{"id":"https://openalex.org/W3182293262","doi":"https://doi.org/10.1109/lra.2021.3095024","title":"Adjustable Compliance and Force Feedback as Key Elements for Stable and Efficient Hopping","display_name":"Adjustable Compliance and Force Feedback as Key Elements for Stable and Efficient Hopping","publication_year":2021,"publication_date":"2021-07-07","ids":{"openalex":"https://openalex.org/W3182293262","doi":"https://doi.org/10.1109/lra.2021.3095024","mag":"3182293262"},"language":"en","primary_location":{"id":"doi:10.1109/lra.2021.3095024","is_oa":false,"landing_page_url":"https://doi.org/10.1109/lra.2021.3095024","pdf_url":null,"source":{"id":"https://openalex.org/S4210169774","display_name":"IEEE Robotics and Automation Letters","issn_l":"2377-3766","issn":["2377-3766","2377-3774"],"is_oa":false,"is_in_doaj":false,"is_core":true,"host_organization":"https://openalex.org/P4310319808","host_organization_name":"Institute of Electrical and Electronics Engineers","host_organization_lineage":["https://openalex.org/P4310319808"],"host_organization_lineage_names":["Institute of Electrical and Electronics Engineers"],"type":"journal"},"license":null,"license_id":null,"version":"publishedVersion","is_accepted":true,"is_published":true,"raw_source_name":"IEEE Robotics and Automation Letters","raw_type":"journal-article"},"type":"article","indexed_in":["crossref"],"open_access":{"is_oa":false,"oa_status":"closed","oa_url":null,"any_repository_has_fulltext":false},"authorships":[{"author_position":"first","author":{"id":"https://openalex.org/A5033635074","display_name":"Rustam Galljamov","orcid":null},"institutions":[{"id":"https://openalex.org/I31512782","display_name":"Technische Universit\u00e4t Darmstadt","ror":"https://ror.org/05n911h24","country_code":"DE","type":"education","lineage":["https://openalex.org/I31512782"]}],"countries":["DE"],"is_corresponding":false,"raw_author_name":"Rustam Galljamov","raw_affiliation_strings":["Lauflabor Locomotion Laboratory, Centre for Cognitive Science, TU Darmstadt, Darmstadt, Germany"],"raw_orcid":null,"affiliations":[{"raw_affiliation_string":"Lauflabor Locomotion Laboratory, Centre for Cognitive Science, TU Darmstadt, Darmstadt, Germany","institution_ids":["https://openalex.org/I31512782"]}]},{"author_position":"middle","author":{"id":"https://openalex.org/A5048945250","display_name":"Arjang Ahmadi","orcid":"https://orcid.org/0000-0001-6810-6854"},"institutions":[{"id":"https://openalex.org/I31512782","display_name":"Technische Universit\u00e4t Darmstadt","ror":"https://ror.org/05n911h24","country_code":"DE","type":"education","lineage":["https://openalex.org/I31512782"]}],"countries":["DE"],"is_corresponding":false,"raw_author_name":"Arjang Ahmadi","raw_affiliation_strings":["Lauflabor Locomotion Laboratory, Centre for Cognitive Science, TU Darmstadt, Darmstadt, Germany"],"raw_orcid":null,"affiliations":[{"raw_affiliation_string":"Lauflabor Locomotion Laboratory, Centre for Cognitive Science, TU Darmstadt, Darmstadt, Germany","institution_ids":["https://openalex.org/I31512782"]}]},{"author_position":"middle","author":{"id":"https://openalex.org/A5012663809","display_name":"Omid Mohseni","orcid":"https://orcid.org/0000-0003-2601-1958"},"institutions":[{"id":"https://openalex.org/I31512782","display_name":"Technische Universit\u00e4t Darmstadt","ror":"https://ror.org/05n911h24","country_code":"DE","type":"education","lineage":["https://openalex.org/I31512782"]}],"countries":["DE"],"is_corresponding":false,"raw_author_name":"Omid Mohseni","raw_affiliation_strings":["Lauflabor Locomotion Laboratory, Centre for Cognitive Science, TU Darmstadt, Darmstadt, Germany"],"raw_orcid":"https://orcid.org/0000-0003-2601-1958","affiliations":[{"raw_affiliation_string":"Lauflabor Locomotion Laboratory, Centre for Cognitive Science, TU Darmstadt, Darmstadt, Germany","institution_ids":["https://openalex.org/I31512782"]}]},{"author_position":"middle","author":{"id":"https://openalex.org/A5015080938","display_name":"Andr\u00e9 Seyfarth","orcid":"https://orcid.org/0000-0001-8285-2415"},"institutions":[{"id":"https://openalex.org/I31512782","display_name":"Technische Universit\u00e4t Darmstadt","ror":"https://ror.org/05n911h24","country_code":"DE","type":"education","lineage":["https://openalex.org/I31512782"]}],"countries":["DE"],"is_corresponding":false,"raw_author_name":"Andre Seyfarth","raw_affiliation_strings":["Lauflabor Locomotion Laboratory, Centre for Cognitive Science, TU Darmstadt, Darmstadt, Germany"],"raw_orcid":null,"affiliations":[{"raw_affiliation_string":"Lauflabor Locomotion Laboratory, Centre for Cognitive Science, TU Darmstadt, Darmstadt, Germany","institution_ids":["https://openalex.org/I31512782"]}]},{"author_position":"middle","author":{"id":"https://openalex.org/A5082242689","display_name":"Philipp Beckerle","orcid":"https://orcid.org/0000-0001-5703-6029"},"institutions":[{"id":"https://openalex.org/I181369854","display_name":"Friedrich-Alexander-Universit\u00e4t Erlangen-N\u00fcrnberg","ror":"https://ror.org/00f7hpc57","country_code":"DE","type":"education","lineage":["https://openalex.org/I181369854"]},{"id":"https://openalex.org/I31512782","display_name":"Technische Universit\u00e4t Darmstadt","ror":"https://ror.org/05n911h24","country_code":"DE","type":"education","lineage":["https://openalex.org/I31512782"]}],"countries":["DE"],"is_corresponding":false,"raw_author_name":"Philipp Beckerle","raw_affiliation_strings":["Chair of Autonomous Systems and Mechatronics, Friedrich-Alexander-University Erlangen-N\u00fcrnberg, Erlangen, Germany","Institute for Mechatronic Systems, Dep. of Mechanical Engineering, TU Darmstadt, Darmstadt, Germany"],"raw_orcid":"https://orcid.org/0000-0001-5703-6029","affiliations":[{"raw_affiliation_string":"Chair of Autonomous Systems and Mechatronics, Friedrich-Alexander-University Erlangen-N\u00fcrnberg, Erlangen, Germany","institution_ids":["https://openalex.org/I181369854"]},{"raw_affiliation_string":"Institute for Mechatronic Systems, Dep. of Mechanical Engineering, TU Darmstadt, Darmstadt, Germany","institution_ids":["https://openalex.org/I31512782"]}]},{"author_position":"last","author":{"id":"https://openalex.org/A5017524660","display_name":"Maziar A. Sharbafi","orcid":"https://orcid.org/0000-0001-5727-7527"},"institutions":[{"id":"https://openalex.org/I31512782","display_name":"Technische Universit\u00e4t Darmstadt","ror":"https://ror.org/05n911h24","country_code":"DE","type":"education","lineage":["https://openalex.org/I31512782"]}],"countries":["DE"],"is_corresponding":false,"raw_author_name":"Maziar A. Sharbafi","raw_affiliation_strings":["Lauflabor Locomotion Laboratory, Centre for Cognitive Science, TU Darmstadt, Darmstadt, Germany"],"raw_orcid":"https://orcid.org/0000-0001-5727-7527","affiliations":[{"raw_affiliation_string":"Lauflabor Locomotion Laboratory, Centre for Cognitive Science, TU Darmstadt, Darmstadt, Germany","institution_ids":["https://openalex.org/I31512782"]}]}],"institutions":[],"countries_distinct_count":1,"institutions_distinct_count":2,"corresponding_author_ids":[],"corresponding_institution_ids":[],"apc_list":null,"apc_paid":null,"fwci":0.7256,"has_fulltext":false,"cited_by_count":11,"citation_normalized_percentile":{"value":0.64237043,"is_in_top_1_percent":false,"is_in_top_10_percent":false},"cited_by_percentile_year":{"min":89,"max":97},"biblio":{"volume":"6","issue":"4","first_page":"6797","last_page":"6804"},"is_retracted":false,"is_paratext":false,"is_xpac":false,"primary_topic":{"id":"https://openalex.org/T11023","display_name":"Prosthetics and Rehabilitation Robotics","score":0.9994000196456909,"subfield":{"id":"https://openalex.org/subfields/2204","display_name":"Biomedical Engineering"},"field":{"id":"https://openalex.org/fields/22","display_name":"Engineering"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}},"topics":[{"id":"https://openalex.org/T11023","display_name":"Prosthetics and Rehabilitation Robotics","score":0.9994000196456909,"subfield":{"id":"https://openalex.org/subfields/2204","display_name":"Biomedical Engineering"},"field":{"id":"https://openalex.org/fields/22","display_name":"Engineering"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}},{"id":"https://openalex.org/T10784","display_name":"Muscle activation and electromyography studies","score":0.9993000030517578,"subfield":{"id":"https://openalex.org/subfields/2204","display_name":"Biomedical Engineering"},"field":{"id":"https://openalex.org/fields/22","display_name":"Engineering"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}},{"id":"https://openalex.org/T10879","display_name":"Robotic Locomotion and Control","score":0.9990000128746033,"subfield":{"id":"https://openalex.org/subfields/2204","display_name":"Biomedical Engineering"},"field":{"id":"https://openalex.org/fields/22","display_name":"Engineering"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}}],"keywords":[{"id":"https://openalex.org/keywords/computer-science","display_name":"Computer science","score":0.5458202958106995},{"id":"https://openalex.org/keywords/stiffness","display_name":"Stiffness","score":0.5453746318817139},{"id":"https://openalex.org/keywords/control-theory","display_name":"Control theory (sociology)","score":0.5389555096626282},{"id":"https://openalex.org/keywords/robot","display_name":"Robot","score":0.5070483684539795},{"id":"https://openalex.org/keywords/impedance-control","display_name":"Impedance control","score":0.5015609264373779},{"id":"https://openalex.org/keywords/control","display_name":"Control (management)","score":0.4478974938392639},{"id":"https://openalex.org/keywords/ground-reaction-force","display_name":"Ground reaction force","score":0.44493475556373596},{"id":"https://openalex.org/keywords/key","display_name":"Key (lock)","score":0.4444957673549652},{"id":"https://openalex.org/keywords/compliance","display_name":"Compliance (psychology)","score":0.42577311396598816},{"id":"https://openalex.org/keywords/simulation","display_name":"Simulation","score":0.3610687851905823},{"id":"https://openalex.org/keywords/control-engineering","display_name":"Control engineering","score":0.33980774879455566},{"id":"https://openalex.org/keywords/engineering","display_name":"Engineering","score":0.24829044938087463},{"id":"https://openalex.org/keywords/artificial-intelligence","display_name":"Artificial intelligence","score":0.18456774950027466},{"id":"https://openalex.org/keywords/physics","display_name":"Physics","score":0.12322592735290527},{"id":"https://openalex.org/keywords/kinematics","display_name":"Kinematics","score":0.07066693902015686}],"concepts":[{"id":"https://openalex.org/C41008148","wikidata":"https://www.wikidata.org/wiki/Q21198","display_name":"Computer science","level":0,"score":0.5458202958106995},{"id":"https://openalex.org/C2779372316","wikidata":"https://www.wikidata.org/wiki/Q569057","display_name":"Stiffness","level":2,"score":0.5453746318817139},{"id":"https://openalex.org/C47446073","wikidata":"https://www.wikidata.org/wiki/Q5165890","display_name":"Control theory (sociology)","level":3,"score":0.5389555096626282},{"id":"https://openalex.org/C90509273","wikidata":"https://www.wikidata.org/wiki/Q11012","display_name":"Robot","level":2,"score":0.5070483684539795},{"id":"https://openalex.org/C2777984285","wikidata":"https://www.wikidata.org/wiki/Q17098134","display_name":"Impedance control","level":3,"score":0.5015609264373779},{"id":"https://openalex.org/C2775924081","wikidata":"https://www.wikidata.org/wiki/Q55608371","display_name":"Control (management)","level":2,"score":0.4478974938392639},{"id":"https://openalex.org/C96332660","wikidata":"https://www.wikidata.org/wiki/Q5610971","display_name":"Ground reaction force","level":3,"score":0.44493475556373596},{"id":"https://openalex.org/C26517878","wikidata":"https://www.wikidata.org/wiki/Q228039","display_name":"Key (lock)","level":2,"score":0.4444957673549652},{"id":"https://openalex.org/C2781460075","wikidata":"https://www.wikidata.org/wiki/Q1399332","display_name":"Compliance (psychology)","level":2,"score":0.42577311396598816},{"id":"https://openalex.org/C44154836","wikidata":"https://www.wikidata.org/wiki/Q45045","display_name":"Simulation","level":1,"score":0.3610687851905823},{"id":"https://openalex.org/C133731056","wikidata":"https://www.wikidata.org/wiki/Q4917288","display_name":"Control engineering","level":1,"score":0.33980774879455566},{"id":"https://openalex.org/C127413603","wikidata":"https://www.wikidata.org/wiki/Q11023","display_name":"Engineering","level":0,"score":0.24829044938087463},{"id":"https://openalex.org/C154945302","wikidata":"https://www.wikidata.org/wiki/Q11660","display_name":"Artificial intelligence","level":1,"score":0.18456774950027466},{"id":"https://openalex.org/C121332964","wikidata":"https://www.wikidata.org/wiki/Q413","display_name":"Physics","level":0,"score":0.12322592735290527},{"id":"https://openalex.org/C39920418","wikidata":"https://www.wikidata.org/wiki/Q11476","display_name":"Kinematics","level":2,"score":0.07066693902015686},{"id":"https://openalex.org/C77805123","wikidata":"https://www.wikidata.org/wiki/Q161272","display_name":"Social psychology","level":1,"score":0.0},{"id":"https://openalex.org/C15744967","wikidata":"https://www.wikidata.org/wiki/Q9418","display_name":"Psychology","level":0,"score":0.0},{"id":"https://openalex.org/C38652104","wikidata":"https://www.wikidata.org/wiki/Q3510521","display_name":"Computer security","level":1,"score":0.0},{"id":"https://openalex.org/C74650414","wikidata":"https://www.wikidata.org/wiki/Q11397","display_name":"Classical mechanics","level":1,"score":0.0},{"id":"https://openalex.org/C66938386","wikidata":"https://www.wikidata.org/wiki/Q633538","display_name":"Structural engineering","level":1,"score":0.0}],"mesh":[],"locations_count":1,"locations":[{"id":"doi:10.1109/lra.2021.3095024","is_oa":false,"landing_page_url":"https://doi.org/10.1109/lra.2021.3095024","pdf_url":null,"source":{"id":"https://openalex.org/S4210169774","display_name":"IEEE Robotics and Automation Letters","issn_l":"2377-3766","issn":["2377-3766","2377-3774"],"is_oa":false,"is_in_doaj":false,"is_core":true,"host_organization":"https://openalex.org/P4310319808","host_organization_name":"Institute of Electrical and Electronics Engineers","host_organization_lineage":["https://openalex.org/P4310319808"],"host_organization_lineage_names":["Institute of Electrical and Electronics Engineers"],"type":"journal"},"license":null,"license_id":null,"version":"publishedVersion","is_accepted":true,"is_published":true,"raw_source_name":"IEEE Robotics and Automation Letters","raw_type":"journal-article"}],"best_oa_location":null,"sustainable_development_goals":[{"score":0.41999998688697815,"id":"https://metadata.un.org/sdg/7","display_name":"Affordable and clean energy"}],"awards":[{"id":"https://openalex.org/G2538002645","display_name":null,"funder_award_id":"BE5729/1-2","funder_id":"https://openalex.org/F4320320879","funder_display_name":"Deutsche Forschungsgemeinschaft"},{"id":"https://openalex.org/G3541242013","display_name":null,"funder_award_id":"AH307/4-1","funder_id":"https://openalex.org/F4320320879","funder_display_name":"Deutsche Forschungsgemeinschaft"},{"id":"https://openalex.org/G617942264","display_name":null,"funder_award_id":"AH307/2-1","funder_id":"https://openalex.org/F4320320879","funder_display_name":"Deutsche Forschungsgemeinschaft"},{"id":"https://openalex.org/G7846475008","display_name":null,"funder_award_id":"SE1042/29-1","funder_id":"https://openalex.org/F4320320879","funder_display_name":"Deutsche Forschungsgemeinschaft"}],"funders":[{"id":"https://openalex.org/F4320320879","display_name":"Deutsche Forschungsgemeinschaft","ror":"https://ror.org/018mejw64"}],"has_content":{"grobid_xml":false,"pdf":false},"content_urls":null,"referenced_works_count":39,"referenced_works":["https://openalex.org/W846924096","https://openalex.org/W1519339220","https://openalex.org/W1970628739","https://openalex.org/W1974668501","https://openalex.org/W1976355201","https://openalex.org/W1981932940","https://openalex.org/W1983815930","https://openalex.org/W2008342119","https://openalex.org/W2013784146","https://openalex.org/W2020656842","https://openalex.org/W2103222398","https://openalex.org/W2108358935","https://openalex.org/W2111433948","https://openalex.org/W2116655729","https://openalex.org/W2119911729","https://openalex.org/W2130329603","https://openalex.org/W2148557558","https://openalex.org/W2151471214","https://openalex.org/W2158768486","https://openalex.org/W2159220301","https://openalex.org/W2174295199","https://openalex.org/W2345474674","https://openalex.org/W2461218157","https://openalex.org/W2755367247","https://openalex.org/W2765837012","https://openalex.org/W2771514906","https://openalex.org/W2772162865","https://openalex.org/W2898476307","https://openalex.org/W2912915165","https://openalex.org/W2920322937","https://openalex.org/W2963647792","https://openalex.org/W2967625847","https://openalex.org/W3089567617","https://openalex.org/W3091485967","https://openalex.org/W3094321085","https://openalex.org/W3101570653","https://openalex.org/W3166176831","https://openalex.org/W4248763805","https://openalex.org/W6623563090"],"related_works":["https://openalex.org/W2410395228","https://openalex.org/W3125941065","https://openalex.org/W4205440829","https://openalex.org/W2042469328","https://openalex.org/W2109413986","https://openalex.org/W4366371796","https://openalex.org/W2484615095","https://openalex.org/W4366371752","https://openalex.org/W2339265919","https://openalex.org/W2057538835"],"abstract_inverted_index":{"Achieving":[0],"efficient":[1,128],"and":[2,14,25,34,85,103,126],"human-like":[3,141],"hopping":[4,109,124,142],"motions":[5,125],"with":[6,42],"consistent":[7],"consecutive":[8],"patterns":[9,143],"requires":[10],"proper":[11],"mechanical":[12],"design":[13,24],"control.":[15,37],"In":[16],"this":[17],"regard,":[18],"we":[19,114],"introduce":[20],"a":[21,30,43,79,96],"new":[22],"bioinspired":[23],"control":[26,84,104],"approach":[27,77,120],"comprised":[28],"of":[29,69,82,138],"hybrid":[31],"actuation":[32],"system":[33,54,94],"force-based":[35],"compliance":[36],"Combining":[38],"an":[39],"electric":[40],"motor":[41],"pneumatic":[44],"artificial":[45],"muscle":[46],"makes":[47],"up":[48],"the":[49,58,62,73,91,118,146,150],"so-called":[50],"Electric-Pneumatic":[51],"Actuation":[52],"(EPA)":[53],"which":[55],"enables":[56],"presetting":[57],"leg":[59,74],"compliance.":[60],"Using":[61],"ground":[63],"reaction":[64],"force":[65],"for":[66,106],"online":[67],"adjustment":[68],"EPA":[70],"allows":[71],"controlling":[72],"stiffness.":[75],"This":[76],"combines":[78],"simplified":[80],"version":[81],"reflex-based":[83],"physical":[86],"impedance":[87],"adjustment,":[88],"that":[89,117],"resembles":[90],"human":[92],"neuromuscular":[93],"in":[95],"parsimonious":[97],"way.":[98],"By":[99],"optimizing":[100],"PAM":[101],"pressures":[102],"gains":[105],"different":[107],"targeted":[108],"heights":[110],"using":[111],"Bayesian":[112],"optimization,":[113],"show":[115],"experimentally":[116],"proposed":[119],"generates":[121],"various":[122],"stable":[123],"yields":[127],"performance.":[129],"Moreover,":[130],"our":[131],"method":[132],"is":[133],"shown":[134],"to":[135,145],"be":[136],"capable":[137],"creating":[139],"more":[140],"compared":[144],"previous":[147],"studies":[148],"on":[149],"same":[151],"robot.":[152]},"counts_by_year":[{"year":2025,"cited_by_count":1},{"year":2024,"cited_by_count":3},{"year":2023,"cited_by_count":2},{"year":2022,"cited_by_count":4},{"year":2021,"cited_by_count":1}],"updated_date":"2026-07-23T08:03:31.855105","created_date":"2025-10-10T00:00:00"}
