{"id":"https://openalex.org/W2077174722","doi":"https://doi.org/10.1109/iwcmc.2013.6583757","title":"Vibration sensor based intelligent fault diagnosis system for large machine unit in petrochemical industry","display_name":"Vibration sensor based intelligent fault diagnosis system for large machine unit in petrochemical industry","publication_year":2013,"publication_date":"2013-07-01","ids":{"openalex":"https://openalex.org/W2077174722","doi":"https://doi.org/10.1109/iwcmc.2013.6583757","mag":"2077174722"},"language":"en","primary_location":{"id":"doi:10.1109/iwcmc.2013.6583757","is_oa":false,"landing_page_url":"https://doi.org/10.1109/iwcmc.2013.6583757","pdf_url":null,"source":null,"license":null,"license_id":null,"version":"publishedVersion","is_accepted":true,"is_published":true,"raw_source_name":"2013 9th International Wireless Communications and Mobile Computing Conference (IWCMC)","raw_type":"proceedings-article"},"type":"article","indexed_in":["crossref"],"open_access":{"is_oa":false,"oa_status":"closed","oa_url":null,"any_repository_has_fulltext":false},"authorships":[{"author_position":"first","author":{"id":"https://openalex.org/A5100327265","display_name":"Qinghua Zhang","orcid":"https://orcid.org/0000-0002-0132-7422"},"institutions":[{"id":"https://openalex.org/I4210128140","display_name":"Guangdong University of Petrochemical Technology","ror":"https://ror.org/030ffke25","country_code":"CN","type":"education","lineage":["https://openalex.org/I4210128140"]}],"countries":["CN"],"is_corresponding":true,"raw_author_name":"Qing-Hua Zhang","raw_affiliation_strings":["Guangdong Petrochemical Equipment, Fault Diagnosis Key Laboratory, Guangdong University of Petrochemical Technology, Maoming, China","Guangdong Petrochem. Equip. Fault Diagnosis Key Lab., Guangdong Univ. of Petrochem. Technol., Maoming, China"],"affiliations":[{"raw_affiliation_string":"Guangdong Petrochemical Equipment, Fault Diagnosis Key Laboratory, Guangdong University of Petrochemical Technology, Maoming, China","institution_ids":["https://openalex.org/I4210128140"]},{"raw_affiliation_string":"Guangdong Petrochem. Equip. Fault Diagnosis Key Lab., Guangdong Univ. of Petrochem. Technol., Maoming, China","institution_ids":["https://openalex.org/I4210128140"]}]},{"author_position":"middle","author":{"id":"https://openalex.org/A5023867505","display_name":"Aisong Qin","orcid":"https://orcid.org/0000-0002-7365-4502"},"institutions":[{"id":"https://openalex.org/I9086337","display_name":"Taiyuan University of Technology","ror":"https://ror.org/03kv08d37","country_code":"CN","type":"education","lineage":["https://openalex.org/I9086337"]}],"countries":["CN"],"is_corresponding":false,"raw_author_name":"Aisong Qin","raw_affiliation_strings":["College of Information Engineering, Taiyuan University of Technology, Taiyuan, China","College of Information Engineering, Taiyuan University of Technology, Taiyuan, China#TAB#"],"affiliations":[{"raw_affiliation_string":"College of Information Engineering, Taiyuan University of Technology, Taiyuan, China","institution_ids":["https://openalex.org/I9086337"]},{"raw_affiliation_string":"College of Information Engineering, Taiyuan University of Technology, Taiyuan, China#TAB#","institution_ids":["https://openalex.org/I9086337"]}]},{"author_position":"middle","author":{"id":"https://openalex.org/A5007723627","display_name":"Lei Shu","orcid":"https://orcid.org/0000-0002-6700-9347"},"institutions":[{"id":"https://openalex.org/I4210128140","display_name":"Guangdong University of Petrochemical Technology","ror":"https://ror.org/030ffke25","country_code":"CN","type":"education","lineage":["https://openalex.org/I4210128140"]}],"countries":["CN"],"is_corresponding":false,"raw_author_name":"Lei Shu","raw_affiliation_strings":["Guangdong Petrochemical Equipment, Fault Diagnosis Key Laboratory, Guangdong University of Petrochemical Technology, Maoming, China","Guangdong Petrochem. Equip. Fault Diagnosis Key Lab., Guangdong Univ. of Petrochem. Technol., Maoming, China"],"affiliations":[{"raw_affiliation_string":"Guangdong Petrochemical Equipment, Fault Diagnosis Key Laboratory, Guangdong University of Petrochemical Technology, Maoming, China","institution_ids":["https://openalex.org/I4210128140"]},{"raw_affiliation_string":"Guangdong Petrochem. Equip. Fault Diagnosis Key Lab., Guangdong Univ. of Petrochem. Technol., Maoming, China","institution_ids":["https://openalex.org/I4210128140"]}]},{"author_position":"middle","author":{"id":"https://openalex.org/A5101793371","display_name":"Guoxi Sun","orcid":"https://orcid.org/0000-0001-8948-4221"},"institutions":[{"id":"https://openalex.org/I4210128140","display_name":"Guangdong University of Petrochemical Technology","ror":"https://ror.org/030ffke25","country_code":"CN","type":"education","lineage":["https://openalex.org/I4210128140"]}],"countries":["CN"],"is_corresponding":false,"raw_author_name":"Guoxi Sun","raw_affiliation_strings":["Guangdong Petrochemical Equipment Fault Diagnosis Key Laboratory, Guangdong University of Petrochemical Technology, Maoming, China","Guangdong Petrochem. Equip. Fault Diagnosis Key Lab., Guangdong Univ. of Petrochem. Technol., Maoming, China"],"affiliations":[{"raw_affiliation_string":"Guangdong Petrochemical Equipment Fault Diagnosis Key Laboratory, Guangdong University of Petrochemical Technology, Maoming, China","institution_ids":["https://openalex.org/I4210128140"]},{"raw_affiliation_string":"Guangdong Petrochem. Equip. Fault Diagnosis Key Lab., Guangdong Univ. of Petrochem. Technol., Maoming, China","institution_ids":["https://openalex.org/I4210128140"]}]},{"author_position":"last","author":{"id":"https://openalex.org/A5072733449","display_name":"Longqiu Shao","orcid":null},"institutions":[{"id":"https://openalex.org/I4210128140","display_name":"Guangdong University of Petrochemical Technology","ror":"https://ror.org/030ffke25","country_code":"CN","type":"education","lineage":["https://openalex.org/I4210128140"]}],"countries":["CN"],"is_corresponding":false,"raw_author_name":"Longqiu Shao","raw_affiliation_strings":["Guangdong Petrochemical Equipment Fault Diagnosis Key Laboratory, Guangdong University of Petrochemical Technology, Maoming, China","Guangdong Petrochem. Equip. Fault Diagnosis Key Lab., Guangdong Univ. of Petrochem. Technol., Maoming, China"],"affiliations":[{"raw_affiliation_string":"Guangdong Petrochemical Equipment Fault Diagnosis Key Laboratory, Guangdong University of Petrochemical Technology, Maoming, China","institution_ids":["https://openalex.org/I4210128140"]},{"raw_affiliation_string":"Guangdong Petrochem. Equip. Fault Diagnosis Key Lab., Guangdong Univ. of Petrochem. Technol., Maoming, China","institution_ids":["https://openalex.org/I4210128140"]}]}],"institutions":[],"countries_distinct_count":1,"institutions_distinct_count":5,"corresponding_author_ids":["https://openalex.org/A5100327265"],"corresponding_institution_ids":["https://openalex.org/I4210128140"],"apc_list":null,"apc_paid":null,"fwci":0.0,"has_fulltext":false,"cited_by_count":4,"citation_normalized_percentile":{"value":0.15125793,"is_in_top_1_percent":false,"is_in_top_10_percent":false},"cited_by_percentile_year":{"min":90,"max":95},"biblio":{"volume":null,"issue":null,"first_page":"1376","last_page":"1381"},"is_retracted":false,"is_paratext":false,"is_xpac":false,"primary_topic":{"id":"https://openalex.org/T14225","display_name":"Advanced Sensor and Control Systems","score":0.974399983882904,"subfield":{"id":"https://openalex.org/subfields/2207","display_name":"Control and Systems Engineering"},"field":{"id":"https://openalex.org/fields/22","display_name":"Engineering"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}},"topics":[{"id":"https://openalex.org/T14225","display_name":"Advanced Sensor and Control Systems","score":0.974399983882904,"subfield":{"id":"https://openalex.org/subfields/2207","display_name":"Control and Systems Engineering"},"field":{"id":"https://openalex.org/fields/22","display_name":"Engineering"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}},{"id":"https://openalex.org/T13717","display_name":"Advanced Algorithms and Applications","score":0.9638000130653381,"subfield":{"id":"https://openalex.org/subfields/2207","display_name":"Control and Systems Engineering"},"field":{"id":"https://openalex.org/fields/22","display_name":"Engineering"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}},{"id":"https://openalex.org/T14474","display_name":"Industrial Technology and Control Systems","score":0.9391999840736389,"subfield":{"id":"https://openalex.org/subfields/2207","display_name":"Control and Systems Engineering"},"field":{"id":"https://openalex.org/fields/22","display_name":"Engineering"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}}],"keywords":[{"id":"https://openalex.org/keywords/petrochemical","display_name":"Petrochemical","score":0.8262343406677246},{"id":"https://openalex.org/keywords/fault","display_name":"Fault (geology)","score":0.6633706092834473},{"id":"https://openalex.org/keywords/reliability","display_name":"Reliability (semiconductor)","score":0.5968320369720459},{"id":"https://openalex.org/keywords/condition-monitoring","display_name":"Condition monitoring","score":0.5915048122406006},{"id":"https://openalex.org/keywords/vibration","display_name":"Vibration","score":0.5463373064994812},{"id":"https://openalex.org/keywords/fault-detection-and-isolation","display_name":"Fault detection and isolation","score":0.4920365512371063},{"id":"https://openalex.org/keywords/computer-science","display_name":"Computer science","score":0.48301705718040466},{"id":"https://openalex.org/keywords/focus","display_name":"Focus (optics)","score":0.46709316968917847},{"id":"https://openalex.org/keywords/control-engineering","display_name":"Control engineering","score":0.4366368055343628},{"id":"https://openalex.org/keywords/engineering","display_name":"Engineering","score":0.43112173676490784},{"id":"https://openalex.org/keywords/real-time-computing","display_name":"Real-time computing","score":0.35287246108055115},{"id":"https://openalex.org/keywords/reliability-engineering","display_name":"Reliability engineering","score":0.3471306562423706},{"id":"https://openalex.org/keywords/artificial-intelligence","display_name":"Artificial intelligence","score":0.23298418521881104},{"id":"https://openalex.org/keywords/actuator","display_name":"Actuator","score":0.1370212435722351},{"id":"https://openalex.org/keywords/waste-management","display_name":"Waste management","score":0.09666112065315247}],"concepts":[{"id":"https://openalex.org/C170573351","wikidata":"https://www.wikidata.org/wiki/Q1364904","display_name":"Petrochemical","level":2,"score":0.8262343406677246},{"id":"https://openalex.org/C175551986","wikidata":"https://www.wikidata.org/wiki/Q47089","display_name":"Fault (geology)","level":2,"score":0.6633706092834473},{"id":"https://openalex.org/C43214815","wikidata":"https://www.wikidata.org/wiki/Q7310987","display_name":"Reliability (semiconductor)","level":3,"score":0.5968320369720459},{"id":"https://openalex.org/C2775846686","wikidata":"https://www.wikidata.org/wiki/Q643012","display_name":"Condition monitoring","level":2,"score":0.5915048122406006},{"id":"https://openalex.org/C198394728","wikidata":"https://www.wikidata.org/wiki/Q3695508","display_name":"Vibration","level":2,"score":0.5463373064994812},{"id":"https://openalex.org/C152745839","wikidata":"https://www.wikidata.org/wiki/Q5438153","display_name":"Fault detection and isolation","level":3,"score":0.4920365512371063},{"id":"https://openalex.org/C41008148","wikidata":"https://www.wikidata.org/wiki/Q21198","display_name":"Computer science","level":0,"score":0.48301705718040466},{"id":"https://openalex.org/C192209626","wikidata":"https://www.wikidata.org/wiki/Q190909","display_name":"Focus (optics)","level":2,"score":0.46709316968917847},{"id":"https://openalex.org/C133731056","wikidata":"https://www.wikidata.org/wiki/Q4917288","display_name":"Control engineering","level":1,"score":0.4366368055343628},{"id":"https://openalex.org/C127413603","wikidata":"https://www.wikidata.org/wiki/Q11023","display_name":"Engineering","level":0,"score":0.43112173676490784},{"id":"https://openalex.org/C79403827","wikidata":"https://www.wikidata.org/wiki/Q3988","display_name":"Real-time computing","level":1,"score":0.35287246108055115},{"id":"https://openalex.org/C200601418","wikidata":"https://www.wikidata.org/wiki/Q2193887","display_name":"Reliability engineering","level":1,"score":0.3471306562423706},{"id":"https://openalex.org/C154945302","wikidata":"https://www.wikidata.org/wiki/Q11660","display_name":"Artificial intelligence","level":1,"score":0.23298418521881104},{"id":"https://openalex.org/C172707124","wikidata":"https://www.wikidata.org/wiki/Q423488","display_name":"Actuator","level":2,"score":0.1370212435722351},{"id":"https://openalex.org/C548081761","wikidata":"https://www.wikidata.org/wiki/Q180388","display_name":"Waste management","level":1,"score":0.09666112065315247},{"id":"https://openalex.org/C163258240","wikidata":"https://www.wikidata.org/wiki/Q25342","display_name":"Power (physics)","level":2,"score":0.0},{"id":"https://openalex.org/C165205528","wikidata":"https://www.wikidata.org/wiki/Q83371","display_name":"Seismology","level":1,"score":0.0},{"id":"https://openalex.org/C121332964","wikidata":"https://www.wikidata.org/wiki/Q413","display_name":"Physics","level":0,"score":0.0},{"id":"https://openalex.org/C120665830","wikidata":"https://www.wikidata.org/wiki/Q14620","display_name":"Optics","level":1,"score":0.0},{"id":"https://openalex.org/C127313418","wikidata":"https://www.wikidata.org/wiki/Q1069","display_name":"Geology","level":0,"score":0.0},{"id":"https://openalex.org/C62520636","wikidata":"https://www.wikidata.org/wiki/Q944","display_name":"Quantum mechanics","level":1,"score":0.0},{"id":"https://openalex.org/C119599485","wikidata":"https://www.wikidata.org/wiki/Q43035","display_name":"Electrical engineering","level":1,"score":0.0}],"mesh":[],"locations_count":1,"locations":[{"id":"doi:10.1109/iwcmc.2013.6583757","is_oa":false,"landing_page_url":"https://doi.org/10.1109/iwcmc.2013.6583757","pdf_url":null,"source":null,"license":null,"license_id":null,"version":"publishedVersion","is_accepted":true,"is_published":true,"raw_source_name":"2013 9th International Wireless Communications and Mobile Computing Conference (IWCMC)","raw_type":"proceedings-article"}],"best_oa_location":null,"sustainable_development_goals":[{"display_name":"Industry, innovation and infrastructure","score":0.6700000166893005,"id":"https://metadata.un.org/sdg/9"}],"awards":[],"funders":[],"has_content":{"pdf":false,"grobid_xml":false},"content_urls":null,"referenced_works_count":7,"referenced_works":["https://openalex.org/W2050918341","https://openalex.org/W2083227749","https://openalex.org/W2354446921","https://openalex.org/W2365679352","https://openalex.org/W2369974664","https://openalex.org/W2378444581","https://openalex.org/W2380667876"],"related_works":["https://openalex.org/W4220848840","https://openalex.org/W2385820548","https://openalex.org/W2369484037","https://openalex.org/W2392576762","https://openalex.org/W2626428222","https://openalex.org/W2351703597","https://openalex.org/W2376523010","https://openalex.org/W2156186572","https://openalex.org/W2554683084","https://openalex.org/W1996858460"],"abstract_inverted_index":{"In":[0],"this":[1],"paper,":[2],"to":[3,62],"satisfy":[4],"the":[5,63],"need":[6],"of":[7],"fault":[8,33,37],"monitoring,":[9],"dynamic":[10],"real":[11],"time":[12],"vibration":[13,16],"monitoring":[14,56],"and":[15,31,46,57,59,73],"signal":[17],"analysis":[18],"for":[19],"large":[20],"machine":[21],"unit":[22],"in":[23,69],"petrochemical":[24,71],"industry,":[25],"which":[26],"cannot":[27],"realize":[28],"real-time,":[29],"online":[30],"fast":[32],"diagnosis,":[34],"an":[35],"intelligent":[36],"diagnosis":[38],"system":[39],"is":[40],"developed":[41],"using":[42],"artificial":[43],"immune":[44],"algorithm":[45],"dimensionless":[47],"indicators,":[48],"innovated":[49],"with":[50],"a":[51,70],"focus":[52],"on":[53],"reliability,":[54],"remote":[55],"practicality,":[58],"be":[60],"applied":[61],"Third":[64],"Catalytic":[65],"Flue":[66],"Gas":[67],"Turbine":[68],"enterprise":[72],"have":[74],"got":[75],"good":[76],"effects.":[77]},"counts_by_year":[{"year":2025,"cited_by_count":1},{"year":2021,"cited_by_count":2},{"year":2017,"cited_by_count":1}],"updated_date":"2025-11-06T03:46:38.306776","created_date":"2025-10-10T00:00:00"}
