{"id":"https://openalex.org/W2027175222","doi":"https://doi.org/10.1109/ispass.2013.6557146","title":"An analytical framework for estimating TCO and exploring data center design space","display_name":"An analytical framework for estimating TCO and exploring data center design space","publication_year":2013,"publication_date":"2013-04-01","ids":{"openalex":"https://openalex.org/W2027175222","doi":"https://doi.org/10.1109/ispass.2013.6557146","mag":"2027175222"},"language":"en","primary_location":{"id":"doi:10.1109/ispass.2013.6557146","is_oa":false,"landing_page_url":"https://doi.org/10.1109/ispass.2013.6557146","pdf_url":null,"source":null,"license":null,"license_id":null,"version":"publishedVersion","is_accepted":true,"is_published":true,"raw_source_name":"2013 IEEE International Symposium on Performance Analysis of Systems and Software (ISPASS)","raw_type":"proceedings-article"},"type":"conference-paper","indexed_in":["crossref"],"open_access":{"is_oa":true,"oa_status":"green","oa_url":"https://zenodo.org/record/3432904","any_repository_has_fulltext":true},"authorships":[{"author_position":"first","author":{"id":"https://openalex.org/A5017665334","display_name":"Damien Hardy","orcid":null},"institutions":[{"id":"https://openalex.org/I34771391","display_name":"University of Cyprus","ror":"https://ror.org/02qjrjx09","country_code":"CY","type":"education","lineage":["https://openalex.org/I34771391"]}],"countries":["CY"],"is_corresponding":false,"raw_author_name":"Damien Hardy","raw_affiliation_strings":["University of Cyprus, Cyprus","University of Cyprus Nicosia Cyprus"],"raw_orcid":null,"affiliations":[{"raw_affiliation_string":"University of Cyprus, Cyprus","institution_ids":["https://openalex.org/I34771391"]},{"raw_affiliation_string":"University of Cyprus Nicosia Cyprus","institution_ids":["https://openalex.org/I34771391"]}]},{"author_position":"middle","author":{"id":"https://openalex.org/A5023975649","display_name":"Marios Kleanthous","orcid":null},"institutions":[{"id":"https://openalex.org/I34771391","display_name":"University of Cyprus","ror":"https://ror.org/02qjrjx09","country_code":"CY","type":"education","lineage":["https://openalex.org/I34771391"]}],"countries":["CY"],"is_corresponding":false,"raw_author_name":"Marios Kleanthous","raw_affiliation_strings":["University of Cyprus, Cyprus","University of Cyprus Nicosia Cyprus"],"raw_orcid":null,"affiliations":[{"raw_affiliation_string":"University of Cyprus, Cyprus","institution_ids":["https://openalex.org/I34771391"]},{"raw_affiliation_string":"University of Cyprus Nicosia Cyprus","institution_ids":["https://openalex.org/I34771391"]}]},{"author_position":"middle","author":{"id":"https://openalex.org/A5069705909","display_name":"Isidoros Sideris","orcid":null},"institutions":[{"id":"https://openalex.org/I34771391","display_name":"University of Cyprus","ror":"https://ror.org/02qjrjx09","country_code":"CY","type":"education","lineage":["https://openalex.org/I34771391"]}],"countries":["CY"],"is_corresponding":false,"raw_author_name":"Isidoros Sideris","raw_affiliation_strings":["University of Cyprus, Cyprus","University of Cyprus Nicosia Cyprus"],"raw_orcid":null,"affiliations":[{"raw_affiliation_string":"University of Cyprus, Cyprus","institution_ids":["https://openalex.org/I34771391"]},{"raw_affiliation_string":"University of Cyprus Nicosia Cyprus","institution_ids":["https://openalex.org/I34771391"]}]},{"author_position":"middle","author":{"id":"https://openalex.org/A5111875289","display_name":"\u0410\u043b\u0438 \u0421\u0430\u0438\u0434\u0438","orcid":null},"institutions":[{"id":"https://openalex.org/I4210156213","display_name":"American Rock Mechanics Association","ror":"https://ror.org/05vfrxy92","country_code":"US","type":"nonprofit","lineage":["https://openalex.org/I4210156213"]}],"countries":["US"],"is_corresponding":false,"raw_author_name":"Ali G. Saidi","raw_affiliation_strings":["ARM, USA","ARM, Cyprus"],"raw_orcid":null,"affiliations":[{"raw_affiliation_string":"ARM, USA","institution_ids":["https://openalex.org/I4210156213"]},{"raw_affiliation_string":"ARM, Cyprus","institution_ids":[]}]},{"author_position":"middle","author":{"id":"https://openalex.org/A5060902414","display_name":"Emre \u00d6zer","orcid":"https://orcid.org/0000-0001-8285-1551"},"institutions":[{"id":"https://openalex.org/I4210156213","display_name":"American Rock Mechanics Association","ror":"https://ror.org/05vfrxy92","country_code":"US","type":"nonprofit","lineage":["https://openalex.org/I4210156213"]}],"countries":["US"],"is_corresponding":false,"raw_author_name":"Emre Ozer","raw_affiliation_strings":["ARM, USA","ARM, Cyprus"],"raw_orcid":null,"affiliations":[{"raw_affiliation_string":"ARM, USA","institution_ids":["https://openalex.org/I4210156213"]},{"raw_affiliation_string":"ARM, Cyprus","institution_ids":[]}]},{"author_position":"last","author":{"id":"https://openalex.org/A5112557559","display_name":"Yiannakis Sazeides","orcid":null},"institutions":[{"id":"https://openalex.org/I34771391","display_name":"University of Cyprus","ror":"https://ror.org/02qjrjx09","country_code":"CY","type":"education","lineage":["https://openalex.org/I34771391"]}],"countries":["CY"],"is_corresponding":false,"raw_author_name":"Yiannakis Sazeides","raw_affiliation_strings":["University of Cyprus, Cyprus","University of Cyprus Nicosia Cyprus"],"raw_orcid":null,"affiliations":[{"raw_affiliation_string":"University of Cyprus, Cyprus","institution_ids":["https://openalex.org/I34771391"]},{"raw_affiliation_string":"University of Cyprus Nicosia Cyprus","institution_ids":["https://openalex.org/I34771391"]}]}],"institutions":[],"countries_distinct_count":2,"institutions_distinct_count":2,"corresponding_author_ids":[],"corresponding_institution_ids":[],"apc_list":null,"apc_paid":null,"fwci":1.7616,"has_fulltext":false,"cited_by_count":27,"citation_normalized_percentile":{"value":0.84892173,"is_in_top_1_percent":false,"is_in_top_10_percent":false},"cited_by_percentile_year":{"min":89,"max":98},"biblio":{"volume":null,"issue":null,"first_page":"54","last_page":"63"},"is_retracted":false,"is_paratext":false,"is_xpac":false,"primary_topic":{"id":"https://openalex.org/T10101","display_name":"Cloud Computing and Resource Management","score":0.9995999932289124,"subfield":{"id":"https://openalex.org/subfields/1710","display_name":"Information Systems"},"field":{"id":"https://openalex.org/fields/17","display_name":"Computer Science"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}},"topics":[{"id":"https://openalex.org/T10101","display_name":"Cloud Computing and Resource Management","score":0.9995999932289124,"subfield":{"id":"https://openalex.org/subfields/1710","display_name":"Information Systems"},"field":{"id":"https://openalex.org/fields/17","display_name":"Computer Science"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}},{"id":"https://openalex.org/T10054","display_name":"Parallel Computing and Optimization Techniques","score":0.9865000247955322,"subfield":{"id":"https://openalex.org/subfields/1708","display_name":"Hardware and Architecture"},"field":{"id":"https://openalex.org/fields/17","display_name":"Computer Science"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}},{"id":"https://openalex.org/T12238","display_name":"Green IT and Sustainability","score":0.9815999865531921,"subfield":{"id":"https://openalex.org/subfields/2208","display_name":"Electrical and Electronic Engineering"},"field":{"id":"https://openalex.org/fields/22","display_name":"Engineering"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}}],"keywords":[{"id":"https://openalex.org/keywords/mean-time-between-failures","display_name":"Mean time between failures","score":0.9300387501716614},{"id":"https://openalex.org/keywords/data-center","display_name":"Data center","score":0.765310525894165},{"id":"https://openalex.org/keywords/spare-part","display_name":"Spare part","score":0.7106480598449707},{"id":"https://openalex.org/keywords/computer-science","display_name":"Computer science","score":0.6924870014190674},{"id":"https://openalex.org/keywords/server","display_name":"Server","score":0.5222262144088745},{"id":"https://openalex.org/keywords/power-consumption","display_name":"Power consumption","score":0.4990963935852051},{"id":"https://openalex.org/keywords/reliability-engineering","display_name":"Reliability engineering","score":0.4896874725818634},{"id":"https://openalex.org/keywords/real-time-computing","display_name":"Real-time computing","score":0.4456350803375244},{"id":"https://openalex.org/keywords/cost-reduction","display_name":"Cost reduction","score":0.44152602553367615},{"id":"https://openalex.org/keywords/power","display_name":"Power (physics)","score":0.37834492325782776},{"id":"https://openalex.org/keywords/embedded-system","display_name":"Embedded system","score":0.34838271141052246},{"id":"https://openalex.org/keywords/failure-rate","display_name":"Failure rate","score":0.15887489914894104},{"id":"https://openalex.org/keywords/engineering","display_name":"Engineering","score":0.1544923186302185},{"id":"https://openalex.org/keywords/computer-network","display_name":"Computer network","score":0.15235167741775513},{"id":"https://openalex.org/keywords/operations-management","display_name":"Operations management","score":0.1360878348350525}],"concepts":[{"id":"https://openalex.org/C44154001","wikidata":"https://www.wikidata.org/wiki/Q754940","display_name":"Mean time between failures","level":3,"score":0.9300387501716614},{"id":"https://openalex.org/C153740404","wikidata":"https://www.wikidata.org/wiki/Q671224","display_name":"Data center","level":2,"score":0.765310525894165},{"id":"https://openalex.org/C194648553","wikidata":"https://www.wikidata.org/wiki/Q1364774","display_name":"Spare part","level":2,"score":0.7106480598449707},{"id":"https://openalex.org/C41008148","wikidata":"https://www.wikidata.org/wiki/Q21198","display_name":"Computer science","level":0,"score":0.6924870014190674},{"id":"https://openalex.org/C93996380","wikidata":"https://www.wikidata.org/wiki/Q44127","display_name":"Server","level":2,"score":0.5222262144088745},{"id":"https://openalex.org/C2984118289","wikidata":"https://www.wikidata.org/wiki/Q29954","display_name":"Power consumption","level":3,"score":0.4990963935852051},{"id":"https://openalex.org/C200601418","wikidata":"https://www.wikidata.org/wiki/Q2193887","display_name":"Reliability engineering","level":1,"score":0.4896874725818634},{"id":"https://openalex.org/C79403827","wikidata":"https://www.wikidata.org/wiki/Q3988","display_name":"Real-time computing","level":1,"score":0.4456350803375244},{"id":"https://openalex.org/C2778820799","wikidata":"https://www.wikidata.org/wiki/Q3454688","display_name":"Cost reduction","level":2,"score":0.44152602553367615},{"id":"https://openalex.org/C163258240","wikidata":"https://www.wikidata.org/wiki/Q25342","display_name":"Power (physics)","level":2,"score":0.37834492325782776},{"id":"https://openalex.org/C149635348","wikidata":"https://www.wikidata.org/wiki/Q193040","display_name":"Embedded system","level":1,"score":0.34838271141052246},{"id":"https://openalex.org/C163164238","wikidata":"https://www.wikidata.org/wiki/Q2737027","display_name":"Failure rate","level":2,"score":0.15887489914894104},{"id":"https://openalex.org/C127413603","wikidata":"https://www.wikidata.org/wiki/Q11023","display_name":"Engineering","level":0,"score":0.1544923186302185},{"id":"https://openalex.org/C31258907","wikidata":"https://www.wikidata.org/wiki/Q1301371","display_name":"Computer network","level":1,"score":0.15235167741775513},{"id":"https://openalex.org/C21547014","wikidata":"https://www.wikidata.org/wiki/Q1423657","display_name":"Operations management","level":1,"score":0.1360878348350525},{"id":"https://openalex.org/C62520636","wikidata":"https://www.wikidata.org/wiki/Q944","display_name":"Quantum mechanics","level":1,"score":0.0},{"id":"https://openalex.org/C121332964","wikidata":"https://www.wikidata.org/wiki/Q413","display_name":"Physics","level":0,"score":0.0},{"id":"https://openalex.org/C187736073","wikidata":"https://www.wikidata.org/wiki/Q2920921","display_name":"Management","level":1,"score":0.0},{"id":"https://openalex.org/C162324750","wikidata":"https://www.wikidata.org/wiki/Q8134","display_name":"Economics","level":0,"score":0.0}],"mesh":[],"locations_count":3,"locations":[{"id":"doi:10.1109/ispass.2013.6557146","is_oa":false,"landing_page_url":"https://doi.org/10.1109/ispass.2013.6557146","pdf_url":null,"source":null,"license":null,"license_id":null,"version":"publishedVersion","is_accepted":true,"is_published":true,"raw_source_name":"2013 IEEE International Symposium on Performance Analysis of Systems and Software (ISPASS)","raw_type":"proceedings-article"},{"id":"pmh:oai:HAL:hal-00914593v1","is_oa":false,"landing_page_url":"https://inria.hal.science/hal-00914593","pdf_url":null,"source":{"id":"https://openalex.org/S4306402512","display_name":"HAL (Le Centre pour la Communication Scientifique Directe)","issn_l":null,"issn":null,"is_oa":false,"is_in_doaj":false,"is_core":false,"host_organization":"https://openalex.org/I1294671590","host_organization_name":"Centre National de la Recherche Scientifique","host_organization_lineage":["https://openalex.org/I1294671590"],"host_organization_lineage_names":[],"type":"repository"},"license":null,"license_id":null,"version":"submittedVersion","is_accepted":false,"is_published":false,"raw_source_name":"IEEE International Symposium on Performance Analysis of Systems and Software, Apr 2013, Austin, United States","raw_type":"info:eu-repo/semantics/conferenceObject"},{"id":"pmh:oai:zenodo.org:3432904","is_oa":true,"landing_page_url":"https://zenodo.org/record/3432904","pdf_url":null,"source":{"id":"https://openalex.org/S4306400562","display_name":"Zenodo (CERN European Organization for Nuclear Research)","issn_l":null,"issn":null,"is_oa":true,"is_in_doaj":false,"is_core":false,"host_organization":"https://openalex.org/I67311998","host_organization_name":"European Organization for Nuclear Research","host_organization_lineage":["https://openalex.org/I67311998"],"host_organization_lineage_names":[],"type":"repository"},"license":"other-oa","license_id":"https://openalex.org/licenses/other-oa","version":"submittedVersion","is_accepted":false,"is_published":false,"raw_source_name":"","raw_type":"info:eu-repo/semantics/conferencePaper"}],"best_oa_location":{"id":"pmh:oai:zenodo.org:3432904","is_oa":true,"landing_page_url":"https://zenodo.org/record/3432904","pdf_url":null,"source":{"id":"https://openalex.org/S4306400562","display_name":"Zenodo (CERN European Organization for Nuclear Research)","issn_l":null,"issn":null,"is_oa":true,"is_in_doaj":false,"is_core":false,"host_organization":"https://openalex.org/I67311998","host_organization_name":"European Organization for Nuclear Research","host_organization_lineage":["https://openalex.org/I67311998"],"host_organization_lineage_names":[],"type":"repository"},"license":"other-oa","license_id":"https://openalex.org/licenses/other-oa","version":"submittedVersion","is_accepted":false,"is_published":false,"raw_source_name":"","raw_type":"info:eu-repo/semantics/conferencePaper"},"sustainable_development_goals":[],"awards":[],"funders":[{"id":"https://openalex.org/F4320320300","display_name":"European Commission","ror":"https://ror.org/00k4n6c32"}],"has_content":{"pdf":false,"grobid_xml":false},"content_urls":null,"referenced_works_count":33,"referenced_works":["https://openalex.org/W190397983","https://openalex.org/W1971394347","https://openalex.org/W1972356182","https://openalex.org/W1979361375","https://openalex.org/W1998474435","https://openalex.org/W2035286849","https://openalex.org/W2055077314","https://openalex.org/W2060204338","https://openalex.org/W2065439108","https://openalex.org/W2068115084","https://openalex.org/W2075653320","https://openalex.org/W2079787774","https://openalex.org/W2100346277","https://openalex.org/W2101221989","https://openalex.org/W2121288607","https://openalex.org/W2131413854","https://openalex.org/W2135232880","https://openalex.org/W2144857621","https://openalex.org/W2146280492","https://openalex.org/W2146434221","https://openalex.org/W2149781994","https://openalex.org/W2150139096","https://openalex.org/W2156897479","https://openalex.org/W2160204571","https://openalex.org/W2165071510","https://openalex.org/W2165473669","https://openalex.org/W2616747538","https://openalex.org/W3150290710","https://openalex.org/W4231523873","https://openalex.org/W4233484638","https://openalex.org/W6607690699","https://openalex.org/W6664229618","https://openalex.org/W6683445388"],"related_works":["https://openalex.org/W2376859990","https://openalex.org/W2912704652","https://openalex.org/W2381161177","https://openalex.org/W2319226115","https://openalex.org/W830772239","https://openalex.org/W1983353130","https://openalex.org/W2970750595","https://openalex.org/W2366601680","https://openalex.org/W4295074292","https://openalex.org/W2392193501"],"abstract_inverted_index":{"In":[0],"this":[1,99],"paper,":[2],"we":[3],"present":[4],"EETCO:":[5],"an":[6],"estimation":[7,49],"and":[8,23,39,56,65,68,86,105,117,125,177,189],"exploration":[9,121],"tool":[10,43,63],"that":[11,71],"provides":[12],"qualitative":[13],"assessment":[14],"of":[15,31],"data":[16,94],"center":[17,95],"design":[18],"decisions":[19],"on":[20],"Total-Cost-of-Ownership":[21],"(TCO)":[22],"environmental":[24,127,168],"impact.":[25],"It":[26],"can":[27,193],"capture":[28],"the":[29,62,93,108,126,162,167,175],"implications":[30],"many":[32],"parameters":[33],"including":[34],"server":[35,54,77],"performance,":[36],"power,":[37],"cost,":[38],"Mean-Time-To-Failure":[40],"(MTTF).":[41],"The":[42,59],"includes":[44],"a":[45,138,152,171,179,183,197,204],"model":[46,64],"for":[47,53,92,103,182],"spare":[48],"needed":[50],"to":[51,122],"account":[52],"failures":[55],"performance":[57,79,116,130,206],"variability.":[58],"paper":[60],"describes":[61],"its":[66],"implementation,":[67],"presents":[69],"experiments":[70,90],"explore":[72],"tradeoffs":[73],"offered":[74],"by":[75,159],"different":[76,114],"configurations,":[78],"variability,":[80],"MTTF,":[81],"2D":[82,199],"vs":[83],"3D-stacked":[84,184],"processors,":[85],"ambient":[87,163],"temperature.":[88],"These":[89],"reveal,":[91],"configurations":[96],"used":[97],"in":[98,107,174],"study,":[100],"several":[101],"opportunities":[102],"profit":[104],"optimization":[106],"datacenter":[109,164],"ecosystem:":[110],"(i)":[111],"servers":[112],"with":[113,137,151,170,186],"computing":[115],"power":[118,191],"consumption":[119,192],"merit":[120],"minimize":[123],"TCO":[124,176],"impact,":[128],"(ii)":[129],"variability":[131],"is":[132,146],"desirable":[133],"if":[134,148,201],"it":[135,149,202],"comes":[136,150],"drastic":[139],"cost":[140,155,181],"reduction,":[141,156],"(iii)":[142],"shorter":[143,187],"processor":[144,154,185],"MTTF":[145,188],"beneficial":[147],"moderate":[153,205],"(iv)":[157],"increasing":[158],"few":[160],"degrees":[161],"temperature":[165],"reduces":[166],"impact":[169],"minor":[172],"increase":[173],"(v)":[178],"higher":[180,190],"be":[194],"preferred,":[195],"over":[196],"conventional":[198],"processor,":[200],"offers":[203],"increase.":[207]},"counts_by_year":[{"year":2025,"cited_by_count":1},{"year":2024,"cited_by_count":1},{"year":2023,"cited_by_count":2},{"year":2022,"cited_by_count":2},{"year":2021,"cited_by_count":1},{"year":2020,"cited_by_count":3},{"year":2019,"cited_by_count":5},{"year":2018,"cited_by_count":1},{"year":2017,"cited_by_count":4},{"year":2016,"cited_by_count":2},{"year":2015,"cited_by_count":5}],"updated_date":"2026-07-29T14:22:42.915294","created_date":"2016-06-24T00:00:00"}
