":false,"raw_author_name":"Songyu Hu","raw_affiliation_strings":["State Key Laboratory of Fluid Power and Mechatronic Systems, College of Mechanical Engineering, Zhejiang University, Hangzhou, China"],"affiliations":[{"raw_affiliation_string":"State Key Laboratory of Fluid Power and Mechatronic Systems, College of Mechanical Engineering, Zhejiang University, Hangzhou, China","institution_ids":["https://openalex.org/I76130692"]}]}],"institutions":[],"countries_distinct_count":1,"institutions_distinct_count":8,"corresponding_author_ids":["https://openalex.org/A5107219631"],"corresponding_institution_ids":["https://openalex.org/I76130692"],"apc_list":null,"apc_paid":null,"fwci":2.4266,"has_fulltext":false,"cited_by_count":6,"citation_normalized_percentile":{"value":0.89319065,"is_in_top_1_percent":false,"is_in_top_10_percent":false},"cited_by_percentile_year":{"min":97,"max":99},"biblio":{"volume":"9","issue":"12","first_page":"11130","last_page":"11137"},"is_retracted":false,"is_paratext":false,"is_xpac":false,"primary_topic":{"id":"https://openalex.org/T11438","display_name":"Retinal Imaging and Analysis","score":0.9891999959945679,"subfield":{"id":"https://openalex.org/subfields/2741","display_name":"Radiology, Nuclear Medicine and Imaging"},"field":{"id":"https://openalex.org/fields/27","display_name":"Medicine"},"domain":{"id":"https://openalex.org/domains/4","display_name":"Health Sciences"}},"topics":[{"id":"https://openalex.org/T11438","display_name":"Retinal Imaging and Analysis","score":0.9891999959945679,"subfield":{"id":"https://openalex.org/subfields/2741","display_name":"Radiology, Nuclear Medicine and Imaging"},"field":{"id":"https://openalex.org/fields/27","display_name":"Medicine"},"domain":{"id":"https://openalex.org/domains/4","display_name":"Health Sciences"}},{"id":"https://openalex.org/T11377","display_name":"Retinal and Macular Surgery","score":0.9887999892234802,"subfield":{"id":"https://openalex.org/subfields/2741","display_name":"Radiology, Nuclear Medicine and Imaging"},"field":{"id":"https://openalex.org/fields/27","display_name":"Medicine"},"domain":{"id":"https://openalex.org/domains/4","display_name":"Health Sciences"}},{"id":"https://openalex.org/T10868","display_name":"Soft Robotics and Applications","score":0.9843000173568726,"subfield":{"id":"https://openalex.org/subfields/2204","display_name":"Biomedical Engineering"},"field":{"id":"https://openalex.org/fields/22","display_name":"Engineering"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}}],"keywords":[{"id":"https://openalex.org/keywords/catheter","display_name":"Catheter","score":0.4908776879310608},{"id":"https://openalex.org/keywords/in-situ","display_name":"In situ","score":0.4672088027000427},{"id":"https://openalex.org/keywords/biomedical-engineering","display_name":"Biomedical engineering","score":0.4057163596153259},{"id":"https://openalex.org/keywords/computer-vision","display_name":"Computer vision","score":0.3946428894996643},{"id":"https://openalex.org/keywords/computer-science","display_name":"Computer science","score":0.38364535570144653},{"id":"https://openalex.org/keywords/artificial-intelligence","display_name":"Artificial intelligence","score":0.3454655408859253},{"id":"https://openalex.org/keywords/medicine","display_name":"Medicine","score":0.33772212266921997},{"id":"https://openalex.org/keywords/surgery","display_name":"Surgery","score":0.2744472622871399},{"id":"https://openalex.org/keywords/physics","display_name":"Physics","score":0.1098860502243042}],"concepts":[{"id":"https://openalex.org/C2781267111","wikidata":"https://www.wikidata.org/wiki/Q652297","display_name":"Catheter","level":2,"score":0.4908776879310608},{"id":"https://openalex.org/C2777822432","wikidata":"https://www.wikidata.org/wiki/Q216681","display_name":"In situ","level":2,"score":0.4672088027000427},{"id":"https://openalex.org/C136229726","wikidata":"https://www.wikidata.org/wiki/Q327092","display_name":"Biomedical engineering","level":1,"score":0.4057163596153259},{"id":"https://openalex.org/C31972630","wikidata":"https://www.wikidata.org/wiki/Q844240","display_name":"Computer vision","level":1,"score":0.3946428894996643},{"id":"https://openalex.org/C41008148","wikidata":"https://www.wikidata.org/wiki/Q21198","display_name":"Computer science","level":0,"score":0.38364535570144653},{"id":"https://openalex.org/C154945302","wikidata":"https://www.wikidata.org/wiki/Q11660","display_name":"Artificial intelligence","level":1,"score":0.3454655408859253},{"id":"https://openalex.org/C71924100","wikidata":"https://www.wikidata.org/wiki/Q11190","display_name":"Medicine","level":0,"score":0.33772212266921997},{"id":"https://openalex.org/C141071460","wikidata":"https://www.wikidata.org/wiki/Q40821","display_name":"Surgery","level":1,"score":0.2744472622871399},{"id":"https://openalex.org/C121332964","wikidata":"https://www.wikidata.org/wiki/Q413","display_name":"Physics","level":0,"score":0.1098860502243042},{"id":"https://openalex.org/C153294291","wikidata":"https://www.wikidata.org/wiki/Q25261","display_name":"Meteorology","level":1,"score":0.0}],"mesh":[],"locations_count":1,"locations":[{"id":"doi:10.1109/lra.2024.3474552","is_oa":false,"landing_page_url":"https://doi.org/10.1109/lra.2024.3474552","pdf_url":null,"source":{"id":"https://openalex.org/S4210169774","display_name":"IEEE Robotics and Automation Letters","issn_l":"2377-3766","issn":["2377-3766"],"is_oa":false,"is_in_doaj":false,"is_core":true,"host_organization":"https://openalex.org/P4310319808","host_organization_name":"Institute of Electrical and Electronics Engineers","host_organization_lineage":["https://openalex.org/P4310319808"],"host_organization_lineage_names":["Institute of Electrical and Electronics Engineers"],"type":"journal"},"license":null,"license_id":null,"version":"publishedVersion","is_accepted":true,"is_published":true,"raw_source_name":"IEEE Robotics and Automation Letters","raw_type":"journal-article"}],"best_oa_location":null,"sustainable_development_goals":[],"awards":[{"id":"https://openalex.org/G7529316824","display_name":null,"funder_award_id":"61803270","funder_id":"https://openalex.org/F4320321001","funder_display_name":"National Natural Science Foundation of China"}],"funders":[{"id":"https://openalex.org/F4320321001","display_name":"National Natural Science Foundation of China","ror":"https://ror.org/01h0zpd94"}],"has_content":{"grobid_xml":false,"pdf":false},"content_urls":null,"referenced_works_count":34,"referenced_works":["https://openalex.org/W2094904022","https://openalex.org/W2117248802","https://openalex.org/W2306331872","https://openalex.org/W2328731921","https://openalex.org/W2541128642","https://openalex.org/W2575426328","https://openalex.org/W2794254369","https://openalex.org/W2797542451","https://openalex.org/W2934318590","https://openalex.org/W2934681055","https://openalex.org/W2970769725","https://openalex.org/W2973098377","https://openalex.org/W2990249872","https://openalex.org/W3033847628","https://openalex.org/W3048892024","https://openalex.org/W3133156511","https://openalex.org/W3138516171","https://openalex.org/W3170841864","https://openalex.org/W3188838523","https://openalex.org/W3194935104","https://openalex.org/W3199236347","https://openalex.org/W3202343472","https://openalex.org/W4200391189","https://openalex.org/W4214661456","https://openalex.org/W4224438881","https://openalex.org/W4280598010","https://openalex.org/W4283322048","https://openalex.org/W4307669896","https://openalex.org/W4360853472","https://openalex.org/W4386017249","https://openalex.org/W4386412323","https://openalex.org/W4391258491","https://openalex.org/W4399185801","https://openalex.org/W6797784111"],"related_works":["https://openalex.org/W2058170566","https://openalex.org/W2755342338","https://openalex.org/W2772917594","https://openalex.org/W2166024367","https://openalex.org/W3116076068","https://openalex.org/W2229312674","https://openalex.org/W2951359407","https://openalex.org/W2079911747","https://openalex.org/W1969923398","https://openalex.org/W2775347418"],"abstract_inverted_index":{"Magnetic":[0],"soft":[1],"catheter":[2],"(MSC)":[3],"robots,":[4],"renowned":[5],"for":[6,15,30],"their":[7],"remarkable":[8],"flexibility":[9],"and":[10,19,24,91,104,132,157,182,203],"wireless":[11],"controllability,":[12],"are":[13],"suitable":[14],"operation":[16],"in":[17,21,62,187],"constrained":[18],"dynamic":[20],"vivo":[22,63],"environments,":[23],"they":[25],"have":[26,147],"shown":[27],"application":[28],"potential":[29,186],"in-situ":[31,37,79,112,134,158,177],"bioprinting.":[32,113],"Nonetheless,":[33],"this":[34],"type":[35],"of":[36,106,143,165,190,196],"bioprinting":[38,80,135,159,178],"systems":[39],"currently":[40],"lack":[41],"intraoperative":[42],"intelligent":[43],"defect":[44,164],"reconstruction":[45,120],"(DR)":[46],"techniques,":[47],"relying":[48],"solely":[49],"on":[50,88,154,161,198],"preoperative":[51],"imaging":[52],"to":[53,76,98,128,173],"guide":[54],"printing,":[55],"thereby":[56,110],"introducing":[57],"considerable":[58],"uncertainty":[59],"into":[60],"the":[61,101,107,117,130,144],"printing":[64,152],"procedure.":[65],"Here,":[66],"a":[67,122,162,188],"binocular":[68,92],"vision-assisted":[69],"MSC":[70,131],"robot":[71],"system":[72],"(BV-MSCRS)":[73],"is":[74,96,126],"reported":[75],"perform":[77],"automatic":[78],"with":[81,116],"minimal":[82],"incision.":[83],"A":[84],"DR":[85],"algorithm":[86],"based":[87],"deep":[89],"learning":[90],"stereo":[93],"matching":[94],"technology":[95,179],"developed":[97],"intelligently":[99],"reconstruct":[100],"3D":[102,119],"positions":[103],"morphologies":[105],"target":[108],"defects,":[109],"assisting":[111],"In":[114],"accordance":[115],"obtained":[118],"information,":[121],"magnetic":[123],"control":[124],"strategy":[125],"designed":[127],"actuate":[129],"execute":[133],"tasks":[136],"by":[137,150],"five":[138],"orthogonal":[139],"electromagnets.":[140],"The":[141],"effectiveness":[142],"proposed":[145],"BV-MSCRS":[146],"been":[148],"verified":[149],"in-vitro":[151],"experiments":[153,160],"planar":[155],"surfaces":[156],"cartilage":[163],"an":[166],"isolated":[167],"porcine":[168],"femur.":[169],"This":[170],"study":[171],"aspires":[172],"advance":[174],"minimally":[175],"invasive":[176],"toward":[180],"intelligence":[181],"automation,":[183],"exploring":[184],"its":[185],"diversity":[189],"clinical":[191],"applications,":[192],"such":[193],"as":[194],"repair":[195],"damage":[197],"cartilage,":[199],"muscle,":[200],"gastric":[201],"wall":[202],"liver.":[204]},"counts_by_year":[{"year":2026,"cited_by_count":2},{"year":2025,"cited_by_count":4}],"updated_date":"2026-03-27T05:58:40.876381","created_date":"2025-10-10T00:00:00"}
