{"id":"https://openalex.org/W4405092398","doi":"https://doi.org/10.1109/les.2024.3443449","title":"An Explainable and Formal Framework for Hypertension Monitoring Using ECG and PPG","display_name":"An Explainable and Formal Framework for Hypertension Monitoring Using ECG and PPG","publication_year":2024,"publication_date":"2024-12-01","ids":{"openalex":"https://openalex.org/W4405092398","doi":"https://doi.org/10.1109/les.2024.3443449"},"language":"en","primary_location":{"id":"doi:10.1109/les.2024.3443449","is_oa":false,"landing_page_url":"https://doi.org/10.1109/les.2024.3443449","pdf_url":null,"source":{"id":"https://openalex.org/S22443479","display_name":"IEEE Embedded Systems Letters","issn_l":"1943-0663","issn":["1943-0663","1943-0671"],"is_oa":false,"is_in_doaj":false,"is_core":true,"host_organization":"https://openalex.org/P4310319808","host_organization_name":"Institute of Electrical and Electronics Engineers","host_organization_lineage":["https://openalex.org/P4310319808"],"host_organization_lineage_names":["Institute of Electrical and Electronics Engineers"],"type":"journal"},"license":null,"license_id":null,"version":"publishedVersion","is_accepted":true,"is_published":true,"raw_source_name":"IEEE Embedded Systems Letters","raw_type":"journal-article"},"type":"article","indexed_in":["crossref"],"open_access":{"is_oa":false,"oa_status":"closed","oa_url":null,"any_repository_has_fulltext":false},"authorships":[{"author_position":"first","author":{"id":"https://openalex.org/A5038571565","display_name":"Abhinandan Panda","orcid":"https://orcid.org/0000-0001-5469-7032"},"institutions":[{"id":"https://openalex.org/I99729588","display_name":"Indian Institute of Technology Bhubaneswar","ror":"https://ror.org/04gx72j20","country_code":"IN","type":"education","lineage":["https://openalex.org/I99729588"]}],"countries":["IN"],"is_corresponding":true,"raw_author_name":"Abhinandan Panda","raw_affiliation_strings":["School of Electrical and Computer Sciences, IIT Bhubaneswar, Bhubaneswar, India"],"raw_orcid":"https://orcid.org/0000-0001-5469-7032","affiliations":[{"raw_affiliation_string":"School of Electrical and Computer Sciences, IIT Bhubaneswar, Bhubaneswar, India","institution_ids":["https://openalex.org/I99729588"]}]},{"author_position":"middle","author":{"id":"https://openalex.org/A5113382341","display_name":"Ayush Anand","orcid":null},"institutions":[{"id":"https://openalex.org/I99729588","display_name":"Indian Institute of Technology Bhubaneswar","ror":"https://ror.org/04gx72j20","country_code":"IN","type":"education","lineage":["https://openalex.org/I99729588"]}],"countries":["IN"],"is_corresponding":false,"raw_author_name":"Ayush Anand","raw_affiliation_strings":["School of Electrical and Computer Sciences, IIT Bhubaneswar, Bhubaneswar, India"],"raw_orcid":"https://orcid.org/0009-0009-3754-630X","affiliations":[{"raw_affiliation_string":"School of Electrical and Computer Sciences, IIT Bhubaneswar, Bhubaneswar, India","institution_ids":["https://openalex.org/I99729588"]}]},{"author_position":"middle","author":{"id":"https://openalex.org/A5035408678","display_name":"Srinivas Pinisetty","orcid":"https://orcid.org/0000-0001-7779-8231"},"institutions":[{"id":"https://openalex.org/I99729588","display_name":"Indian Institute of Technology Bhubaneswar","ror":"https://ror.org/04gx72j20","country_code":"IN","type":"education","lineage":["https://openalex.org/I99729588"]}],"countries":["IN"],"is_corresponding":false,"raw_author_name":"Srinivas Pinisetty","raw_affiliation_strings":["School of Electrical and Computer Sciences, IIT Bhubaneswar, Bhubaneswar, India"],"raw_orcid":"https://orcid.org/0000-0001-7779-8231","affiliations":[{"raw_affiliation_string":"School of Electrical and Computer Sciences, IIT Bhubaneswar, Bhubaneswar, India","institution_ids":["https://openalex.org/I99729588"]}]},{"author_position":"last","author":{"id":"https://openalex.org/A5076621370","display_name":"Partha S. Roop","orcid":"https://orcid.org/0000-0001-9654-5678"},"institutions":[{"id":"https://openalex.org/I154130895","display_name":"University of Auckland","ror":"https://ror.org/03b94tp07","country_code":"NZ","type":"education","lineage":["https://openalex.org/I154130895"]}],"countries":["NZ"],"is_corresponding":false,"raw_author_name":"Partha Roop","raw_affiliation_strings":["Department of Electrical, Computer and Software Engineering, University of Auckland, Auckland, New Zealand"],"raw_orcid":"https://orcid.org/0000-0001-9654-5678","affiliations":[{"raw_affiliation_string":"Department of Electrical, Computer and Software Engineering, University of Auckland, Auckland, New Zealand","institution_ids":["https://openalex.org/I154130895"]}]}],"institutions":[],"countries_distinct_count":2,"institutions_distinct_count":4,"corresponding_author_ids":["https://openalex.org/A5038571565"],"corresponding_institution_ids":["https://openalex.org/I99729588"],"apc_list":null,"apc_paid":null,"fwci":0.7653,"has_fulltext":false,"cited_by_count":2,"citation_normalized_percentile":{"value":0.77250545,"is_in_top_1_percent":false,"is_in_top_10_percent":false},"cited_by_percentile_year":{"min":95,"max":96},"biblio":{"volume":"16","issue":"4","first_page":"405","last_page":"408"},"is_retracted":false,"is_paratext":false,"is_xpac":false,"primary_topic":{"id":"https://openalex.org/T11021","display_name":"ECG Monitoring and Analysis","score":0.9093999862670898,"subfield":{"id":"https://openalex.org/subfields/2705","display_name":"Cardiology and Cardiovascular Medicine"},"field":{"id":"https://openalex.org/fields/27","display_name":"Medicine"},"domain":{"id":"https://openalex.org/domains/4","display_name":"Health Sciences"}},"topics":[{"id":"https://openalex.org/T11021","display_name":"ECG Monitoring and Analysis","score":0.9093999862670898,"subfield":{"id":"https://openalex.org/subfields/2705","display_name":"Cardiology and Cardiovascular Medicine"},"field":{"id":"https://openalex.org/fields/27","display_name":"Medicine"},"domain":{"id":"https://openalex.org/domains/4","display_name":"Health Sciences"}}],"keywords":[{"id":"https://openalex.org/keywords/computer-science","display_name":"Computer science","score":0.8183428049087524},{"id":"https://openalex.org/keywords/real-time-computing","display_name":"Real-time computing","score":0.3801313638687134},{"id":"https://openalex.org/keywords/embedded-system","display_name":"Embedded system","score":0.3782464563846588}],"concepts":[{"id":"https://openalex.org/C41008148","wikidata":"https://www.wikidata.org/wiki/Q21198","display_name":"Computer science","level":0,"score":0.8183428049087524},{"id":"https://openalex.org/C79403827","wikidata":"https://www.wikidata.org/wiki/Q3988","display_name":"Real-time computing","level":1,"score":0.3801313638687134},{"id":"https://openalex.org/C149635348","wikidata":"https://www.wikidata.org/wiki/Q193040","display_name":"Embedded system","level":1,"score":0.3782464563846588}],"mesh":[],"locations_count":1,"locations":[{"id":"doi:10.1109/les.2024.3443449","is_oa":false,"landing_page_url":"https://doi.org/10.1109/les.2024.3443449","pdf_url":null,"source":{"id":"https://openalex.org/S22443479","display_name":"IEEE Embedded Systems Letters","issn_l":"1943-0663","issn":["1943-0663","1943-0671"],"is_oa":false,"is_in_doaj":false,"is_core":true,"host_organization":"https://openalex.org/P4310319808","host_organization_name":"Institute of Electrical and Electronics Engineers","host_organization_lineage":["https://openalex.org/P4310319808"],"host_organization_lineage_names":["Institute of Electrical and Electronics Engineers"],"type":"journal"},"license":null,"license_id":null,"version":"publishedVersion","is_accepted":true,"is_published":true,"raw_source_name":"IEEE Embedded Systems Letters","raw_type":"journal-article"}],"best_oa_location":null,"sustainable_development_goals":[],"awards":[],"funders":[{"id":"https://openalex.org/F4320334771","display_name":"Science and Engineering Research Board","ror":"https://ror.org/03ffdsr55"}],"has_content":{"pdf":false,"grobid_xml":false},"content_urls":null,"referenced_works_count":31,"referenced_works":["https://openalex.org/W1964253939","https://openalex.org/W2027769154","https://openalex.org/W2087522345","https://openalex.org/W2101508170","https://openalex.org/W2101739008","https://openalex.org/W2125914602","https://openalex.org/W2162273778","https://openalex.org/W2167925220","https://openalex.org/W2294418644","https://openalex.org/W2431637923","https://openalex.org/W2731600756","https://openalex.org/W2758839352","https://openalex.org/W2783498497","https://openalex.org/W2784502443","https://openalex.org/W2823216385","https://openalex.org/W2898519551","https://openalex.org/W2904442697","https://openalex.org/W2930362209","https://openalex.org/W2965818712","https://openalex.org/W2979164675","https://openalex.org/W3000965547","https://openalex.org/W3012300836","https://openalex.org/W3029137193","https://openalex.org/W3030973653","https://openalex.org/W3127637041","https://openalex.org/W3159622029","https://openalex.org/W4200022079","https://openalex.org/W4230569261","https://openalex.org/W4288391446","https://openalex.org/W4293812255","https://openalex.org/W6605241255"],"related_works":["https://openalex.org/W4391375266","https://openalex.org/W2899084033","https://openalex.org/W2748952813","https://openalex.org/W2390279801","https://openalex.org/W4391913857","https://openalex.org/W2358668433","https://openalex.org/W4396701345","https://openalex.org/W2376932109","https://openalex.org/W2001405890","https://openalex.org/W4396696052"],"abstract_inverted_index":{"An":[0],"alarming":[1],"increase":[2],"in":[3,123],"hypertension":[4,24,91,120],"is":[5,33,99,111,131,145],"a":[6,84,115,128],"hazard":[7],"to":[8,113,118,133,155],"global":[9],"health":[10],"that":[11,36],"poses":[12],"severe":[13],"implications":[14],"for":[15,29,69,90],"the":[16,41,51,54,137,141,148],"body\u2019s":[17],"vital":[18],"organs.":[19],"To":[20],"prevent":[21],"serious":[22],"repercussions,":[23],"should":[25],"be":[26,156],"monitored":[27],"continuously":[28],"early":[30],"detection.":[31],"It":[32],"well":[34],"known":[35],"physiological":[37],"signals,":[38],"such":[39,73],"as":[40],"photoplethysmogram":[42],"(PPG)":[43],"and":[44,77,95,147,151,159],"electrocardiogram":[45],"(ECG),":[46],"carry":[47],"essential":[48],"information":[49],"about":[50],"vitals":[52],"of":[53],"human":[55],"body.":[56],"Considering":[57],"this,":[58],"numerous":[59],"machine":[60],"learning-based":[61],"models":[62,74],"based":[63,125],"on":[64,126],"ECG-PPG":[65],"have":[66],"been":[67],"proposed":[68,142],"monitoring":[70,92],"hypertension;":[71],"however,":[72],"are":[75,153],"\u201cnon-explainable\u201d":[76],"lack":[78],"clinical":[79],"interpretation.":[80],"This":[81],"work":[82],"proposes":[83],"formal":[85],"method-based":[86],"runtime":[87,129],"verification":[88],"approach":[89],"using":[93,108],"ECG":[94],"PPG":[96],"sensing,":[97],"which":[98,127],"explainable.":[100],"The":[101],"pulse":[102],"arrival":[103],"time":[104],"(PAT)":[105],"feature":[106],"extracted":[107],"both":[109],"signals":[110],"employed":[112],"implement":[114],"decision":[116],"tree":[117],"infer":[119],"patterns/policies":[121],"defined":[122],"PAT,":[124],"monitor":[130],"synthesized":[132],"classify":[134],"hypertension.":[135],"Using":[136],"MIMIC":[138],"II":[139],"dataset,":[140],"scheme\u2019s":[143],"performance":[144],"assessed,":[146],"accuracy,":[149],"sensitivity,":[150],"specificity":[152],"determined":[154],"95.7%,":[157],"93.9%,":[158],"97.6%,":[160],"respectively.":[161]},"counts_by_year":[{"year":2025,"cited_by_count":2}],"updated_date":"2026-03-27T05:58:40.876381","created_date":"2025-10-10T00:00:00"}
