{"id":"https://openalex.org/W2168575745","doi":"https://doi.org/10.1109/latw.2011.5985907","title":"Test and calibration of MEMS convective accelerometers with a fully electrical setup","display_name":"Test and calibration of MEMS convective accelerometers with a fully electrical setup","publication_year":2011,"publication_date":"2011-03-01","ids":{"openalex":"https://openalex.org/W2168575745","doi":"https://doi.org/10.1109/latw.2011.5985907","mag":"2168575745"},"language":"en","primary_location":{"id":"doi:10.1109/latw.2011.5985907","is_oa":false,"landing_page_url":"https://doi.org/10.1109/latw.2011.5985907","pdf_url":null,"source":null,"license":null,"license_id":null,"version":"publishedVersion","is_accepted":true,"is_published":true,"raw_source_name":"2011 12th Latin American Test Workshop (LATW)","raw_type":"proceedings-article"},"type":"article","indexed_in":["crossref"],"open_access":{"is_oa":false,"oa_status":"closed","oa_url":null,"any_repository_has_fulltext":false},"authorships":[{"author_position":"first","author":{"id":"https://openalex.org/A5039655931","display_name":"Amira Rekik","orcid":"https://orcid.org/0000-0001-6029-7203"},"institutions":[{"id":"https://openalex.org/I19894307","display_name":"Universit\u00e9 de Montpellier","ror":"https://ror.org/051escj72","country_code":"FR","type":"education","lineage":["https://openalex.org/I19894307"]},{"id":"https://openalex.org/I2802056588","display_name":"COMUE Languedoc-Roussillon Universit\u00e9s","ror":"https://ror.org/04f6hmf16","country_code":"FR","type":"other","lineage":["https://openalex.org/I2802056588"]}],"countries":["FR"],"is_corresponding":true,"raw_author_name":"A. A. Rekik","raw_affiliation_strings":["Universite de Montpellier, Montpellier, Languedoc-Roussillon, FR"],"affiliations":[{"raw_affiliation_string":"Universite de Montpellier, Montpellier, Languedoc-Roussillon, FR","institution_ids":["https://openalex.org/I2802056588","https://openalex.org/I19894307"]}]},{"author_position":"middle","author":{"id":"https://openalex.org/A5040698879","display_name":"F. Aza\u0131\u0308s","orcid":"https://orcid.org/0000-0001-6458-5018"},"institutions":[{"id":"https://openalex.org/I1294671590","display_name":"Centre National de la Recherche Scientifique","ror":"https://ror.org/02feahw73","country_code":"FR","type":"funder","lineage":["https://openalex.org/I1294671590"]},{"id":"https://openalex.org/I4210101743","display_name":"Laboratoire d'Informatique, de Robotique et de Micro\u00e9lectronique de Montpellier","ror":"https://ror.org/013yean28","country_code":"FR","type":"facility","lineage":["https://openalex.org/I1294671590","https://openalex.org/I1294671590","https://openalex.org/I1326498283","https://openalex.org/I151295451","https://openalex.org/I19894307","https://openalex.org/I4210101743","https://openalex.org/I4210159245","https://openalex.org/I4412460525"]},{"id":"https://openalex.org/I19894307","display_name":"Universit\u00e9 de Montpellier","ror":"https://ror.org/051escj72","country_code":"FR","type":"education","lineage":["https://openalex.org/I19894307"]}],"countries":["FR"],"is_corresponding":false,"raw_author_name":"F. Azais","raw_affiliation_strings":["LIRMM, CNRS, University of Montpellier 2, Montpellier, France"],"affiliations":[{"raw_affiliation_string":"LIRMM, CNRS, University of Montpellier 2, Montpellier, France","institution_ids":["https://openalex.org/I19894307","https://openalex.org/I4210101743","https://openalex.org/I1294671590"]}]},{"author_position":"middle","author":{"id":"https://openalex.org/A5012205140","display_name":"Norbert Dumas","orcid":null},"institutions":[{"id":"https://openalex.org/I19894307","display_name":"Universit\u00e9 de Montpellier","ror":"https://ror.org/051escj72","country_code":"FR","type":"education","lineage":["https://openalex.org/I19894307"]},{"id":"https://openalex.org/I4210101743","display_name":"Laboratoire d'Informatique, de Robotique et de Micro\u00e9lectronique de Montpellier","ror":"https://ror.org/013yean28","country_code":"FR","type":"facility","lineage":["https://openalex.org/I1294671590","https://openalex.org/I1294671590","https://openalex.org/I1326498283","https://openalex.org/I151295451","https://openalex.org/I19894307","https://openalex.org/I4210101743","https://openalex.org/I4210159245","https://openalex.org/I4412460525"]},{"id":"https://openalex.org/I1294671590","display_name":"Centre National de la Recherche Scientifique","ror":"https://ror.org/02feahw73","country_code":"FR","type":"funder","lineage":["https://openalex.org/I1294671590"]}],"countries":["FR"],"is_corresponding":false,"raw_author_name":"N. Dumas","raw_affiliation_strings":["LIRMM, CNRS, University of Montpellier 2, Montpellier, France"],"affiliations":[{"raw_affiliation_string":"LIRMM, CNRS, University of Montpellier 2, Montpellier, France","institution_ids":["https://openalex.org/I19894307","https://openalex.org/I4210101743","https://openalex.org/I1294671590"]}]},{"author_position":"middle","author":{"id":"https://openalex.org/A5003132918","display_name":"F. Mailly","orcid":"https://orcid.org/0000-0002-4030-0505"},"institutions":[{"id":"https://openalex.org/I19894307","display_name":"Universit\u00e9 de Montpellier","ror":"https://ror.org/051escj72","country_code":"FR","type":"education","lineage":["https://openalex.org/I19894307"]},{"id":"https://openalex.org/I4210101743","display_name":"Laboratoire d'Informatique, de Robotique et de Micro\u00e9lectronique de Montpellier","ror":"https://ror.org/013yean28","country_code":"FR","type":"facility","lineage":["https://openalex.org/I1294671590","https://openalex.org/I1294671590","https://openalex.org/I1326498283","https://openalex.org/I151295451","https://openalex.org/I19894307","https://openalex.org/I4210101743","https://openalex.org/I4210159245","https://openalex.org/I4412460525"]},{"id":"https://openalex.org/I1294671590","display_name":"Centre National de la Recherche Scientifique","ror":"https://ror.org/02feahw73","country_code":"FR","type":"funder","lineage":["https://openalex.org/I1294671590"]}],"countries":["FR"],"is_corresponding":false,"raw_author_name":"F. Mailly","raw_affiliation_strings":["LIRMM, CNRS, University of Montpellier 2, Montpellier, France"],"affiliations":[{"raw_affiliation_string":"LIRMM, CNRS, University of Montpellier 2, Montpellier, France","institution_ids":["https://openalex.org/I19894307","https://openalex.org/I4210101743","https://openalex.org/I1294671590"]}]},{"author_position":"last","author":{"id":"https://openalex.org/A5054580128","display_name":"Pascal Nouet","orcid":"https://orcid.org/0000-0003-2137-2623"},"institutions":[{"id":"https://openalex.org/I4210101743","display_name":"Laboratoire d'Informatique, de Robotique et de Micro\u00e9lectronique de Montpellier","ror":"https://ror.org/013yean28","country_code":"FR","type":"facility","lineage":["https://openalex.org/I1294671590","https://openalex.org/I1294671590","https://openalex.org/I1326498283","https://openalex.org/I151295451","https://openalex.org/I19894307","https://openalex.org/I4210101743","https://openalex.org/I4210159245","https://openalex.org/I4412460525"]},{"id":"https://openalex.org/I19894307","display_name":"Universit\u00e9 de Montpellier","ror":"https://ror.org/051escj72","country_code":"FR","type":"education","lineage":["https://openalex.org/I19894307"]},{"id":"https://openalex.org/I1294671590","display_name":"Centre National de la Recherche Scientifique","ror":"https://ror.org/02feahw73","country_code":"FR","type":"funder","lineage":["https://openalex.org/I1294671590"]}],"countries":["FR"],"is_corresponding":false,"raw_author_name":"P. Nouet","raw_affiliation_strings":["LIRMM, CNRS, University of Montpellier 2, Montpellier, France"],"affiliations":[{"raw_affiliation_string":"LIRMM, CNRS, University of Montpellier 2, Montpellier, France","institution_ids":["https://openalex.org/I19894307","https://openalex.org/I4210101743","https://openalex.org/I1294671590"]}]}],"institutions":[],"countries_distinct_count":1,"institutions_distinct_count":5,"corresponding_author_ids":["https://openalex.org/A5039655931"],"corresponding_institution_ids":["https://openalex.org/I19894307","https://openalex.org/I2802056588"],"apc_list":null,"apc_paid":null,"fwci":0.265,"has_fulltext":false,"cited_by_count":2,"citation_normalized_percentile":{"value":0.64664657,"is_in_top_1_percent":false,"is_in_top_10_percent":false},"cited_by_percentile_year":{"min":89,"max":94},"biblio":{"volume":"142","issue":null,"first_page":"1","last_page":"6"},"is_retracted":false,"is_paratext":false,"is_xpac":false,"primary_topic":{"id":"https://openalex.org/T10369","display_name":"Advanced MEMS and NEMS Technologies","score":1.0,"subfield":{"id":"https://openalex.org/subfields/2208","display_name":"Electrical and Electronic Engineering"},"field":{"id":"https://openalex.org/fields/22","display_name":"Engineering"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}},"topics":[{"id":"https://openalex.org/T10369","display_name":"Advanced MEMS and NEMS Technologies","score":1.0,"subfield":{"id":"https://openalex.org/subfields/2208","display_name":"Electrical and Electronic Engineering"},"field":{"id":"https://openalex.org/fields/22","display_name":"Engineering"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}},{"id":"https://openalex.org/T13928","display_name":"Advanced Sensor Technologies Research","score":0.9994000196456909,"subfield":{"id":"https://openalex.org/subfields/2204","display_name":"Biomedical Engineering"},"field":{"id":"https://openalex.org/fields/22","display_name":"Engineering"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}},{"id":"https://openalex.org/T11160","display_name":"Acoustic Wave Resonator Technologies","score":0.9983000159263611,"subfield":{"id":"https://openalex.org/subfields/2204","display_name":"Biomedical Engineering"},"field":{"id":"https://openalex.org/fields/22","display_name":"Engineering"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}}],"keywords":[{"id":"https://openalex.org/keywords/calibration","display_name":"Calibration","score":0.8263245820999146},{"id":"https://openalex.org/keywords/accelerometer","display_name":"Accelerometer","score":0.7954075932502747},{"id":"https://openalex.org/keywords/microelectromechanical-systems","display_name":"Microelectromechanical systems","score":0.7848739624023438},{"id":"https://openalex.org/keywords/sensitivity","display_name":"Sensitivity (control systems)","score":0.5845590829849243},{"id":"https://openalex.org/keywords/electronic-engineering","display_name":"Electronic engineering","score":0.5423724055290222},{"id":"https://openalex.org/keywords/test-bench","display_name":"Test bench","score":0.49627143144607544},{"id":"https://openalex.org/keywords/monte-carlo-method","display_name":"Monte Carlo method","score":0.4955085515975952},{"id":"https://openalex.org/keywords/bottleneck","display_name":"Bottleneck","score":0.48528382182121277},{"id":"https://openalex.org/keywords/computer-science","display_name":"Computer science","score":0.4793608784675598},{"id":"https://openalex.org/keywords/electrical-impedance","display_name":"Electrical impedance","score":0.46027514338493347},{"id":"https://openalex.org/keywords/materials-science","display_name":"Materials science","score":0.2802213132381439},{"id":"https://openalex.org/keywords/engineering","display_name":"Engineering","score":0.265840083360672},{"id":"https://openalex.org/keywords/electrical-engineering","display_name":"Electrical engineering","score":0.25927895307540894},{"id":"https://openalex.org/keywords/physics","display_name":"Physics","score":0.13307419419288635},{"id":"https://openalex.org/keywords/optoelectronics","display_name":"Optoelectronics","score":0.09776079654693604},{"id":"https://openalex.org/keywords/embedded-system","display_name":"Embedded system","score":0.09583467245101929}],"concepts":[{"id":"https://openalex.org/C165838908","wikidata":"https://www.wikidata.org/wiki/Q736777","display_name":"Calibration","level":2,"score":0.8263245820999146},{"id":"https://openalex.org/C89805583","wikidata":"https://www.wikidata.org/wiki/Q192940","display_name":"Accelerometer","level":2,"score":0.7954075932502747},{"id":"https://openalex.org/C37977207","wikidata":"https://www.wikidata.org/wiki/Q175561","display_name":"Microelectromechanical systems","level":2,"score":0.7848739624023438},{"id":"https://openalex.org/C21200559","wikidata":"https://www.wikidata.org/wiki/Q7451068","display_name":"Sensitivity (control systems)","level":2,"score":0.5845590829849243},{"id":"https://openalex.org/C24326235","wikidata":"https://www.wikidata.org/wiki/Q126095","display_name":"Electronic engineering","level":1,"score":0.5423724055290222},{"id":"https://openalex.org/C2776266606","wikidata":"https://www.wikidata.org/wiki/Q476482","display_name":"Test bench","level":2,"score":0.49627143144607544},{"id":"https://openalex.org/C19499675","wikidata":"https://www.wikidata.org/wiki/Q232207","display_name":"Monte Carlo method","level":2,"score":0.4955085515975952},{"id":"https://openalex.org/C2780513914","wikidata":"https://www.wikidata.org/wiki/Q18210350","display_name":"Bottleneck","level":2,"score":0.48528382182121277},{"id":"https://openalex.org/C41008148","wikidata":"https://www.wikidata.org/wiki/Q21198","display_name":"Computer science","level":0,"score":0.4793608784675598},{"id":"https://openalex.org/C17829176","wikidata":"https://www.wikidata.org/wiki/Q179043","display_name":"Electrical impedance","level":2,"score":0.46027514338493347},{"id":"https://openalex.org/C192562407","wikidata":"https://www.wikidata.org/wiki/Q228736","display_name":"Materials science","level":0,"score":0.2802213132381439},{"id":"https://openalex.org/C127413603","wikidata":"https://www.wikidata.org/wiki/Q11023","display_name":"Engineering","level":0,"score":0.265840083360672},{"id":"https://openalex.org/C119599485","wikidata":"https://www.wikidata.org/wiki/Q43035","display_name":"Electrical engineering","level":1,"score":0.25927895307540894},{"id":"https://openalex.org/C121332964","wikidata":"https://www.wikidata.org/wiki/Q413","display_name":"Physics","level":0,"score":0.13307419419288635},{"id":"https://openalex.org/C49040817","wikidata":"https://www.wikidata.org/wiki/Q193091","display_name":"Optoelectronics","level":1,"score":0.09776079654693604},{"id":"https://openalex.org/C149635348","wikidata":"https://www.wikidata.org/wiki/Q193040","display_name":"Embedded system","level":1,"score":0.09583467245101929},{"id":"https://openalex.org/C105795698","wikidata":"https://www.wikidata.org/wiki/Q12483","display_name":"Statistics","level":1,"score":0.0},{"id":"https://openalex.org/C111919701","wikidata":"https://www.wikidata.org/wiki/Q9135","display_name":"Operating system","level":1,"score":0.0},{"id":"https://openalex.org/C33923547","wikidata":"https://www.wikidata.org/wiki/Q395","display_name":"Mathematics","level":0,"score":0.0},{"id":"https://openalex.org/C62520636","wikidata":"https://www.wikidata.org/wiki/Q944","display_name":"Quantum mechanics","level":1,"score":0.0}],"mesh":[],"locations_count":2,"locations":[{"id":"doi:10.1109/latw.2011.5985907","is_oa":false,"landing_page_url":"https://doi.org/10.1109/latw.2011.5985907","pdf_url":null,"source":null,"license":null,"license_id":null,"version":"publishedVersion","is_accepted":true,"is_published":true,"raw_source_name":"2011 12th Latin American Test Workshop (LATW)","raw_type":"proceedings-article"},{"id":"pmh:oai:HAL:lirmm-00702769v1","is_oa":false,"landing_page_url":"https://hal-lirmm.ccsd.cnrs.fr/lirmm-00702769","pdf_url":null,"source":{"id":"https://openalex.org/S4306402512","display_name":"HAL (Le Centre pour la Communication Scientifique Directe)","issn_l":null,"issn":null,"is_oa":false,"is_in_doaj":false,"is_core":false,"host_organization":"https://openalex.org/I1294671590","host_organization_name":"Centre National de la Recherche Scientifique","host_organization_lineage":["https://openalex.org/I1294671590"],"host_organization_lineage_names":[],"type":"repository"},"license":null,"license_id":null,"version":"submittedVersion","is_accepted":false,"is_published":false,"raw_source_name":"http://www.feng.pucrs.br/~sisc/LATW/2011.html/","raw_type":"Conference papers"}],"best_oa_location":null,"sustainable_development_goals":[{"score":0.6000000238418579,"id":"https://metadata.un.org/sdg/7","display_name":"Affordable and clean energy"}],"awards":[],"funders":[],"has_content":{"grobid_xml":false,"pdf":false},"content_urls":null,"referenced_works_count":14,"referenced_works":["https://openalex.org/W1562570568","https://openalex.org/W1583828394","https://openalex.org/W1965118102","https://openalex.org/W1965494828","https://openalex.org/W1993525028","https://openalex.org/W1993880988","https://openalex.org/W2040073361","https://openalex.org/W2100197815","https://openalex.org/W2117487644","https://openalex.org/W2151698398","https://openalex.org/W2276575750","https://openalex.org/W2540088842","https://openalex.org/W6682440801","https://openalex.org/W6694990122"],"related_works":["https://openalex.org/W2595172197","https://openalex.org/W2084856301","https://openalex.org/W2127970246","https://openalex.org/W2885125400","https://openalex.org/W1001352512","https://openalex.org/W1989889224","https://openalex.org/W4382618745","https://openalex.org/W3161496874","https://openalex.org/W2026330382","https://openalex.org/W2915680872"],"abstract_inverted_index":{"MEMS":[0,46,62],"devices":[1],"are":[2,35],"expected":[3,130],"to":[4,27,39,104],"be":[5,129],"used":[6],"in":[7],"a":[8,37,111,119,121],"growing":[9],"number":[10],"of":[11,23,45,61,99,108,124],"high-volume":[12],"and":[13,32,57,77,93],"low-cost":[14,132],"applications.":[15],"However":[16],"because":[17],"they":[18],"typically":[19],"requires":[20],"the":[21,41,59,97,100,106,139],"application":[22],"physical":[24],"test":[25,31],"stimuli":[26],"verify":[28],"their":[29],"specifications,":[30],"calibration":[33,140],"costs":[34],"actually":[36],"bottleneck":[38],"reduce":[40,105],"overall":[42],"production":[43,122],"cost":[44],"sensor.":[47],"This":[48],"paper":[49],"presents":[50],"an":[51],"alternative":[52],"electrical-only":[53],"solution":[54],"for":[55,131,138],"testing":[56],"calibrating":[58],"sensitivity":[60,109],"convective":[63],"accelerometers.":[64],"It":[65],"is":[66,84],"based":[67],"on":[68],"simple":[69],"impedance":[70],"measurements":[71,137],"performed":[72],"both":[73],"at":[74],"ambient":[75],"temperature":[76],"under":[78],"nominal":[79],"biasing":[80],"conditions.":[81],"The":[82],"method":[83],"evaluated":[85],"through":[86],"Monte-Carlo":[87],"simulations":[88],"considering":[89],"typical":[90],"process":[91],"fluctuations":[92],"mismatch.":[94],"Results":[95],"show":[96],"potentialities":[98],"technique":[101],"that":[102],"permits":[103],"dispersion":[107],"by":[110],"factor":[112],"higher":[113],"than":[114,126],"11":[115],"after":[116],"calibration.":[117],"As":[118],"consequence,":[120],"yield":[123],"more":[125],"99.8%":[127],"can":[128],"products":[133],"using":[134],"only":[135],"electrical":[136],"scheme.":[141]},"counts_by_year":[{"year":2017,"cited_by_count":1},{"year":2013,"cited_by_count":1}],"updated_date":"2025-11-06T03:46:38.306776","created_date":"2025-10-10T00:00:00"}
