{"id":"https://openalex.org/W2913107198","doi":"https://doi.org/10.1109/lra.2019.2898320","title":"Robot Self-Calibration Using Multiple Kinematic Chains\u2014A Simulation Study on the iCub Humanoid Robot","display_name":"Robot Self-Calibration Using Multiple Kinematic Chains\u2014A Simulation Study on the iCub Humanoid Robot","publication_year":2019,"publication_date":"2019-02-09","ids":{"openalex":"https://openalex.org/W2913107198","doi":"https://doi.org/10.1109/lra.2019.2898320","mag":"2913107198"},"language":"en","primary_location":{"id":"doi:10.1109/lra.2019.2898320","is_oa":false,"landing_page_url":"https://doi.org/10.1109/lra.2019.2898320","pdf_url":null,"source":{"id":"https://openalex.org/S4210169774","display_name":"IEEE Robotics and Automation Letters","issn_l":"2377-3766","issn":["2377-3766","2377-3774"],"is_oa":false,"is_in_doaj":false,"is_core":true,"host_organization":"https://openalex.org/P4310319808","host_organization_name":"Institute of Electrical and Electronics Engineers","host_organization_lineage":["https://openalex.org/P4310319808"],"host_organization_lineage_names":["Institute of Electrical and Electronics Engineers"],"type":"journal"},"license":null,"license_id":null,"version":"publishedVersion","is_accepted":true,"is_published":true,"raw_source_name":"IEEE Robotics and Automation Letters","raw_type":"journal-article"},"type":"article","indexed_in":["arxiv","crossref"],"open_access":{"is_oa":true,"oa_status":"green","oa_url":"https://arxiv.org/pdf/1805.07263","any_repository_has_fulltext":true},"authorships":[{"author_position":"first","author":{"id":null,"display_name":"Karla Stepanova","orcid":"https://orcid.org/0000-0003-4239-2092"},"institutions":[{"id":"https://openalex.org/I44504214","display_name":"Czech Technical University in Prague","ror":"https://ror.org/03kqpb082","country_code":"CZ","type":"education","lineage":["https://openalex.org/I44504214"]}],"countries":["CZ"],"is_corresponding":false,"raw_author_name":"Karla Stepanova","raw_affiliation_strings":["Department of Cybernetics, Faculty of Electrical Engineering, and the Czech Institute of Informatics, Robotics, and Cybernetics, Czech Technical University, Prague, Czech Republic"],"raw_orcid":"https://orcid.org/0000-0003-4239-2092","affiliations":[{"raw_affiliation_string":"Department of Cybernetics, Faculty of Electrical Engineering, and the Czech Institute of Informatics, Robotics, and Cybernetics, Czech Technical University, Prague, Czech Republic","institution_ids":["https://openalex.org/I44504214"]}]},{"author_position":"middle","author":{"id":null,"display_name":"Tomas Pajdla","orcid":null},"institutions":[{"id":"https://openalex.org/I44504214","display_name":"Czech Technical University in Prague","ror":"https://ror.org/03kqpb082","country_code":"CZ","type":"education","lineage":["https://openalex.org/I44504214"]}],"countries":["CZ"],"is_corresponding":false,"raw_author_name":"Tomas Pajdla","raw_affiliation_strings":["Czech Institute of Informatics, Robotics, and Cybernetics, Czech Technical University, Prague, Czech Republic"],"raw_orcid":null,"affiliations":[{"raw_affiliation_string":"Czech Institute of Informatics, Robotics, and Cybernetics, Czech Technical University, Prague, Czech Republic","institution_ids":["https://openalex.org/I44504214"]}]},{"author_position":"last","author":{"id":null,"display_name":"Matej Hoffmann","orcid":"https://orcid.org/0000-0001-8137-3412"},"institutions":[{"id":"https://openalex.org/I44504214","display_name":"Czech Technical University in Prague","ror":"https://ror.org/03kqpb082","country_code":"CZ","type":"education","lineage":["https://openalex.org/I44504214"]}],"countries":["CZ"],"is_corresponding":false,"raw_author_name":"Matej Hoffmann","raw_affiliation_strings":["Department of Cybernetics, Faculty of Electrical Engineering, Czech Technical University, Prague, Czech Republic"],"raw_orcid":"https://orcid.org/0000-0001-8137-3412","affiliations":[{"raw_affiliation_string":"Department of Cybernetics, Faculty of Electrical Engineering, Czech Technical University, Prague, Czech Republic","institution_ids":["https://openalex.org/I44504214"]}]}],"institutions":[],"countries_distinct_count":1,"institutions_distinct_count":1,"corresponding_author_ids":[],"corresponding_institution_ids":["https://openalex.org/I44504214"],"apc_list":{"value":2645,"currency":"USD","value_usd":2645},"apc_paid":null,"fwci":1.4197,"has_fulltext":false,"cited_by_count":28,"citation_normalized_percentile":{"value":0.78923532,"is_in_top_1_percent":false,"is_in_top_10_percent":false},"cited_by_percentile_year":{"min":94,"max":99},"biblio":{"volume":"4","issue":"2","first_page":"1900","last_page":"1907"},"is_retracted":false,"is_paratext":false,"is_xpac":false,"primary_topic":{"id":"https://openalex.org/T10879","display_name":"Robotic Locomotion and Control","score":0.7735999822616577,"subfield":{"id":"https://openalex.org/subfields/2204","display_name":"Biomedical Engineering"},"field":{"id":"https://openalex.org/fields/22","display_name":"Engineering"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}},"topics":[{"id":"https://openalex.org/T10879","display_name":"Robotic Locomotion and Control","score":0.7735999822616577,"subfield":{"id":"https://openalex.org/subfields/2204","display_name":"Biomedical Engineering"},"field":{"id":"https://openalex.org/fields/22","display_name":"Engineering"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}},{"id":"https://openalex.org/T10653","display_name":"Robot Manipulation and Learning","score":0.08649999648332596,"subfield":{"id":"https://openalex.org/subfields/2207","display_name":"Control and Systems Engineering"},"field":{"id":"https://openalex.org/fields/22","display_name":"Engineering"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}},{"id":"https://openalex.org/T11023","display_name":"Prosthetics and Rehabilitation Robotics","score":0.03680000081658363,"subfield":{"id":"https://openalex.org/subfields/2204","display_name":"Biomedical Engineering"},"field":{"id":"https://openalex.org/fields/22","display_name":"Engineering"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}}],"keywords":[{"id":"https://openalex.org/keywords/icub","display_name":"iCub","score":0.9697999954223633},{"id":"https://openalex.org/keywords/kinematics","display_name":"Kinematics","score":0.7978000044822693},{"id":"https://openalex.org/keywords/humanoid-robot","display_name":"Humanoid robot","score":0.6931999921798706},{"id":"https://openalex.org/keywords/calibration","display_name":"Calibration","score":0.5407000184059143},{"id":"https://openalex.org/keywords/robot","display_name":"Robot","score":0.5370000004768372},{"id":"https://openalex.org/keywords/robot-calibration","display_name":"Robot calibration","score":0.5267999768257141},{"id":"https://openalex.org/keywords/kinematic-chain","display_name":"Kinematic chain","score":0.5230000019073486}],"concepts":[{"id":"https://openalex.org/C111151474","wikidata":"https://www.wikidata.org/wiki/Q1653368","display_name":"iCub","level":4,"score":0.9697999954223633},{"id":"https://openalex.org/C39920418","wikidata":"https://www.wikidata.org/wiki/Q11476","display_name":"Kinematics","level":2,"score":0.7978000044822693},{"id":"https://openalex.org/C60692881","wikidata":"https://www.wikidata.org/wiki/Q584529","display_name":"Humanoid robot","level":3,"score":0.6931999921798706},{"id":"https://openalex.org/C41008148","wikidata":"https://www.wikidata.org/wiki/Q21198","display_name":"Computer science","level":0,"score":0.6021000146865845},{"id":"https://openalex.org/C31972630","wikidata":"https://www.wikidata.org/wiki/Q844240","display_name":"Computer vision","level":1,"score":0.5839999914169312},{"id":"https://openalex.org/C165838908","wikidata":"https://www.wikidata.org/wiki/Q736777","display_name":"Calibration","level":2,"score":0.5407000184059143},{"id":"https://openalex.org/C154945302","wikidata":"https://www.wikidata.org/wiki/Q11660","display_name":"Artificial intelligence","level":1,"score":0.5372999906539917},{"id":"https://openalex.org/C90509273","wikidata":"https://www.wikidata.org/wiki/Q11012","display_name":"Robot","level":2,"score":0.5370000004768372},{"id":"https://openalex.org/C192299074","wikidata":"https://www.wikidata.org/wiki/Q2160034","display_name":"Robot calibration","level":5,"score":0.5267999768257141},{"id":"https://openalex.org/C62837456","wikidata":"https://www.wikidata.org/wiki/Q678308","display_name":"Kinematic chain","level":3,"score":0.5230000019073486},{"id":"https://openalex.org/C149810388","wikidata":"https://www.wikidata.org/wiki/Q5374873","display_name":"Emulation","level":2,"score":0.5022000074386597},{"id":"https://openalex.org/C46722567","wikidata":"https://www.wikidata.org/wiki/Q7674139","display_name":"Tactile sensor","level":3,"score":0.4496000111103058},{"id":"https://openalex.org/C74222875","wikidata":"https://www.wikidata.org/wiki/Q16000312","display_name":"Robot kinematics","level":4,"score":0.4325000047683716},{"id":"https://openalex.org/C44154836","wikidata":"https://www.wikidata.org/wiki/Q45045","display_name":"Simulation","level":1,"score":0.4002000093460083},{"id":"https://openalex.org/C34413123","wikidata":"https://www.wikidata.org/wiki/Q170978","display_name":"Robotics","level":3,"score":0.3871000111103058},{"id":"https://openalex.org/C99498987","wikidata":"https://www.wikidata.org/wiki/Q2210247","display_name":"Noise (video)","level":3,"score":0.3743000030517578},{"id":"https://openalex.org/C175291020","wikidata":"https://www.wikidata.org/wiki/Q1156822","display_name":"Offset (computer science)","level":2,"score":0.3671000003814697},{"id":"https://openalex.org/C127413603","wikidata":"https://www.wikidata.org/wiki/Q11023","display_name":"Engineering","level":0,"score":0.2791000008583069},{"id":"https://openalex.org/C47446073","wikidata":"https://www.wikidata.org/wiki/Q5165890","display_name":"Control theory (sociology)","level":3,"score":0.2705000042915344},{"id":"https://openalex.org/C43711488","wikidata":"https://www.wikidata.org/wiki/Q7534783","display_name":"Skew","level":2,"score":0.2702000141143799}],"mesh":[],"locations_count":2,"locations":[{"id":"doi:10.1109/lra.2019.2898320","is_oa":false,"landing_page_url":"https://doi.org/10.1109/lra.2019.2898320","pdf_url":null,"source":{"id":"https://openalex.org/S4210169774","display_name":"IEEE Robotics and Automation Letters","issn_l":"2377-3766","issn":["2377-3766","2377-3774"],"is_oa":false,"is_in_doaj":false,"is_core":true,"host_organization":"https://openalex.org/P4310319808","host_organization_name":"Institute of Electrical and Electronics Engineers","host_organization_lineage":["https://openalex.org/P4310319808"],"host_organization_lineage_names":["Institute of Electrical and Electronics Engineers"],"type":"journal"},"license":null,"license_id":null,"version":"publishedVersion","is_accepted":true,"is_published":true,"raw_source_name":"IEEE Robotics and Automation Letters","raw_type":"journal-article"},{"id":"pmh:oai:arXiv.org:1805.07263","is_oa":true,"landing_page_url":"http://arxiv.org/abs/1805.07263","pdf_url":"https://arxiv.org/pdf/1805.07263","source":{"id":"https://openalex.org/S4306400194","display_name":"arXiv (Cornell University)","issn_l":"2331-8422","issn":["2331-8422"],"is_oa":true,"is_in_doaj":false,"is_core":false,"host_organization":"https://openalex.org/I205783295","host_organization_name":"Cornell University","host_organization_lineage":["https://openalex.org/I205783295"],"host_organization_lineage_names":[],"type":"repository"},"license":null,"license_id":null,"version":"submittedVersion","is_accepted":false,"is_published":false,"raw_source_name":null,"raw_type":"text"}],"best_oa_location":{"id":"pmh:oai:arXiv.org:1805.07263","is_oa":true,"landing_page_url":"http://arxiv.org/abs/1805.07263","pdf_url":"https://arxiv.org/pdf/1805.07263","source":{"id":"https://openalex.org/S4306400194","display_name":"arXiv (Cornell University)","issn_l":"2331-8422","issn":["2331-8422"],"is_oa":true,"is_in_doaj":false,"is_core":false,"host_organization":"https://openalex.org/I205783295","host_organization_name":"Cornell University","host_organization_lineage":["https://openalex.org/I205783295"],"host_organization_lineage_names":[],"type":"repository"},"license":null,"license_id":null,"version":"submittedVersion","is_accepted":false,"is_published":false,"raw_source_name":null,"raw_type":"text"},"sustainable_development_goals":[],"awards":[{"id":"https://openalex.org/G6006929117","display_name":null,"funder_award_id":"CZ.02.1.01/0.0/0.0/15 003/0000470","funder_id":"https://openalex.org/F4320335322","funder_display_name":"European Regional Development Fund"},{"id":"https://openalex.org/G7090158789","display_name":"Robot self-calibration and safe physical human-robot interaction inspired by body representations in primate brains","funder_award_id":"GJ17-15697Y","funder_id":"https://openalex.org/F4320321006","funder_display_name":"Grantov\u00e1 Agentura \u010cesk\u00e9 Republiky"}],"funders":[{"id":"https://openalex.org/F4320321006","display_name":"Grantov\u00e1 Agentura \u010cesk\u00e9 Republiky","ror":"https://ror.org/01pv73b02"},{"id":"https://openalex.org/F4320335322","display_name":"European Regional Development Fund","ror":"https://ror.org/00k4n6c32"}],"has_content":{"pdf":false,"grobid_xml":false},"content_urls":null,"referenced_works_count":25,"referenced_works":["https://openalex.org/W1974165152","https://openalex.org/W1988195118","https://openalex.org/W2001737341","https://openalex.org/W2029809384","https://openalex.org/W2060349787","https://openalex.org/W2066691972","https://openalex.org/W2108197520","https://openalex.org/W2117248802","https://openalex.org/W2128963970","https://openalex.org/W2144913215","https://openalex.org/W2159237582","https://openalex.org/W2200717876","https://openalex.org/W2301129842","https://openalex.org/W2466053294","https://openalex.org/W2511197415","https://openalex.org/W2566683778","https://openalex.org/W2568297126","https://openalex.org/W2724121612","https://openalex.org/W2765445970","https://openalex.org/W2771502785","https://openalex.org/W2801487100","https://openalex.org/W4244912679","https://openalex.org/W4255852758","https://openalex.org/W6623016026","https://openalex.org/W6765744053"],"related_works":[],"abstract_inverted_index":{"Mechanism":[0],"calibration":[1,34,69,203],"is":[2,154,188],"an":[3],"important":[4],"and":[5,23,58,90,101,121,152,205,220],"nontrivial":[6],"task":[7],"in":[8,11,39,127,156],"robotics.":[9],"Advances":[10],"sensor":[12],"technology":[13],"make":[14],"affordable":[15],"but":[16],"increasingly":[17],"accurate":[18],"devices":[19],"such":[20],"as":[21,86,134,161,163],"cameras":[22],"tactile":[24],"sensors":[25],"available,":[26],"making":[27],"it":[28],"possible":[29],"to":[30,62,104,173,178,202,224],"perform":[31],"automated":[32],"self-contained":[33],"relying":[35,236],"on":[36,237],"redundant":[37],"information":[38],"these":[40],"sensory":[41,226],"streams.":[42],"In":[43],"this":[44,238],"letter,":[45],"we":[46],"use":[47],"a":[48,54,140,185,225],"simulated":[49],"iCub":[50],"humanoid":[51],"robot":[52],"with":[53,206],"stereo":[55],"camera":[56,187],"system":[57],"end-effector":[59,128,210],"contact":[60],"emulation":[61],"quantitatively":[63],"compare":[64],"the":[65,234],"performance":[66,176,229],"of":[67,74,92,108,111,116,124,139,158,192,212,230],"kinematic":[68,76,94,112,149],"by":[70,146],"employing":[71,147,233],"different":[72],"combinations":[73],"intersecting":[75,93],"chains-either":[77],"through":[78],"self-observation":[79],"or":[80],"self-touch.":[81],"The":[82,130],"parameters":[83,100,138,191],"varied":[84],"were":[85],"follows:":[87,135],"first,":[88],"type":[89],"number":[91,115],"chains":[95,102,150,194,235],"used":[96,118],"for":[97,119,180],"calibration,":[98,169],"second,":[99],"subject":[103,201],"optimization,":[105,120],"third,":[106],"amount":[107,123],"initial":[109],"perturbation":[110],"parameters,":[113],"fourth,":[114],"poses/configurations":[117],"fifth,":[122],"measurement":[125],"noise":[126,223],"positions/cameras.":[129],"main":[131],"findings":[132],"are":[133],"1)":[136],"calibrating":[137],"single":[141,186],"chain":[142],"(e.g.,":[143],"one":[144],"arm)":[145],"multiple":[148],"(\u201cself-observation\u201d":[151],"\u201cself-touch\u201d)":[153],"superior":[155],"terms":[157],"optimization":[159],"results":[160],"well":[162],"observability;":[164],"2)":[165],"when":[166],"using":[167],"multichain":[168],"fewer":[170],"poses":[171],"suffice":[172],"get":[174],"similar":[175],"compared":[177],"when,":[179],"example,":[181],"only":[182],"observation":[183],"from":[184],"used;":[189],"3)":[190],"all":[193,231],"(here":[195],"86":[196],"DH":[197],"parameters)":[198],"can":[199,217],"be":[200,218],"simultaneously":[204],"50":[207],"(100)":[208],"poses,":[209],"error":[211],"around":[213],"2":[214],"(1)":[215],"mm":[216],"achieved;":[219],"4)":[221],"adding":[222],"modality":[227],"degrades":[228],"calibrations":[232],"information.":[239]},"counts_by_year":[{"year":2025,"cited_by_count":2},{"year":2024,"cited_by_count":5},{"year":2023,"cited_by_count":4},{"year":2022,"cited_by_count":6},{"year":2021,"cited_by_count":9},{"year":2019,"cited_by_count":2}],"updated_date":"2026-08-21T09:56:20.448147","created_date":"2019-02-21T00:00:00"}
