{"id":"https://openalex.org/W2522953484","doi":"https://doi.org/10.1109/jssc.2016.2606581","title":"A 2 MHz 12\u2013100 V 90% Efficiency Self-Balancing ZVS Reconfigurable Three-Level DC-DC Regulator With Constant-Frequency Adaptive-On-Time $V^{2}$ Control and Nanosecond-Scale ZVS Turn-On Delay","display_name":"A 2 MHz 12\u2013100 V 90% Efficiency Self-Balancing ZVS Reconfigurable Three-Level DC-DC Regulator With Constant-Frequency Adaptive-On-Time $V^{2}$ Control and Nanosecond-Scale ZVS Turn-On Delay","publication_year":2016,"publication_date":"2016-09-22","ids":{"openalex":"https://openalex.org/W2522953484","doi":"https://doi.org/10.1109/jssc.2016.2606581","mag":"2522953484"},"language":"en","primary_location":{"id":"doi:10.1109/jssc.2016.2606581","is_oa":false,"landing_page_url":"https://doi.org/10.1109/jssc.2016.2606581","pdf_url":null,"source":{"id":"https://openalex.org/S83637746","display_name":"IEEE Journal of Solid-State Circuits","issn_l":"0018-9200","issn":["0018-9200","1558-173X"],"is_oa":false,"is_in_doaj":false,"is_core":true,"host_organization":"https://openalex.org/P4310319808","host_organization_name":"Institute of Electrical and Electronics Engineers","host_organization_lineage":["https://openalex.org/P4310319808"],"host_organization_lineage_names":["Institute of Electrical and Electronics Engineers"],"type":"journal"},"license":null,"license_id":null,"version":"publishedVersion","is_accepted":true,"is_published":true,"raw_source_name":"IEEE Journal of Solid-State Circuits","raw_type":"journal-article"},"type":"article","indexed_in":["crossref"],"open_access":{"is_oa":false,"oa_status":"closed","oa_url":null,"any_repository_has_fulltext":false},"authorships":[{"author_position":"first","author":{"id":"https://openalex.org/A5102357381","display_name":"Jing Xue","orcid":"https://orcid.org/0009-0007-1062-2881"},"institutions":[],"countries":[],"is_corresponding":false,"raw_author_name":"Jing Xue","raw_affiliation_strings":["Linear Technology Corporation, Milpitas, CA, USA"],"raw_orcid":null,"affiliations":[{"raw_affiliation_string":"Linear Technology Corporation, Milpitas, CA, USA","institution_ids":[]}]},{"author_position":"last","author":{"id":"https://openalex.org/A5035105400","display_name":"Hoi Lee","orcid":"https://orcid.org/0000-0003-1945-6887"},"institutions":[{"id":"https://openalex.org/I162577319","display_name":"The University of Texas at Dallas","ror":"https://ror.org/049emcs32","country_code":"US","type":"education","lineage":["https://openalex.org/I162577319"]}],"countries":["US"],"is_corresponding":false,"raw_author_name":"Hoi Lee","raw_affiliation_strings":["University of Texas at Dallas, Richardson, TX, USA"],"raw_orcid":"https://orcid.org/0000-0003-1945-6887","affiliations":[{"raw_affiliation_string":"University of Texas at Dallas, Richardson, TX, USA","institution_ids":["https://openalex.org/I162577319"]}]}],"institutions":[],"countries_distinct_count":1,"institutions_distinct_count":2,"corresponding_author_ids":[],"corresponding_institution_ids":[],"apc_list":null,"apc_paid":null,"fwci":2.4182,"has_fulltext":false,"cited_by_count":73,"citation_normalized_percentile":{"value":0.8982476,"is_in_top_1_percent":false,"is_in_top_10_percent":false},"cited_by_percentile_year":{"min":94,"max":100},"biblio":{"volume":"51","issue":"12","first_page":"2854","last_page":"2866"},"is_retracted":false,"is_paratext":false,"is_xpac":false,"primary_topic":{"id":"https://openalex.org/T10175","display_name":"Advanced DC-DC Converters","score":0.9998999834060669,"subfield":{"id":"https://openalex.org/subfields/2208","display_name":"Electrical and Electronic Engineering"},"field":{"id":"https://openalex.org/fields/22","display_name":"Engineering"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}},"topics":[{"id":"https://openalex.org/T10175","display_name":"Advanced DC-DC Converters","score":0.9998999834060669,"subfield":{"id":"https://openalex.org/subfields/2208","display_name":"Electrical and Electronic Engineering"},"field":{"id":"https://openalex.org/fields/22","display_name":"Engineering"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}},{"id":"https://openalex.org/T10228","display_name":"Multilevel Inverters and Converters","score":0.9997000098228455,"subfield":{"id":"https://openalex.org/subfields/2208","display_name":"Electrical and Electronic Engineering"},"field":{"id":"https://openalex.org/fields/22","display_name":"Engineering"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}},{"id":"https://openalex.org/T10361","display_name":"Silicon Carbide Semiconductor Technologies","score":0.9991000294685364,"subfield":{"id":"https://openalex.org/subfields/2208","display_name":"Electrical and Electronic Engineering"},"field":{"id":"https://openalex.org/fields/22","display_name":"Engineering"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}}],"keywords":[{"id":"https://openalex.org/keywords/low-dropout-regulator","display_name":"Low-dropout regulator","score":0.6814815402030945},{"id":"https://openalex.org/keywords/capacitance","display_name":"Capacitance","score":0.5395002365112305},{"id":"https://openalex.org/keywords/capacitor","display_name":"Capacitor","score":0.5079634785652161},{"id":"https://openalex.org/keywords/electrical-engineering","display_name":"Electrical engineering","score":0.4937385022640228},{"id":"https://openalex.org/keywords/voltage","display_name":"Voltage","score":0.48420193791389465},{"id":"https://openalex.org/keywords/voltage-regulator","display_name":"Voltage regulator","score":0.47603821754455566},{"id":"https://openalex.org/keywords/power","display_name":"Power (physics)","score":0.43090328574180603},{"id":"https://openalex.org/keywords/buck-converter","display_name":"Buck converter","score":0.4272219240665436},{"id":"https://openalex.org/keywords/duty-cycle","display_name":"Duty cycle","score":0.42715051770210266},{"id":"https://openalex.org/keywords/computer-science","display_name":"Computer science","score":0.3887646496295929},{"id":"https://openalex.org/keywords/topology","display_name":"Topology (electrical circuits)","score":0.38289740681648254},{"id":"https://openalex.org/keywords/electronic-engineering","display_name":"Electronic engineering","score":0.36211496591567993},{"id":"https://openalex.org/keywords/dropout-voltage","display_name":"Dropout voltage","score":0.35267215967178345},{"id":"https://openalex.org/keywords/physics","display_name":"Physics","score":0.29344266653060913},{"id":"https://openalex.org/keywords/engineering","display_name":"Engineering","score":0.20116189122200012}],"concepts":[{"id":"https://openalex.org/C140501009","wikidata":"https://www.wikidata.org/wiki/Q6692746","display_name":"Low-dropout regulator","level":5,"score":0.6814815402030945},{"id":"https://openalex.org/C30066665","wikidata":"https://www.wikidata.org/wiki/Q164399","display_name":"Capacitance","level":3,"score":0.5395002365112305},{"id":"https://openalex.org/C52192207","wikidata":"https://www.wikidata.org/wiki/Q5322","display_name":"Capacitor","level":3,"score":0.5079634785652161},{"id":"https://openalex.org/C119599485","wikidata":"https://www.wikidata.org/wiki/Q43035","display_name":"Electrical engineering","level":1,"score":0.4937385022640228},{"id":"https://openalex.org/C165801399","wikidata":"https://www.wikidata.org/wiki/Q25428","display_name":"Voltage","level":2,"score":0.48420193791389465},{"id":"https://openalex.org/C110706871","wikidata":"https://www.wikidata.org/wiki/Q851210","display_name":"Voltage regulator","level":3,"score":0.47603821754455566},{"id":"https://openalex.org/C163258240","wikidata":"https://www.wikidata.org/wiki/Q25342","display_name":"Power (physics)","level":2,"score":0.43090328574180603},{"id":"https://openalex.org/C150818752","wikidata":"https://www.wikidata.org/wiki/Q83804","display_name":"Buck converter","level":3,"score":0.4272219240665436},{"id":"https://openalex.org/C199822604","wikidata":"https://www.wikidata.org/wiki/Q557120","display_name":"Duty cycle","level":3,"score":0.42715051770210266},{"id":"https://openalex.org/C41008148","wikidata":"https://www.wikidata.org/wiki/Q21198","display_name":"Computer science","level":0,"score":0.3887646496295929},{"id":"https://openalex.org/C184720557","wikidata":"https://www.wikidata.org/wiki/Q7825049","display_name":"Topology (electrical circuits)","level":2,"score":0.38289740681648254},{"id":"https://openalex.org/C24326235","wikidata":"https://www.wikidata.org/wiki/Q126095","display_name":"Electronic engineering","level":1,"score":0.36211496591567993},{"id":"https://openalex.org/C15032970","wikidata":"https://www.wikidata.org/wiki/Q851210","display_name":"Dropout voltage","level":4,"score":0.35267215967178345},{"id":"https://openalex.org/C121332964","wikidata":"https://www.wikidata.org/wiki/Q413","display_name":"Physics","level":0,"score":0.29344266653060913},{"id":"https://openalex.org/C127413603","wikidata":"https://www.wikidata.org/wiki/Q11023","display_name":"Engineering","level":0,"score":0.20116189122200012},{"id":"https://openalex.org/C17525397","wikidata":"https://www.wikidata.org/wiki/Q176140","display_name":"Electrode","level":2,"score":0.0},{"id":"https://openalex.org/C62520636","wikidata":"https://www.wikidata.org/wiki/Q944","display_name":"Quantum mechanics","level":1,"score":0.0}],"mesh":[],"locations_count":1,"locations":[{"id":"doi:10.1109/jssc.2016.2606581","is_oa":false,"landing_page_url":"https://doi.org/10.1109/jssc.2016.2606581","pdf_url":null,"source":{"id":"https://openalex.org/S83637746","display_name":"IEEE Journal of Solid-State Circuits","issn_l":"0018-9200","issn":["0018-9200","1558-173X"],"is_oa":false,"is_in_doaj":false,"is_core":true,"host_organization":"https://openalex.org/P4310319808","host_organization_name":"Institute of Electrical and Electronics Engineers","host_organization_lineage":["https://openalex.org/P4310319808"],"host_organization_lineage_names":["Institute of Electrical and Electronics Engineers"],"type":"journal"},"license":null,"license_id":null,"version":"publishedVersion","is_accepted":true,"is_published":true,"raw_source_name":"IEEE Journal of Solid-State Circuits","raw_type":"journal-article"}],"best_oa_location":null,"sustainable_development_goals":[{"display_name":"Affordable and clean energy","id":"https://metadata.un.org/sdg/7","score":0.8899999856948853}],"awards":[{"id":"https://openalex.org/G791134208","display_name":null,"funder_award_id":"ECCS-1056013","funder_id":"https://openalex.org/F4320306076","funder_display_name":"National Science Foundation"}],"funders":[{"id":"https://openalex.org/F4320306076","display_name":"National Science Foundation","ror":"https://ror.org/021nxhr62"}],"has_content":{"grobid_xml":false,"pdf":false},"content_urls":null,"referenced_works_count":26,"referenced_works":["https://openalex.org/W1504465378","https://openalex.org/W1532795459","https://openalex.org/W1538774190","https://openalex.org/W1557615895","https://openalex.org/W1592721071","https://openalex.org/W1965845706","https://openalex.org/W1976080426","https://openalex.org/W1983162381","https://openalex.org/W2001442398","https://openalex.org/W2006345331","https://openalex.org/W2055842058","https://openalex.org/W2070637038","https://openalex.org/W2072581663","https://openalex.org/W2100151841","https://openalex.org/W2105519720","https://openalex.org/W2114604834","https://openalex.org/W2118053440","https://openalex.org/W2121930884","https://openalex.org/W2126223717","https://openalex.org/W2140202195","https://openalex.org/W2148074302","https://openalex.org/W2270949897","https://openalex.org/W2289743294","https://openalex.org/W6644052028","https://openalex.org/W6681856322","https://openalex.org/W6696397684"],"related_works":["https://openalex.org/W1982997428","https://openalex.org/W2044172536","https://openalex.org/W2371498377","https://openalex.org/W2370995213","https://openalex.org/W3185987145","https://openalex.org/W4366165321","https://openalex.org/W3081405802","https://openalex.org/W4287514677","https://openalex.org/W2017190659","https://openalex.org/W4282007662"],"abstract_inverted_index":{"This":[0],"paper":[1],"presents":[2],"a":[3,84,122,159,170],"miniaturized":[4],"wide-input-range":[5],"integrated":[6],"reconfigurable":[7],"three-level":[8,13],"dc-dc":[9],"voltage":[10,131,144,154],"regulator.":[11],"A":[12,54,93],"buck":[14],"converter":[15,36,91],"topology":[16],"with":[17,114,158,188],"zerovoltage":[18],"switching":[19,27,185],"(ZVS)":[20],"is":[21,62,99],"adopted":[22],"to":[23,37,64,102,140,147],"remove":[24],"the":[25,35,43,48,68,74,79,90,129,152,177,189,192,203,206],"dominant":[26],"power":[28,40,52,107,138,162,172],"loss":[29],"under":[30,176],"high-input-voltage":[31],"condition,":[32],"thereby":[33],"enabling":[34],"achieve":[38],"high":[39],"efficiency":[41,173],"in":[42,78,109,121,202],"megahertz":[44,80],"range":[45,81,87],"and":[46,82,150,182,198,205],"reduce":[47],"required":[49],"values":[50],"of":[51,106,163,174],"passives.":[53],"constant-frequency":[55],"adaptive-on-time":[56],"V":[57,124,136,149,157,180],"<sup":[58],"xmlns:mml=\"http://www.w3.org/1998/Math/MathML\"":[59],"xmlns:xlink=\"http://www.w3.org/1999/xlink\">2</sup>":[60],"control":[61],"proposed":[63,130,167,193],"not":[65],"only":[66],"regulate":[67],"output":[69,153,161],"voltage,":[70],"but":[71],"also":[72,100],"offer":[73],"flying":[75],"capacitor":[76],"self-balancing":[77],"over":[83],"wide":[85],"input":[86,143,181],"for":[88],"improving":[89],"reliability.":[92],"body":[94],"diode-based":[95],"floating":[96],"ZVS":[97,117],"detector":[98],"developed":[101],"enable":[103],"full-ZVS":[104],"operation":[105],"transistors":[108],"high-frequency":[110],"low":[111],"duty-ratio":[112],"conditions":[113],"\u22645":[115],"ns":[116],"turnon":[118],"delay.":[119],"Implemented":[120],"120":[123],"0.5":[125],"\u03bcm":[126],"CMOS":[127],"process,":[128],"regulator":[132,168,194],"uses":[133],"four":[134],"50":[135],"on-chip":[137],"nMOS":[139],"support":[141],"an":[142],"from":[145],"12":[146],"100":[148],"regulates":[151],"at":[155],"10":[156],"maximum":[160,171],"5":[164],"W.":[165],"The":[166],"achieves":[169],"90%":[175],"nominal":[178],"48":[179],"2":[183],"MHz":[184],"frequency.":[186],"Compared":[187],"state-of-the-art":[190],"counterparts,":[191],"provides":[195],"66":[196],"times":[197,200],"2.6":[199],"reductions":[201],"inductance":[204],"total":[207],"capacitance,":[208],"respectively.":[209]},"counts_by_year":[{"year":2026,"cited_by_count":2},{"year":2025,"cited_by_count":3},{"year":2024,"cited_by_count":15},{"year":2023,"cited_by_count":12},{"year":2022,"cited_by_count":8},{"year":2021,"cited_by_count":10},{"year":2020,"cited_by_count":10},{"year":2019,"cited_by_count":6},{"year":2018,"cited_by_count":5},{"year":2017,"cited_by_count":2}],"updated_date":"2026-06-19T17:40:00.097472","created_date":"2025-10-10T00:00:00"}
