{"id":"https://openalex.org/W2034139677","doi":"https://doi.org/10.1109/iswcs.2014.6933457","title":"Area energy efficiency analysis for OFDMA femtocell networks","display_name":"Area energy efficiency analysis for OFDMA femtocell networks","publication_year":2014,"publication_date":"2014-08-01","ids":{"openalex":"https://openalex.org/W2034139677","doi":"https://doi.org/10.1109/iswcs.2014.6933457","mag":"2034139677"},"language":"en","primary_location":{"id":"doi:10.1109/iswcs.2014.6933457","is_oa":false,"landing_page_url":"https://doi.org/10.1109/iswcs.2014.6933457","pdf_url":null,"source":null,"license":null,"license_id":null,"version":"publishedVersion","is_accepted":true,"is_published":true,"raw_source_name":"2014 11th International Symposium on Wireless Communications Systems (ISWCS)","raw_type":"proceedings-article"},"type":"article","indexed_in":["crossref"],"open_access":{"is_oa":false,"oa_status":"closed","oa_url":null,"any_repository_has_fulltext":false},"authorships":[{"author_position":"first","author":{"id":"https://openalex.org/A5087146909","display_name":"Prabhu Chandhar","orcid":"https://orcid.org/0000-0003-1068-2503"},"institutions":[{"id":"https://openalex.org/I145894827","display_name":"Indian Institute of Technology Kharagpur","ror":"https://ror.org/03w5sq511","country_code":"IN","type":"education","lineage":["https://openalex.org/I145894827"]}],"countries":["IN"],"is_corresponding":false,"raw_author_name":"Prabhu Chandhar","raw_affiliation_strings":["Indian Institute of Technology Kharagpur, India","Indian Institute of Technology, Kharagpur, India"],"raw_orcid":null,"affiliations":[{"raw_affiliation_string":"Indian Institute of Technology Kharagpur, India","institution_ids":["https://openalex.org/I145894827"]},{"raw_affiliation_string":"Indian Institute of Technology, Kharagpur, India","institution_ids":["https://openalex.org/I145894827"]}]},{"author_position":"last","author":{"id":"https://openalex.org/A5073522616","display_name":"Suvra Sekhar Das","orcid":"https://orcid.org/0000-0002-9623-2134"},"institutions":[{"id":"https://openalex.org/I145894827","display_name":"Indian Institute of Technology Kharagpur","ror":"https://ror.org/03w5sq511","country_code":"IN","type":"education","lineage":["https://openalex.org/I145894827"]}],"countries":["IN"],"is_corresponding":false,"raw_author_name":"Suvra Sekhar Das","raw_affiliation_strings":["Indian Institute of Technology Kharagpur, India","Indian Institute of Technology, Kharagpur, India"],"raw_orcid":null,"affiliations":[{"raw_affiliation_string":"Indian Institute of Technology Kharagpur, India","institution_ids":["https://openalex.org/I145894827"]},{"raw_affiliation_string":"Indian Institute of Technology, Kharagpur, India","institution_ids":["https://openalex.org/I145894827"]}]}],"institutions":[],"countries_distinct_count":1,"institutions_distinct_count":2,"corresponding_author_ids":[],"corresponding_institution_ids":[],"apc_list":null,"apc_paid":null,"fwci":0.2129,"has_fulltext":false,"cited_by_count":1,"citation_normalized_percentile":{"value":0.59448353,"is_in_top_1_percent":false,"is_in_top_10_percent":false},"cited_by_percentile_year":{"min":90,"max":94},"biblio":{"volume":null,"issue":null,"first_page":"771","last_page":"775"},"is_retracted":false,"is_paratext":false,"is_xpac":false,"primary_topic":{"id":"https://openalex.org/T10148","display_name":"Advanced MIMO Systems Optimization","score":0.9997000098228455,"subfield":{"id":"https://openalex.org/subfields/2208","display_name":"Electrical and Electronic Engineering"},"field":{"id":"https://openalex.org/fields/22","display_name":"Engineering"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}},"topics":[{"id":"https://openalex.org/T10148","display_name":"Advanced MIMO Systems Optimization","score":0.9997000098228455,"subfield":{"id":"https://openalex.org/subfields/2208","display_name":"Electrical and Electronic Engineering"},"field":{"id":"https://openalex.org/fields/22","display_name":"Engineering"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}},{"id":"https://openalex.org/T10796","display_name":"Cooperative Communication and Network Coding","score":0.9972000122070312,"subfield":{"id":"https://openalex.org/subfields/1705","display_name":"Computer Networks and Communications"},"field":{"id":"https://openalex.org/fields/17","display_name":"Computer Science"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}},{"id":"https://openalex.org/T11409","display_name":"Advanced Wireless Network Optimization","score":0.9883999824523926,"subfield":{"id":"https://openalex.org/subfields/2208","display_name":"Electrical and Electronic Engineering"},"field":{"id":"https://openalex.org/fields/22","display_name":"Engineering"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}}],"keywords":[{"id":"https://openalex.org/keywords/femtocell","display_name":"Femtocell","score":0.9960801601409912},{"id":"https://openalex.org/keywords/macrocell","display_name":"Macrocell","score":0.9958397150039673},{"id":"https://openalex.org/keywords/computer-network","display_name":"Computer network","score":0.7193179130554199},{"id":"https://openalex.org/keywords/computer-science","display_name":"Computer science","score":0.7047738432884216},{"id":"https://openalex.org/keywords/efficient-energy-use","display_name":"Efficient energy use","score":0.6125892400741577},{"id":"https://openalex.org/keywords/quality-of-service","display_name":"Quality of service","score":0.556634247303009},{"id":"https://openalex.org/keywords/software-deployment","display_name":"Software deployment","score":0.46100398898124695},{"id":"https://openalex.org/keywords/base-station","display_name":"Base station","score":0.21195361018180847},{"id":"https://openalex.org/keywords/engineering","display_name":"Engineering","score":0.1609465479850769},{"id":"https://openalex.org/keywords/electrical-engineering","display_name":"Electrical engineering","score":0.07794055342674255}],"concepts":[{"id":"https://openalex.org/C152504517","wikidata":"https://www.wikidata.org/wiki/Q572455","display_name":"Femtocell","level":3,"score":0.9960801601409912},{"id":"https://openalex.org/C2778291847","wikidata":"https://www.wikidata.org/wiki/Q1163937","display_name":"Macrocell","level":3,"score":0.9958397150039673},{"id":"https://openalex.org/C31258907","wikidata":"https://www.wikidata.org/wiki/Q1301371","display_name":"Computer network","level":1,"score":0.7193179130554199},{"id":"https://openalex.org/C41008148","wikidata":"https://www.wikidata.org/wiki/Q21198","display_name":"Computer science","level":0,"score":0.7047738432884216},{"id":"https://openalex.org/C2742236","wikidata":"https://www.wikidata.org/wiki/Q924713","display_name":"Efficient energy use","level":2,"score":0.6125892400741577},{"id":"https://openalex.org/C5119721","wikidata":"https://www.wikidata.org/wiki/Q220501","display_name":"Quality of service","level":2,"score":0.556634247303009},{"id":"https://openalex.org/C105339364","wikidata":"https://www.wikidata.org/wiki/Q2297740","display_name":"Software deployment","level":2,"score":0.46100398898124695},{"id":"https://openalex.org/C68649174","wikidata":"https://www.wikidata.org/wiki/Q1379116","display_name":"Base station","level":2,"score":0.21195361018180847},{"id":"https://openalex.org/C127413603","wikidata":"https://www.wikidata.org/wiki/Q11023","display_name":"Engineering","level":0,"score":0.1609465479850769},{"id":"https://openalex.org/C119599485","wikidata":"https://www.wikidata.org/wiki/Q43035","display_name":"Electrical engineering","level":1,"score":0.07794055342674255},{"id":"https://openalex.org/C111919701","wikidata":"https://www.wikidata.org/wiki/Q9135","display_name":"Operating system","level":1,"score":0.0}],"mesh":[],"locations_count":1,"locations":[{"id":"doi:10.1109/iswcs.2014.6933457","is_oa":false,"landing_page_url":"https://doi.org/10.1109/iswcs.2014.6933457","pdf_url":null,"source":null,"license":null,"license_id":null,"version":"publishedVersion","is_accepted":true,"is_published":true,"raw_source_name":"2014 11th International Symposium on Wireless Communications Systems (ISWCS)","raw_type":"proceedings-article"}],"best_oa_location":null,"sustainable_development_goals":[{"id":"https://metadata.un.org/sdg/7","score":0.8799999952316284,"display_name":"Affordable and clean energy"}],"awards":[],"funders":[],"has_content":{"grobid_xml":false,"pdf":false},"content_urls":null,"referenced_works_count":16,"referenced_works":["https://openalex.org/W1974564856","https://openalex.org/W1975638417","https://openalex.org/W1990857298","https://openalex.org/W2014060493","https://openalex.org/W2037001149","https://openalex.org/W2063562647","https://openalex.org/W2109159967","https://openalex.org/W2115559954","https://openalex.org/W2120419969","https://openalex.org/W2122496159","https://openalex.org/W2141003152","https://openalex.org/W2146189856","https://openalex.org/W2147231243","https://openalex.org/W2160998689","https://openalex.org/W6681231416","https://openalex.org/W6681746803"],"related_works":["https://openalex.org/W2040311827","https://openalex.org/W2034139677","https://openalex.org/W2206637726","https://openalex.org/W1519632632","https://openalex.org/W2479641731","https://openalex.org/W2108749951","https://openalex.org/W117540911","https://openalex.org/W2138783567","https://openalex.org/W1976777118","https://openalex.org/W15850631"],"abstract_inverted_index":{"Deployment":[0],"of":[1,15,19,44,59,73,98,101],"femtocells":[2],"(Home":[3],"eNode":[4],"Bs)":[5],"along":[6],"with":[7],"existing":[8],"macrocells":[9],"has":[10],"been":[11],"drawn":[12],"considerable":[13],"attention":[14],"mobile":[16],"industry":[17],"because":[18],"its":[20],"potential":[21],"to":[22,26,34,89],"reduce":[23],"Operational":[24],"Expenditure":[25],"the":[27,41,57,64,96],"operators":[28],"by":[29,81],"offloading":[30],"traffic":[31,91],"from":[32],"macrocell":[33,84,102],"femtocells.":[35],"In":[36],"this":[37],"paper,":[38],"we":[39],"evaluate":[40],"energy":[42,65,76],"efficiency":[43,77],"co-channel":[45],"deployed":[46],"macrocell-femtocell":[47],"networks":[48],"considering":[49],"centralized":[50],"control":[51],"for":[52],"HeNBs.":[53],"We":[54],"also":[55],"show":[56,69],"impact":[58],"macro-cell":[60],"power":[61],"configuration":[62],"on":[63],"efficiency.":[66],"The":[67],"results":[68],"that":[70],"significant":[71],"amount":[72],"improvement":[74],"in":[75],"can":[78],"be":[79],"achieved":[80],"centrally":[82],"coordinating":[83],"and":[85,103],"femtocell":[86,104],"networks,":[87],"according":[88],"varying":[90],"load":[92],"condition":[93],"without":[94],"affecting":[95],"Quality":[97],"Service":[99],"requirements":[100],"users.":[105]},"counts_by_year":[{"year":2015,"cited_by_count":1}],"updated_date":"2026-06-11T09:08:48.828518","created_date":"2025-10-10T00:00:00"}
