{"id":"https://openalex.org/W2742339120","doi":"https://doi.org/10.1109/isie.2017.8001444","title":"A low-cost smart sensor for non intrusive load monitoring applications","display_name":"A low-cost smart sensor for non intrusive load monitoring applications","publication_year":2017,"publication_date":"2017-06-01","ids":{"openalex":"https://openalex.org/W2742339120","doi":"https://doi.org/10.1109/isie.2017.8001444","mag":"2742339120"},"language":"en","primary_location":{"id":"doi:10.1109/isie.2017.8001444","is_oa":false,"landing_page_url":"https://doi.org/10.1109/isie.2017.8001444","pdf_url":null,"source":null,"license":null,"license_id":null,"version":"publishedVersion","is_accepted":true,"is_published":true,"raw_source_name":"2017 IEEE 26th International Symposium on Industrial Electronics (ISIE)","raw_type":"proceedings-article"},"type":"article","indexed_in":["crossref"],"open_access":{"is_oa":false,"oa_status":"closed","oa_url":null,"any_repository_has_fulltext":false},"authorships":[{"author_position":"first","author":{"id":"https://openalex.org/A5027618321","display_name":"Matteo Nardello","orcid":"https://orcid.org/0000-0003-3126-1177"},"institutions":[{"id":"https://openalex.org/I193223587","display_name":"University of Trento","ror":"https://ror.org/05trd4x28","country_code":"IT","type":"education","lineage":["https://openalex.org/I193223587"]}],"countries":["IT"],"is_corresponding":true,"raw_author_name":"Matteo Nardello","raw_affiliation_strings":["Department of Industrial Engineering, DII University of Trento, Italy"],"affiliations":[{"raw_affiliation_string":"Department of Industrial Engineering, DII University of Trento, Italy","institution_ids":["https://openalex.org/I193223587"]}]},{"author_position":"middle","author":{"id":"https://openalex.org/A5006429085","display_name":"Maurizio Rossi","orcid":"https://orcid.org/0000-0002-3537-8914"},"institutions":[{"id":"https://openalex.org/I193223587","display_name":"University of Trento","ror":"https://ror.org/05trd4x28","country_code":"IT","type":"education","lineage":["https://openalex.org/I193223587"]}],"countries":["IT"],"is_corresponding":false,"raw_author_name":"Maurizio Rossi","raw_affiliation_strings":["Department of Industrial Engineering, DII University of Trento, Italy"],"affiliations":[{"raw_affiliation_string":"Department of Industrial Engineering, DII University of Trento, Italy","institution_ids":["https://openalex.org/I193223587"]}]},{"author_position":"last","author":{"id":"https://openalex.org/A5030075617","display_name":"Davide Brunelli","orcid":"https://orcid.org/0000-0001-5110-6823"},"institutions":[{"id":"https://openalex.org/I193223587","display_name":"University of Trento","ror":"https://ror.org/05trd4x28","country_code":"IT","type":"education","lineage":["https://openalex.org/I193223587"]}],"countries":["IT"],"is_corresponding":false,"raw_author_name":"Davide Brunelli","raw_affiliation_strings":["Department of Industrial Engineering, DII University of Trento, Italy"],"affiliations":[{"raw_affiliation_string":"Department of Industrial Engineering, DII University of Trento, Italy","institution_ids":["https://openalex.org/I193223587"]}]}],"institutions":[],"countries_distinct_count":1,"institutions_distinct_count":3,"corresponding_author_ids":["https://openalex.org/A5027618321"],"corresponding_institution_ids":["https://openalex.org/I193223587"],"apc_list":null,"apc_paid":null,"fwci":1.4565,"has_fulltext":false,"cited_by_count":14,"citation_normalized_percentile":{"value":0.83378302,"is_in_top_1_percent":false,"is_in_top_10_percent":false},"cited_by_percentile_year":{"min":89,"max":97},"biblio":{"volume":null,"issue":null,"first_page":"1362","last_page":"1368"},"is_retracted":false,"is_paratext":false,"is_xpac":false,"primary_topic":{"id":"https://openalex.org/T10603","display_name":"Smart Grid Energy Management","score":0.9998999834060669,"subfield":{"id":"https://openalex.org/subfields/2208","display_name":"Electrical and Electronic Engineering"},"field":{"id":"https://openalex.org/fields/22","display_name":"Engineering"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}},"topics":[{"id":"https://openalex.org/T10603","display_name":"Smart Grid Energy Management","score":0.9998999834060669,"subfield":{"id":"https://openalex.org/subfields/2208","display_name":"Electrical and Electronic Engineering"},"field":{"id":"https://openalex.org/fields/22","display_name":"Engineering"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}},{"id":"https://openalex.org/T12238","display_name":"Green IT and Sustainability","score":0.989300012588501,"subfield":{"id":"https://openalex.org/subfields/2208","display_name":"Electrical and Electronic Engineering"},"field":{"id":"https://openalex.org/fields/22","display_name":"Engineering"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}},{"id":"https://openalex.org/T12146","display_name":"Power Line Communications and Noise","score":0.9839000105857849,"subfield":{"id":"https://openalex.org/subfields/2208","display_name":"Electrical and Electronic Engineering"},"field":{"id":"https://openalex.org/fields/22","display_name":"Engineering"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}}],"keywords":[{"id":"https://openalex.org/keywords/metering-mode","display_name":"Metering mode","score":0.7971850037574768},{"id":"https://openalex.org/keywords/computer-science","display_name":"Computer science","score":0.7141386270523071},{"id":"https://openalex.org/keywords/smart-meter","display_name":"Smart meter","score":0.6503458023071289},{"id":"https://openalex.org/keywords/context","display_name":"Context (archaeology)","score":0.6040613651275635},{"id":"https://openalex.org/keywords/embedded-system","display_name":"Embedded system","score":0.5057029724121094},{"id":"https://openalex.org/keywords/internet-of-things","display_name":"Internet of Things","score":0.5054855346679688},{"id":"https://openalex.org/keywords/efficient-energy-use","display_name":"Efficient energy use","score":0.48962122201919556},{"id":"https://openalex.org/keywords/software","display_name":"Software","score":0.48749256134033203},{"id":"https://openalex.org/keywords/real-time-computing","display_name":"Real-time computing","score":0.48591986298561096},{"id":"https://openalex.org/keywords/smart-grid","display_name":"Smart grid","score":0.4850577414035797},{"id":"https://openalex.org/keywords/electricity-meter","display_name":"Electricity meter","score":0.459085613489151},{"id":"https://openalex.org/keywords/power","display_name":"Power (physics)","score":0.3038720190525055},{"id":"https://openalex.org/keywords/engineering","display_name":"Engineering","score":0.21157729625701904},{"id":"https://openalex.org/keywords/operating-system","display_name":"Operating system","score":0.10864359140396118},{"id":"https://openalex.org/keywords/electrical-engineering","display_name":"Electrical engineering","score":0.09409347176551819}],"concepts":[{"id":"https://openalex.org/C30905978","wikidata":"https://www.wikidata.org/wiki/Q815598","display_name":"Metering mode","level":2,"score":0.7971850037574768},{"id":"https://openalex.org/C41008148","wikidata":"https://www.wikidata.org/wiki/Q21198","display_name":"Computer science","level":0,"score":0.7141386270523071},{"id":"https://openalex.org/C2779510800","wikidata":"https://www.wikidata.org/wiki/Q1630602","display_name":"Smart meter","level":3,"score":0.6503458023071289},{"id":"https://openalex.org/C2779343474","wikidata":"https://www.wikidata.org/wiki/Q3109175","display_name":"Context (archaeology)","level":2,"score":0.6040613651275635},{"id":"https://openalex.org/C149635348","wikidata":"https://www.wikidata.org/wiki/Q193040","display_name":"Embedded system","level":1,"score":0.5057029724121094},{"id":"https://openalex.org/C81860439","wikidata":"https://www.wikidata.org/wiki/Q251212","display_name":"Internet of Things","level":2,"score":0.5054855346679688},{"id":"https://openalex.org/C2742236","wikidata":"https://www.wikidata.org/wiki/Q924713","display_name":"Efficient energy use","level":2,"score":0.48962122201919556},{"id":"https://openalex.org/C2777904410","wikidata":"https://www.wikidata.org/wiki/Q7397","display_name":"Software","level":2,"score":0.48749256134033203},{"id":"https://openalex.org/C79403827","wikidata":"https://www.wikidata.org/wiki/Q3988","display_name":"Real-time computing","level":1,"score":0.48591986298561096},{"id":"https://openalex.org/C10558101","wikidata":"https://www.wikidata.org/wiki/Q689855","display_name":"Smart grid","level":2,"score":0.4850577414035797},{"id":"https://openalex.org/C67172668","wikidata":"https://www.wikidata.org/wiki/Q622756","display_name":"Electricity meter","level":3,"score":0.459085613489151},{"id":"https://openalex.org/C163258240","wikidata":"https://www.wikidata.org/wiki/Q25342","display_name":"Power (physics)","level":2,"score":0.3038720190525055},{"id":"https://openalex.org/C127413603","wikidata":"https://www.wikidata.org/wiki/Q11023","display_name":"Engineering","level":0,"score":0.21157729625701904},{"id":"https://openalex.org/C111919701","wikidata":"https://www.wikidata.org/wiki/Q9135","display_name":"Operating system","level":1,"score":0.10864359140396118},{"id":"https://openalex.org/C119599485","wikidata":"https://www.wikidata.org/wiki/Q43035","display_name":"Electrical engineering","level":1,"score":0.09409347176551819},{"id":"https://openalex.org/C151730666","wikidata":"https://www.wikidata.org/wiki/Q7205","display_name":"Paleontology","level":1,"score":0.0},{"id":"https://openalex.org/C78519656","wikidata":"https://www.wikidata.org/wiki/Q101333","display_name":"Mechanical engineering","level":1,"score":0.0},{"id":"https://openalex.org/C121332964","wikidata":"https://www.wikidata.org/wiki/Q413","display_name":"Physics","level":0,"score":0.0},{"id":"https://openalex.org/C86803240","wikidata":"https://www.wikidata.org/wiki/Q420","display_name":"Biology","level":0,"score":0.0},{"id":"https://openalex.org/C62520636","wikidata":"https://www.wikidata.org/wiki/Q944","display_name":"Quantum mechanics","level":1,"score":0.0}],"mesh":[],"locations_count":3,"locations":[{"id":"doi:10.1109/isie.2017.8001444","is_oa":false,"landing_page_url":"https://doi.org/10.1109/isie.2017.8001444","pdf_url":null,"source":null,"license":null,"license_id":null,"version":"publishedVersion","is_accepted":true,"is_published":true,"raw_source_name":"2017 IEEE 26th International Symposium on Industrial Electronics (ISIE)","raw_type":"proceedings-article"},{"id":"pmh:oai:cris.unibo.it:11585/1043459","is_oa":false,"landing_page_url":"https://hdl.handle.net/11585/1043459","pdf_url":null,"source":{"id":"https://openalex.org/S4306402579","display_name":"Archivio istituzionale della ricerca (Alma Mater Studiorum Universit\u00e0 di Bologna)","issn_l":null,"issn":null,"is_oa":false,"is_in_doaj":false,"is_core":false,"host_organization":"https://openalex.org/I4210117483","host_organization_name":"Istituto di Ematologia di Bologna","host_organization_lineage":["https://openalex.org/I4210117483"],"host_organization_lineage_names":[],"type":"repository"},"license":null,"license_id":null,"version":"submittedVersion","is_accepted":false,"is_published":false,"raw_source_name":null,"raw_type":"info:eu-repo/semantics/conferenceObject"},{"id":"pmh:oai:iris.unitn.it:11572/184936","is_oa":false,"landing_page_url":"http://hdl.handle.net/11572/184936","pdf_url":null,"source":{"id":"https://openalex.org/S4306401913","display_name":"Institutional Research Information System (Universit\u00e0 degli Studi di Trento)","issn_l":null,"issn":null,"is_oa":false,"is_in_doaj":false,"is_core":false,"host_organization":"https://openalex.org/I193223587","host_organization_name":"University of Trento","host_organization_lineage":["https://openalex.org/I193223587"],"host_organization_lineage_names":[],"type":"repository"},"license":null,"license_id":null,"version":"submittedVersion","is_accepted":false,"is_published":false,"raw_source_name":null,"raw_type":"info:eu-repo/semantics/conferenceObject"}],"best_oa_location":null,"sustainable_development_goals":[{"id":"https://metadata.un.org/sdg/7","score":0.8500000238418579,"display_name":"Affordable and clean energy"}],"awards":[],"funders":[{"id":"https://openalex.org/F4320325935","display_name":"Fondazione Cassa Di Risparmio Di Trento E Rovereto","ror":"https://ror.org/02pgnjz11"}],"has_content":{"grobid_xml":false,"pdf":false},"content_urls":null,"referenced_works_count":24,"referenced_works":["https://openalex.org/W1138573735","https://openalex.org/W1479651931","https://openalex.org/W1569264410","https://openalex.org/W1985103893","https://openalex.org/W1988104506","https://openalex.org/W2018168518","https://openalex.org/W2045247177","https://openalex.org/W2053734136","https://openalex.org/W2062707341","https://openalex.org/W2080832204","https://openalex.org/W2123910460","https://openalex.org/W2139270924","https://openalex.org/W2150066276","https://openalex.org/W2152615204","https://openalex.org/W2153639522","https://openalex.org/W2161039500","https://openalex.org/W2255051834","https://openalex.org/W2334762426","https://openalex.org/W2523252861","https://openalex.org/W2921676705","https://openalex.org/W3099873379","https://openalex.org/W4255644811","https://openalex.org/W6627345084","https://openalex.org/W6682535330"],"related_works":["https://openalex.org/W4312869071","https://openalex.org/W2028978355","https://openalex.org/W25930971","https://openalex.org/W1990698919","https://openalex.org/W3018909029","https://openalex.org/W3205631650","https://openalex.org/W2077996342","https://openalex.org/W2775355700","https://openalex.org/W2561882072","https://openalex.org/W2246071452"],"abstract_inverted_index":{"Next":[0],"generation":[1],"Smart":[2],"Cities":[3],"have":[4],"the":[5,9,17,34,58,109],"potential":[6],"to":[7,15,28],"enhance":[8],"citizens":[10],"quality":[11],"of":[12,60,88,111],"life":[13],"and":[14,36,103],"reduce":[16],"overall":[18],"energy":[19,31],"expenditure.":[20],"In":[21,39,64],"particular,":[22],"emerging":[23],"smart":[24,105],"metering":[25,44],"technologies":[26],"promise":[27],"greatly":[29],"increase":[30],"efficiency":[32],"in":[33],"residential":[35],"industrial":[37],"areas.":[38],"this":[40,65],"context,":[41],"new":[42,86],"power":[43,89],"methods":[45],"such":[46],"as":[47],"Non-Intrusive":[48],"Load":[49],"Monitoring":[50],"(NILM)":[51],"can":[52],"provide":[53],"important":[54],"real-time":[55,99],"information":[56],"about":[57],"contribution":[59],"any":[61],"single":[62],"appliance.":[63],"paper,":[66],"we":[67],"present":[68],"a":[69,101],"complete":[70],"hardware-software":[71],"design":[72],"that":[73],"concentrates":[74],"locally":[75],"an":[76],"efficient":[77],"event-based":[78],"supervised":[79],"NILM":[80],"algorithm":[81],"for":[82,108],"load":[83],"disaggregation.":[84],"This":[85],"kind":[87],"analysis,":[90],"which":[91],"usually":[92],"requires":[93],"high":[94],"computing":[95],"capability,":[96],"is":[97],"executed":[98],"on":[100],"low-cost":[102],"easy-to-install":[104],"meter":[106],"ready":[107],"Internet":[110],"Things":[112],"(IoT).":[113]},"counts_by_year":[{"year":2025,"cited_by_count":1},{"year":2023,"cited_by_count":1},{"year":2022,"cited_by_count":1},{"year":2021,"cited_by_count":1},{"year":2020,"cited_by_count":3},{"year":2019,"cited_by_count":2},{"year":2018,"cited_by_count":3},{"year":2017,"cited_by_count":2}],"updated_date":"2026-03-20T23:20:44.827607","created_date":"2025-10-10T00:00:00"}
