{"id":"https://openalex.org/W4406321795","doi":"https://doi.org/10.1109/les.2025.3528415","title":"A Robust VMD-PCA Integrated Approach for Accurate Respiration Parameter Estimation From PPG Signals","display_name":"A Robust VMD-PCA Integrated Approach for Accurate Respiration Parameter Estimation From PPG Signals","publication_year":2025,"publication_date":"2025-01-13","ids":{"openalex":"https://openalex.org/W4406321795","doi":"https://doi.org/10.1109/les.2025.3528415"},"language":"en","primary_location":{"id":"doi:10.1109/les.2025.3528415","is_oa":false,"landing_page_url":"https://doi.org/10.1109/les.2025.3528415","pdf_url":null,"source":{"id":"https://openalex.org/S22443479","display_name":"IEEE Embedded Systems Letters","issn_l":"1943-0663","issn":["1943-0663","1943-0671"],"is_oa":false,"is_in_doaj":false,"is_core":true,"host_organization":"https://openalex.org/P4310319808","host_organization_name":"Institute of Electrical and Electronics Engineers","host_organization_lineage":["https://openalex.org/P4310319808"],"host_organization_lineage_names":["Institute of Electrical and Electronics Engineers"],"type":"journal"},"license":null,"license_id":null,"version":"publishedVersion","is_accepted":true,"is_published":true,"raw_source_name":"IEEE Embedded Systems Letters","raw_type":"journal-article"},"type":"article","indexed_in":["crossref"],"open_access":{"is_oa":false,"oa_status":"closed","oa_url":null,"any_repository_has_fulltext":false},"authorships":[{"author_position":"first","author":{"id":"https://openalex.org/A5048431560","display_name":"Amit Bhongade","orcid":"https://orcid.org/0000-0001-7375-9438"},"institutions":[{"id":"https://openalex.org/I68891433","display_name":"Indian Institute of Technology Delhi","ror":"https://ror.org/049tgcd06","country_code":"IN","type":"education","lineage":["https://openalex.org/I68891433"]}],"countries":["IN"],"is_corresponding":true,"raw_author_name":"Amit Bhongade","raw_affiliation_strings":["Department of Electrical Engineering, Indian Institute of Technology Delhi, New Delhi, India","Department of Electrical Engineering, Indian Institute of Technology, Delhi, India"],"affiliations":[{"raw_affiliation_string":"Department of Electrical Engineering, Indian Institute of Technology Delhi, New Delhi, India","institution_ids":["https://openalex.org/I68891433"]},{"raw_affiliation_string":"Department of Electrical Engineering, Indian Institute of Technology, Delhi, India","institution_ids":["https://openalex.org/I68891433"]}]},{"author_position":"middle","author":{"id":"https://openalex.org/A5074080229","display_name":"Prathosh AP","orcid":"https://orcid.org/0000-0002-8699-5760"},"institutions":[{"id":"https://openalex.org/I59270414","display_name":"Indian Institute of Science Bangalore","ror":"https://ror.org/04dese585","country_code":"IN","type":"education","lineage":["https://openalex.org/I59270414"]}],"countries":["IN"],"is_corresponding":false,"raw_author_name":"A. P. Prathosh","raw_affiliation_strings":["Department of Electrical Communication Engineering, Indian Institute of Science Banglore, Bengaluru, India","Department of Electrical Communication Engineering, Indian Institute of Science Banglore, Bengaluru, Karnataka, India"],"affiliations":[{"raw_affiliation_string":"Department of Electrical Communication Engineering, Indian Institute of Science Banglore, Bengaluru, India","institution_ids":["https://openalex.org/I59270414"]},{"raw_affiliation_string":"Department of Electrical Communication Engineering, Indian Institute of Science Banglore, Bengaluru, Karnataka, India","institution_ids":["https://openalex.org/I59270414"]}]},{"author_position":"last","author":{"id":"https://openalex.org/A5052347493","display_name":"Tapan Kumar Gandhi","orcid":"https://orcid.org/0000-0002-3532-9389"},"institutions":[{"id":"https://openalex.org/I68891433","display_name":"Indian Institute of Technology Delhi","ror":"https://ror.org/049tgcd06","country_code":"IN","type":"education","lineage":["https://openalex.org/I68891433"]}],"countries":["IN"],"is_corresponding":false,"raw_author_name":"Tapan Kumar Gandhi","raw_affiliation_strings":["Department of Electrical Engineering, Indian Institute of Technology Delhi, New Delhi, India","Department of Electrical Engineering, Indian Institute of Technology, Delhi, India"],"affiliations":[{"raw_affiliation_string":"Department of Electrical Engineering, Indian Institute of Technology Delhi, New Delhi, India","institution_ids":["https://openalex.org/I68891433"]},{"raw_affiliation_string":"Department of Electrical Engineering, Indian Institute of Technology, Delhi, India","institution_ids":["https://openalex.org/I68891433"]}]}],"institutions":[],"countries_distinct_count":1,"institutions_distinct_count":3,"corresponding_author_ids":["https://openalex.org/A5048431560"],"corresponding_institution_ids":["https://openalex.org/I68891433"],"apc_list":null,"apc_paid":null,"fwci":1.3907,"has_fulltext":false,"cited_by_count":2,"citation_normalized_percentile":{"value":0.77123734,"is_in_top_1_percent":false,"is_in_top_10_percent":false},"cited_by_percentile_year":{"min":95,"max":96},"biblio":{"volume":"17","issue":"4","first_page":"230","last_page":"233"},"is_retracted":false,"is_paratext":false,"is_xpac":false,"primary_topic":{"id":"https://openalex.org/T11196","display_name":"Non-Invasive Vital Sign Monitoring","score":0.9988999962806702,"subfield":{"id":"https://openalex.org/subfields/2204","display_name":"Biomedical Engineering"},"field":{"id":"https://openalex.org/fields/22","display_name":"Engineering"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}},"topics":[{"id":"https://openalex.org/T11196","display_name":"Non-Invasive Vital Sign Monitoring","score":0.9988999962806702,"subfield":{"id":"https://openalex.org/subfields/2204","display_name":"Biomedical Engineering"},"field":{"id":"https://openalex.org/fields/22","display_name":"Engineering"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}},{"id":"https://openalex.org/T10745","display_name":"Heart Rate Variability and Autonomic Control","score":0.9453999996185303,"subfield":{"id":"https://openalex.org/subfields/2705","display_name":"Cardiology and Cardiovascular Medicine"},"field":{"id":"https://openalex.org/fields/27","display_name":"Medicine"},"domain":{"id":"https://openalex.org/domains/4","display_name":"Health Sciences"}},{"id":"https://openalex.org/T11700","display_name":"Hemodynamic Monitoring and Therapy","score":0.9375,"subfield":{"id":"https://openalex.org/subfields/2746","display_name":"Surgery"},"field":{"id":"https://openalex.org/fields/27","display_name":"Medicine"},"domain":{"id":"https://openalex.org/domains/4","display_name":"Health Sciences"}}],"keywords":[{"id":"https://openalex.org/keywords/computer-science","display_name":"Computer science","score":0.7811345458030701},{"id":"https://openalex.org/keywords/artificial-intelligence","display_name":"Artificial intelligence","score":0.5439590811729431},{"id":"https://openalex.org/keywords/pattern-recognition","display_name":"Pattern recognition (psychology)","score":0.4687725901603699},{"id":"https://openalex.org/keywords/estimation","display_name":"Estimation","score":0.44387584924697876},{"id":"https://openalex.org/keywords/principal-component-analysis","display_name":"Principal component analysis","score":0.4177086651325226},{"id":"https://openalex.org/keywords/computer-vision","display_name":"Computer vision","score":0.4099089503288269}],"concepts":[{"id":"https://openalex.org/C41008148","wikidata":"https://www.wikidata.org/wiki/Q21198","display_name":"Computer science","level":0,"score":0.7811345458030701},{"id":"https://openalex.org/C154945302","wikidata":"https://www.wikidata.org/wiki/Q11660","display_name":"Artificial intelligence","level":1,"score":0.5439590811729431},{"id":"https://openalex.org/C153180895","wikidata":"https://www.wikidata.org/wiki/Q7148389","display_name":"Pattern recognition (psychology)","level":2,"score":0.4687725901603699},{"id":"https://openalex.org/C96250715","wikidata":"https://www.wikidata.org/wiki/Q965330","display_name":"Estimation","level":2,"score":0.44387584924697876},{"id":"https://openalex.org/C27438332","wikidata":"https://www.wikidata.org/wiki/Q2873","display_name":"Principal component analysis","level":2,"score":0.4177086651325226},{"id":"https://openalex.org/C31972630","wikidata":"https://www.wikidata.org/wiki/Q844240","display_name":"Computer vision","level":1,"score":0.4099089503288269},{"id":"https://openalex.org/C162324750","wikidata":"https://www.wikidata.org/wiki/Q8134","display_name":"Economics","level":0,"score":0.0},{"id":"https://openalex.org/C187736073","wikidata":"https://www.wikidata.org/wiki/Q2920921","display_name":"Management","level":1,"score":0.0}],"mesh":[],"locations_count":1,"locations":[{"id":"doi:10.1109/les.2025.3528415","is_oa":false,"landing_page_url":"https://doi.org/10.1109/les.2025.3528415","pdf_url":null,"source":{"id":"https://openalex.org/S22443479","display_name":"IEEE Embedded Systems Letters","issn_l":"1943-0663","issn":["1943-0663","1943-0671"],"is_oa":false,"is_in_doaj":false,"is_core":true,"host_organization":"https://openalex.org/P4310319808","host_organization_name":"Institute of Electrical and Electronics Engineers","host_organization_lineage":["https://openalex.org/P4310319808"],"host_organization_lineage_names":["Institute of Electrical and Electronics Engineers"],"type":"journal"},"license":null,"license_id":null,"version":"publishedVersion","is_accepted":true,"is_published":true,"raw_source_name":"IEEE Embedded Systems Letters","raw_type":"journal-article"}],"best_oa_location":null,"sustainable_development_goals":[],"awards":[],"funders":[],"has_content":{"pdf":false,"grobid_xml":false},"content_urls":null,"referenced_works_count":15,"referenced_works":["https://openalex.org/W2000982976","https://openalex.org/W2124106073","https://openalex.org/W2532195385","https://openalex.org/W2904389702","https://openalex.org/W2916455725","https://openalex.org/W2954077523","https://openalex.org/W2954479804","https://openalex.org/W3082052804","https://openalex.org/W4226193028","https://openalex.org/W4310667967","https://openalex.org/W4385575061","https://openalex.org/W4389576992","https://openalex.org/W4391264523","https://openalex.org/W4399727990","https://openalex.org/W6761898732"],"related_works":["https://openalex.org/W2772917594","https://openalex.org/W2036807459","https://openalex.org/W2058170566","https://openalex.org/W2755342338","https://openalex.org/W2166024367","https://openalex.org/W3116076068","https://openalex.org/W2229312674","https://openalex.org/W2951359407","https://openalex.org/W2079911747","https://openalex.org/W1969923398"],"abstract_inverted_index":{"Photoplethysmography":[0],"(PPG)":[1],"signals":[2],"are":[3],"extensively":[4],"used":[5],"for":[6,93,116],"nonintrusive":[7],"health":[8,118],"monitoring,":[9],"including":[10],"deriving":[11],"cardiorespiratory":[12],"parameters.":[13],"However,":[14],"current":[15],"approaches":[16],"often":[17],"face":[18],"challenges":[19],"with":[20,33,66,107],"complexity":[21],"and":[22,60,85],"noise":[23],"susceptibility.":[24],"This":[25],"study":[26],"proposes":[27],"a":[28,44],"novel":[29],"variational":[30],"mode":[31],"decomposition":[32],"principal":[34],"component":[35],"analysis":[36],"(VMD-PCA)":[37],"method":[38,49],"to":[39,110],"estimate":[40],"respiratory":[41],"parameters":[42],"from":[43],"single":[45],"PPG":[46],"signal.":[47],"The":[48],"was":[50],"tested":[51],"on":[52],"ten":[53],"healthy":[54],"volunteers":[55],"breathing":[56],"at":[57],"normal,":[58],"fast,":[59],"slow":[61],"rates,":[62],"showing":[63],"robust":[64],"performance":[65,106],"an":[67],"average":[68],"RMSE":[69],"of":[70],"<inline-formula":[71,78,86],"xmlns:mml=\"http://www.w3.org/1998/Math/MathML\"":[72,79,87],"xmlns:xlink=\"http://www.w3.org/1999/xlink\">":[73,80,88],"<tex-math":[74,81,89],"notation=\"LaTeX\">$3.23{\\pm":[75],"}0.69$":[76],"</tex-math></inline-formula>,":[77,84],"notation=\"LaTeX\">$21.69{\\pm":[82],"}10.31$":[83],"notation=\"LaTeX\">$3.14{\\pm":[90],"}1.35$":[91],"</tex-math></inline-formula>":[92],"each":[94],"respiration":[95],"rate":[96],"(RR),":[97],"respectively.":[98],"Results":[99],"indicate":[100],"that":[101],"VMD-PCA":[102],"offers":[103],"reliable":[104],"real-time":[105],"enhanced":[108],"resilience":[109],"motion":[111],"artifacts,":[112],"demonstrating":[113],"its":[114],"potential":[115],"practical":[117],"monitoring":[119],"applications.":[120]},"counts_by_year":[{"year":2025,"cited_by_count":2}],"updated_date":"2025-12-23T23:11:35.936235","created_date":"2025-10-10T00:00:00"}
