{"id":"https://openalex.org/W2738831641","doi":"https://doi.org/10.1109/iwcmc.2017.7986462","title":"Explicit non-congestion notification: A new AQM approach for TCP networks","display_name":"Explicit non-congestion notification: A new AQM approach for TCP networks","publication_year":2017,"publication_date":"2017-06-01","ids":{"openalex":"https://openalex.org/W2738831641","doi":"https://doi.org/10.1109/iwcmc.2017.7986462","mag":"2738831641"},"language":"en","primary_location":{"id":"doi:10.1109/iwcmc.2017.7986462","is_oa":false,"landing_page_url":"https://doi.org/10.1109/iwcmc.2017.7986462","pdf_url":null,"source":null,"license":null,"license_id":null,"version":"publishedVersion","is_accepted":true,"is_published":true,"raw_source_name":"2017 13th International Wireless Communications and Mobile Computing Conference (IWCMC)","raw_type":"proceedings-article"},"type":"article","indexed_in":["crossref"],"open_access":{"is_oa":false,"oa_status":"closed","oa_url":null,"any_repository_has_fulltext":false},"authorships":[{"author_position":"first","author":{"id":"https://openalex.org/A5054037934","display_name":"Luciano Mauro Arley Sup","orcid":null},"institutions":[{"id":"https://openalex.org/I150729083","display_name":"Universidade de Bras\u00edlia","ror":"https://ror.org/02xfp8v59","country_code":"BR","type":"education","lineage":["https://openalex.org/I150729083"]}],"countries":["BR"],"is_corresponding":true,"raw_author_name":"Luciano Mauro Arley Sup","raw_affiliation_strings":["Dept. of Electrical Engineering, University of Bras&#x00ED;lia (UnB), DF 70910-900, Brazil","Dept. of Electrical Engineering, University of Bras\u00edlia (UnB), DF 70910-900, Brazil"],"affiliations":[{"raw_affiliation_string":"Dept. of Electrical Engineering, University of Bras&#x00ED;lia (UnB), DF 70910-900, Brazil","institution_ids":["https://openalex.org/I150729083"]},{"raw_affiliation_string":"Dept. of Electrical Engineering, University of Bras\u00edlia (UnB), DF 70910-900, Brazil","institution_ids":["https://openalex.org/I150729083"]}]},{"author_position":"middle","author":{"id":"https://openalex.org/A5042588839","display_name":"Renato M. de Moraes","orcid":"https://orcid.org/0000-0002-3437-7004"},"institutions":[{"id":"https://openalex.org/I25112270","display_name":"Universidade Federal de Pernambuco","ror":"https://ror.org/047908t24","country_code":"BR","type":"education","lineage":["https://openalex.org/I25112270"]}],"countries":["BR"],"is_corresponding":false,"raw_author_name":"Renato Mariz de Moraes","raw_affiliation_strings":["Informatics Center, Federal University of Pernambuco, Recife, 50740-560, Brazil"],"affiliations":[{"raw_affiliation_string":"Informatics Center, Federal University of Pernambuco, Recife, 50740-560, Brazil","institution_ids":["https://openalex.org/I25112270"]}]},{"author_position":"last","author":{"id":"https://openalex.org/A5049516094","display_name":"Adolfo Bauchspiess","orcid":"https://orcid.org/0000-0002-4512-4299"},"institutions":[{"id":"https://openalex.org/I150729083","display_name":"Universidade de Bras\u00edlia","ror":"https://ror.org/02xfp8v59","country_code":"BR","type":"education","lineage":["https://openalex.org/I150729083"]}],"countries":["BR"],"is_corresponding":false,"raw_author_name":"Adolfo Bauchspiess","raw_affiliation_strings":["Dept. of Electrical Engineering, University of Bras&#x00ED;lia (UnB), DF 70910-900, Brazil","Dept. of Electrical Engineering, University of Bras\u00edlia (UnB), DF 70910-900, Brazil"],"affiliations":[{"raw_affiliation_string":"Dept. of Electrical Engineering, University of Bras&#x00ED;lia (UnB), DF 70910-900, Brazil","institution_ids":["https://openalex.org/I150729083"]},{"raw_affiliation_string":"Dept. of Electrical Engineering, University of Bras\u00edlia (UnB), DF 70910-900, Brazil","institution_ids":["https://openalex.org/I150729083"]}]}],"institutions":[],"countries_distinct_count":1,"institutions_distinct_count":3,"corresponding_author_ids":["https://openalex.org/A5054037934"],"corresponding_institution_ids":["https://openalex.org/I150729083"],"apc_list":null,"apc_paid":null,"fwci":0.4144,"has_fulltext":false,"cited_by_count":7,"citation_normalized_percentile":{"value":0.65466896,"is_in_top_1_percent":false,"is_in_top_10_percent":false},"cited_by_percentile_year":{"min":89,"max":97},"biblio":{"volume":null,"issue":null,"first_page":"1239","last_page":"1244"},"is_retracted":false,"is_paratext":false,"is_xpac":false,"primary_topic":{"id":"https://openalex.org/T10138","display_name":"Network Traffic and Congestion Control","score":0.9998999834060669,"subfield":{"id":"https://openalex.org/subfields/1705","display_name":"Computer Networks and Communications"},"field":{"id":"https://openalex.org/fields/17","display_name":"Computer Science"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}},"topics":[{"id":"https://openalex.org/T10138","display_name":"Network Traffic and Congestion Control","score":0.9998999834060669,"subfield":{"id":"https://openalex.org/subfields/1705","display_name":"Computer Networks and Communications"},"field":{"id":"https://openalex.org/fields/17","display_name":"Computer Science"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}},{"id":"https://openalex.org/T10714","display_name":"Software-Defined Networks and 5G","score":0.9986000061035156,"subfield":{"id":"https://openalex.org/subfields/1705","display_name":"Computer Networks and Communications"},"field":{"id":"https://openalex.org/fields/17","display_name":"Computer Science"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}},{"id":"https://openalex.org/T11158","display_name":"Wireless Networks and Protocols","score":0.9980000257492065,"subfield":{"id":"https://openalex.org/subfields/1705","display_name":"Computer Networks and Communications"},"field":{"id":"https://openalex.org/fields/17","display_name":"Computer Science"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}}],"keywords":[{"id":"https://openalex.org/keywords/active-queue-management","display_name":"Active queue management","score":0.9105556607246399},{"id":"https://openalex.org/keywords/computer-science","display_name":"Computer science","score":0.7093170881271362},{"id":"https://openalex.org/keywords/computer-network","display_name":"Computer network","score":0.7091251611709595},{"id":"https://openalex.org/keywords/network-congestion","display_name":"Network congestion","score":0.5898827314376831},{"id":"https://openalex.org/keywords/tcp-tuning","display_name":"TCP tuning","score":0.5697923302650452},{"id":"https://openalex.org/keywords/tcp-friendly-rate-control","display_name":"TCP Friendly Rate Control","score":0.4732799232006073},{"id":"https://openalex.org/keywords/network-packet","display_name":"Network packet","score":0.0583283007144928}],"concepts":[{"id":"https://openalex.org/C34793927","wikidata":"https://www.wikidata.org/wiki/Q583367","display_name":"Active queue management","level":4,"score":0.9105556607246399},{"id":"https://openalex.org/C41008148","wikidata":"https://www.wikidata.org/wiki/Q21198","display_name":"Computer science","level":0,"score":0.7093170881271362},{"id":"https://openalex.org/C31258907","wikidata":"https://www.wikidata.org/wiki/Q1301371","display_name":"Computer network","level":1,"score":0.7091251611709595},{"id":"https://openalex.org/C195563490","wikidata":"https://www.wikidata.org/wiki/Q180368","display_name":"Network congestion","level":3,"score":0.5898827314376831},{"id":"https://openalex.org/C120837960","wikidata":"https://www.wikidata.org/wiki/Q7669763","display_name":"TCP tuning","level":4,"score":0.5697923302650452},{"id":"https://openalex.org/C30838235","wikidata":"https://www.wikidata.org/wiki/Q7669749","display_name":"TCP Friendly Rate Control","level":4,"score":0.4732799232006073},{"id":"https://openalex.org/C158379750","wikidata":"https://www.wikidata.org/wiki/Q214111","display_name":"Network packet","level":2,"score":0.0583283007144928}],"mesh":[],"locations_count":1,"locations":[{"id":"doi:10.1109/iwcmc.2017.7986462","is_oa":false,"landing_page_url":"https://doi.org/10.1109/iwcmc.2017.7986462","pdf_url":null,"source":null,"license":null,"license_id":null,"version":"publishedVersion","is_accepted":true,"is_published":true,"raw_source_name":"2017 13th International Wireless Communications and Mobile Computing Conference (IWCMC)","raw_type":"proceedings-article"}],"best_oa_location":null,"sustainable_development_goals":[],"awards":[],"funders":[],"has_content":{"grobid_xml":false,"pdf":false},"content_urls":null,"referenced_works_count":15,"referenced_works":["https://openalex.org/W1545601271","https://openalex.org/W1581570232","https://openalex.org/W1630733292","https://openalex.org/W1969306158","https://openalex.org/W1970131865","https://openalex.org/W1989035469","https://openalex.org/W1995941149","https://openalex.org/W2081306301","https://openalex.org/W2095822637","https://openalex.org/W2113852631","https://openalex.org/W2158733823","https://openalex.org/W2159433799","https://openalex.org/W3160060809","https://openalex.org/W4234789332","https://openalex.org/W6636933019"],"related_works":["https://openalex.org/W2892220642","https://openalex.org/W2742417751","https://openalex.org/W2361487389","https://openalex.org/W1631038856","https://openalex.org/W2382744343","https://openalex.org/W1007877092","https://openalex.org/W2390377932","https://openalex.org/W4389097828","https://openalex.org/W2006149417","https://openalex.org/W2391875810"],"abstract_inverted_index":{"This":[0],"paper":[1],"presents":[2],"a":[3],"new":[4],"approach":[5],"for":[6,45],"Active":[7],"Queue":[8],"Management":[9],"(AQM)":[10],"techniques":[11,40,92],"and":[12,32,43,47,57,63,74,90,98,108],"TCP":[13,48,61],"networks":[14],"called":[15],"Explicit":[16],"Non-Congestion":[17],"Notification":[18],"(ENCN)":[19],"whose":[20],"performance":[21],"is":[22],"compared":[23],"with":[24,49],"Random":[25],"Early":[26],"Detection":[27],"(RED),":[28],"Controlled":[29],"Delay":[30],"(CoDel),":[31],"Proportional":[33],"Integral":[34],"controller":[35],"Enhanced":[36],"(PIE)":[37],"schemes.":[38],"The":[39],"were":[41,67],"modeled":[42],"evaluated":[44],"TCP-Reno":[46],"selective":[50],"acknowledgment":[51],"(Sack)":[52],"protocols.":[53],"In":[54],"addition,":[55],"modeling":[56],"simulation":[58],"of":[59,71,95],"the":[60,64,79],"network":[62,104],"AQM":[65],"schemes":[66],"attained":[68],"through":[69],"formalities":[70],"discrete":[72],"event":[73],"hybrid":[75],"automata":[76],"systems":[77],"using":[78],"UPPAAL":[80],"tool.":[81],"Simulation":[82],"results":[83],"show":[84],"that":[85],"ENCN":[86],"outperforms":[87],"RED,":[88],"CoDel,":[89],"PIE":[91],"in":[93,102],"terms":[94],"throughput,":[96],"fairness,":[97],"queue":[99],"length":[100],"stability":[101],"benchmark":[103],"topologies":[105],"like":[106],"daisy-chain":[107],"dumbbell":[109],"scenarios.":[110]},"counts_by_year":[{"year":2023,"cited_by_count":4},{"year":2022,"cited_by_count":1},{"year":2019,"cited_by_count":1},{"year":2018,"cited_by_count":1}],"updated_date":"2025-11-06T03:46:38.306776","created_date":"2025-10-10T00:00:00"}
