{"id":"https://openalex.org/W2125136266","doi":"https://doi.org/10.1109/lcn.2009.5355099","title":"Improving uplink bandwidth management in 802.16 networks","display_name":"Improving uplink bandwidth management in 802.16 networks","publication_year":2009,"publication_date":"2009-10-01","ids":{"openalex":"https://openalex.org/W2125136266","doi":"https://doi.org/10.1109/lcn.2009.5355099","mag":"2125136266"},"language":"en","primary_location":{"id":"doi:10.1109/lcn.2009.5355099","is_oa":false,"landing_page_url":"https://doi.org/10.1109/lcn.2009.5355099","pdf_url":null,"source":null,"license":null,"license_id":null,"version":"publishedVersion","is_accepted":true,"is_published":true,"raw_source_name":"2009 IEEE 34th Conference on Local Computer Networks","raw_type":"proceedings-article"},"type":"conference-paper","indexed_in":["crossref"],"open_access":{"is_oa":false,"oa_status":"closed","oa_url":null,"any_repository_has_fulltext":false},"authorships":[{"author_position":"first","author":{"id":"https://openalex.org/A5111715497","display_name":"Andr\u00e9s Arcia","orcid":null},"institutions":[{"id":"https://openalex.org/I126425946","display_name":"Universit\u00e9 Europ\u00e9enne de Bretagne","ror":"https://ror.org/033c46s90","country_code":"FR","type":"education","lineage":["https://openalex.org/I126425946"]},{"id":"https://openalex.org/I203303854","display_name":"University of the Andes","ror":"https://ror.org/02h1b1x27","country_code":"VE","type":"education","lineage":["https://openalex.org/I203303854"]},{"id":"https://openalex.org/I205703379","display_name":"Institut Mines-T\u00e9l\u00e9com","ror":"https://ror.org/025vp2923","country_code":"FR","type":"facility","lineage":["https://openalex.org/I205703379"]}],"countries":["FR","VE"],"is_corresponding":false,"raw_author_name":"Andres Arcia","raw_affiliation_strings":["Institut Telecom Telecom Bretagne, Universit\u00f3 Europ\u00e9enne de Bretagne, Cesson-Sevigne, France","Universidad de Los Andes, Merida, Venezuela"],"raw_orcid":null,"affiliations":[{"raw_affiliation_string":"Institut Telecom Telecom Bretagne, Universit\u00f3 Europ\u00e9enne de Bretagne, Cesson-Sevigne, France","institution_ids":["https://openalex.org/I126425946","https://openalex.org/I205703379"]},{"raw_affiliation_string":"Universidad de Los Andes, Merida, Venezuela","institution_ids":["https://openalex.org/I203303854"]}]},{"author_position":"middle","author":{"id":"https://openalex.org/A5110751221","display_name":"Nicolas Montavont","orcid":null},"institutions":[{"id":"https://openalex.org/I126425946","display_name":"Universit\u00e9 Europ\u00e9enne de Bretagne","ror":"https://ror.org/033c46s90","country_code":"FR","type":"education","lineage":["https://openalex.org/I126425946"]},{"id":"https://openalex.org/I205703379","display_name":"Institut Mines-T\u00e9l\u00e9com","ror":"https://ror.org/025vp2923","country_code":"FR","type":"facility","lineage":["https://openalex.org/I205703379"]}],"countries":["FR"],"is_corresponding":false,"raw_author_name":"Nicolas Montavont","raw_affiliation_strings":["Institut Telecom Telecom Bretagne, Universit\u00f3 Europ\u00e9enne de Bretagne, Cesson-Sevigne, France"],"raw_orcid":null,"affiliations":[{"raw_affiliation_string":"Institut Telecom Telecom Bretagne, Universit\u00f3 Europ\u00e9enne de Bretagne, Cesson-Sevigne, France","institution_ids":["https://openalex.org/I126425946","https://openalex.org/I205703379"]}]},{"author_position":"middle","author":{"id":"https://openalex.org/A5063585198","display_name":"Alejandro Paltrineri","orcid":null},"institutions":[{"id":"https://openalex.org/I126425946","display_name":"Universit\u00e9 Europ\u00e9enne de Bretagne","ror":"https://ror.org/033c46s90","country_code":"FR","type":"education","lineage":["https://openalex.org/I126425946"]},{"id":"https://openalex.org/I203303854","display_name":"University of the Andes","ror":"https://ror.org/02h1b1x27","country_code":"VE","type":"education","lineage":["https://openalex.org/I203303854"]},{"id":"https://openalex.org/I205703379","display_name":"Institut Mines-T\u00e9l\u00e9com","ror":"https://ror.org/025vp2923","country_code":"FR","type":"facility","lineage":["https://openalex.org/I205703379"]}],"countries":["FR","VE"],"is_corresponding":false,"raw_author_name":"Alejandro Paltrineri","raw_affiliation_strings":["Institut Telecom Telecom Bretagne, Universit\u00f3 Europ\u00e9enne de Bretagne, Cesson-Sevigne, France","Universidad de Los Andes, Merida, Venezuela"],"raw_orcid":null,"affiliations":[{"raw_affiliation_string":"Institut Telecom Telecom Bretagne, Universit\u00f3 Europ\u00e9enne de Bretagne, Cesson-Sevigne, France","institution_ids":["https://openalex.org/I126425946","https://openalex.org/I205703379"]},{"raw_affiliation_string":"Universidad de Los Andes, Merida, Venezuela","institution_ids":["https://openalex.org/I203303854"]}]},{"author_position":"last","author":{"id":"https://openalex.org/A5066296854","display_name":"David Ros","orcid":"https://orcid.org/0000-0002-6121-3494"},"institutions":[{"id":"https://openalex.org/I126425946","display_name":"Universit\u00e9 Europ\u00e9enne de Bretagne","ror":"https://ror.org/033c46s90","country_code":"FR","type":"education","lineage":["https://openalex.org/I126425946"]},{"id":"https://openalex.org/I205703379","display_name":"Institut Mines-T\u00e9l\u00e9com","ror":"https://ror.org/025vp2923","country_code":"FR","type":"facility","lineage":["https://openalex.org/I205703379"]}],"countries":["FR"],"is_corresponding":false,"raw_author_name":"David Ros","raw_affiliation_strings":["Institut Telecom Telecom Bretagne, Universit\u00f3 Europ\u00e9enne de Bretagne, Cesson-Sevigne, France"],"raw_orcid":null,"affiliations":[{"raw_affiliation_string":"Institut Telecom Telecom Bretagne, Universit\u00f3 Europ\u00e9enne de Bretagne, Cesson-Sevigne, France","institution_ids":["https://openalex.org/I126425946","https://openalex.org/I205703379"]}]}],"institutions":[],"countries_distinct_count":2,"institutions_distinct_count":3,"corresponding_author_ids":[],"corresponding_institution_ids":[],"apc_list":null,"apc_paid":null,"fwci":1.4506,"has_fulltext":false,"cited_by_count":3,"citation_normalized_percentile":{"value":0.80007959,"is_in_top_1_percent":false,"is_in_top_10_percent":false},"cited_by_percentile_year":{"min":89,"max":94},"biblio":{"volume":"6","issue":null,"first_page":"233","last_page":"236"},"is_retracted":false,"is_paratext":false,"is_xpac":false,"primary_topic":{"id":"https://openalex.org/T11409","display_name":"Advanced Wireless Network Optimization","score":0.9998999834060669,"subfield":{"id":"https://openalex.org/subfields/2208","display_name":"Electrical and Electronic Engineering"},"field":{"id":"https://openalex.org/fields/22","display_name":"Engineering"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}},"topics":[{"id":"https://openalex.org/T11409","display_name":"Advanced Wireless Network Optimization","score":0.9998999834060669,"subfield":{"id":"https://openalex.org/subfields/2208","display_name":"Electrical and Electronic Engineering"},"field":{"id":"https://openalex.org/fields/22","display_name":"Engineering"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}},{"id":"https://openalex.org/T10138","display_name":"Network Traffic and Congestion Control","score":0.9958000183105469,"subfield":{"id":"https://openalex.org/subfields/1705","display_name":"Computer Networks and Communications"},"field":{"id":"https://openalex.org/fields/17","display_name":"Computer Science"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}},{"id":"https://openalex.org/T10575","display_name":"Wireless Communication Networks Research","score":0.9930999875068665,"subfield":{"id":"https://openalex.org/subfields/1705","display_name":"Computer Networks and Communications"},"field":{"id":"https://openalex.org/fields/17","display_name":"Computer Science"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}}],"keywords":[{"id":"https://openalex.org/keywords/computer-network","display_name":"Computer network","score":0.797847330570221},{"id":"https://openalex.org/keywords/dynamic-bandwidth-allocation","display_name":"Dynamic bandwidth allocation","score":0.7544339895248413},{"id":"https://openalex.org/keywords/telecommunications-link","display_name":"Telecommunications link","score":0.686282753944397},{"id":"https://openalex.org/keywords/computer-science","display_name":"Computer science","score":0.6827406883239746},{"id":"https://openalex.org/keywords/bandwidth-allocation","display_name":"Bandwidth allocation","score":0.6786385774612427},{"id":"https://openalex.org/keywords/bandwidth","display_name":"Bandwidth (computing)","score":0.6731383800506592},{"id":"https://openalex.org/keywords/bandwidth-management","display_name":"Bandwidth management","score":0.6136817932128906},{"id":"https://openalex.org/keywords/base-station","display_name":"Base station","score":0.5938933491706848},{"id":"https://openalex.org/keywords/throughput","display_name":"Throughput","score":0.45726168155670166},{"id":"https://openalex.org/keywords/scheduling","display_name":"Scheduling (production processes)","score":0.4433874189853668},{"id":"https://openalex.org/keywords/telecommunications","display_name":"Telecommunications","score":0.31421536207199097},{"id":"https://openalex.org/keywords/wireless","display_name":"Wireless","score":0.16657620668411255},{"id":"https://openalex.org/keywords/engineering","display_name":"Engineering","score":0.15147268772125244}],"concepts":[{"id":"https://openalex.org/C31258907","wikidata":"https://www.wikidata.org/wiki/Q1301371","display_name":"Computer network","level":1,"score":0.797847330570221},{"id":"https://openalex.org/C145062175","wikidata":"https://www.wikidata.org/wiki/Q5318947","display_name":"Dynamic bandwidth allocation","level":3,"score":0.7544339895248413},{"id":"https://openalex.org/C138660444","wikidata":"https://www.wikidata.org/wiki/Q5607897","display_name":"Telecommunications link","level":2,"score":0.686282753944397},{"id":"https://openalex.org/C41008148","wikidata":"https://www.wikidata.org/wiki/Q21198","display_name":"Computer science","level":0,"score":0.6827406883239746},{"id":"https://openalex.org/C200157131","wikidata":"https://www.wikidata.org/wiki/Q4854763","display_name":"Bandwidth allocation","level":3,"score":0.6786385774612427},{"id":"https://openalex.org/C2776257435","wikidata":"https://www.wikidata.org/wiki/Q1576430","display_name":"Bandwidth (computing)","level":2,"score":0.6731383800506592},{"id":"https://openalex.org/C59538626","wikidata":"https://www.wikidata.org/wiki/Q4854768","display_name":"Bandwidth management","level":3,"score":0.6136817932128906},{"id":"https://openalex.org/C68649174","wikidata":"https://www.wikidata.org/wiki/Q1379116","display_name":"Base station","level":2,"score":0.5938933491706848},{"id":"https://openalex.org/C157764524","wikidata":"https://www.wikidata.org/wiki/Q1383412","display_name":"Throughput","level":3,"score":0.45726168155670166},{"id":"https://openalex.org/C206729178","wikidata":"https://www.wikidata.org/wiki/Q2271896","display_name":"Scheduling (production processes)","level":2,"score":0.4433874189853668},{"id":"https://openalex.org/C76155785","wikidata":"https://www.wikidata.org/wiki/Q418","display_name":"Telecommunications","level":1,"score":0.31421536207199097},{"id":"https://openalex.org/C555944384","wikidata":"https://www.wikidata.org/wiki/Q249","display_name":"Wireless","level":2,"score":0.16657620668411255},{"id":"https://openalex.org/C127413603","wikidata":"https://www.wikidata.org/wiki/Q11023","display_name":"Engineering","level":0,"score":0.15147268772125244},{"id":"https://openalex.org/C21547014","wikidata":"https://www.wikidata.org/wiki/Q1423657","display_name":"Operations management","level":1,"score":0.0}],"mesh":[],"locations_count":2,"locations":[{"id":"doi:10.1109/lcn.2009.5355099","is_oa":false,"landing_page_url":"https://doi.org/10.1109/lcn.2009.5355099","pdf_url":null,"source":null,"license":null,"license_id":null,"version":"publishedVersion","is_accepted":true,"is_published":true,"raw_source_name":"2009 IEEE 34th Conference on Local Computer Networks","raw_type":"proceedings-article"},{"id":"pmh:oai:HAL:hal-02865056v1","is_oa":false,"landing_page_url":"https://hal.science/hal-02865056","pdf_url":null,"source":{"id":"https://openalex.org/S4306402512","display_name":"HAL (Le Centre pour la Communication Scientifique Directe)","issn_l":null,"issn":null,"is_oa":false,"is_in_doaj":false,"is_core":false,"host_organization":"https://openalex.org/I1294671590","host_organization_name":"Centre National de la Recherche Scientifique","host_organization_lineage":["https://openalex.org/I1294671590"],"host_organization_lineage_names":[],"type":"repository"},"license":null,"license_id":null,"version":"submittedVersion","is_accepted":false,"is_published":false,"raw_source_name":"34th IEEE Conference on Local Computer Networks (LCN), Oct 2009, Z\u00fcrich, Switzerland. pp.233 - 236, &#x27E8;10.1109/LCN.2009.5355099&#x27E9;","raw_type":"info:eu-repo/semantics/conferenceObject"}],"best_oa_location":null,"sustainable_development_goals":[{"id":"https://metadata.un.org/sdg/17","score":0.4300000071525574,"display_name":"Partnerships for the goals"}],"awards":[],"funders":[],"has_content":{"pdf":false,"grobid_xml":false},"content_urls":null,"referenced_works_count":8,"referenced_works":["https://openalex.org/W644664656","https://openalex.org/W1502809863","https://openalex.org/W2133454427","https://openalex.org/W2161227934","https://openalex.org/W2161666269","https://openalex.org/W2766739561","https://openalex.org/W6630224622","https://openalex.org/W6679624966"],"related_works":["https://openalex.org/W1686653828","https://openalex.org/W2205120236","https://openalex.org/W1480067644","https://openalex.org/W2009864528","https://openalex.org/W2379573725","https://openalex.org/W2167294866","https://openalex.org/W2350829955","https://openalex.org/W2102578690","https://openalex.org/W2134506128","https://openalex.org/W2586950296"],"abstract_inverted_index":{"In":[0,46],"802.16":[1],"networks,":[2],"bandwidth":[3,10,19,29,56,69,79,89],"request-grant":[4],"mechanisms":[5],"allow":[6],"managing":[7],"the":[8,22,28,37,41,61,64,72,78,84,95,106,113],"uplink":[9,44],"needs":[11,70],"of":[12,27,43,54,63,66,97,109],"subscriber":[13,67],"stations.":[14],"Subscriber":[15],"stations":[16],"send":[17],"their":[18],"requests":[20,90],"to":[21,60,87],"base":[23,38,73],"station,":[24],"where":[25],"most":[26],"scheduling":[30],"is":[31],"centralized.":[32],"After":[33],"processing":[34],"such":[35,110],"requests,":[36],"station":[39],"schedules":[40],"transmission":[42],"traffic.":[45],"this":[47],"paper":[48],"we":[49,102],"present":[50],"a":[51],"preliminary":[52],"investigation":[53],"some":[55],"allocation":[57],"issues,":[58],"related":[59],"management":[62],"perception":[65,80],"stations'":[68],"at":[71],"station.":[74],"We":[75],"illustrate":[76],"how":[77],"varies":[81],"depending":[82],"on":[83,94,112],"policy":[85],"used":[86],"manage":[88],"and":[91],"grants.":[92],"Focusing":[93],"case":[96],"TCP":[98],"Best":[99],"Effort":[100],"traffic,":[101],"assess":[103],"by":[104],"simulation":[105],"potential":[107],"impact":[108],"policies":[111],"system's":[114],"aggregate":[115],"throughput.":[116]},"counts_by_year":[{"year":2012,"cited_by_count":1}],"updated_date":"2026-08-26T07:47:46.906454","created_date":"2025-10-10T00:00:00"}
