{"id":"https://openalex.org/W2617819196","doi":"https://doi.org/10.1109/isie.2017.8001506","title":"Enhancing the provision of ancillary services from storage systems using smart transformer and smart meters","display_name":"Enhancing the provision of ancillary services from storage systems using smart transformer and smart meters","publication_year":2017,"publication_date":"2017-06-01","ids":{"openalex":"https://openalex.org/W2617819196","doi":"https://doi.org/10.1109/isie.2017.8001506","mag":"2617819196"},"language":"en","primary_location":{"id":"doi:10.1109/isie.2017.8001506","is_oa":false,"landing_page_url":"https://doi.org/10.1109/isie.2017.8001506","pdf_url":null,"source":null,"license":null,"license_id":null,"version":"publishedVersion","is_accepted":true,"is_published":true,"raw_source_name":"2017 IEEE 26th International Symposium on Industrial Electronics (ISIE)","raw_type":"proceedings-article"},"type":"preprint","indexed_in":["crossref"],"open_access":{"is_oa":true,"oa_status":"green","oa_url":"https://nbn-resolving.org/urn:nbn:de:gbv:8-publ-19574","any_repository_has_fulltext":true},"authorships":[{"author_position":"first","author":{"id":"https://openalex.org/A5013233168","display_name":"Fabrizio Sossan","orcid":"https://orcid.org/0000-0002-7990-1471"},"institutions":[{"id":"https://openalex.org/I5124864","display_name":"\u00c9cole Polytechnique F\u00e9d\u00e9rale de Lausanne","ror":"https://ror.org/02s376052","country_code":"CH","type":"education","lineage":["https://openalex.org/I2799323385","https://openalex.org/I5124864"]}],"countries":["CH"],"is_corresponding":false,"raw_author_name":"Fabrizio Sossan","raw_affiliation_strings":["Ecole Poly technique F\u00e9d\u00e9rale de Lausanne (EPFL), Distributed Electrical Systems Laboratory, Lausanne, Switzerland"],"raw_orcid":null,"affiliations":[{"raw_affiliation_string":"Ecole Poly technique F\u00e9d\u00e9rale de Lausanne (EPFL), Distributed Electrical Systems Laboratory, Lausanne, Switzerland","institution_ids":["https://openalex.org/I5124864"]}]},{"author_position":"middle","author":{"id":"https://openalex.org/A5019522963","display_name":"Konstantina Christakou","orcid":"https://orcid.org/0000-0001-6060-2466"},"institutions":[{"id":"https://openalex.org/I5124864","display_name":"\u00c9cole Polytechnique F\u00e9d\u00e9rale de Lausanne","ror":"https://ror.org/02s376052","country_code":"CH","type":"education","lineage":["https://openalex.org/I2799323385","https://openalex.org/I5124864"]}],"countries":["CH"],"is_corresponding":false,"raw_author_name":"Konstantina Christakou","raw_affiliation_strings":["Ecole Poly technique F\u00e9d\u00e9rale de Lausanne (EPFL), Distributed Electrical Systems Laboratory, Lausanne, Switzerland"],"raw_orcid":null,"affiliations":[{"raw_affiliation_string":"Ecole Poly technique F\u00e9d\u00e9rale de Lausanne (EPFL), Distributed Electrical Systems Laboratory, Lausanne, Switzerland","institution_ids":["https://openalex.org/I5124864"]}]},{"author_position":"middle","author":{"id":"https://openalex.org/A5050504092","display_name":"Mario Paolone","orcid":"https://orcid.org/0000-0001-7073-9036"},"institutions":[{"id":"https://openalex.org/I5124864","display_name":"\u00c9cole Polytechnique F\u00e9d\u00e9rale de Lausanne","ror":"https://ror.org/02s376052","country_code":"CH","type":"education","lineage":["https://openalex.org/I2799323385","https://openalex.org/I5124864"]}],"countries":["CH"],"is_corresponding":false,"raw_author_name":"Mario Paolone","raw_affiliation_strings":["Ecole Poly technique F\u00e9d\u00e9rale de Lausanne (EPFL), Distributed Electrical Systems Laboratory, Lausanne, Switzerland"],"raw_orcid":null,"affiliations":[{"raw_affiliation_string":"Ecole Poly technique F\u00e9d\u00e9rale de Lausanne (EPFL), Distributed Electrical Systems Laboratory, Lausanne, Switzerland","institution_ids":["https://openalex.org/I5124864"]}]},{"author_position":"middle","author":{"id":"https://openalex.org/A5102017975","display_name":"Xiang Gao","orcid":"https://orcid.org/0000-0002-5473-5497"},"institutions":[{"id":"https://openalex.org/I32021983","display_name":"Christian-Albrechts-Universit\u00e4t zu Kiel","ror":"https://ror.org/04v76ef78","country_code":"DE","type":"education","lineage":["https://openalex.org/I32021983"]}],"countries":["DE"],"is_corresponding":false,"raw_author_name":"Xiang Gao","raw_affiliation_strings":["Chair of Power Electronics Christian Albrechts Universit\u00e4t zu kiel, Kiel, Germany"],"raw_orcid":null,"affiliations":[{"raw_affiliation_string":"Chair of Power Electronics Christian Albrechts Universit\u00e4t zu kiel, Kiel, Germany","institution_ids":["https://openalex.org/I32021983"]}]},{"author_position":"last","author":{"id":"https://openalex.org/A5053880143","display_name":"Marco Liserre","orcid":"https://orcid.org/0000-0002-0818-2684"},"institutions":[{"id":"https://openalex.org/I32021983","display_name":"Christian-Albrechts-Universit\u00e4t zu Kiel","ror":"https://ror.org/04v76ef78","country_code":"DE","type":"education","lineage":["https://openalex.org/I32021983"]}],"countries":["DE"],"is_corresponding":false,"raw_author_name":"Marco Liserre","raw_affiliation_strings":["Chair of Power Electronics Christian Albrechts Universit\u00e4t zu kiel, Kiel, Germany"],"raw_orcid":null,"affiliations":[{"raw_affiliation_string":"Chair of Power Electronics Christian Albrechts Universit\u00e4t zu kiel, Kiel, Germany","institution_ids":["https://openalex.org/I32021983"]}]}],"institutions":[],"countries_distinct_count":2,"institutions_distinct_count":5,"corresponding_author_ids":[],"corresponding_institution_ids":[],"apc_list":null,"apc_paid":null,"fwci":0.6123,"has_fulltext":true,"cited_by_count":5,"citation_normalized_percentile":{"value":0.6876465,"is_in_top_1_percent":false,"is_in_top_10_percent":false},"cited_by_percentile_year":{"min":90,"max":96},"biblio":{"volume":null,"issue":null,"first_page":"1715","last_page":"1720"},"is_retracted":false,"is_paratext":false,"is_xpac":false,"primary_topic":{"id":"https://openalex.org/T10223","display_name":"Microgrid Control and Optimization","score":0.9998999834060669,"subfield":{"id":"https://openalex.org/subfields/2207","display_name":"Control and Systems Engineering"},"field":{"id":"https://openalex.org/fields/22","display_name":"Engineering"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}},"topics":[{"id":"https://openalex.org/T10223","display_name":"Microgrid Control and Optimization","score":0.9998999834060669,"subfield":{"id":"https://openalex.org/subfields/2207","display_name":"Control and Systems Engineering"},"field":{"id":"https://openalex.org/fields/22","display_name":"Engineering"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}},{"id":"https://openalex.org/T10603","display_name":"Smart Grid Energy Management","score":0.9980999827384949,"subfield":{"id":"https://openalex.org/subfields/2208","display_name":"Electrical and Electronic Engineering"},"field":{"id":"https://openalex.org/fields/22","display_name":"Engineering"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}},{"id":"https://openalex.org/T10175","display_name":"Advanced DC-DC Converters","score":0.9979000091552734,"subfield":{"id":"https://openalex.org/subfields/2208","display_name":"Electrical and Electronic Engineering"},"field":{"id":"https://openalex.org/fields/22","display_name":"Engineering"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}}],"keywords":[{"id":"https://openalex.org/keywords/smart-grid","display_name":"Smart grid","score":0.7850183844566345},{"id":"https://openalex.org/keywords/transformer","display_name":"Transformer","score":0.7347127199172974},{"id":"https://openalex.org/keywords/computer-science","display_name":"Computer science","score":0.5441608428955078},{"id":"https://openalex.org/keywords/grid","display_name":"Grid","score":0.5159457325935364},{"id":"https://openalex.org/keywords/network-topology","display_name":"Network topology","score":0.5132508277893066},{"id":"https://openalex.org/keywords/ac-power","display_name":"AC power","score":0.46223360300064087},{"id":"https://openalex.org/keywords/voltage","display_name":"Voltage","score":0.4367212653160095},{"id":"https://openalex.org/keywords/electrical-engineering","display_name":"Electrical engineering","score":0.43065541982650757},{"id":"https://openalex.org/keywords/engineering","display_name":"Engineering","score":0.3431028723716736},{"id":"https://openalex.org/keywords/reliability-engineering","display_name":"Reliability engineering","score":0.33071666955947876},{"id":"https://openalex.org/keywords/computer-network","display_name":"Computer network","score":0.2307223379611969}],"concepts":[{"id":"https://openalex.org/C10558101","wikidata":"https://www.wikidata.org/wiki/Q689855","display_name":"Smart grid","level":2,"score":0.7850183844566345},{"id":"https://openalex.org/C66322947","wikidata":"https://www.wikidata.org/wiki/Q11658","display_name":"Transformer","level":3,"score":0.7347127199172974},{"id":"https://openalex.org/C41008148","wikidata":"https://www.wikidata.org/wiki/Q21198","display_name":"Computer science","level":0,"score":0.5441608428955078},{"id":"https://openalex.org/C187691185","wikidata":"https://www.wikidata.org/wiki/Q2020720","display_name":"Grid","level":2,"score":0.5159457325935364},{"id":"https://openalex.org/C199845137","wikidata":"https://www.wikidata.org/wiki/Q145490","display_name":"Network topology","level":2,"score":0.5132508277893066},{"id":"https://openalex.org/C108755667","wikidata":"https://www.wikidata.org/wiki/Q1930258","display_name":"AC power","level":3,"score":0.46223360300064087},{"id":"https://openalex.org/C165801399","wikidata":"https://www.wikidata.org/wiki/Q25428","display_name":"Voltage","level":2,"score":0.4367212653160095},{"id":"https://openalex.org/C119599485","wikidata":"https://www.wikidata.org/wiki/Q43035","display_name":"Electrical engineering","level":1,"score":0.43065541982650757},{"id":"https://openalex.org/C127413603","wikidata":"https://www.wikidata.org/wiki/Q11023","display_name":"Engineering","level":0,"score":0.3431028723716736},{"id":"https://openalex.org/C200601418","wikidata":"https://www.wikidata.org/wiki/Q2193887","display_name":"Reliability engineering","level":1,"score":0.33071666955947876},{"id":"https://openalex.org/C31258907","wikidata":"https://www.wikidata.org/wiki/Q1301371","display_name":"Computer network","level":1,"score":0.2307223379611969},{"id":"https://openalex.org/C2524010","wikidata":"https://www.wikidata.org/wiki/Q8087","display_name":"Geometry","level":1,"score":0.0},{"id":"https://openalex.org/C33923547","wikidata":"https://www.wikidata.org/wiki/Q395","display_name":"Mathematics","level":0,"score":0.0}],"mesh":[],"locations_count":6,"locations":[{"id":"doi:10.1109/isie.2017.8001506","is_oa":false,"landing_page_url":"https://doi.org/10.1109/isie.2017.8001506","pdf_url":null,"source":null,"license":null,"license_id":null,"version":"publishedVersion","is_accepted":true,"is_published":true,"raw_source_name":"2017 IEEE 26th International Symposium on Industrial Electronics (ISIE)","raw_type":"proceedings-article"},{"id":"pmh:oai:macau.uni-kiel.de:publ_mods_00001957","is_oa":true,"landing_page_url":"https://macau.uni-kiel.de/receive/publ_mods_00001957","pdf_url":"https://nbn-resolving.org/urn:nbn:de:gbv:8-publ-19574","source":{"id":"https://openalex.org/S4306401923","display_name":"Multimedialer Archiv- und Publikationsserver der Christian-Albrechts-Universit\u00e4t zu Kiel (Christian-Albrechts-Universit\u00e4t zu Kiel)","issn_l":null,"issn":null,"is_oa":false,"is_in_doaj":false,"is_core":false,"host_organization":"https://openalex.org/I151221077","host_organization_name":"Chung Yuan Christian University","host_organization_lineage":["https://openalex.org/I151221077"],"host_organization_lineage_names":[],"type":"repository"},"license":null,"license_id":null,"version":"submittedVersion","is_accepted":false,"is_published":false,"raw_source_name":null,"raw_type":"doc-type:BookPart"},{"id":"pmh:oai:HAL:hal-02108731v1","is_oa":true,"landing_page_url":"https://hal.science/hal-02108731","pdf_url":null,"source":{"id":"https://openalex.org/S4306402512","display_name":"HAL (Le Centre pour la Communication Scientifique Directe)","issn_l":null,"issn":null,"is_oa":false,"is_in_doaj":false,"is_core":false,"host_organization":"https://openalex.org/I1294671590","host_organization_name":"Centre National de la Recherche Scientifique","host_organization_lineage":["https://openalex.org/I1294671590"],"host_organization_lineage_names":[],"type":"repository"},"license":"other-oa","license_id":"https://openalex.org/licenses/other-oa","version":"submittedVersion","is_accepted":false,"is_published":false,"raw_source_name":"2017 IEEE 26th International Symposium on Industrial Electronics (ISIE), Jun 2017, Edinburgh, United Kingdom. pp.1715-1720","raw_type":"Conference papers"},{"id":"pmh:oai:infoscience.epfl.ch:228294","is_oa":true,"landing_page_url":"http://infoscience.epfl.ch/record/228294","pdf_url":null,"source":{"id":"https://openalex.org/S4306400487","display_name":"Infoscience (Ecole Polytechnique F\u00e9d\u00e9rale de Lausanne)","issn_l":null,"issn":null,"is_oa":true,"is_in_doaj":false,"is_core":false,"host_organization":null,"host_organization_name":null,"host_organization_lineage":[],"host_organization_lineage_names":[],"type":"repository"},"license":null,"license_id":null,"version":"submittedVersion","is_accepted":false,"is_published":false,"raw_source_name":"","raw_type":"Text"},{"id":"pmh:oai:infoscience.tind.io:228294","is_oa":true,"landing_page_url":"https://infoscience.epfl.ch/handle/20.500.14299/137467","pdf_url":null,"source":{"id":"https://openalex.org/S4306400487","display_name":"Infoscience (Ecole Polytechnique F\u00e9d\u00e9rale de Lausanne)","issn_l":null,"issn":null,"is_oa":true,"is_in_doaj":false,"is_core":false,"host_organization":null,"host_organization_name":null,"host_organization_lineage":[],"host_organization_lineage_names":[],"type":"repository"},"license":"cc-by-nc-nd","license_id":"https://openalex.org/licenses/cc-by-nc-nd","version":"submittedVersion","is_accepted":false,"is_published":false,"raw_source_name":"","raw_type":"conference proceedings"},{"id":"pmh:oai:macau.uni-kiel.de:macau_publ_00001957","is_oa":true,"landing_page_url":"https://macau.uni-kiel.de/receive/macau_publ_00001957","pdf_url":null,"source":{"id":"https://openalex.org/S4306401923","display_name":"Multimedialer Archiv- und Publikationsserver der Christian-Albrechts-Universit\u00e4t zu Kiel (Christian-Albrechts-Universit\u00e4t zu Kiel)","issn_l":null,"issn":null,"is_oa":false,"is_in_doaj":false,"is_core":false,"host_organization":"https://openalex.org/I151221077","host_organization_name":"Chung Yuan Christian University","host_organization_lineage":["https://openalex.org/I151221077"],"host_organization_lineage_names":[],"type":"repository"},"license":"other-oa","license_id":"https://openalex.org/licenses/other-oa","version":"submittedVersion","is_accepted":false,"is_published":false,"raw_source_name":"2017 IEEE 26th International Symposium on Industrial Electronics (ISIE). - Edinburgh : IEEE; 2017. - S.1715-1720.","raw_type":"doc-type:bookPart"}],"best_oa_location":{"id":"pmh:oai:macau.uni-kiel.de:publ_mods_00001957","is_oa":true,"landing_page_url":"https://macau.uni-kiel.de/receive/publ_mods_00001957","pdf_url":"https://nbn-resolving.org/urn:nbn:de:gbv:8-publ-19574","source":{"id":"https://openalex.org/S4306401923","display_name":"Multimedialer Archiv- und Publikationsserver der Christian-Albrechts-Universit\u00e4t zu Kiel (Christian-Albrechts-Universit\u00e4t zu Kiel)","issn_l":null,"issn":null,"is_oa":false,"is_in_doaj":false,"is_core":false,"host_organization":"https://openalex.org/I151221077","host_organization_name":"Chung Yuan Christian University","host_organization_lineage":["https://openalex.org/I151221077"],"host_organization_lineage_names":[],"type":"repository"},"license":null,"license_id":null,"version":"submittedVersion","is_accepted":false,"is_published":false,"raw_source_name":null,"raw_type":"doc-type:BookPart"},"sustainable_development_goals":[{"display_name":"Affordable and clean energy","id":"https://metadata.un.org/sdg/7","score":0.7599999904632568}],"awards":[],"funders":[],"has_content":{"grobid_xml":true,"pdf":true},"content_urls":{"pdf":"https://content.openalex.org/works/W2617819196.pdf","grobid_xml":"https://content.openalex.org/works/W2617819196.grobid-xml"},"referenced_works_count":22,"referenced_works":["https://openalex.org/W1971154039","https://openalex.org/W1974644684","https://openalex.org/W1980364886","https://openalex.org/W2016989559","https://openalex.org/W2060472803","https://openalex.org/W2098342537","https://openalex.org/W2100682478","https://openalex.org/W2112948692","https://openalex.org/W2126809563","https://openalex.org/W2146531934","https://openalex.org/W2158119364","https://openalex.org/W2164155926","https://openalex.org/W2261625295","https://openalex.org/W2427306935","https://openalex.org/W2438616010","https://openalex.org/W2442002586","https://openalex.org/W2515178891","https://openalex.org/W2529186219","https://openalex.org/W2567349745","https://openalex.org/W4236451413","https://openalex.org/W4251645464","https://openalex.org/W6731638876"],"related_works":["https://openalex.org/W2086397253","https://openalex.org/W2133122801","https://openalex.org/W4312311708","https://openalex.org/W600422426","https://openalex.org/W2007156430","https://openalex.org/W2157275880","https://openalex.org/W3081478936","https://openalex.org/W2751256511","https://openalex.org/W2785612136","https://openalex.org/W2006004274"],"abstract_inverted_index":{"The":[0,103,180,205],"Smart":[1],"Transformer,":[2],"a":[3,48,52,119,155,159],"solid-state":[4],"transformer":[5,55],"with":[6,57,130],"control":[7,49],"and":[8,81,88,100,158,170,197,213,227],"communication":[9],"functionalities,":[10],"can":[11],"be":[12],"the":[13,20,24,27,43,66,71,77,93,109,114,122,125,131,135,143,149,166,177,192,195,199,202,211,214,221,228],"ideal":[14],"solution":[15],"for":[16,51],"integrating":[17,198],"storage":[18,59,178],"into":[19],"grid.":[21,144],"By":[22],"leveraging":[23],"knowledge":[25],"of":[26,30,65,85,97,113,133,137,151,176,194],"grid":[28,196],"state":[29,193],"distribution":[31],"grids":[32],"thanks":[33],"to":[34,60,118,141,153,162],"smart":[35,54],"meters":[36],"and/or":[37],"dedicated":[38],"remote":[39],"terminal":[40],"units,":[41],"in":[42,164,210],"paper,":[44,212],"it":[45],"is":[46,105,146,182,208,216],"proposed":[47],"strategy":[50],"MV/LV":[53],"(ST)":[56],"integrated":[58],"achieve:":[61],"i)":[62],"dispatched-by-design":[63],"operation":[64],"LV":[67,89,99,115],"network":[68,116,203],"by":[69,91,107,173,184,218],"controlling":[70,92],"ST":[72],"active":[73,110],"power":[74,79,95,111,139],"set-point":[75],"on":[76,148,201],"MV":[78,87,101],"converter,":[80],"ii)":[82],"voltage":[83],"regulation":[84],"both":[86,98],"networks":[90],"reactive":[94],"injections":[96],"converter.":[102],"former":[104],"achieved":[106,183],"dispatching":[108],"flow":[112],"according":[117],"profile":[120],"established":[121],"day":[123],"before":[124],"operation,":[126],"called":[127],"dispatch":[128,156,171],"plan,":[129,157],"objective":[132],"reducing":[134],"amount":[136],"regulating":[138],"required":[140],"operate":[142],"It":[145],"based":[147],"use":[150],"forecast":[152],"compute":[154],"tracking":[160],"problem":[161,206],"compensate":[163],"real-time":[165],"mismatch":[167],"between":[168],"realization":[169],"plan":[172],"taking":[174],"advantage":[175],"capacity.":[179],"latter":[181],"using":[185,220],"sensitivity":[186],"coefficients,":[187],"which":[188],"are":[189],"calculated":[190],"from":[191],"information":[200],"topology.":[204],"formulation":[207],"given":[209],"proof-of-concept":[215],"shown":[217],"simulation":[219],"IEEE":[222],"34":[223],"nodes":[224],"test":[225],"feeder":[226],"CIGRE":[229],"Low":[230],"Voltage":[231],"reference":[232],"network.":[233]},"counts_by_year":[{"year":2025,"cited_by_count":1},{"year":2024,"cited_by_count":1},{"year":2019,"cited_by_count":2},{"year":2018,"cited_by_count":1}],"updated_date":"2026-06-11T09:08:48.828518","created_date":"2025-10-10T00:00:00"}
