{"id":"https://openalex.org/W7147167268","doi":"https://doi.org/10.1109/lascas67804.2026.11457094","title":"Development of a Low-Cost Passive and Active Leg Rehabilitation Device with an Interactive Interface and IoT Capabilities","display_name":"Development of a Low-Cost Passive and Active Leg Rehabilitation Device with an Interactive Interface and IoT Capabilities","publication_year":2026,"publication_date":"2026-02-24","ids":{"openalex":"https://openalex.org/W7147167268","doi":"https://doi.org/10.1109/lascas67804.2026.11457094"},"language":null,"primary_location":{"id":"doi:10.1109/lascas67804.2026.11457094","is_oa":false,"landing_page_url":"https://doi.org/10.1109/lascas67804.2026.11457094","pdf_url":null,"source":null,"license":null,"license_id":null,"version":"publishedVersion","is_accepted":true,"is_published":true,"raw_source_name":"2026 IEEE 17th Latin America Symposium on Circuits and System (LASCAS)","raw_type":"proceedings-article"},"type":"article","indexed_in":["crossref"],"open_access":{"is_oa":false,"oa_status":"closed","oa_url":null,"any_repository_has_fulltext":false},"authorships":[{"author_position":"first","author":{"id":"https://openalex.org/A5132606435","display_name":"Johan Campos-Cerdas","orcid":null},"institutions":[{"id":"https://openalex.org/I145372079","display_name":"Instituto Tecnol\u00f3gico de Costa Rica","ror":"https://ror.org/04zhrfn38","country_code":"CR","type":"education","lineage":["https://openalex.org/I145372079"]}],"countries":["CR"],"is_corresponding":true,"raw_author_name":"Johan Campos-Cerdas","raw_affiliation_strings":["Instituto Tecnol&#x00F3;gico de Costa Rica,Mechatronics Engineering,Cartago,Costa Rica"],"affiliations":[{"raw_affiliation_string":"Instituto Tecnol&#x00F3;gico de Costa Rica,Mechatronics Engineering,Cartago,Costa Rica","institution_ids":["https://openalex.org/I145372079"]}]},{"author_position":"middle","author":{"id":"https://openalex.org/A5112444164","display_name":"Arys Carrasquilla-Batista","orcid":null},"institutions":[{"id":"https://openalex.org/I145372079","display_name":"Instituto Tecnol\u00f3gico de Costa Rica","ror":"https://ror.org/04zhrfn38","country_code":"CR","type":"education","lineage":["https://openalex.org/I145372079"]}],"countries":["CR"],"is_corresponding":false,"raw_author_name":"Arys Carrasquilla-Batista","raw_affiliation_strings":["Instituto Tecnol&#x00F3;gico de Costa Rica,Mechatronics Engineering,Cartago,Costa Rica"],"affiliations":[{"raw_affiliation_string":"Instituto Tecnol&#x00F3;gico de Costa Rica,Mechatronics Engineering,Cartago,Costa Rica","institution_ids":["https://openalex.org/I145372079"]}]},{"author_position":"last","author":{"id":"https://openalex.org/A5084720481","display_name":"Gabriela Ortiz-Le\u00f3n","orcid":"https://orcid.org/0000-0002-0940-2677"},"institutions":[{"id":"https://openalex.org/I145372079","display_name":"Instituto Tecnol\u00f3gico de Costa Rica","ror":"https://ror.org/04zhrfn38","country_code":"CR","type":"education","lineage":["https://openalex.org/I145372079"]}],"countries":["CR"],"is_corresponding":false,"raw_author_name":"Gabriela Ortiz-Le\u00f3n","raw_affiliation_strings":["Instituto Tecnol&#x00F3;gico de Costa Rica,Mechatronics Engineering,Cartago,Costa Rica"],"affiliations":[{"raw_affiliation_string":"Instituto Tecnol&#x00F3;gico de Costa Rica,Mechatronics Engineering,Cartago,Costa Rica","institution_ids":["https://openalex.org/I145372079"]}]}],"institutions":[],"countries_distinct_count":1,"institutions_distinct_count":3,"corresponding_author_ids":["https://openalex.org/A5132606435"],"corresponding_institution_ids":["https://openalex.org/I145372079"],"apc_list":null,"apc_paid":null,"fwci":0.0,"has_fulltext":false,"cited_by_count":0,"citation_normalized_percentile":{"value":0.91316345,"is_in_top_1_percent":false,"is_in_top_10_percent":true},"cited_by_percentile_year":null,"biblio":{"volume":null,"issue":null,"first_page":"1","last_page":"5"},"is_retracted":false,"is_paratext":false,"is_xpac":false,"primary_topic":{"id":"https://openalex.org/T11023","display_name":"Prosthetics and Rehabilitation Robotics","score":0.5385000109672546,"subfield":{"id":"https://openalex.org/subfields/2204","display_name":"Biomedical Engineering"},"field":{"id":"https://openalex.org/fields/22","display_name":"Engineering"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}},"topics":[{"id":"https://openalex.org/T11023","display_name":"Prosthetics and Rehabilitation Robotics","score":0.5385000109672546,"subfield":{"id":"https://openalex.org/subfields/2204","display_name":"Biomedical Engineering"},"field":{"id":"https://openalex.org/fields/22","display_name":"Engineering"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}},{"id":"https://openalex.org/T10510","display_name":"Stroke Rehabilitation and Recovery","score":0.249099999666214,"subfield":{"id":"https://openalex.org/subfields/2742","display_name":"Rehabilitation"},"field":{"id":"https://openalex.org/fields/27","display_name":"Medicine"},"domain":{"id":"https://openalex.org/domains/4","display_name":"Health Sciences"}},{"id":"https://openalex.org/T10784","display_name":"Muscle activation and electromyography studies","score":0.06939999759197235,"subfield":{"id":"https://openalex.org/subfields/2204","display_name":"Biomedical Engineering"},"field":{"id":"https://openalex.org/fields/22","display_name":"Engineering"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}}],"keywords":[{"id":"https://openalex.org/keywords/mechatronics","display_name":"Mechatronics","score":0.7275000214576721},{"id":"https://openalex.org/keywords/interface","display_name":"Interface (matter)","score":0.5666999816894531},{"id":"https://openalex.org/keywords/automation","display_name":"Automation","score":0.5605000257492065},{"id":"https://openalex.org/keywords/user-interface","display_name":"User interface","score":0.5149000287055969},{"id":"https://openalex.org/keywords/rehabilitation","display_name":"Rehabilitation","score":0.44920000433921814},{"id":"https://openalex.org/keywords/inertial-measurement-unit","display_name":"Inertial measurement unit","score":0.3662000000476837}],"concepts":[{"id":"https://openalex.org/C28704281","wikidata":"https://www.wikidata.org/wiki/Q180165","display_name":"Mechatronics","level":2,"score":0.7275000214576721},{"id":"https://openalex.org/C127413603","wikidata":"https://www.wikidata.org/wiki/Q11023","display_name":"Engineering","level":0,"score":0.5913000106811523},{"id":"https://openalex.org/C113843644","wikidata":"https://www.wikidata.org/wiki/Q901882","display_name":"Interface (matter)","level":4,"score":0.5666999816894531},{"id":"https://openalex.org/C115901376","wikidata":"https://www.wikidata.org/wiki/Q184199","display_name":"Automation","level":2,"score":0.5605000257492065},{"id":"https://openalex.org/C89505385","wikidata":"https://www.wikidata.org/wiki/Q47146","display_name":"User interface","level":2,"score":0.5149000287055969},{"id":"https://openalex.org/C2778818304","wikidata":"https://www.wikidata.org/wiki/Q1819478","display_name":"Rehabilitation","level":2,"score":0.44920000433921814},{"id":"https://openalex.org/C107457646","wikidata":"https://www.wikidata.org/wiki/Q207434","display_name":"Human\u2013computer interaction","level":1,"score":0.40939998626708984},{"id":"https://openalex.org/C149635348","wikidata":"https://www.wikidata.org/wiki/Q193040","display_name":"Embedded system","level":1,"score":0.37860000133514404},{"id":"https://openalex.org/C44154836","wikidata":"https://www.wikidata.org/wiki/Q45045","display_name":"Simulation","level":1,"score":0.375900000333786},{"id":"https://openalex.org/C201995342","wikidata":"https://www.wikidata.org/wiki/Q682496","display_name":"Systems engineering","level":1,"score":0.3758000135421753},{"id":"https://openalex.org/C79061980","wikidata":"https://www.wikidata.org/wiki/Q941680","display_name":"Inertial measurement unit","level":2,"score":0.3662000000476837},{"id":"https://openalex.org/C2780395129","wikidata":"https://www.wikidata.org/wiki/Q1128971","display_name":"Rapid prototyping","level":2,"score":0.3580000102519989},{"id":"https://openalex.org/C41008148","wikidata":"https://www.wikidata.org/wiki/Q21198","display_name":"Computer science","level":0,"score":0.3564000129699707},{"id":"https://openalex.org/C81860439","wikidata":"https://www.wikidata.org/wiki/Q251212","display_name":"Internet of Things","level":2,"score":0.33730000257492065},{"id":"https://openalex.org/C2777904410","wikidata":"https://www.wikidata.org/wiki/Q7397","display_name":"Software","level":2,"score":0.2930000126361847},{"id":"https://openalex.org/C146549078","wikidata":"https://www.wikidata.org/wiki/Q191944","display_name":"Exoskeleton","level":2,"score":0.2669000029563904},{"id":"https://openalex.org/C2780168796","wikidata":"https://www.wikidata.org/wiki/Q954946","display_name":"Rehabilitation engineering","level":3,"score":0.257999986410141},{"id":"https://openalex.org/C133731056","wikidata":"https://www.wikidata.org/wiki/Q4917288","display_name":"Control engineering","level":1,"score":0.25529998540878296}],"mesh":[],"locations_count":1,"locations":[{"id":"doi:10.1109/lascas67804.2026.11457094","is_oa":false,"landing_page_url":"https://doi.org/10.1109/lascas67804.2026.11457094","pdf_url":null,"source":null,"license":null,"license_id":null,"version":"publishedVersion","is_accepted":true,"is_published":true,"raw_source_name":"2026 IEEE 17th Latin America Symposium on Circuits and System (LASCAS)","raw_type":"proceedings-article"}],"best_oa_location":null,"sustainable_development_goals":[{"score":0.4146348237991333,"display_name":"Partnerships for the goals","id":"https://metadata.un.org/sdg/17"}],"awards":[],"funders":[],"has_content":{"pdf":false,"grobid_xml":false},"content_urls":null,"referenced_works_count":4,"referenced_works":["https://openalex.org/W2062939404","https://openalex.org/W3016874997","https://openalex.org/W4321186596","https://openalex.org/W4389393069"],"related_works":[],"abstract_inverted_index":{"This":[0],"project":[1,20],"presents":[2],"the":[3,25,33,43,51],"design":[4,99],"and":[5,14,27,45,63,70,95,114],"prototyping":[6],"of":[7,32,37,47],"a":[8,88,106],"low-cost":[9],"mechatronic":[10],"device":[11],"for":[12,92],"passive":[13],"active":[15],"lower":[16],"limb":[17],"rehabilitation.":[18],"The":[19,54,98],"was":[21,80,100],"carried":[22],"out":[23],"at":[24],"Mechatronics":[26],"Automation":[28],"Research":[29],"Laboratory":[30],"(LIMA)":[31],"Costa":[34],"Rica":[35],"Institute":[36],"Technology":[38],"(TEC),":[39],"aiming":[40],"to":[41,82],"promote":[42],"development":[44],"accessibility":[46],"rehabilitation":[48,72],"technologies":[49],"in":[50],"local":[52,94],"context.":[53],"proposed":[55],"solution":[56],"allows":[57],"leg":[58],"exercises":[59],"based":[60],"on":[61,105],"flexion":[62],"extension":[64],"movements,":[65],"offering":[66],"adjustable":[67],"intensity":[68],"levels":[69],"selectable":[71],"modes":[73],"(active":[74],"or":[75],"passive).":[76],"An":[77],"interactive":[78],"game":[79],"integrated":[81],"enhance":[83],"user":[84,112],"engagement,":[85],"along":[86],"with":[87,116],"data":[89],"logging":[90],"system":[91],"both":[93],"cloud-based":[96],"storage.":[97],"validated":[101],"through":[102],"proof-of-concept":[103],"testing":[104],"functional":[107],"prototype,":[108],"assessing":[109],"mechanical":[110],"performance,":[111],"experience,":[113],"compliance":[115],"cost":[117],"targets.":[118]},"counts_by_year":[],"updated_date":"2026-04-02T13:53:19.096889","created_date":"2026-04-02T00:00:00"}
