{"id":"https://openalex.org/W4391236608","doi":"https://doi.org/10.1109/ispec58282.2023.10402870","title":"Energy-saving Potential Assessment of Building Energy System Considering Climate Impacts","display_name":"Energy-saving Potential Assessment of Building Energy System Considering Climate Impacts","publication_year":2023,"publication_date":"2023-11-28","ids":{"openalex":"https://openalex.org/W4391236608","doi":"https://doi.org/10.1109/ispec58282.2023.10402870"},"language":"en","primary_location":{"id":"doi:10.1109/ispec58282.2023.10402870","is_oa":false,"landing_page_url":"http://dx.doi.org/10.1109/ispec58282.2023.10402870","pdf_url":null,"source":null,"license":null,"license_id":null,"version":"publishedVersion","is_accepted":true,"is_published":true,"raw_source_name":"2023 IEEE Sustainable Power and Energy Conference (iSPEC)","raw_type":"proceedings-article"},"type":"article","indexed_in":["crossref"],"open_access":{"is_oa":false,"oa_status":"closed","oa_url":null,"any_repository_has_fulltext":false},"authorships":[{"author_position":"first","author":{"id":"https://openalex.org/A5100744072","display_name":"Zhenwei Zhang","orcid":"https://orcid.org/0009-0001-2464-9248"},"institutions":[{"id":"https://openalex.org/I204512498","display_name":"University of Macau","ror":"https://ror.org/01r4q9n85","country_code":"MO","type":"education","lineage":["https://openalex.org/I204512498"]},{"id":"https://openalex.org/I4210165204","display_name":"Zhuhai Institute of Advanced Technology","ror":"https://ror.org/05r1mzq61","country_code":"CN","type":"facility","lineage":["https://openalex.org/I19820366","https://openalex.org/I4210145761","https://openalex.org/I4210165204"]},{"id":"https://openalex.org/I6469544","display_name":"City University of Macau","ror":"https://ror.org/04gpd4q15","country_code":"MO","type":"education","lineage":["https://openalex.org/I6469544"]}],"countries":["CN","MO"],"is_corresponding":true,"raw_author_name":"Zhenwei Zhang","raw_affiliation_strings":["University of Macau,State Key Laboratory of Internet of Things for Smart City,Macao,China,999078","Zhuhai UM Science Technology Research Institute, Zhuhai, China","Department of Electrical and Computer Engineering, University of Macau, Macao, China"],"affiliations":[{"raw_affiliation_string":"University of Macau,State Key Laboratory of Internet of Things for Smart City,Macao,China,999078","institution_ids":["https://openalex.org/I6469544","https://openalex.org/I204512498"]},{"raw_affiliation_string":"Zhuhai UM Science Technology Research Institute, Zhuhai, China","institution_ids":["https://openalex.org/I4210165204"]},{"raw_affiliation_string":"Department of Electrical and Computer Engineering, University of Macau, Macao, China","institution_ids":["https://openalex.org/I204512498"]}]},{"author_position":"last","author":{"id":"https://openalex.org/A5016579820","display_name":"Hongxun Hui","orcid":"https://orcid.org/0000-0002-2299-7580"},"institutions":[{"id":"https://openalex.org/I204512498","display_name":"University of Macau","ror":"https://ror.org/01r4q9n85","country_code":"MO","type":"education","lineage":["https://openalex.org/I204512498"]},{"id":"https://openalex.org/I4210165204","display_name":"Zhuhai Institute of Advanced Technology","ror":"https://ror.org/05r1mzq61","country_code":"CN","type":"facility","lineage":["https://openalex.org/I19820366","https://openalex.org/I4210145761","https://openalex.org/I4210165204"]},{"id":"https://openalex.org/I6469544","display_name":"City University of Macau","ror":"https://ror.org/04gpd4q15","country_code":"MO","type":"education","lineage":["https://openalex.org/I6469544"]}],"countries":["CN","MO"],"is_corresponding":false,"raw_author_name":"Hongxun Hui","raw_affiliation_strings":["University of Macau,State Key Laboratory of Internet of Things for Smart City,Macao,China,999078","Department of Electrical and Computer Engineering, University of Macau, Macao, China","Zhuhai UM Science Technology Research Institute, Zhuhai, China"],"affiliations":[{"raw_affiliation_string":"University of Macau,State Key Laboratory of Internet of Things for Smart City,Macao,China,999078","institution_ids":["https://openalex.org/I6469544","https://openalex.org/I204512498"]},{"raw_affiliation_string":"Department of Electrical and Computer Engineering, University of Macau, Macao, China","institution_ids":["https://openalex.org/I204512498"]},{"raw_affiliation_string":"Zhuhai UM Science Technology Research Institute, Zhuhai, China","institution_ids":["https://openalex.org/I4210165204"]}]}],"institutions":[],"countries_distinct_count":2,"institutions_distinct_count":2,"corresponding_author_ids":["https://openalex.org/A5100744072"],"corresponding_institution_ids":["https://openalex.org/I204512498","https://openalex.org/I4210165204","https://openalex.org/I6469544"],"apc_list":null,"apc_paid":null,"fwci":0.0,"has_fulltext":false,"cited_by_count":0,"citation_normalized_percentile":{"value":0.22422335,"is_in_top_1_percent":false,"is_in_top_10_percent":false},"cited_by_percentile_year":null,"biblio":{"volume":null,"issue":null,"first_page":"1","last_page":"5"},"is_retracted":false,"is_paratext":false,"is_xpac":false,"primary_topic":{"id":"https://openalex.org/T10121","display_name":"Building Energy and Comfort Optimization","score":0.9926999807357788,"subfield":{"id":"https://openalex.org/subfields/2215","display_name":"Building and Construction"},"field":{"id":"https://openalex.org/fields/22","display_name":"Engineering"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}},"topics":[{"id":"https://openalex.org/T10121","display_name":"Building Energy and Comfort Optimization","score":0.9926999807357788,"subfield":{"id":"https://openalex.org/subfields/2215","display_name":"Building and Construction"},"field":{"id":"https://openalex.org/fields/22","display_name":"Engineering"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}},{"id":"https://openalex.org/T10603","display_name":"Smart Grid Energy Management","score":0.989799976348877,"subfield":{"id":"https://openalex.org/subfields/2208","display_name":"Electrical and Electronic Engineering"},"field":{"id":"https://openalex.org/fields/22","display_name":"Engineering"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}},{"id":"https://openalex.org/T11185","display_name":"Integrated Energy Systems Optimization","score":0.9519000053405762,"subfield":{"id":"https://openalex.org/subfields/2208","display_name":"Electrical and Electronic Engineering"},"field":{"id":"https://openalex.org/fields/22","display_name":"Engineering"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}}],"keywords":[{"id":"https://openalex.org/keywords/energy","display_name":"Energy (signal processing)","score":0.6142667531967163},{"id":"https://openalex.org/keywords/environmental-science","display_name":"Environmental science","score":0.5318006873130798},{"id":"https://openalex.org/keywords/energy-system","display_name":"Energy system","score":0.4146798849105835},{"id":"https://openalex.org/keywords/computer-science","display_name":"Computer science","score":0.37393254041671753}],"concepts":[{"id":"https://openalex.org/C186370098","wikidata":"https://www.wikidata.org/wiki/Q442787","display_name":"Energy (signal processing)","level":2,"score":0.6142667531967163},{"id":"https://openalex.org/C39432304","wikidata":"https://www.wikidata.org/wiki/Q188847","display_name":"Environmental science","level":0,"score":0.5318006873130798},{"id":"https://openalex.org/C2781341389","wikidata":"https://www.wikidata.org/wiki/Q4531977","display_name":"Energy system","level":3,"score":0.4146798849105835},{"id":"https://openalex.org/C41008148","wikidata":"https://www.wikidata.org/wiki/Q21198","display_name":"Computer science","level":0,"score":0.37393254041671753},{"id":"https://openalex.org/C105795698","wikidata":"https://www.wikidata.org/wiki/Q12483","display_name":"Statistics","level":1,"score":0.0},{"id":"https://openalex.org/C33923547","wikidata":"https://www.wikidata.org/wiki/Q395","display_name":"Mathematics","level":0,"score":0.0}],"mesh":[],"locations_count":1,"locations":[{"id":"doi:10.1109/ispec58282.2023.10402870","is_oa":false,"landing_page_url":"http://dx.doi.org/10.1109/ispec58282.2023.10402870","pdf_url":null,"source":null,"license":null,"license_id":null,"version":"publishedVersion","is_accepted":true,"is_published":true,"raw_source_name":"2023 IEEE Sustainable Power and Energy Conference (iSPEC)","raw_type":"proceedings-article"}],"best_oa_location":null,"sustainable_development_goals":[{"display_name":"Climate action","score":0.5299999713897705,"id":"https://metadata.un.org/sdg/13"}],"awards":[],"funders":[{"id":"https://openalex.org/F4320321655","display_name":"Science and Technology Development Fund","ror":"https://ror.org/044vr6g03"}],"has_content":{"pdf":false,"grobid_xml":false},"content_urls":null,"referenced_works_count":13,"referenced_works":["https://openalex.org/W2563737383","https://openalex.org/W2920843795","https://openalex.org/W3133539597","https://openalex.org/W3157171212","https://openalex.org/W3157814197","https://openalex.org/W4211205532","https://openalex.org/W4226300926","https://openalex.org/W4366131873","https://openalex.org/W4368353791","https://openalex.org/W4380248707","https://openalex.org/W4380372926","https://openalex.org/W4380716477","https://openalex.org/W4380742871"],"related_works":["https://openalex.org/W2033164327","https://openalex.org/W164238414","https://openalex.org/W2331633775","https://openalex.org/W2490766011","https://openalex.org/W2103528018","https://openalex.org/W4285482523","https://openalex.org/W3156508385","https://openalex.org/W2501719106","https://openalex.org/W4221023619","https://openalex.org/W3164072880"],"abstract_inverted_index":{"Photovoltaic/thermal":[0],"integrated":[1],"system":[2,8,21],"(PV/T)":[3],"and":[4,12,36,62,77,93,104,148],"virtual":[5],"energy":[6,20],"storage":[7,105],"(VESS)":[9],"are":[10],"innovative":[11],"energy-saving":[13,43,55,124,152],"techniques":[14],"for":[15,101],"multi-energy":[16],"demand,":[17],"providing":[18],"building":[19,34,135],"(BES)":[22],"with":[23,52,115],"adjustable":[24],"potential.":[25],"However,":[26],"duo":[27],"to":[28,121],"inherent":[29],"deviations":[30],"in":[31,42,67,137],"climate":[32,60,88],"conditions,":[33],"demands":[35],"equipment":[37],"performance,":[38],"lack":[39],"of":[40,98,107,139,144],"confidence":[41],"potential":[44,56,153],"has":[45],"been":[46],"a":[47,71],"tricky":[48],"problem.":[49],"To":[50],"copy":[51],"that,":[53],"an":[54,111],"assessment":[57],"model":[58,74,114],"considering":[59],"conditions":[61,89],"user":[63,130],"satisfaction":[64],"is":[65,79,119],"proposed":[66,146],"this":[68],"paper.":[69],"First,":[70],"typical":[72],"BES":[73],"coupling":[75],"PV/T":[76,94],"VESS":[78],"established.":[80],"Meanwhile,":[81],"we":[82],"develop":[83],"numerical":[84],"relationships":[85],"between":[86],"varying":[87],"(solar":[90],"radiation,":[91],"temperature)":[92],"conversion":[95],"efficiency,":[96],"coefficient":[97],"performance":[99],"(COP)":[100],"air":[102],"conditioners,":[103],"capacity":[106],"VESS,":[108],"respectively.":[109],"Then,":[110],"optimal":[112],"dispatch":[113],"minimize":[116],"electricity":[117],"consumption":[118],"applied":[120],"assess":[122],"the":[123,129,142,145],"potential,":[125],"taking":[126],"into":[127],"account":[128],"satisfaction.":[131],"Simulation":[132],"results":[133],"on":[134],"block":[136],"University":[138],"Macau":[140],"demonstrate":[141],"effectiveness":[143],"method":[147],"verify":[149],"that":[150],"76%":[151],"can":[154],"be":[155],"achieved.":[156]},"counts_by_year":[],"updated_date":"2025-12-25T23:11:45.687758","created_date":"2025-10-10T00:00:00"}
