{"id":"https://openalex.org/W2922437624","doi":"https://doi.org/10.1109/lascas.2019.8667564","title":"Reliability Assessment in Transmission Considering Intermittent Energy Resources","display_name":"Reliability Assessment in Transmission Considering Intermittent Energy Resources","publication_year":2019,"publication_date":"2019-02-01","ids":{"openalex":"https://openalex.org/W2922437624","doi":"https://doi.org/10.1109/lascas.2019.8667564","mag":"2922437624"},"language":"en","primary_location":{"id":"doi:10.1109/lascas.2019.8667564","is_oa":false,"landing_page_url":"https://doi.org/10.1109/lascas.2019.8667564","pdf_url":null,"source":null,"license":null,"license_id":null,"version":"publishedVersion","is_accepted":true,"is_published":true,"raw_source_name":"2019 IEEE 10th Latin American Symposium on Circuits &amp; Systems (LASCAS)","raw_type":"proceedings-article"},"type":"article","indexed_in":["crossref"],"open_access":{"is_oa":false,"oa_status":"closed","oa_url":null,"any_repository_has_fulltext":false},"authorships":[{"author_position":"first","author":{"id":"https://openalex.org/A5058246705","display_name":"Alfredo G. Tobon","orcid":null},"institutions":[],"countries":[],"is_corresponding":false,"raw_author_name":"Alfredo G. Tobon","raw_affiliation_strings":["Enerfin Colombia, Bogota, Colombia"],"raw_orcid":null,"affiliations":[{"raw_affiliation_string":"Enerfin Colombia, Bogota, Colombia","institution_ids":[]}]},{"author_position":"middle","author":{"id":"https://openalex.org/A5062650718","display_name":"Harold R. Chamorro","orcid":"https://orcid.org/0000-0003-2128-2425"},"institutions":[{"id":"https://openalex.org/I86987016","display_name":"KTH Royal Institute of Technology","ror":"https://ror.org/026vcq606","country_code":"SE","type":"education","lineage":["https://openalex.org/I86987016"]}],"countries":["SE"],"is_corresponding":false,"raw_author_name":"Harold R. Chamorro","raw_affiliation_strings":["KTH, Royal Institue fo Technology, Stockholm, Sweden"],"raw_orcid":null,"affiliations":[{"raw_affiliation_string":"KTH, Royal Institue fo Technology, Stockholm, Sweden","institution_ids":["https://openalex.org/I86987016"]}]},{"author_position":"middle","author":{"id":"https://openalex.org/A5050745579","display_name":"Francisco Gonz\u00e1lez-Longatt","orcid":"https://orcid.org/0000-0002-7157-9844"},"institutions":[{"id":"https://openalex.org/I143804889","display_name":"Loughborough University","ror":"https://ror.org/04vg4w365","country_code":"GB","type":"education","lineage":["https://openalex.org/I143804889"]}],"countries":["GB"],"is_corresponding":false,"raw_author_name":"Francisco Gonzalez-Longatt","raw_affiliation_strings":["Loughborough University, Loughborough, United Kingdom"],"raw_orcid":null,"affiliations":[{"raw_affiliation_string":"Loughborough University, Loughborough, United Kingdom","institution_ids":["https://openalex.org/I143804889"]}]},{"author_position":"last","author":{"id":"https://openalex.org/A5048657718","display_name":"Vijay K. Sood","orcid":"https://orcid.org/0000-0003-3859-3799"},"institutions":[],"countries":[],"is_corresponding":false,"raw_author_name":"Vijay K. Sood","raw_affiliation_strings":["Universityy of Ontario, Ontario, Canada"],"raw_orcid":null,"affiliations":[{"raw_affiliation_string":"Universityy of Ontario, Ontario, Canada","institution_ids":[]}]}],"institutions":[],"countries_distinct_count":2,"institutions_distinct_count":4,"corresponding_author_ids":[],"corresponding_institution_ids":[],"apc_list":null,"apc_paid":null,"fwci":2.0102,"has_fulltext":false,"cited_by_count":9,"citation_normalized_percentile":{"value":0.84709569,"is_in_top_1_percent":false,"is_in_top_10_percent":false},"cited_by_percentile_year":{"min":90,"max":97},"biblio":{"volume":null,"issue":null,"first_page":"193","last_page":"196"},"is_retracted":false,"is_paratext":false,"is_xpac":false,"primary_topic":{"id":"https://openalex.org/T11941","display_name":"Power System Reliability and Maintenance","score":0.9998999834060669,"subfield":{"id":"https://openalex.org/subfields/2213","display_name":"Safety, Risk, Reliability and Quality"},"field":{"id":"https://openalex.org/fields/22","display_name":"Engineering"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}},"topics":[{"id":"https://openalex.org/T11941","display_name":"Power System Reliability and Maintenance","score":0.9998999834060669,"subfield":{"id":"https://openalex.org/subfields/2213","display_name":"Safety, Risk, Reliability and Quality"},"field":{"id":"https://openalex.org/fields/22","display_name":"Engineering"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}},{"id":"https://openalex.org/T10454","display_name":"Optimal Power Flow Distribution","score":0.989300012588501,"subfield":{"id":"https://openalex.org/subfields/2208","display_name":"Electrical and Electronic Engineering"},"field":{"id":"https://openalex.org/fields/22","display_name":"Engineering"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}},{"id":"https://openalex.org/T11102","display_name":"HVDC Systems and Fault Protection","score":0.9799000024795532,"subfield":{"id":"https://openalex.org/subfields/2208","display_name":"Electrical and Electronic Engineering"},"field":{"id":"https://openalex.org/fields/22","display_name":"Engineering"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}}],"keywords":[{"id":"https://openalex.org/keywords/reliability-engineering","display_name":"Reliability engineering","score":0.723957896232605},{"id":"https://openalex.org/keywords/electric-power-system","display_name":"Electric power system","score":0.6502714157104492},{"id":"https://openalex.org/keywords/wind-power","display_name":"Wind power","score":0.6179280877113342},{"id":"https://openalex.org/keywords/reliability","display_name":"Reliability (semiconductor)","score":0.577597975730896},{"id":"https://openalex.org/keywords/computer-science","display_name":"Computer science","score":0.5659039616584778},{"id":"https://openalex.org/keywords/distributed-generation","display_name":"Distributed generation","score":0.5322219133377075},{"id":"https://openalex.org/keywords/grid","display_name":"Grid","score":0.5100823044776917},{"id":"https://openalex.org/keywords/electricity-generation","display_name":"Electricity generation","score":0.44800785183906555},{"id":"https://openalex.org/keywords/renewable-energy","display_name":"Renewable energy","score":0.386176198720932},{"id":"https://openalex.org/keywords/power","display_name":"Power (physics)","score":0.23745864629745483},{"id":"https://openalex.org/keywords/engineering","display_name":"Engineering","score":0.23721149563789368},{"id":"https://openalex.org/keywords/electrical-engineering","display_name":"Electrical engineering","score":0.20154961943626404}],"concepts":[{"id":"https://openalex.org/C200601418","wikidata":"https://www.wikidata.org/wiki/Q2193887","display_name":"Reliability engineering","level":1,"score":0.723957896232605},{"id":"https://openalex.org/C89227174","wikidata":"https://www.wikidata.org/wiki/Q2388981","display_name":"Electric power system","level":3,"score":0.6502714157104492},{"id":"https://openalex.org/C78600449","wikidata":"https://www.wikidata.org/wiki/Q43302","display_name":"Wind power","level":2,"score":0.6179280877113342},{"id":"https://openalex.org/C43214815","wikidata":"https://www.wikidata.org/wiki/Q7310987","display_name":"Reliability (semiconductor)","level":3,"score":0.577597975730896},{"id":"https://openalex.org/C41008148","wikidata":"https://www.wikidata.org/wiki/Q21198","display_name":"Computer science","level":0,"score":0.5659039616584778},{"id":"https://openalex.org/C544738498","wikidata":"https://www.wikidata.org/wiki/Q861135","display_name":"Distributed generation","level":3,"score":0.5322219133377075},{"id":"https://openalex.org/C187691185","wikidata":"https://www.wikidata.org/wiki/Q2020720","display_name":"Grid","level":2,"score":0.5100823044776917},{"id":"https://openalex.org/C423512","wikidata":"https://www.wikidata.org/wiki/Q383973","display_name":"Electricity generation","level":3,"score":0.44800785183906555},{"id":"https://openalex.org/C188573790","wikidata":"https://www.wikidata.org/wiki/Q12705","display_name":"Renewable energy","level":2,"score":0.386176198720932},{"id":"https://openalex.org/C163258240","wikidata":"https://www.wikidata.org/wiki/Q25342","display_name":"Power (physics)","level":2,"score":0.23745864629745483},{"id":"https://openalex.org/C127413603","wikidata":"https://www.wikidata.org/wiki/Q11023","display_name":"Engineering","level":0,"score":0.23721149563789368},{"id":"https://openalex.org/C119599485","wikidata":"https://www.wikidata.org/wiki/Q43035","display_name":"Electrical engineering","level":1,"score":0.20154961943626404},{"id":"https://openalex.org/C62520636","wikidata":"https://www.wikidata.org/wiki/Q944","display_name":"Quantum mechanics","level":1,"score":0.0},{"id":"https://openalex.org/C2524010","wikidata":"https://www.wikidata.org/wiki/Q8087","display_name":"Geometry","level":1,"score":0.0},{"id":"https://openalex.org/C33923547","wikidata":"https://www.wikidata.org/wiki/Q395","display_name":"Mathematics","level":0,"score":0.0},{"id":"https://openalex.org/C121332964","wikidata":"https://www.wikidata.org/wiki/Q413","display_name":"Physics","level":0,"score":0.0}],"mesh":[],"locations_count":1,"locations":[{"id":"doi:10.1109/lascas.2019.8667564","is_oa":false,"landing_page_url":"https://doi.org/10.1109/lascas.2019.8667564","pdf_url":null,"source":null,"license":null,"license_id":null,"version":"publishedVersion","is_accepted":true,"is_published":true,"raw_source_name":"2019 IEEE 10th Latin American Symposium on Circuits &amp; Systems (LASCAS)","raw_type":"proceedings-article"}],"best_oa_location":null,"sustainable_development_goals":[{"id":"https://metadata.un.org/sdg/7","score":0.6700000166893005,"display_name":"Affordable and clean energy"}],"awards":[],"funders":[],"has_content":{"grobid_xml":false,"pdf":false},"content_urls":null,"referenced_works_count":10,"referenced_works":["https://openalex.org/W1502876580","https://openalex.org/W1518290592","https://openalex.org/W2009163808","https://openalex.org/W2011481046","https://openalex.org/W2014233392","https://openalex.org/W2033225140","https://openalex.org/W2102381184","https://openalex.org/W2153672555","https://openalex.org/W2989586196","https://openalex.org/W6675527308"],"related_works":["https://openalex.org/W3017124762","https://openalex.org/W3097919110","https://openalex.org/W2710710002","https://openalex.org/W2021194995","https://openalex.org/W4221107878","https://openalex.org/W4220683285","https://openalex.org/W2557657611","https://openalex.org/W4212924852","https://openalex.org/W2943443863","https://openalex.org/W2993707183"],"abstract_inverted_index":{"Current":[0],"power":[1,44,61,100,131,134],"systems":[2,56],"face":[3],"different":[4],"types":[5],"of":[6,15,73,82,92,139,146],"problems,":[7],"such":[8],"as":[9],"the":[10,13,16,35,41,85,90,108,125,142,147],"balance":[11],"in":[12,37,80,141],"adequacy":[14],"resources,":[17,49],"security,":[18],"grid":[19,42],"reliability,":[20],"complementarity,":[21],"resilience,":[22],"stability":[23],"and":[24,52,122,132,154],"economic":[25],"efficiency,":[26],"to":[27,159],"name":[28],"a":[29,93,97],"few.":[30],"This":[31,87],"paper":[32,88],"deals":[33],"with":[34,46,57,114,135],"problems":[36],"reliability":[38,83,98,112],"imposed":[39],"onto":[40],"by":[43],"generation":[45,115],"intermittent":[47],"energy":[48,66,118],"i.e.":[50],"wind":[51,130],"solar":[53,133],"energy.":[54],"Power":[55],"high":[58],"penetration":[59,140],"grid-connected":[60],"generators":[62],"that":[63,102],"use":[64],"an":[65,136],"source":[67],"which":[68],"is":[69,127],"not":[70],"available":[71],"because":[72],"its":[74],"random":[75],"nature,":[76],"are":[77],"addressed":[78],"here":[79],"terms":[81],"for":[84],"grid.":[86,143],"presents":[89],"results":[91],"study":[94],"done":[95],"on":[96],"test":[99,161],"system":[101,109,126,148],"takes":[103],"into":[104],"account,":[105],"first":[106],"how":[107],"behaves":[110],"regarding":[111],"indexes":[113],"from":[116],"conventional":[117],"resources":[119],"(Fossil,":[120],"Nuclear":[121],"Hydropower),":[123],"Then":[124],"presented":[128],"introducing":[129],"elevated":[137],"degree":[138],"The":[144],"evaluation":[145],"was":[149],"performed":[150],"using":[151],"computational":[152],"modelling":[153],"can":[155],"potentially":[156],"be":[157],"applied":[158],"other":[160],"systems.":[162]},"counts_by_year":[{"year":2022,"cited_by_count":1},{"year":2021,"cited_by_count":3},{"year":2020,"cited_by_count":3},{"year":2019,"cited_by_count":2}],"updated_date":"2026-06-11T09:08:48.828518","created_date":"2025-10-10T00:00:00"}
