{"id":"https://openalex.org/W3015318131","doi":"https://doi.org/10.1109/kst48564.2020.9059419","title":"Capital Cost based Planning and Optimal Sizing of a Small Community Smart Microgrid","display_name":"Capital Cost based Planning and Optimal Sizing of a Small Community Smart Microgrid","publication_year":2020,"publication_date":"2020-01-01","ids":{"openalex":"https://openalex.org/W3015318131","doi":"https://doi.org/10.1109/kst48564.2020.9059419","mag":"3015318131"},"language":"en","primary_location":{"id":"doi:10.1109/kst48564.2020.9059419","is_oa":false,"landing_page_url":"https://doi.org/10.1109/kst48564.2020.9059419","pdf_url":null,"source":null,"license":null,"license_id":null,"version":"publishedVersion","is_accepted":true,"is_published":true,"raw_source_name":"2020 12th International Conference on Knowledge and Smart Technology (KST)","raw_type":"proceedings-article"},"type":"article","indexed_in":["crossref"],"open_access":{"is_oa":false,"oa_status":"closed","oa_url":null,"any_repository_has_fulltext":false},"authorships":[{"author_position":"first","author":{"id":"https://openalex.org/A5101966448","display_name":"Maneesh Kumar","orcid":"https://orcid.org/0000-0002-5054-7632"},"institutions":[{"id":"https://openalex.org/I154851008","display_name":"Indian Institute of Technology Roorkee","ror":"https://ror.org/00582g326","country_code":"IN","type":"education","lineage":["https://openalex.org/I154851008"]}],"countries":["IN"],"is_corresponding":true,"raw_author_name":"Maneesh Kumar","raw_affiliation_strings":["Department of Electrical Engineering, Indian Institute of Technology, Roorkee, India"],"affiliations":[{"raw_affiliation_string":"Department of Electrical Engineering, Indian Institute of Technology, Roorkee, India","institution_ids":["https://openalex.org/I154851008"]}]},{"author_position":"last","author":{"id":"https://openalex.org/A5000206206","display_name":"Barjeev Tyagi","orcid":"https://orcid.org/0000-0001-6277-3066"},"institutions":[{"id":"https://openalex.org/I154851008","display_name":"Indian Institute of Technology Roorkee","ror":"https://ror.org/00582g326","country_code":"IN","type":"education","lineage":["https://openalex.org/I154851008"]}],"countries":["IN"],"is_corresponding":false,"raw_author_name":"Barjeev Tyagi","raw_affiliation_strings":["Department of Electrical Engineering, Indian Institute of Technology, Roorkee, India"],"affiliations":[{"raw_affiliation_string":"Department of Electrical Engineering, Indian Institute of Technology, Roorkee, India","institution_ids":["https://openalex.org/I154851008"]}]}],"institutions":[],"countries_distinct_count":1,"institutions_distinct_count":2,"corresponding_author_ids":["https://openalex.org/A5101966448"],"corresponding_institution_ids":["https://openalex.org/I154851008"],"apc_list":null,"apc_paid":null,"fwci":0.6225,"has_fulltext":false,"cited_by_count":7,"citation_normalized_percentile":{"value":0.67163453,"is_in_top_1_percent":false,"is_in_top_10_percent":false},"cited_by_percentile_year":{"min":89,"max":99},"biblio":{"volume":null,"issue":null,"first_page":"121","last_page":"126"},"is_retracted":false,"is_paratext":false,"is_xpac":false,"primary_topic":{"id":"https://openalex.org/T10603","display_name":"Smart Grid Energy Management","score":0.9998999834060669,"subfield":{"id":"https://openalex.org/subfields/2208","display_name":"Electrical and Electronic Engineering"},"field":{"id":"https://openalex.org/fields/22","display_name":"Engineering"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}},"topics":[{"id":"https://openalex.org/T10603","display_name":"Smart Grid Energy Management","score":0.9998999834060669,"subfield":{"id":"https://openalex.org/subfields/2208","display_name":"Electrical and Electronic Engineering"},"field":{"id":"https://openalex.org/fields/22","display_name":"Engineering"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}},{"id":"https://openalex.org/T10223","display_name":"Microgrid Control and Optimization","score":0.9994999766349792,"subfield":{"id":"https://openalex.org/subfields/2207","display_name":"Control and Systems Engineering"},"field":{"id":"https://openalex.org/fields/22","display_name":"Engineering"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}},{"id":"https://openalex.org/T11185","display_name":"Integrated Energy Systems Optimization","score":0.9957000017166138,"subfield":{"id":"https://openalex.org/subfields/2208","display_name":"Electrical and Electronic Engineering"},"field":{"id":"https://openalex.org/fields/22","display_name":"Engineering"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}}],"keywords":[{"id":"https://openalex.org/keywords/microgrid","display_name":"Microgrid","score":0.8994529843330383},{"id":"https://openalex.org/keywords/sizing","display_name":"Sizing","score":0.7237833142280579},{"id":"https://openalex.org/keywords/mathematical-optimization","display_name":"Mathematical optimization","score":0.6641572713851929},{"id":"https://openalex.org/keywords/computer-science","display_name":"Computer science","score":0.5792360901832581},{"id":"https://openalex.org/keywords/energy-management","display_name":"Energy management","score":0.56987464427948},{"id":"https://openalex.org/keywords/distributed-generation","display_name":"Distributed generation","score":0.5580590963363647},{"id":"https://openalex.org/keywords/heuristic","display_name":"Heuristic","score":0.5476849675178528},{"id":"https://openalex.org/keywords/capital-cost","display_name":"Capital cost","score":0.5139946341514587},{"id":"https://openalex.org/keywords/reliability","display_name":"Reliability (semiconductor)","score":0.5080587863922119},{"id":"https://openalex.org/keywords/electric-power-system","display_name":"Electric power system","score":0.47283750772476196},{"id":"https://openalex.org/keywords/energy-storage","display_name":"Energy storage","score":0.45411232113838196},{"id":"https://openalex.org/keywords/demand-response","display_name":"Demand response","score":0.4536759555339813},{"id":"https://openalex.org/keywords/smart-grid","display_name":"Smart grid","score":0.4362798035144806},{"id":"https://openalex.org/keywords/optimization-problem","display_name":"Optimization problem","score":0.4312702417373657},{"id":"https://openalex.org/keywords/reliability-engineering","display_name":"Reliability engineering","score":0.4300094246864319},{"id":"https://openalex.org/keywords/energy","display_name":"Energy (signal processing)","score":0.31240198016166687},{"id":"https://openalex.org/keywords/power","display_name":"Power (physics)","score":0.29971635341644287},{"id":"https://openalex.org/keywords/engineering","display_name":"Engineering","score":0.29050517082214355},{"id":"https://openalex.org/keywords/electricity","display_name":"Electricity","score":0.24322494864463806},{"id":"https://openalex.org/keywords/renewable-energy","display_name":"Renewable energy","score":0.18334746360778809},{"id":"https://openalex.org/keywords/mathematics","display_name":"Mathematics","score":0.1157829761505127}],"concepts":[{"id":"https://openalex.org/C2776784348","wikidata":"https://www.wikidata.org/wiki/Q5762595","display_name":"Microgrid","level":3,"score":0.8994529843330383},{"id":"https://openalex.org/C2777767291","wikidata":"https://www.wikidata.org/wiki/Q1080291","display_name":"Sizing","level":2,"score":0.7237833142280579},{"id":"https://openalex.org/C126255220","wikidata":"https://www.wikidata.org/wiki/Q141495","display_name":"Mathematical optimization","level":1,"score":0.6641572713851929},{"id":"https://openalex.org/C41008148","wikidata":"https://www.wikidata.org/wiki/Q21198","display_name":"Computer science","level":0,"score":0.5792360901832581},{"id":"https://openalex.org/C7817414","wikidata":"https://www.wikidata.org/wiki/Q1779504","display_name":"Energy management","level":3,"score":0.56987464427948},{"id":"https://openalex.org/C544738498","wikidata":"https://www.wikidata.org/wiki/Q861135","display_name":"Distributed generation","level":3,"score":0.5580590963363647},{"id":"https://openalex.org/C173801870","wikidata":"https://www.wikidata.org/wiki/Q201413","display_name":"Heuristic","level":2,"score":0.5476849675178528},{"id":"https://openalex.org/C157062255","wikidata":"https://www.wikidata.org/wiki/Q5035697","display_name":"Capital cost","level":2,"score":0.5139946341514587},{"id":"https://openalex.org/C43214815","wikidata":"https://www.wikidata.org/wiki/Q7310987","display_name":"Reliability (semiconductor)","level":3,"score":0.5080587863922119},{"id":"https://openalex.org/C89227174","wikidata":"https://www.wikidata.org/wiki/Q2388981","display_name":"Electric power system","level":3,"score":0.47283750772476196},{"id":"https://openalex.org/C73916439","wikidata":"https://www.wikidata.org/wiki/Q837718","display_name":"Energy storage","level":3,"score":0.45411232113838196},{"id":"https://openalex.org/C2779438525","wikidata":"https://www.wikidata.org/wiki/Q5255048","display_name":"Demand response","level":3,"score":0.4536759555339813},{"id":"https://openalex.org/C10558101","wikidata":"https://www.wikidata.org/wiki/Q689855","display_name":"Smart grid","level":2,"score":0.4362798035144806},{"id":"https://openalex.org/C137836250","wikidata":"https://www.wikidata.org/wiki/Q984063","display_name":"Optimization problem","level":2,"score":0.4312702417373657},{"id":"https://openalex.org/C200601418","wikidata":"https://www.wikidata.org/wiki/Q2193887","display_name":"Reliability engineering","level":1,"score":0.4300094246864319},{"id":"https://openalex.org/C186370098","wikidata":"https://www.wikidata.org/wiki/Q442787","display_name":"Energy (signal processing)","level":2,"score":0.31240198016166687},{"id":"https://openalex.org/C163258240","wikidata":"https://www.wikidata.org/wiki/Q25342","display_name":"Power (physics)","level":2,"score":0.29971635341644287},{"id":"https://openalex.org/C127413603","wikidata":"https://www.wikidata.org/wiki/Q11023","display_name":"Engineering","level":0,"score":0.29050517082214355},{"id":"https://openalex.org/C206658404","wikidata":"https://www.wikidata.org/wiki/Q12725","display_name":"Electricity","level":2,"score":0.24322494864463806},{"id":"https://openalex.org/C188573790","wikidata":"https://www.wikidata.org/wiki/Q12705","display_name":"Renewable energy","level":2,"score":0.18334746360778809},{"id":"https://openalex.org/C33923547","wikidata":"https://www.wikidata.org/wiki/Q395","display_name":"Mathematics","level":0,"score":0.1157829761505127},{"id":"https://openalex.org/C105795698","wikidata":"https://www.wikidata.org/wiki/Q12483","display_name":"Statistics","level":1,"score":0.0},{"id":"https://openalex.org/C119599485","wikidata":"https://www.wikidata.org/wiki/Q43035","display_name":"Electrical engineering","level":1,"score":0.0},{"id":"https://openalex.org/C142362112","wikidata":"https://www.wikidata.org/wiki/Q735","display_name":"Art","level":0,"score":0.0},{"id":"https://openalex.org/C62520636","wikidata":"https://www.wikidata.org/wiki/Q944","display_name":"Quantum mechanics","level":1,"score":0.0},{"id":"https://openalex.org/C121332964","wikidata":"https://www.wikidata.org/wiki/Q413","display_name":"Physics","level":0,"score":0.0},{"id":"https://openalex.org/C2775924081","wikidata":"https://www.wikidata.org/wiki/Q55608371","display_name":"Control (management)","level":2,"score":0.0},{"id":"https://openalex.org/C153349607","wikidata":"https://www.wikidata.org/wiki/Q36649","display_name":"Visual arts","level":1,"score":0.0},{"id":"https://openalex.org/C154945302","wikidata":"https://www.wikidata.org/wiki/Q11660","display_name":"Artificial intelligence","level":1,"score":0.0}],"mesh":[],"locations_count":1,"locations":[{"id":"doi:10.1109/kst48564.2020.9059419","is_oa":false,"landing_page_url":"https://doi.org/10.1109/kst48564.2020.9059419","pdf_url":null,"source":null,"license":null,"license_id":null,"version":"publishedVersion","is_accepted":true,"is_published":true,"raw_source_name":"2020 12th International Conference on Knowledge and Smart Technology (KST)","raw_type":"proceedings-article"}],"best_oa_location":null,"sustainable_development_goals":[{"score":0.4000000059604645,"display_name":"Affordable and clean energy","id":"https://metadata.un.org/sdg/7"}],"awards":[],"funders":[],"has_content":{"grobid_xml":false,"pdf":false},"content_urls":null,"referenced_works_count":16,"referenced_works":["https://openalex.org/W1981585916","https://openalex.org/W1988725814","https://openalex.org/W2009461239","https://openalex.org/W2045361880","https://openalex.org/W2078793588","https://openalex.org/W2102828113","https://openalex.org/W2121362791","https://openalex.org/W2146738646","https://openalex.org/W2326513046","https://openalex.org/W2331168545","https://openalex.org/W2526316194","https://openalex.org/W2559879705","https://openalex.org/W2601171548","https://openalex.org/W2748388862","https://openalex.org/W2761901817","https://openalex.org/W2904568254"],"related_works":["https://openalex.org/W1574359403","https://openalex.org/W2057975886","https://openalex.org/W4308700935","https://openalex.org/W4210780382","https://openalex.org/W2333017163","https://openalex.org/W2347673489","https://openalex.org/W2964937504","https://openalex.org/W2169268775","https://openalex.org/W2371966636","https://openalex.org/W1986364304"],"abstract_inverted_index":{"A":[0],"cost-effective":[1],"microgrid":[2],"planning":[3,21],"is":[4,56,79,90],"essential":[5],"for":[6,61,92],"a":[7,15,26,37,101,131],"reliable":[8],"and":[9,22,96,126],"economic":[10],"system.":[11],"This":[12],"paper":[13],"proposes":[14],"demand":[16],"side":[17],"management":[18],"(DSM)":[19],"based":[20],"optimal":[23,93,98,115,121,124],"sizing":[24],"of":[25,67,117,136],"small":[27],"community":[28],"smart":[29],"microgrid.":[30],"For":[31],"encouraging":[32],"the":[33,50,75,83,97,110,114,123,127,137],"green":[34],"energy":[35,44,52],"solutions,":[36],"biogas":[38],"power":[39],"plant":[40],"supported":[41],"by":[42],"an":[43,71],"storage":[45],"system":[46,63,105],"are":[47,107,142],"considered":[48,108],"as":[49],"distributed":[51],"resources":[53],"(DERs).":[54],"DSM":[55,68],"implemented":[57],"using":[58,100],"dynamic":[59],"algorithms":[60],"maintaining":[62],"reliability.":[64],"The":[65,87],"integration":[66],"results":[69],"in":[70,74,144],"overall":[72,138],"improvement":[73],"load":[76],"curve,":[77],"which":[78],"used":[80],"to":[81],"reformulate":[82],"original":[84],"optimization":[85,88],"problem.":[86],"problem":[89,139],"solved":[91],"MG":[94],"size":[95],"cost":[99],"heuristic":[102],"approach.":[103],"Various":[104],"constraints":[106],"during":[109],"optimization.":[111],"Results":[112],"provide":[113],"number":[116],"DERs,":[118],"their":[119],"corresponding":[120],"ratings,":[122],"cost,":[125],"annual":[128],"savings":[129],"through":[130],"numerical":[132],"case":[133],"study.":[134],"Solutions":[135],"under":[140],"consideration":[141],"deterministic":[143],"nature.":[145]},"counts_by_year":[{"year":2026,"cited_by_count":1},{"year":2023,"cited_by_count":2},{"year":2022,"cited_by_count":1},{"year":2021,"cited_by_count":3}],"updated_date":"2026-03-27T14:29:43.386196","created_date":"2025-10-10T00:00:00"}
