{"id":"https://openalex.org/W2523890703","doi":"https://doi.org/10.1109/iwcmc.2016.7577065","title":"A power allocation technique for fairness and enhanced energy efficiency in future networks","display_name":"A power allocation technique for fairness and enhanced energy efficiency in future networks","publication_year":2016,"publication_date":"2016-09-01","ids":{"openalex":"https://openalex.org/W2523890703","doi":"https://doi.org/10.1109/iwcmc.2016.7577065","mag":"2523890703"},"language":"en","primary_location":{"id":"doi:10.1109/iwcmc.2016.7577065","is_oa":false,"landing_page_url":"https://doi.org/10.1109/iwcmc.2016.7577065","pdf_url":null,"source":null,"license":null,"license_id":null,"version":"publishedVersion","is_accepted":true,"is_published":true,"raw_source_name":"2016 International Wireless Communications and Mobile Computing Conference (IWCMC)","raw_type":"proceedings-article"},"type":"article","indexed_in":["crossref"],"open_access":{"is_oa":false,"oa_status":"closed","oa_url":null,"any_repository_has_fulltext":false},"authorships":[{"author_position":"first","author":{"id":"https://openalex.org/A5013756597","display_name":"Hanifa Nabuuma","orcid":null},"institutions":[{"id":"https://openalex.org/I28407311","display_name":"University of Manchester","ror":"https://ror.org/027m9bs27","country_code":"GB","type":"education","lineage":["https://openalex.org/I28407311"]}],"countries":["GB"],"is_corresponding":true,"raw_author_name":"Hanifa Nabuuma","raw_affiliation_strings":["School of Electrical and Electronic Engineering, The University of Manchester, Manchester, UK"],"affiliations":[{"raw_affiliation_string":"School of Electrical and Electronic Engineering, The University of Manchester, Manchester, UK","institution_ids":["https://openalex.org/I28407311"]}]},{"author_position":"middle","author":{"id":"https://openalex.org/A5002248410","display_name":"Emad Alsusa","orcid":"https://orcid.org/0000-0002-7724-2636"},"institutions":[{"id":"https://openalex.org/I28407311","display_name":"University of Manchester","ror":"https://ror.org/027m9bs27","country_code":"GB","type":"education","lineage":["https://openalex.org/I28407311"]}],"countries":["GB"],"is_corresponding":false,"raw_author_name":"Emad Alsusa","raw_affiliation_strings":["School of Electrical and Electronic Engineering, The University of Manchester, Manchester, UK"],"affiliations":[{"raw_affiliation_string":"School of Electrical and Electronic Engineering, The University of Manchester, Manchester, UK","institution_ids":["https://openalex.org/I28407311"]}]},{"author_position":"middle","author":{"id":"https://openalex.org/A5006967605","display_name":"Wahyu Pramudito","orcid":null},"institutions":[{"id":"https://openalex.org/I28407311","display_name":"University of Manchester","ror":"https://ror.org/027m9bs27","country_code":"GB","type":"education","lineage":["https://openalex.org/I28407311"]}],"countries":["GB"],"is_corresponding":false,"raw_author_name":"Wahyu Pramudito","raw_affiliation_strings":["School of Electrical and Electronic Engineering, The University of Manchester, Manchester, UK"],"affiliations":[{"raw_affiliation_string":"School of Electrical and Electronic Engineering, The University of Manchester, Manchester, UK","institution_ids":["https://openalex.org/I28407311"]}]},{"author_position":"last","author":{"id":"https://openalex.org/A5016435044","display_name":"Mohammed W. Baidas","orcid":"https://orcid.org/0000-0002-0536-3623"},"institutions":[{"id":"https://openalex.org/I36721946","display_name":"Kuwait University","ror":"https://ror.org/021e5j056","country_code":"KW","type":"education","lineage":["https://openalex.org/I36721946"]}],"countries":["KW"],"is_corresponding":false,"raw_author_name":"Mohammed W. Baidas","raw_affiliation_strings":["Electrical Engineering Department, Kuwait University, Kuwait"],"affiliations":[{"raw_affiliation_string":"Electrical Engineering Department, Kuwait University, Kuwait","institution_ids":["https://openalex.org/I36721946"]}]}],"institutions":[],"countries_distinct_count":2,"institutions_distinct_count":4,"corresponding_author_ids":["https://openalex.org/A5013756597"],"corresponding_institution_ids":["https://openalex.org/I28407311"],"apc_list":null,"apc_paid":null,"fwci":0.0,"has_fulltext":false,"cited_by_count":0,"citation_normalized_percentile":{"value":0.09308289,"is_in_top_1_percent":false,"is_in_top_10_percent":false},"cited_by_percentile_year":null,"biblio":{"volume":null,"issue":null,"first_page":"244","last_page":"249"},"is_retracted":false,"is_paratext":false,"is_xpac":false,"primary_topic":{"id":"https://openalex.org/T10148","display_name":"Advanced MIMO Systems Optimization","score":1.0,"subfield":{"id":"https://openalex.org/subfields/2208","display_name":"Electrical and Electronic Engineering"},"field":{"id":"https://openalex.org/fields/22","display_name":"Engineering"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}},"topics":[{"id":"https://openalex.org/T10148","display_name":"Advanced MIMO Systems Optimization","score":1.0,"subfield":{"id":"https://openalex.org/subfields/2208","display_name":"Electrical and Electronic Engineering"},"field":{"id":"https://openalex.org/fields/22","display_name":"Engineering"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}},{"id":"https://openalex.org/T11409","display_name":"Advanced Wireless Network Optimization","score":0.9998999834060669,"subfield":{"id":"https://openalex.org/subfields/2208","display_name":"Electrical and Electronic Engineering"},"field":{"id":"https://openalex.org/fields/22","display_name":"Engineering"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}},{"id":"https://openalex.org/T10796","display_name":"Cooperative Communication and Network Coding","score":0.9993000030517578,"subfield":{"id":"https://openalex.org/subfields/1705","display_name":"Computer Networks and Communications"},"field":{"id":"https://openalex.org/fields/17","display_name":"Computer Science"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}}],"keywords":[{"id":"https://openalex.org/keywords/max-min-fairness","display_name":"Max-min fairness","score":0.7432681322097778},{"id":"https://openalex.org/keywords/computer-science","display_name":"Computer science","score":0.7337504625320435},{"id":"https://openalex.org/keywords/resource-allocation","display_name":"Resource allocation","score":0.7263222932815552},{"id":"https://openalex.org/keywords/block","display_name":"Block (permutation group theory)","score":0.5781490802764893},{"id":"https://openalex.org/keywords/power","display_name":"Power (physics)","score":0.5710248351097107},{"id":"https://openalex.org/keywords/mathematical-optimization","display_name":"Mathematical optimization","score":0.49970030784606934},{"id":"https://openalex.org/keywords/resource-management","display_name":"Resource management (computing)","score":0.465016633272171},{"id":"https://openalex.org/keywords/efficient-energy-use","display_name":"Efficient energy use","score":0.46182045340538025},{"id":"https://openalex.org/keywords/resource","display_name":"Resource (disambiguation)","score":0.44393259286880493},{"id":"https://openalex.org/keywords/iterative-method","display_name":"Iterative method","score":0.43033742904663086},{"id":"https://openalex.org/keywords/energy","display_name":"Energy (signal processing)","score":0.4276278018951416},{"id":"https://openalex.org/keywords/transmitter-power-output","display_name":"Transmitter power output","score":0.4264177083969116},{"id":"https://openalex.org/keywords/algorithm","display_name":"Algorithm","score":0.17303696274757385},{"id":"https://openalex.org/keywords/computer-network","display_name":"Computer network","score":0.16375195980072021},{"id":"https://openalex.org/keywords/mathematics","display_name":"Mathematics","score":0.1185506284236908},{"id":"https://openalex.org/keywords/engineering","display_name":"Engineering","score":0.09120124578475952},{"id":"https://openalex.org/keywords/transmitter","display_name":"Transmitter","score":0.07574418187141418},{"id":"https://openalex.org/keywords/electrical-engineering","display_name":"Electrical engineering","score":0.06830480694770813},{"id":"https://openalex.org/keywords/statistics","display_name":"Statistics","score":0.06591606140136719},{"id":"https://openalex.org/keywords/channel","display_name":"Channel (broadcasting)","score":0.05701223015785217}],"concepts":[{"id":"https://openalex.org/C177972170","wikidata":"https://www.wikidata.org/wiki/Q17097315","display_name":"Max-min fairness","level":3,"score":0.7432681322097778},{"id":"https://openalex.org/C41008148","wikidata":"https://www.wikidata.org/wiki/Q21198","display_name":"Computer science","level":0,"score":0.7337504625320435},{"id":"https://openalex.org/C29202148","wikidata":"https://www.wikidata.org/wiki/Q287260","display_name":"Resource allocation","level":2,"score":0.7263222932815552},{"id":"https://openalex.org/C2777210771","wikidata":"https://www.wikidata.org/wiki/Q4927124","display_name":"Block (permutation group theory)","level":2,"score":0.5781490802764893},{"id":"https://openalex.org/C163258240","wikidata":"https://www.wikidata.org/wiki/Q25342","display_name":"Power (physics)","level":2,"score":0.5710248351097107},{"id":"https://openalex.org/C126255220","wikidata":"https://www.wikidata.org/wiki/Q141495","display_name":"Mathematical optimization","level":1,"score":0.49970030784606934},{"id":"https://openalex.org/C2780609101","wikidata":"https://www.wikidata.org/wiki/Q17156588","display_name":"Resource management (computing)","level":2,"score":0.465016633272171},{"id":"https://openalex.org/C2742236","wikidata":"https://www.wikidata.org/wiki/Q924713","display_name":"Efficient energy use","level":2,"score":0.46182045340538025},{"id":"https://openalex.org/C206345919","wikidata":"https://www.wikidata.org/wiki/Q20380951","display_name":"Resource (disambiguation)","level":2,"score":0.44393259286880493},{"id":"https://openalex.org/C159694833","wikidata":"https://www.wikidata.org/wiki/Q2321565","display_name":"Iterative method","level":2,"score":0.43033742904663086},{"id":"https://openalex.org/C186370098","wikidata":"https://www.wikidata.org/wiki/Q442787","display_name":"Energy (signal processing)","level":2,"score":0.4276278018951416},{"id":"https://openalex.org/C65422117","wikidata":"https://www.wikidata.org/wiki/Q358527","display_name":"Transmitter power output","level":4,"score":0.4264177083969116},{"id":"https://openalex.org/C11413529","wikidata":"https://www.wikidata.org/wiki/Q8366","display_name":"Algorithm","level":1,"score":0.17303696274757385},{"id":"https://openalex.org/C31258907","wikidata":"https://www.wikidata.org/wiki/Q1301371","display_name":"Computer network","level":1,"score":0.16375195980072021},{"id":"https://openalex.org/C33923547","wikidata":"https://www.wikidata.org/wiki/Q395","display_name":"Mathematics","level":0,"score":0.1185506284236908},{"id":"https://openalex.org/C127413603","wikidata":"https://www.wikidata.org/wiki/Q11023","display_name":"Engineering","level":0,"score":0.09120124578475952},{"id":"https://openalex.org/C47798520","wikidata":"https://www.wikidata.org/wiki/Q190157","display_name":"Transmitter","level":3,"score":0.07574418187141418},{"id":"https://openalex.org/C119599485","wikidata":"https://www.wikidata.org/wiki/Q43035","display_name":"Electrical engineering","level":1,"score":0.06830480694770813},{"id":"https://openalex.org/C105795698","wikidata":"https://www.wikidata.org/wiki/Q12483","display_name":"Statistics","level":1,"score":0.06591606140136719},{"id":"https://openalex.org/C127162648","wikidata":"https://www.wikidata.org/wiki/Q16858953","display_name":"Channel (broadcasting)","level":2,"score":0.05701223015785217},{"id":"https://openalex.org/C121332964","wikidata":"https://www.wikidata.org/wiki/Q413","display_name":"Physics","level":0,"score":0.0},{"id":"https://openalex.org/C2524010","wikidata":"https://www.wikidata.org/wiki/Q8087","display_name":"Geometry","level":1,"score":0.0},{"id":"https://openalex.org/C62520636","wikidata":"https://www.wikidata.org/wiki/Q944","display_name":"Quantum mechanics","level":1,"score":0.0}],"mesh":[],"locations_count":3,"locations":[{"id":"doi:10.1109/iwcmc.2016.7577065","is_oa":false,"landing_page_url":"https://doi.org/10.1109/iwcmc.2016.7577065","pdf_url":null,"source":null,"license":null,"license_id":null,"version":"publishedVersion","is_accepted":true,"is_published":true,"raw_source_name":"2016 International Wireless Communications and Mobile Computing Conference (IWCMC)","raw_type":"proceedings-article"},{"id":"pmh:oai:pure.atira.dk:openaire_cris_publications/16da0b03-1cf4-4154-9533-618d1418f859","is_oa":false,"landing_page_url":"https://research.manchester.ac.uk/en/publications/16da0b03-1cf4-4154-9533-618d1418f859","pdf_url":null,"source":{"id":"https://openalex.org/S4306400662","display_name":"Research Explorer (The University of Manchester)","issn_l":null,"issn":null,"is_oa":false,"is_in_doaj":false,"is_core":false,"host_organization":"https://openalex.org/I28407311","host_organization_name":"University of Manchester","host_organization_lineage":["https://openalex.org/I28407311"],"host_organization_lineage_names":[],"type":"repository"},"license":null,"license_id":null,"version":"submittedVersion","is_accepted":false,"is_published":false,"raw_source_name":"Nabuuma, H, Alsusa, E, Pramudito, W & Baidas, M W 2016, 'A Power Allocation Technique for Fairness and Enhanced Energy Efficiency in Future Networks', International Wireless Communications and Mobile Computing Conference. https://doi.org/10.1109/IWCMC.2016.7577065","raw_type":"info:eu-repo/semantics/publishedVersion"},{"id":"pmh:oai:pure.atira.dk:publications/16da0b03-1cf4-4154-9533-618d1418f859","is_oa":false,"landing_page_url":"https://www.research.manchester.ac.uk/portal/en/publications/a-power-allocation-technique-for-fairness-and-enhanced-energy-efficiency-in-future-networks(16da0b03-1cf4-4154-9533-618d1418f859).html","pdf_url":null,"source":{"id":"https://openalex.org/S4306400662","display_name":"Research Explorer (The University of Manchester)","issn_l":null,"issn":null,"is_oa":false,"is_in_doaj":false,"is_core":false,"host_organization":"https://openalex.org/I28407311","host_organization_name":"University of Manchester","host_organization_lineage":["https://openalex.org/I28407311"],"host_organization_lineage_names":[],"type":"repository"},"license":null,"license_id":null,"version":"submittedVersion","is_accepted":false,"is_published":false,"raw_source_name":"Nabuuma, H, Alsusa, E, Pramudito, W & Baidas, M W 2016, 'A Power Allocation Technique for Fairness and Enhanced Energy Efficiency in Future Networks', International Wireless Communications and Mobile Computing Conference. https://doi.org/10.1109/IWCMC.2016.7577065","raw_type":"info:eu-repo/semantics/publishedVersion"}],"best_oa_location":null,"sustainable_development_goals":[{"score":0.7300000190734863,"display_name":"Affordable and clean energy","id":"https://metadata.un.org/sdg/7"}],"awards":[],"funders":[],"has_content":{"pdf":false,"grobid_xml":false},"content_urls":null,"referenced_works_count":13,"referenced_works":["https://openalex.org/W1733806262","https://openalex.org/W1975517253","https://openalex.org/W1981109871","https://openalex.org/W1994534328","https://openalex.org/W2023933382","https://openalex.org/W2042673020","https://openalex.org/W2065905494","https://openalex.org/W2095875373","https://openalex.org/W2109159967","https://openalex.org/W2115559954","https://openalex.org/W2136530738","https://openalex.org/W2142473263","https://openalex.org/W2168339944"],"related_works":["https://openalex.org/W2341847970","https://openalex.org/W2373207776","https://openalex.org/W2061187297","https://openalex.org/W2349594227","https://openalex.org/W2548647858","https://openalex.org/W2923452570","https://openalex.org/W2071821779","https://openalex.org/W1890643295","https://openalex.org/W2104478802","https://openalex.org/W1673345157"],"abstract_inverted_index":{"In":[0],"this":[1],"paper,":[2],"we":[3],"present":[4],"a":[5],"power":[6,85,123],"allocation":[7,28,129],"technique":[8,34,106,133],"that":[9,46,64,73,97],"improves":[10],"the":[11,19,33,41,47,59,71,99,104,115,131],"sum":[12,60],"rate":[13,22,50,61,118],"and":[14],"energy":[15,111],"efficiency":[16],"without":[17],"reducing":[18],"minimum":[20,48,116],"data":[21,49,117],"of":[23,101],"an":[24],"established":[25],"resource":[26,66,90],"block":[27,91],"technique.":[29],"To":[30],"achieve":[31],"this,":[32],"is":[35,43,56,79],"implemented":[36],"in":[37,83,87,89,109,135],"two":[38],"stages":[39],"where":[40],"first":[42],"for":[44,57],"ensuring":[45,63],"remains":[51],"unchanged.":[52],"The":[53,77],"second":[54],"stage":[55],"increasing":[58],"by":[62,70],"more":[65],"blocks":[67],"are":[68],"reused":[69],"femtocells":[72],"reduce":[74],"their":[75],"power.":[76],"algorithm":[78],"iterative":[80],"with":[81],"changes":[82,88],"transmit":[84],"resulting":[86],"allocation.":[92,124],"It":[93],"will":[94],"be":[95],"shown":[96],"at":[98],"expense":[100],"some":[102],"delay,":[103],"proposed":[105,132],"can":[107],"result":[108],"significant":[110],"savings":[112],"while":[113],"maintaining":[114],"when":[119],"compared":[120],"to":[121,127],"equal":[122],"Further,":[125],"relative":[126],"optimal":[128],"techniques,":[130],"results":[134],"better":[136],"fairness.":[137]},"counts_by_year":[],"updated_date":"2026-04-05T17:49:38.594831","created_date":"2025-10-10T00:00:00"}
