{"id":"https://openalex.org/W4200400470","doi":"https://doi.org/10.1109/jbhi.2021.3136603","title":"Fundamentals of Camera-PPG Based Magnetic Resonance Imaging","display_name":"Fundamentals of Camera-PPG Based Magnetic Resonance Imaging","publication_year":2021,"publication_date":"2021-12-20","ids":{"openalex":"https://openalex.org/W4200400470","doi":"https://doi.org/10.1109/jbhi.2021.3136603","pmid":"https://pubmed.ncbi.nlm.nih.gov/34928810"},"language":"en","primary_location":{"id":"doi:10.1109/jbhi.2021.3136603","is_oa":false,"landing_page_url":"https://doi.org/10.1109/jbhi.2021.3136603","pdf_url":null,"source":{"id":"https://openalex.org/S2495854775","display_name":"IEEE Journal of Biomedical and Health Informatics","issn_l":"2168-2194","issn":["2168-2194","2168-2208"],"is_oa":false,"is_in_doaj":false,"is_core":true,"host_organization":"https://openalex.org/P4310319808","host_organization_name":"Institute of Electrical and Electronics Engineers","host_organization_lineage":["https://openalex.org/P4310319808"],"host_organization_lineage_names":["Institute of Electrical and Electronics Engineers"],"type":"journal"},"license":null,"license_id":null,"version":"publishedVersion","is_accepted":true,"is_published":true,"raw_source_name":"IEEE Journal of Biomedical and Health Informatics","raw_type":"journal-article"},"type":"article","indexed_in":["crossref","pubmed"],"open_access":{"is_oa":false,"oa_status":"closed","oa_url":null,"any_repository_has_fulltext":false},"authorships":[{"author_position":"first","author":{"id":"https://openalex.org/A5100636785","display_name":"Wenjin Wang","orcid":"https://orcid.org/0000-0001-7832-5444"},"institutions":[{"id":"https://openalex.org/I4210122849","display_name":"Philips (Netherlands)","ror":"https://ror.org/02p2bgp27","country_code":"NL","type":"company","lineage":["https://openalex.org/I4210122849"]}],"countries":["NL"],"is_corresponding":false,"raw_author_name":"Wenjin Wang","raw_affiliation_strings":["Philips Research, Eindhoven, The Netherlands"],"raw_orcid":"https://orcid.org/0000-0001-7832-5444","affiliations":[{"raw_affiliation_string":"Philips Research, Eindhoven, The Netherlands","institution_ids":["https://openalex.org/I4210122849"]}]},{"author_position":"middle","author":{"id":"https://openalex.org/A5013013142","display_name":"Steffen Wei\u00df","orcid":"https://orcid.org/0000-0003-3905-4666"},"institutions":[{"id":"https://openalex.org/I4210162505","display_name":"Philips (Germany)","ror":"https://ror.org/05san5604","country_code":"DE","type":"company","lineage":["https://openalex.org/I4210122849","https://openalex.org/I4210162505"]}],"countries":["DE"],"is_corresponding":false,"raw_author_name":"Steffen Weiss","raw_affiliation_strings":["Philips GmbH Innovative Technologies, Research Laboratories Hamburg, Hamburg, Germany"],"raw_orcid":"https://orcid.org/0000-0003-3905-4666","affiliations":[{"raw_affiliation_string":"Philips GmbH Innovative Technologies, Research Laboratories Hamburg, Hamburg, Germany","institution_ids":["https://openalex.org/I4210162505"]}]},{"author_position":"middle","author":{"id":"https://openalex.org/A5057623620","display_name":"Albertus C. den Brinker","orcid":"https://orcid.org/0000-0002-1679-7574"},"institutions":[{"id":"https://openalex.org/I4210122849","display_name":"Philips (Netherlands)","ror":"https://ror.org/02p2bgp27","country_code":"NL","type":"company","lineage":["https://openalex.org/I4210122849"]}],"countries":["NL"],"is_corresponding":false,"raw_author_name":"Albertus C. den Brinker","raw_affiliation_strings":["Philips Research, Eindhoven, The Netherlands"],"raw_orcid":"https://orcid.org/0000-0002-1679-7574","affiliations":[{"raw_affiliation_string":"Philips Research, Eindhoven, The Netherlands","institution_ids":["https://openalex.org/I4210122849"]}]},{"author_position":"middle","author":{"id":"https://openalex.org/A5002115734","display_name":"Jan Hendrik Wuelbern","orcid":"https://orcid.org/0000-0001-7805-1658"},"institutions":[{"id":"https://openalex.org/I4210162505","display_name":"Philips (Germany)","ror":"https://ror.org/05san5604","country_code":"DE","type":"company","lineage":["https://openalex.org/I4210122849","https://openalex.org/I4210162505"]}],"countries":["DE"],"is_corresponding":false,"raw_author_name":"Jan Hendrik Wuelbern","raw_affiliation_strings":["Philips GmbH Innovative Technologies, Research Laboratories Hamburg, Hamburg, Germany"],"raw_orcid":"https://orcid.org/0000-0001-7805-1658","affiliations":[{"raw_affiliation_string":"Philips GmbH Innovative Technologies, Research Laboratories Hamburg, Hamburg, Germany","institution_ids":["https://openalex.org/I4210162505"]}]},{"author_position":"middle","author":{"id":"https://openalex.org/A5061405911","display_name":"Albert Garcia i Tormo","orcid":null},"institutions":[{"id":"https://openalex.org/I4210122849","display_name":"Philips (Netherlands)","ror":"https://ror.org/02p2bgp27","country_code":"NL","type":"company","lineage":["https://openalex.org/I4210122849"]}],"countries":["NL"],"is_corresponding":false,"raw_author_name":"Albert Garcia i Tormo","raw_affiliation_strings":["Philips Research, Eindhoven, The Netherlands"],"raw_orcid":null,"affiliations":[{"raw_affiliation_string":"Philips Research, Eindhoven, The Netherlands","institution_ids":["https://openalex.org/I4210122849"]}]},{"author_position":"middle","author":{"id":"https://openalex.org/A5059775771","display_name":"Ioannis Pappous","orcid":null},"institutions":[{"id":"https://openalex.org/I4210122849","display_name":"Philips (Netherlands)","ror":"https://ror.org/02p2bgp27","country_code":"NL","type":"company","lineage":["https://openalex.org/I4210122849"]}],"countries":["NL"],"is_corresponding":false,"raw_author_name":"Ioannis Pappous","raw_affiliation_strings":["Philips Innovation Services, Eindhoven, The Netherlands"],"raw_orcid":null,"affiliations":[{"raw_affiliation_string":"Philips Innovation Services, Eindhoven, The Netherlands","institution_ids":["https://openalex.org/I4210122849"]}]},{"author_position":"last","author":{"id":"https://openalex.org/A5048067697","display_name":"Julien S\u00e9n\u00e9gas","orcid":null},"institutions":[{"id":"https://openalex.org/I4210162505","display_name":"Philips (Germany)","ror":"https://ror.org/05san5604","country_code":"DE","type":"company","lineage":["https://openalex.org/I4210122849","https://openalex.org/I4210162505"]}],"countries":["DE"],"is_corresponding":false,"raw_author_name":"Julien Senegas","raw_affiliation_strings":["Philips GmbH Innovative Technologies, Research Laboratories Hamburg, Hamburg, Germany"],"raw_orcid":null,"affiliations":[{"raw_affiliation_string":"Philips GmbH Innovative Technologies, Research Laboratories Hamburg, Hamburg, Germany","institution_ids":["https://openalex.org/I4210162505"]}]}],"institutions":[],"countries_distinct_count":2,"institutions_distinct_count":2,"corresponding_author_ids":[],"corresponding_institution_ids":[],"apc_list":null,"apc_paid":null,"fwci":0.4137,"has_fulltext":false,"cited_by_count":12,"citation_normalized_percentile":{"value":0.57460528,"is_in_top_1_percent":false,"is_in_top_10_percent":false},"cited_by_percentile_year":{"min":89,"max":98},"biblio":{"volume":"26","issue":"9","first_page":"4378","last_page":"4389"},"is_retracted":false,"is_paratext":false,"is_xpac":false,"primary_topic":{"id":"https://openalex.org/T11196","display_name":"Non-Invasive Vital Sign Monitoring","score":0.9998999834060669,"subfield":{"id":"https://openalex.org/subfields/2204","display_name":"Biomedical Engineering"},"field":{"id":"https://openalex.org/fields/22","display_name":"Engineering"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}},"topics":[{"id":"https://openalex.org/T11196","display_name":"Non-Invasive Vital Sign Monitoring","score":0.9998999834060669,"subfield":{"id":"https://openalex.org/subfields/2204","display_name":"Biomedical Engineering"},"field":{"id":"https://openalex.org/fields/22","display_name":"Engineering"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}},{"id":"https://openalex.org/T11700","display_name":"Hemodynamic Monitoring and Therapy","score":0.9988999962806702,"subfield":{"id":"https://openalex.org/subfields/2746","display_name":"Surgery"},"field":{"id":"https://openalex.org/fields/27","display_name":"Medicine"},"domain":{"id":"https://openalex.org/domains/4","display_name":"Health Sciences"}},{"id":"https://openalex.org/T10745","display_name":"Heart Rate Variability and Autonomic Control","score":0.9975000023841858,"subfield":{"id":"https://openalex.org/subfields/2705","display_name":"Cardiology and Cardiovascular Medicine"},"field":{"id":"https://openalex.org/fields/27","display_name":"Medicine"},"domain":{"id":"https://openalex.org/domains/4","display_name":"Health Sciences"}}],"keywords":[{"id":"https://openalex.org/keywords/photoplethysmogram","display_name":"Photoplethysmogram","score":0.7618554830551147},{"id":"https://openalex.org/keywords/computer-science","display_name":"Computer science","score":0.6243621706962585},{"id":"https://openalex.org/keywords/magnetic-resonance-imaging","display_name":"Magnetic resonance imaging","score":0.6237231492996216},{"id":"https://openalex.org/keywords/computer-vision","display_name":"Computer vision","score":0.6054657697677612},{"id":"https://openalex.org/keywords/artificial-intelligence","display_name":"Artificial intelligence","score":0.565798282623291},{"id":"https://openalex.org/keywords/signal","display_name":"SIGNAL (programming language)","score":0.5297912955284119},{"id":"https://openalex.org/keywords/data-acquisition","display_name":"Data acquisition","score":0.44070738554000854},{"id":"https://openalex.org/keywords/workflow","display_name":"Workflow","score":0.4278082549571991},{"id":"https://openalex.org/keywords/electrocardiography","display_name":"Electrocardiography","score":0.4265219569206238},{"id":"https://openalex.org/keywords/biomedical-engineering","display_name":"Biomedical engineering","score":0.3932889699935913},{"id":"https://openalex.org/keywords/medicine","display_name":"Medicine","score":0.2314450442790985},{"id":"https://openalex.org/keywords/radiology","display_name":"Radiology","score":0.1483798325061798},{"id":"https://openalex.org/keywords/cardiology","display_name":"Cardiology","score":0.10524269938468933}],"concepts":[{"id":"https://openalex.org/C116390426","wikidata":"https://www.wikidata.org/wiki/Q7187885","display_name":"Photoplethysmogram","level":3,"score":0.7618554830551147},{"id":"https://openalex.org/C41008148","wikidata":"https://www.wikidata.org/wiki/Q21198","display_name":"Computer science","level":0,"score":0.6243621706962585},{"id":"https://openalex.org/C143409427","wikidata":"https://www.wikidata.org/wiki/Q161238","display_name":"Magnetic resonance imaging","level":2,"score":0.6237231492996216},{"id":"https://openalex.org/C31972630","wikidata":"https://www.wikidata.org/wiki/Q844240","display_name":"Computer vision","level":1,"score":0.6054657697677612},{"id":"https://openalex.org/C154945302","wikidata":"https://www.wikidata.org/wiki/Q11660","display_name":"Artificial intelligence","level":1,"score":0.565798282623291},{"id":"https://openalex.org/C2779843651","wikidata":"https://www.wikidata.org/wiki/Q7390335","display_name":"SIGNAL (programming language)","level":2,"score":0.5297912955284119},{"id":"https://openalex.org/C163985040","wikidata":"https://www.wikidata.org/wiki/Q1172399","display_name":"Data acquisition","level":2,"score":0.44070738554000854},{"id":"https://openalex.org/C177212765","wikidata":"https://www.wikidata.org/wiki/Q627335","display_name":"Workflow","level":2,"score":0.4278082549571991},{"id":"https://openalex.org/C2780040984","wikidata":"https://www.wikidata.org/wiki/Q79785","display_name":"Electrocardiography","level":2,"score":0.4265219569206238},{"id":"https://openalex.org/C136229726","wikidata":"https://www.wikidata.org/wiki/Q327092","display_name":"Biomedical engineering","level":1,"score":0.3932889699935913},{"id":"https://openalex.org/C71924100","wikidata":"https://www.wikidata.org/wiki/Q11190","display_name":"Medicine","level":0,"score":0.2314450442790985},{"id":"https://openalex.org/C126838900","wikidata":"https://www.wikidata.org/wiki/Q77604","display_name":"Radiology","level":1,"score":0.1483798325061798},{"id":"https://openalex.org/C164705383","wikidata":"https://www.wikidata.org/wiki/Q10379","display_name":"Cardiology","level":1,"score":0.10524269938468933},{"id":"https://openalex.org/C111919701","wikidata":"https://www.wikidata.org/wiki/Q9135","display_name":"Operating system","level":1,"score":0.0},{"id":"https://openalex.org/C77088390","wikidata":"https://www.wikidata.org/wiki/Q8513","display_name":"Database","level":1,"score":0.0},{"id":"https://openalex.org/C199360897","wikidata":"https://www.wikidata.org/wiki/Q9143","display_name":"Programming language","level":1,"score":0.0},{"id":"https://openalex.org/C106131492","wikidata":"https://www.wikidata.org/wiki/Q3072260","display_name":"Filter (signal processing)","level":2,"score":0.0}],"mesh":[{"descriptor_ui":"D004562","descriptor_name":"Electrocardiography","qualifier_ui":"Q000379","qualifier_name":"methods","is_major_topic":true},{"descriptor_ui":"D004562","descriptor_name":"Electrocardiography","qualifier_ui":"Q000379","qualifier_name":"methods","is_major_topic":true},{"descriptor_ui":"D004562","descriptor_name":"Electrocardiography","qualifier_ui":"Q000379","qualifier_name":"methods","is_major_topic":true},{"descriptor_ui":"D006321","descriptor_name":"Heart","qualifier_ui":null,"qualifier_name":null,"is_major_topic":false},{"descriptor_ui":"D006321","descriptor_name":"Heart","qualifier_ui":null,"qualifier_name":null,"is_major_topic":false},{"descriptor_ui":"D006321","descriptor_name":"Heart","qualifier_ui":null,"qualifier_name":null,"is_major_topic":false},{"descriptor_ui":"D006339","descriptor_name":"Heart Rate","qualifier_ui":null,"qualifier_name":null,"is_major_topic":false},{"descriptor_ui":"D006339","descriptor_name":"Heart Rate","qualifier_ui":null,"qualifier_name":null,"is_major_topic":false},{"descriptor_ui":"D006339","descriptor_name":"Heart Rate","qualifier_ui":null,"qualifier_name":null,"is_major_topic":false},{"descriptor_ui":"D006801","descriptor_name":"Humans","qualifier_ui":null,"qualifier_name":null,"is_major_topic":false},{"descriptor_ui":"D006801","descriptor_name":"Humans","qualifier_ui":null,"qualifier_name":null,"is_major_topic":false},{"descriptor_ui":"D006801","descriptor_name":"Humans","qualifier_ui":null,"qualifier_name":null,"is_major_topic":false},{"descriptor_ui":"D008279","descriptor_name":"Magnetic Resonance Imaging","qualifier_ui":null,"qualifier_name":null,"is_major_topic":false},{"descriptor_ui":"D008279","descriptor_name":"Magnetic Resonance Imaging","qualifier_ui":null,"qualifier_name":null,"is_major_topic":false},{"descriptor_ui":"D008279","descriptor_name":"Magnetic Resonance Imaging","qualifier_ui":null,"qualifier_name":null,"is_major_topic":false},{"descriptor_ui":"D010092","descriptor_name":"Oximetry","qualifier_ui":null,"qualifier_name":null,"is_major_topic":false},{"descriptor_ui":"D010092","descriptor_name":"Oximetry","qualifier_ui":null,"qualifier_name":null,"is_major_topic":false},{"descriptor_ui":"D010092","descriptor_name":"Oximetry","qualifier_ui":null,"qualifier_name":null,"is_major_topic":false},{"descriptor_ui":"D012815","descriptor_name":"Signal Processing, Computer-Assisted","qualifier_ui":null,"qualifier_name":null,"is_major_topic":false},{"descriptor_ui":"D012815","descriptor_name":"Signal Processing, Computer-Assisted","qualifier_ui":null,"qualifier_name":null,"is_major_topic":false},{"descriptor_ui":"D012815","descriptor_name":"Signal Processing, Computer-Assisted","qualifier_ui":null,"qualifier_name":null,"is_major_topic":false},{"descriptor_ui":"D017156","descriptor_name":"Photoplethysmography","qualifier_ui":"Q000379","qualifier_name":"methods","is_major_topic":true},{"descriptor_ui":"D017156","descriptor_name":"Photoplethysmography","qualifier_ui":"Q000379","qualifier_name":"methods","is_major_topic":true},{"descriptor_ui":"D017156","descriptor_name":"Photoplethysmography","qualifier_ui":"Q000379","qualifier_name":"methods","is_major_topic":true}],"locations_count":2,"locations":[{"id":"doi:10.1109/jbhi.2021.3136603","is_oa":false,"landing_page_url":"https://doi.org/10.1109/jbhi.2021.3136603","pdf_url":null,"source":{"id":"https://openalex.org/S2495854775","display_name":"IEEE Journal of Biomedical and Health Informatics","issn_l":"2168-2194","issn":["2168-2194","2168-2208"],"is_oa":false,"is_in_doaj":false,"is_core":true,"host_organization":"https://openalex.org/P4310319808","host_organization_name":"Institute of Electrical and Electronics Engineers","host_organization_lineage":["https://openalex.org/P4310319808"],"host_organization_lineage_names":["Institute of Electrical and Electronics Engineers"],"type":"journal"},"license":null,"license_id":null,"version":"publishedVersion","is_accepted":true,"is_published":true,"raw_source_name":"IEEE Journal of Biomedical and Health Informatics","raw_type":"journal-article"},{"id":"pmid:34928810","is_oa":false,"landing_page_url":"https://pubmed.ncbi.nlm.nih.gov/34928810","pdf_url":null,"source":{"id":"https://openalex.org/S4306525036","display_name":"PubMed","issn_l":null,"issn":null,"is_oa":false,"is_in_doaj":false,"is_core":false,"host_organization":"https://openalex.org/I1299303238","host_organization_name":"National Institutes of Health","host_organization_lineage":["https://openalex.org/I1299303238"],"host_organization_lineage_names":[],"type":"repository"},"license":null,"license_id":null,"version":"publishedVersion","is_accepted":true,"is_published":true,"raw_source_name":"IEEE journal of biomedical and health informatics","raw_type":null}],"best_oa_location":null,"sustainable_development_goals":[],"awards":[],"funders":[],"has_content":{"pdf":false,"grobid_xml":false},"content_urls":null,"referenced_works_count":40,"referenced_works":["https://openalex.org/W106785357","https://openalex.org/W328151516","https://openalex.org/W1503272692","https://openalex.org/W1790303963","https://openalex.org/W1948432195","https://openalex.org/W1984026713","https://openalex.org/W1984418993","https://openalex.org/W1992859884","https://openalex.org/W2033933262","https://openalex.org/W2044935899","https://openalex.org/W2069692225","https://openalex.org/W2072227544","https://openalex.org/W2077564187","https://openalex.org/W2087386698","https://openalex.org/W2092654571","https://openalex.org/W2098833891","https://openalex.org/W2109722856","https://openalex.org/W2115134618","https://openalex.org/W2117861493","https://openalex.org/W2147966418","https://openalex.org/W2166197001","https://openalex.org/W2170113214","https://openalex.org/W2171246071","https://openalex.org/W2171700197","https://openalex.org/W2322136812","https://openalex.org/W2520509592","https://openalex.org/W2555598182","https://openalex.org/W2594582590","https://openalex.org/W2606820947","https://openalex.org/W2731020442","https://openalex.org/W2773107119","https://openalex.org/W2796199091","https://openalex.org/W2901729966","https://openalex.org/W2963341006","https://openalex.org/W2970238056","https://openalex.org/W2981724183","https://openalex.org/W2982449604","https://openalex.org/W3006655380","https://openalex.org/W6685182997","https://openalex.org/W6746224122"],"related_works":["https://openalex.org/W1891287906","https://openalex.org/W1969923398","https://openalex.org/W2772917594","https://openalex.org/W2081035100","https://openalex.org/W2389727891","https://openalex.org/W2748921485","https://openalex.org/W2092235563","https://openalex.org/W3009030250","https://openalex.org/W407996297","https://openalex.org/W1992789490"],"abstract_inverted_index":{"In":[0],"Magnetic":[1,54],"Resonance":[2,55],"Imaging":[3],"(MRI),":[4],"cardiac":[5,12,84],"triggering":[6],"that":[7],"synchronizes":[8],"data":[9],"acquisition":[10,35],"with":[11,121],"contractions":[13],"is":[14,23,118],"an":[15,64,137],"essential":[16],"technique":[17],"for":[18,136],"acquiring":[19],"high-quality":[20],"images.":[21],"Triggering":[22],"typically":[24],"based":[25],"on":[26],"the":[27,68,78,106,109,115,125],"Electrocardiogram":[28],"(ECG)":[29],"signal":[30,107],"(e.g.":[31],"R-peak).":[32],"Since":[33],"ECG":[34,44,116],"involves":[36],"extra":[37],"workflow":[38],"steps":[39],"like":[40],"electrode":[41],"placement":[42],"and":[43,80,91,108],"signals":[45],"are":[46],"usually":[47],"disturbed":[48],"by":[49],"magnetic":[50],"fields":[51],"in":[52,130],"high":[53],"(MR)":[56],"systems,":[57],"we":[58],"explored":[59],"camera-based":[60,83,99],"photoplethysmography":[61],"(PPG)":[62],"as":[63],"alternative.":[65],"We":[66],"used":[67],"in-bore":[69],"camera":[70,92,123],"of":[71,82,105],"a":[72,102,122,134],"clinical":[73],"MR":[74],"system":[75],"to":[76,97,114],"investigate":[77],"feasibility":[79],"challenges":[81],"triggering.":[85],"Data":[86],"from":[87],"ECG,":[88],"finger":[89],"oximeter":[90],"were":[93],"synchronously":[94],"collected.":[95],"Compared":[96],"finger-PPG,":[98],"PPG":[100,110],"provides":[101],"higher":[103],"availability":[104],"marker":[111],"delay":[112],"relative":[113],"R-peak":[117],"considerably":[119],"less":[120],"monitoring":[124],"forehead.":[126],"The":[127],"insights":[128],"obtained":[129],"this":[131],"study":[132],"provide":[133],"basis":[135],"envisioned":[138],"system-design":[139],"phase.":[140]},"counts_by_year":[{"year":2026,"cited_by_count":2},{"year":2025,"cited_by_count":5},{"year":2024,"cited_by_count":4},{"year":2023,"cited_by_count":1}],"updated_date":"2025-11-06T03:46:38.306776","created_date":"2025-10-10T00:00:00"}
