{"id":"https://openalex.org/W2407947356","doi":"https://doi.org/10.1109/isplc.2016.7476292","title":"Analysis of channel characteristics and modeling of a transformer for PLC-based loss-of-mains concept","display_name":"Analysis of channel characteristics and modeling of a transformer for PLC-based loss-of-mains concept","publication_year":2016,"publication_date":"2016-03-01","ids":{"openalex":"https://openalex.org/W2407947356","doi":"https://doi.org/10.1109/isplc.2016.7476292","mag":"2407947356"},"language":"en","primary_location":{"id":"doi:10.1109/isplc.2016.7476292","is_oa":false,"landing_page_url":"https://doi.org/10.1109/isplc.2016.7476292","pdf_url":null,"source":null,"license":null,"license_id":null,"version":"publishedVersion","is_accepted":true,"is_published":true,"raw_source_name":"2016 International Symposium on Power Line Communications and its Applications (ISPLC)","raw_type":"proceedings-article"},"type":"article","indexed_in":["crossref"],"open_access":{"is_oa":false,"oa_status":"closed","oa_url":null,"any_repository_has_fulltext":false},"authorships":[{"author_position":"first","author":{"id":"https://openalex.org/A5079475867","display_name":"Antti Pinomaa","orcid":"https://orcid.org/0000-0001-7620-1114"},"institutions":[{"id":"https://openalex.org/I63548447","display_name":"Lappeenranta-Lahti University of Technology","ror":"https://ror.org/0208vgz68","country_code":"FI","type":"education","lineage":["https://openalex.org/I63548447"]}],"countries":["FI"],"is_corresponding":false,"raw_author_name":"A. Pinomaa","raw_affiliation_strings":["Electrical Engineering, Lappeenranta University of Technology (LUT), Lappeenranta, Finland"],"raw_orcid":null,"affiliations":[{"raw_affiliation_string":"Electrical Engineering, Lappeenranta University of Technology (LUT), Lappeenranta, Finland","institution_ids":["https://openalex.org/I63548447"]}]},{"author_position":"middle","author":{"id":"https://openalex.org/A5059730829","display_name":"Anton Poluektov","orcid":null},"institutions":[{"id":"https://openalex.org/I63548447","display_name":"Lappeenranta-Lahti University of Technology","ror":"https://ror.org/0208vgz68","country_code":"FI","type":"education","lineage":["https://openalex.org/I63548447"]}],"countries":["FI"],"is_corresponding":false,"raw_author_name":"A. Poluektov","raw_affiliation_strings":["Electrical Engineering, Lappeenranta University of Technology (LUT), Lappeenranta, Finland"],"raw_orcid":null,"affiliations":[{"raw_affiliation_string":"Electrical Engineering, Lappeenranta University of Technology (LUT), Lappeenranta, Finland","institution_ids":["https://openalex.org/I63548447"]}]},{"author_position":"middle","author":{"id":"https://openalex.org/A5019986727","display_name":"Jero Ahola","orcid":"https://orcid.org/0000-0003-1082-8023"},"institutions":[{"id":"https://openalex.org/I63548447","display_name":"Lappeenranta-Lahti University of Technology","ror":"https://ror.org/0208vgz68","country_code":"FI","type":"education","lineage":["https://openalex.org/I63548447"]}],"countries":["FI"],"is_corresponding":false,"raw_author_name":"J. Ahola","raw_affiliation_strings":["Electrical Engineering, Lappeenranta University of Technology (LUT), Lappeenranta, Finland"],"raw_orcid":null,"affiliations":[{"raw_affiliation_string":"Electrical Engineering, Lappeenranta University of Technology (LUT), Lappeenranta, Finland","institution_ids":["https://openalex.org/I63548447"]}]},{"author_position":"last","author":{"id":"https://openalex.org/A5084978887","display_name":"Antti Kosonen","orcid":"https://orcid.org/0000-0003-0656-8310"},"institutions":[{"id":"https://openalex.org/I63548447","display_name":"Lappeenranta-Lahti University of Technology","ror":"https://ror.org/0208vgz68","country_code":"FI","type":"education","lineage":["https://openalex.org/I63548447"]}],"countries":["FI"],"is_corresponding":false,"raw_author_name":"A. Kosonen","raw_affiliation_strings":["Electrical Engineering, Lappeenranta University of Technology (LUT), Lappeenranta, Finland"],"raw_orcid":null,"affiliations":[{"raw_affiliation_string":"Electrical Engineering, Lappeenranta University of Technology (LUT), Lappeenranta, Finland","institution_ids":["https://openalex.org/I63548447"]}]}],"institutions":[],"countries_distinct_count":1,"institutions_distinct_count":1,"corresponding_author_ids":[],"corresponding_institution_ids":["https://openalex.org/I63548447"],"apc_list":null,"apc_paid":null,"fwci":0.93,"has_fulltext":false,"cited_by_count":5,"citation_normalized_percentile":{"value":0.77742605,"is_in_top_1_percent":false,"is_in_top_10_percent":false},"cited_by_percentile_year":{"min":90,"max":96},"biblio":{"volume":null,"issue":null,"first_page":"230","last_page":"235"},"is_retracted":false,"is_paratext":false,"is_xpac":false,"primary_topic":{"id":"https://openalex.org/T12146","display_name":"Power Line Communications and Noise","score":1.0,"subfield":{"id":"https://openalex.org/subfields/2208","display_name":"Electrical and Electronic Engineering"},"field":{"id":"https://openalex.org/fields/22","display_name":"Engineering"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}},"topics":[{"id":"https://openalex.org/T12146","display_name":"Power Line Communications and Noise","score":1.0,"subfield":{"id":"https://openalex.org/subfields/2208","display_name":"Electrical and Electronic Engineering"},"field":{"id":"https://openalex.org/fields/22","display_name":"Engineering"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}},{"id":"https://openalex.org/T13183","display_name":"Islanding Detection in Power Systems","score":0.9983000159263611,"subfield":{"id":"https://openalex.org/subfields/2208","display_name":"Electrical and Electronic Engineering"},"field":{"id":"https://openalex.org/fields/22","display_name":"Engineering"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}},{"id":"https://openalex.org/T11444","display_name":"Electromagnetic Compatibility and Noise Suppression","score":0.9966999888420105,"subfield":{"id":"https://openalex.org/subfields/2208","display_name":"Electrical and Electronic Engineering"},"field":{"id":"https://openalex.org/fields/22","display_name":"Engineering"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}}],"keywords":[{"id":"https://openalex.org/keywords/transformer","display_name":"Transformer","score":0.7389572858810425},{"id":"https://openalex.org/keywords/electrical-engineering","display_name":"Electrical engineering","score":0.6581006050109863},{"id":"https://openalex.org/keywords/grid","display_name":"Grid","score":0.5831087827682495},{"id":"https://openalex.org/keywords/mains-electricity","display_name":"Mains electricity","score":0.5512677431106567},{"id":"https://openalex.org/keywords/electrical-impedance","display_name":"Electrical impedance","score":0.5387474298477173},{"id":"https://openalex.org/keywords/smart-grid","display_name":"Smart grid","score":0.5188947319984436},{"id":"https://openalex.org/keywords/engineering","display_name":"Engineering","score":0.49683454632759094},{"id":"https://openalex.org/keywords/distribution-transformer","display_name":"Distribution transformer","score":0.4913119375705719},{"id":"https://openalex.org/keywords/power-grid","display_name":"Power grid","score":0.4833647608757019},{"id":"https://openalex.org/keywords/isolation-transformer","display_name":"Isolation transformer","score":0.4696463942527771},{"id":"https://openalex.org/keywords/power-line-communication","display_name":"Power-line communication","score":0.44498211145401},{"id":"https://openalex.org/keywords/electronic-engineering","display_name":"Electronic engineering","score":0.44482287764549255},{"id":"https://openalex.org/keywords/voltage","display_name":"Voltage","score":0.4315437078475952},{"id":"https://openalex.org/keywords/current-transformer","display_name":"Current transformer","score":0.42627355456352234},{"id":"https://openalex.org/keywords/electrical-conductor","display_name":"Electrical conductor","score":0.42335444688796997},{"id":"https://openalex.org/keywords/computer-science","display_name":"Computer science","score":0.3934710621833801},{"id":"https://openalex.org/keywords/power","display_name":"Power (physics)","score":0.19122973084449768},{"id":"https://openalex.org/keywords/physics","display_name":"Physics","score":0.11736676096916199}],"concepts":[{"id":"https://openalex.org/C66322947","wikidata":"https://www.wikidata.org/wiki/Q11658","display_name":"Transformer","level":3,"score":0.7389572858810425},{"id":"https://openalex.org/C119599485","wikidata":"https://www.wikidata.org/wiki/Q43035","display_name":"Electrical engineering","level":1,"score":0.6581006050109863},{"id":"https://openalex.org/C187691185","wikidata":"https://www.wikidata.org/wiki/Q2020720","display_name":"Grid","level":2,"score":0.5831087827682495},{"id":"https://openalex.org/C184773241","wikidata":"https://www.wikidata.org/wiki/Q387400","display_name":"Mains electricity","level":3,"score":0.5512677431106567},{"id":"https://openalex.org/C17829176","wikidata":"https://www.wikidata.org/wiki/Q179043","display_name":"Electrical impedance","level":2,"score":0.5387474298477173},{"id":"https://openalex.org/C10558101","wikidata":"https://www.wikidata.org/wiki/Q689855","display_name":"Smart grid","level":2,"score":0.5188947319984436},{"id":"https://openalex.org/C127413603","wikidata":"https://www.wikidata.org/wiki/Q11023","display_name":"Engineering","level":0,"score":0.49683454632759094},{"id":"https://openalex.org/C117323899","wikidata":"https://www.wikidata.org/wiki/Q1907989","display_name":"Distribution transformer","level":4,"score":0.4913119375705719},{"id":"https://openalex.org/C2983254600","wikidata":"https://www.wikidata.org/wiki/Q1096907","display_name":"Power grid","level":3,"score":0.4833647608757019},{"id":"https://openalex.org/C180850520","wikidata":"https://www.wikidata.org/wiki/Q2166404","display_name":"Isolation transformer","level":4,"score":0.4696463942527771},{"id":"https://openalex.org/C132885549","wikidata":"https://www.wikidata.org/wiki/Q271870","display_name":"Power-line communication","level":3,"score":0.44498211145401},{"id":"https://openalex.org/C24326235","wikidata":"https://www.wikidata.org/wiki/Q126095","display_name":"Electronic engineering","level":1,"score":0.44482287764549255},{"id":"https://openalex.org/C165801399","wikidata":"https://www.wikidata.org/wiki/Q25428","display_name":"Voltage","level":2,"score":0.4315437078475952},{"id":"https://openalex.org/C133770746","wikidata":"https://www.wikidata.org/wiki/Q856535","display_name":"Current transformer","level":4,"score":0.42627355456352234},{"id":"https://openalex.org/C202374169","wikidata":"https://www.wikidata.org/wiki/Q124291","display_name":"Electrical conductor","level":2,"score":0.42335444688796997},{"id":"https://openalex.org/C41008148","wikidata":"https://www.wikidata.org/wiki/Q21198","display_name":"Computer science","level":0,"score":0.3934710621833801},{"id":"https://openalex.org/C163258240","wikidata":"https://www.wikidata.org/wiki/Q25342","display_name":"Power (physics)","level":2,"score":0.19122973084449768},{"id":"https://openalex.org/C121332964","wikidata":"https://www.wikidata.org/wiki/Q413","display_name":"Physics","level":0,"score":0.11736676096916199},{"id":"https://openalex.org/C2524010","wikidata":"https://www.wikidata.org/wiki/Q8087","display_name":"Geometry","level":1,"score":0.0},{"id":"https://openalex.org/C62520636","wikidata":"https://www.wikidata.org/wiki/Q944","display_name":"Quantum mechanics","level":1,"score":0.0},{"id":"https://openalex.org/C33923547","wikidata":"https://www.wikidata.org/wiki/Q395","display_name":"Mathematics","level":0,"score":0.0}],"mesh":[],"locations_count":1,"locations":[{"id":"doi:10.1109/isplc.2016.7476292","is_oa":false,"landing_page_url":"https://doi.org/10.1109/isplc.2016.7476292","pdf_url":null,"source":null,"license":null,"license_id":null,"version":"publishedVersion","is_accepted":true,"is_published":true,"raw_source_name":"2016 International Symposium on Power Line Communications and its Applications (ISPLC)","raw_type":"proceedings-article"}],"best_oa_location":null,"sustainable_development_goals":[{"display_name":"Affordable and clean energy","id":"https://metadata.un.org/sdg/7","score":0.8199999928474426}],"awards":[],"funders":[],"has_content":{"grobid_xml":false,"pdf":false},"content_urls":null,"referenced_works_count":21,"referenced_works":["https://openalex.org/W1532281234","https://openalex.org/W1981158893","https://openalex.org/W1981325553","https://openalex.org/W2007869916","https://openalex.org/W2030712653","https://openalex.org/W2066087906","https://openalex.org/W2079720152","https://openalex.org/W2126460921","https://openalex.org/W2130178280","https://openalex.org/W2131072341","https://openalex.org/W2141367417","https://openalex.org/W2150888798","https://openalex.org/W2171379848","https://openalex.org/W2279902287","https://openalex.org/W2407733742","https://openalex.org/W2520962048","https://openalex.org/W2534024412","https://openalex.org/W6631964619","https://openalex.org/W6695338083","https://openalex.org/W6714231322","https://openalex.org/W6727474111"],"related_works":["https://openalex.org/W2766382465","https://openalex.org/W2784326067","https://openalex.org/W3017739981","https://openalex.org/W3194652096","https://openalex.org/W2358878017","https://openalex.org/W149558712","https://openalex.org/W2766995343","https://openalex.org/W2388178350","https://openalex.org/W2392597137","https://openalex.org/W4232850969"],"abstract_inverted_index":{"Loss-of-mains":[0],"(LoM)":[1],"protection":[2,83],"is":[3,48,70,75,141,148],"crucial":[4],"in":[5,114,131],"modern":[6],"smart":[7],"grids":[8,22],"(SGs),":[9],"where":[10,72],"the":[11,21,30,36,39,42,60,81,85,89,92,101,104,111,117,123,132,146],"number":[12],"of":[13,122,129],"distributed":[14],"generation":[15],"(DG)":[16],"units":[17],"has":[18],"increased":[19],"making":[20],"more":[23],"complex.":[24],"An":[25],"LoM":[26,68,82],"situation":[27],"means":[28],"that":[29],"DG":[31],"unit(s)":[32],"is/are":[33],"still":[34],"supplying":[35,43],"grid":[37,47,99],"while":[38],"connection":[40],"to":[41,55,59,100,138],"electric":[44],"power":[45,63],"distribution":[46],"off.":[49],"This":[50],"can":[51],"cause":[52],"fatal":[53],"injuries":[54],"humans":[56],"and":[57,95,120,150],"damages":[58],"equipment.":[61],"A":[62,143],"line":[64],"communication":[65],"(PLC)":[66],"based":[67],"concept":[69],"introduced,":[71],"continuous":[73],"signaling":[74],"used":[76],"as":[77,126],"an":[78],"indication":[79],"for":[80,110,145],"from":[84,135],"primary":[86],"substation":[87],"through":[88],"MV":[90],"grid,":[91],"MV/LV":[93,105,124],"transformers,":[94],"each":[96],"low-voltage":[97],"(LV)":[98],"customers.":[102],"However,":[103],"transformers":[106],"constitute":[107],"a":[108,127],"barrier":[109],"PLC.":[112],"Thus,":[113],"this":[115],"paper,":[116],"channel":[118],"characteristics":[119],"modeling":[121],"transformer":[125,147],"function":[128],"frequency":[130,133],"band":[134],"100":[136],"Hz":[137],"1":[139],"MHz":[140],"analyzed.":[142],"model":[144],"compiled":[149],"verified":[151],"by":[152],"input":[153],"impedance":[154],"measurements.":[155]},"counts_by_year":[{"year":2019,"cited_by_count":2},{"year":2018,"cited_by_count":1},{"year":2017,"cited_by_count":1},{"year":2016,"cited_by_count":1}],"updated_date":"2026-06-26T08:34:08.712188","created_date":"2025-10-10T00:00:00"}
