{"id":"https://openalex.org/W2743642815","doi":"https://doi.org/10.1109/isie.2017.8001358","title":"Six-phase active PWM rectifier with stationary frame reference control","display_name":"Six-phase active PWM rectifier with stationary frame reference control","publication_year":2017,"publication_date":"2017-06-01","ids":{"openalex":"https://openalex.org/W2743642815","doi":"https://doi.org/10.1109/isie.2017.8001358","mag":"2743642815"},"language":"en","primary_location":{"id":"doi:10.1109/isie.2017.8001358","is_oa":false,"landing_page_url":"https://doi.org/10.1109/isie.2017.8001358","pdf_url":null,"source":null,"license":null,"license_id":null,"version":"publishedVersion","is_accepted":true,"is_published":true,"raw_source_name":"2017 IEEE 26th International Symposium on Industrial Electronics (ISIE)","raw_type":"proceedings-article"},"type":"conference-paper","indexed_in":["crossref"],"open_access":{"is_oa":false,"oa_status":"closed","oa_url":null,"any_repository_has_fulltext":false},"authorships":[{"author_position":"first","author":{"id":"https://openalex.org/A5005208101","display_name":"Cesar Augusto Arbugeri","orcid":"https://orcid.org/0000-0003-2797-4019"},"institutions":[],"countries":[],"is_corresponding":false,"raw_author_name":"C. A. Arbugeri","raw_affiliation_strings":["Departament of Electrical and Electronic Engineering, Power Electronics Institute (INEP), Florianopolis, Brazil"],"raw_orcid":null,"affiliations":[{"raw_affiliation_string":"Departament of Electrical and Electronic Engineering, Power Electronics Institute (INEP), Florianopolis, Brazil","institution_ids":[]}]},{"author_position":"middle","author":{"id":"https://openalex.org/A5091602597","display_name":"Telles Brunelli Lazzarin","orcid":"https://orcid.org/0000-0001-8598-8641"},"institutions":[],"countries":[],"is_corresponding":false,"raw_author_name":"T. B. Lazzarin","raw_affiliation_strings":["Departament of Electrical and Electronic Engineering, Power Electronics Institute (INEP), Florianopolis, Brazil"],"raw_orcid":null,"affiliations":[{"raw_affiliation_string":"Departament of Electrical and Electronic Engineering, Power Electronics Institute (INEP), Florianopolis, Brazil","institution_ids":[]}]},{"author_position":"last","author":{"id":"https://openalex.org/A5037873644","display_name":"Samir Ahmad Mussa","orcid":"https://orcid.org/0000-0003-1102-422X"},"institutions":[],"countries":[],"is_corresponding":false,"raw_author_name":"S. A. Mussa","raw_affiliation_strings":["Departament of Electrical and Electronic Engineering, Power Electronics Institute (INEP), Florianopolis, Brazil"],"raw_orcid":null,"affiliations":[{"raw_affiliation_string":"Departament of Electrical and Electronic Engineering, Power Electronics Institute (INEP), Florianopolis, Brazil","institution_ids":[]}]}],"institutions":[],"countries_distinct_count":0,"institutions_distinct_count":0,"corresponding_author_ids":[],"corresponding_institution_ids":[],"apc_list":null,"apc_paid":null,"fwci":0.7584,"has_fulltext":false,"cited_by_count":4,"citation_normalized_percentile":{"value":0.62860422,"is_in_top_1_percent":false,"is_in_top_10_percent":false},"cited_by_percentile_year":{"min":94,"max":96},"biblio":{"volume":"61","issue":null,"first_page":"856","last_page":"860"},"is_retracted":false,"is_paratext":false,"is_xpac":false,"primary_topic":{"id":"https://openalex.org/T10228","display_name":"Multilevel Inverters and Converters","score":1.0,"subfield":{"id":"https://openalex.org/subfields/2208","display_name":"Electrical and Electronic Engineering"},"field":{"id":"https://openalex.org/fields/22","display_name":"Engineering"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}},"topics":[{"id":"https://openalex.org/T10228","display_name":"Multilevel Inverters and Converters","score":1.0,"subfield":{"id":"https://openalex.org/subfields/2208","display_name":"Electrical and Electronic Engineering"},"field":{"id":"https://openalex.org/fields/22","display_name":"Engineering"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}},{"id":"https://openalex.org/T10175","display_name":"Advanced DC-DC Converters","score":0.9994999766349792,"subfield":{"id":"https://openalex.org/subfields/2208","display_name":"Electrical and Electronic Engineering"},"field":{"id":"https://openalex.org/fields/22","display_name":"Engineering"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}},{"id":"https://openalex.org/T10223","display_name":"Microgrid Control and Optimization","score":0.9965999722480774,"subfield":{"id":"https://openalex.org/subfields/2207","display_name":"Control and Systems Engineering"},"field":{"id":"https://openalex.org/fields/22","display_name":"Engineering"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}}],"keywords":[{"id":"https://openalex.org/keywords/rectifier","display_name":"Rectifier (neural networks)","score":0.6571276783943176},{"id":"https://openalex.org/keywords/peak-inverse-voltage","display_name":"Peak inverse voltage","score":0.6407719850540161},{"id":"https://openalex.org/keywords/control-theory","display_name":"Control theory (sociology)","score":0.6233139634132385},{"id":"https://openalex.org/keywords/total-harmonic-distortion","display_name":"Total harmonic distortion","score":0.6226704120635986},{"id":"https://openalex.org/keywords/three-phase","display_name":"Three-phase","score":0.6148297190666199},{"id":"https://openalex.org/keywords/precision-rectifier","display_name":"Precision rectifier","score":0.6031639575958252},{"id":"https://openalex.org/keywords/topology","display_name":"Topology (electrical circuits)","score":0.5391535758972168},{"id":"https://openalex.org/keywords/reference-frame","display_name":"Reference frame","score":0.5382534861564636},{"id":"https://openalex.org/keywords/pulse-width-modulation","display_name":"Pulse-width modulation","score":0.5330670475959778},{"id":"https://openalex.org/keywords/computer-science","display_name":"Computer science","score":0.5168400406837463},{"id":"https://openalex.org/keywords/stationary-reference-frame","display_name":"Stationary Reference Frame","score":0.5114408731460571},{"id":"https://openalex.org/keywords/pwm-rectifier","display_name":"PWM rectifier","score":0.49628740549087524},{"id":"https://openalex.org/keywords/voltage","display_name":"Voltage","score":0.4936467409133911},{"id":"https://openalex.org/keywords/power-factor","display_name":"Power factor","score":0.47995808720588684},{"id":"https://openalex.org/keywords/voltage-reference","display_name":"Voltage reference","score":0.4405766725540161},{"id":"https://openalex.org/keywords/adjustable-speed-drive","display_name":"Adjustable-speed drive","score":0.4207446277141571},{"id":"https://openalex.org/keywords/generator","display_name":"Generator (circuit theory)","score":0.4134470820426941},{"id":"https://openalex.org/keywords/frame","display_name":"Frame (networking)","score":0.37704217433929443},{"id":"https://openalex.org/keywords/power","display_name":"Power (physics)","score":0.32170844078063965},{"id":"https://openalex.org/keywords/engineering","display_name":"Engineering","score":0.24525126814842224},{"id":"https://openalex.org/keywords/physics","display_name":"Physics","score":0.21315157413482666},{"id":"https://openalex.org/keywords/voltage-optimisation","display_name":"Voltage optimisation","score":0.19350358843803406},{"id":"https://openalex.org/keywords/electrical-engineering","display_name":"Electrical engineering","score":0.1777530014514923},{"id":"https://openalex.org/keywords/control","display_name":"Control (management)","score":0.10982802510261536},{"id":"https://openalex.org/keywords/telecommunications","display_name":"Telecommunications","score":0.06286674737930298},{"id":"https://openalex.org/keywords/induction-motor","display_name":"Induction motor","score":0.05944505333900452}],"concepts":[{"id":"https://openalex.org/C50100734","wikidata":"https://www.wikidata.org/wiki/Q7303176","display_name":"Rectifier (neural networks)","level":5,"score":0.6571276783943176},{"id":"https://openalex.org/C26242798","wikidata":"https://www.wikidata.org/wiki/Q7157860","display_name":"Peak inverse voltage","level":5,"score":0.6407719850540161},{"id":"https://openalex.org/C47446073","wikidata":"https://www.wikidata.org/wiki/Q5165890","display_name":"Control theory (sociology)","level":3,"score":0.6233139634132385},{"id":"https://openalex.org/C42156128","wikidata":"https://www.wikidata.org/wiki/Q162641","display_name":"Total harmonic distortion","level":3,"score":0.6226704120635986},{"id":"https://openalex.org/C173871940","wikidata":"https://www.wikidata.org/wiki/Q471846","display_name":"Three-phase","level":3,"score":0.6148297190666199},{"id":"https://openalex.org/C46871319","wikidata":"https://www.wikidata.org/wiki/Q943122","display_name":"Precision rectifier","level":4,"score":0.6031639575958252},{"id":"https://openalex.org/C184720557","wikidata":"https://www.wikidata.org/wiki/Q7825049","display_name":"Topology (electrical circuits)","level":2,"score":0.5391535758972168},{"id":"https://openalex.org/C172849965","wikidata":"https://www.wikidata.org/wiki/Q3148875","display_name":"Reference frame","level":3,"score":0.5382534861564636},{"id":"https://openalex.org/C92746544","wikidata":"https://www.wikidata.org/wiki/Q585184","display_name":"Pulse-width modulation","level":3,"score":0.5330670475959778},{"id":"https://openalex.org/C41008148","wikidata":"https://www.wikidata.org/wiki/Q21198","display_name":"Computer science","level":0,"score":0.5168400406837463},{"id":"https://openalex.org/C2778690891","wikidata":"https://www.wikidata.org/wiki/Q17098955","display_name":"Stationary Reference Frame","level":4,"score":0.5114408731460571},{"id":"https://openalex.org/C2778679047","wikidata":"https://www.wikidata.org/wiki/Q7121175","display_name":"PWM rectifier","level":4,"score":0.49628740549087524},{"id":"https://openalex.org/C165801399","wikidata":"https://www.wikidata.org/wiki/Q25428","display_name":"Voltage","level":2,"score":0.4936467409133911},{"id":"https://openalex.org/C64424096","wikidata":"https://www.wikidata.org/wiki/Q750454","display_name":"Power factor","level":3,"score":0.47995808720588684},{"id":"https://openalex.org/C44351266","wikidata":"https://www.wikidata.org/wiki/Q1465532","display_name":"Voltage reference","level":3,"score":0.4405766725540161},{"id":"https://openalex.org/C2778344601","wikidata":"https://www.wikidata.org/wiki/Q4304910","display_name":"Adjustable-speed drive","level":4,"score":0.4207446277141571},{"id":"https://openalex.org/C2780992000","wikidata":"https://www.wikidata.org/wiki/Q17016113","display_name":"Generator (circuit theory)","level":3,"score":0.4134470820426941},{"id":"https://openalex.org/C126042441","wikidata":"https://www.wikidata.org/wiki/Q1324888","display_name":"Frame (networking)","level":2,"score":0.37704217433929443},{"id":"https://openalex.org/C163258240","wikidata":"https://www.wikidata.org/wiki/Q25342","display_name":"Power (physics)","level":2,"score":0.32170844078063965},{"id":"https://openalex.org/C127413603","wikidata":"https://www.wikidata.org/wiki/Q11023","display_name":"Engineering","level":0,"score":0.24525126814842224},{"id":"https://openalex.org/C121332964","wikidata":"https://www.wikidata.org/wiki/Q413","display_name":"Physics","level":0,"score":0.21315157413482666},{"id":"https://openalex.org/C46529443","wikidata":"https://www.wikidata.org/wiki/Q7940750","display_name":"Voltage optimisation","level":4,"score":0.19350358843803406},{"id":"https://openalex.org/C119599485","wikidata":"https://www.wikidata.org/wiki/Q43035","display_name":"Electrical engineering","level":1,"score":0.1777530014514923},{"id":"https://openalex.org/C2775924081","wikidata":"https://www.wikidata.org/wiki/Q55608371","display_name":"Control (management)","level":2,"score":0.10982802510261536},{"id":"https://openalex.org/C76155785","wikidata":"https://www.wikidata.org/wiki/Q418","display_name":"Telecommunications","level":1,"score":0.06286674737930298},{"id":"https://openalex.org/C80962145","wikidata":"https://www.wikidata.org/wiki/Q207450","display_name":"Induction motor","level":3,"score":0.05944505333900452},{"id":"https://openalex.org/C154945302","wikidata":"https://www.wikidata.org/wiki/Q11660","display_name":"Artificial intelligence","level":1,"score":0.0},{"id":"https://openalex.org/C86582703","wikidata":"https://www.wikidata.org/wiki/Q7617824","display_name":"Stochastic neural network","level":4,"score":0.0},{"id":"https://openalex.org/C147168706","wikidata":"https://www.wikidata.org/wiki/Q1457734","display_name":"Recurrent neural network","level":3,"score":0.0},{"id":"https://openalex.org/C50644808","wikidata":"https://www.wikidata.org/wiki/Q192776","display_name":"Artificial neural network","level":2,"score":0.0},{"id":"https://openalex.org/C62520636","wikidata":"https://www.wikidata.org/wiki/Q944","display_name":"Quantum mechanics","level":1,"score":0.0},{"id":"https://openalex.org/C119857082","wikidata":"https://www.wikidata.org/wiki/Q2539","display_name":"Machine learning","level":1,"score":0.0}],"mesh":[],"locations_count":1,"locations":[{"id":"doi:10.1109/isie.2017.8001358","is_oa":false,"landing_page_url":"https://doi.org/10.1109/isie.2017.8001358","pdf_url":null,"source":null,"license":null,"license_id":null,"version":"publishedVersion","is_accepted":true,"is_published":true,"raw_source_name":"2017 IEEE 26th International Symposium on Industrial Electronics (ISIE)","raw_type":"proceedings-article"}],"best_oa_location":null,"sustainable_development_goals":[{"id":"https://metadata.un.org/sdg/7","score":0.9100000262260437,"display_name":"Affordable and clean energy"}],"awards":[],"funders":[],"has_content":{"pdf":false,"grobid_xml":false},"content_urls":null,"referenced_works_count":22,"referenced_works":["https://openalex.org/W1965517175","https://openalex.org/W1990225510","https://openalex.org/W2021630260","https://openalex.org/W2041237441","https://openalex.org/W2041937566","https://openalex.org/W2044323057","https://openalex.org/W2060596970","https://openalex.org/W2064330660","https://openalex.org/W2067437048","https://openalex.org/W2121622100","https://openalex.org/W2130338241","https://openalex.org/W2133591346","https://openalex.org/W2165978891","https://openalex.org/W2167426294","https://openalex.org/W2169632892","https://openalex.org/W2171517545","https://openalex.org/W2172178055","https://openalex.org/W2537473867","https://openalex.org/W2539776432","https://openalex.org/W2556705919","https://openalex.org/W6679204135","https://openalex.org/W6685309286"],"related_works":["https://openalex.org/W2007229856","https://openalex.org/W2349275432","https://openalex.org/W2367281552","https://openalex.org/W2037186865","https://openalex.org/W3120588975","https://openalex.org/W2365953123","https://openalex.org/W2150660880","https://openalex.org/W2382510447","https://openalex.org/W2350416259","https://openalex.org/W2352483037"],"abstract_inverted_index":{"Poly-phase":[0],"systems":[1],"have":[2],"been":[3],"used":[4],"for":[5,88,97,135],"many":[6],"years":[7],"in":[8,12,69,108,119],"machines":[9],"and":[10,33,72,112,128,145,168],"recently":[11],"wind":[13],"power":[14,171],"generations.":[15],"They":[16],"usually":[17],"are":[18],"built":[19],"by":[20,26,133],"a":[21,42,83,89,114,157],"dual":[22,90],"three-phase":[23,91],"system,":[24],"shifted":[25],"30":[27],"electrical":[28],"degrees":[29],"from":[30],"each":[31],"other":[32],"with":[34,164],"no":[35],"neutral":[36],"connection.":[37],"Typically,":[38],"this":[39,80,120],"system":[40,99],"employs":[41],"twelve-pulse":[43],"diode":[44],"rectifier":[45,60,86],"to":[46,49,102],"converter":[47,105],"ac":[48],"dc":[50],"voltages.":[51],"However,":[52],"it":[53,64],"may":[54],"be":[55],"improved":[56],"if":[57],"an":[58,161],"active":[59,85],"is":[61,100,117],"used,":[62],"because":[63],"can":[65],"provide":[66],"lower":[67],"distortion":[68,167],"generator":[70],"currents":[71],"regulated":[73,158],"output":[74,150,159],"voltage.":[75,151],"Taking":[76],"that":[77],"into":[78],"account,":[79],"paper":[81],"proposes":[82],"six-phase":[84,98],"topology":[87],"system.":[92],"A":[93],"stationary":[94],"frame":[95,121],"reference":[96],"applied":[101],"obtain":[103],"the":[104,109,149],"dynamic":[106,126],"model":[107,127],"\u03b1\u03b2":[110],"coordinates":[111],"thus":[113,169],"control":[115,129],"strategy":[116,130],"proposed":[118,124],"reference.":[122],"The":[123,152],"topology,":[125],"were":[131,154],"verified":[132],"simulation":[134],"following":[136],"specification:":[137],"12":[138],"kW,":[139],"220":[140],"V":[141,147],"at":[142,148],"input":[143,162],"voltage":[144],"800":[146],"results":[153],"appropriated,":[155],"providing":[156],"voltage,":[160],"current":[163],"reduced":[165],"harmonic":[166],"high":[170],"factor.":[172]},"counts_by_year":[{"year":2023,"cited_by_count":2},{"year":2019,"cited_by_count":2}],"updated_date":"2026-07-29T14:22:42.915294","created_date":"2025-10-10T00:00:00"}
