{"id":"https://openalex.org/W2139010292","doi":"https://doi.org/10.1109/isie.2014.6864629","title":"A brushless generation system for microgrid operation utilizing dual stator induction generator","display_name":"A brushless generation system for microgrid operation utilizing dual stator induction generator","publication_year":2014,"publication_date":"2014-06-01","ids":{"openalex":"https://openalex.org/W2139010292","doi":"https://doi.org/10.1109/isie.2014.6864629","mag":"2139010292"},"language":"en","primary_location":{"id":"doi:10.1109/isie.2014.6864629","is_oa":false,"landing_page_url":"https://doi.org/10.1109/isie.2014.6864629","pdf_url":null,"source":null,"license":null,"license_id":null,"version":"publishedVersion","is_accepted":true,"is_published":true,"raw_source_name":"2014 IEEE 23rd International Symposium on Industrial Electronics (ISIE)","raw_type":"proceedings-article"},"type":"article","indexed_in":["crossref"],"open_access":{"is_oa":false,"oa_status":"closed","oa_url":null,"any_repository_has_fulltext":false},"authorships":[{"author_position":"first","author":{"id":"https://openalex.org/A5084453047","display_name":"Saptarshi Basak","orcid":"https://orcid.org/0000-0002-2125-0389"},"institutions":[{"id":"https://openalex.org/I145894827","display_name":"Indian Institute of Technology Kharagpur","ror":"https://ror.org/03w5sq511","country_code":"IN","type":"education","lineage":["https://openalex.org/I145894827"]}],"countries":["IN"],"is_corresponding":true,"raw_author_name":"Saptarshi Basak","raw_affiliation_strings":["Department of Electrical Engineering, Indian Institute of Technology, Kharagpur, India","Dept. of Electr. Eng., Indian Inst. of Technol. Kharagpur, Kharagpur, India"],"affiliations":[{"raw_affiliation_string":"Department of Electrical Engineering, Indian Institute of Technology, Kharagpur, India","institution_ids":["https://openalex.org/I145894827"]},{"raw_affiliation_string":"Dept. of Electr. Eng., Indian Inst. of Technol. Kharagpur, Kharagpur, India","institution_ids":["https://openalex.org/I145894827"]}]},{"author_position":"last","author":{"id":"https://openalex.org/A5022432777","display_name":"Chandan Chakraborty","orcid":"https://orcid.org/0000-0001-8251-3552"},"institutions":[{"id":"https://openalex.org/I145894827","display_name":"Indian Institute of Technology Kharagpur","ror":"https://ror.org/03w5sq511","country_code":"IN","type":"education","lineage":["https://openalex.org/I145894827"]}],"countries":["IN"],"is_corresponding":false,"raw_author_name":"Chandan Chakraborty","raw_affiliation_strings":["Department of Electrical Engineering, Indian Institute of Technology, Kharagpur, India","Dept. of Electr. Eng., Indian Inst. of Technol. Kharagpur, Kharagpur, India"],"affiliations":[{"raw_affiliation_string":"Department of Electrical Engineering, Indian Institute of Technology, Kharagpur, India","institution_ids":["https://openalex.org/I145894827"]},{"raw_affiliation_string":"Dept. of Electr. Eng., Indian Inst. of Technol. Kharagpur, Kharagpur, India","institution_ids":["https://openalex.org/I145894827"]}]}],"institutions":[],"countries_distinct_count":1,"institutions_distinct_count":2,"corresponding_author_ids":["https://openalex.org/A5084453047"],"corresponding_institution_ids":["https://openalex.org/I145894827"],"apc_list":null,"apc_paid":null,"fwci":0.2093,"has_fulltext":false,"cited_by_count":3,"citation_normalized_percentile":{"value":0.61489382,"is_in_top_1_percent":false,"is_in_top_10_percent":false},"cited_by_percentile_year":{"min":89,"max":94},"biblio":{"volume":null,"issue":null,"first_page":"302","last_page":"307"},"is_retracted":false,"is_paratext":false,"is_xpac":false,"primary_topic":{"id":"https://openalex.org/T10740","display_name":"Wind Turbine Control Systems","score":0.9994000196456909,"subfield":{"id":"https://openalex.org/subfields/2208","display_name":"Electrical and Electronic Engineering"},"field":{"id":"https://openalex.org/fields/22","display_name":"Engineering"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}},"topics":[{"id":"https://openalex.org/T10740","display_name":"Wind Turbine Control Systems","score":0.9994000196456909,"subfield":{"id":"https://openalex.org/subfields/2208","display_name":"Electrical and Electronic Engineering"},"field":{"id":"https://openalex.org/fields/22","display_name":"Engineering"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}},{"id":"https://openalex.org/T10223","display_name":"Microgrid Control and Optimization","score":0.9993000030517578,"subfield":{"id":"https://openalex.org/subfields/2207","display_name":"Control and Systems Engineering"},"field":{"id":"https://openalex.org/fields/22","display_name":"Engineering"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}},{"id":"https://openalex.org/T13183","display_name":"Islanding Detection in Power Systems","score":0.9962999820709229,"subfield":{"id":"https://openalex.org/subfields/2208","display_name":"Electrical and Electronic Engineering"},"field":{"id":"https://openalex.org/fields/22","display_name":"Engineering"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}}],"keywords":[{"id":"https://openalex.org/keywords/stator","display_name":"Stator","score":0.7141351699829102},{"id":"https://openalex.org/keywords/induction-generator","display_name":"Induction generator","score":0.6900471448898315},{"id":"https://openalex.org/keywords/inverter","display_name":"Inverter","score":0.603948712348938},{"id":"https://openalex.org/keywords/microgrid","display_name":"Microgrid","score":0.5914962887763977},{"id":"https://openalex.org/keywords/rotor","display_name":"Rotor (electric)","score":0.51735919713974},{"id":"https://openalex.org/keywords/generator","display_name":"Generator (circuit theory)","score":0.4937473237514496},{"id":"https://openalex.org/keywords/computer-science","display_name":"Computer science","score":0.48471498489379883},{"id":"https://openalex.org/keywords/rectifier","display_name":"Rectifier (neural networks)","score":0.4783291816711426},{"id":"https://openalex.org/keywords/grid","display_name":"Grid","score":0.4481649398803711},{"id":"https://openalex.org/keywords/shunt-generator","display_name":"Shunt generator","score":0.443392813205719},{"id":"https://openalex.org/keywords/voltage","display_name":"Voltage","score":0.440392404794693},{"id":"https://openalex.org/keywords/control-theory","display_name":"Control theory (sociology)","score":0.4352642595767975},{"id":"https://openalex.org/keywords/electrical-engineering","display_name":"Electrical engineering","score":0.43214157223701477},{"id":"https://openalex.org/keywords/electricity-generation","display_name":"Electricity generation","score":0.4210677146911621},{"id":"https://openalex.org/keywords/permanent-magnet-synchronous-generator","display_name":"Permanent magnet synchronous generator","score":0.37340956926345825},{"id":"https://openalex.org/keywords/power","display_name":"Power (physics)","score":0.3540465235710144},{"id":"https://openalex.org/keywords/engineering","display_name":"Engineering","score":0.33899182081222534},{"id":"https://openalex.org/keywords/physics","display_name":"Physics","score":0.13394403457641602},{"id":"https://openalex.org/keywords/control","display_name":"Control (management)","score":0.0995190441608429}],"concepts":[{"id":"https://openalex.org/C2776529397","wikidata":"https://www.wikidata.org/wiki/Q190312","display_name":"Stator","level":2,"score":0.7141351699829102},{"id":"https://openalex.org/C98716924","wikidata":"https://www.wikidata.org/wiki/Q752750","display_name":"Induction generator","level":3,"score":0.6900471448898315},{"id":"https://openalex.org/C11190779","wikidata":"https://www.wikidata.org/wiki/Q664575","display_name":"Inverter","level":3,"score":0.603948712348938},{"id":"https://openalex.org/C2776784348","wikidata":"https://www.wikidata.org/wiki/Q5762595","display_name":"Microgrid","level":3,"score":0.5914962887763977},{"id":"https://openalex.org/C17281054","wikidata":"https://www.wikidata.org/wiki/Q193466","display_name":"Rotor (electric)","level":2,"score":0.51735919713974},{"id":"https://openalex.org/C2780992000","wikidata":"https://www.wikidata.org/wiki/Q17016113","display_name":"Generator (circuit theory)","level":3,"score":0.4937473237514496},{"id":"https://openalex.org/C41008148","wikidata":"https://www.wikidata.org/wiki/Q21198","display_name":"Computer science","level":0,"score":0.48471498489379883},{"id":"https://openalex.org/C50100734","wikidata":"https://www.wikidata.org/wiki/Q7303176","display_name":"Rectifier (neural networks)","level":5,"score":0.4783291816711426},{"id":"https://openalex.org/C187691185","wikidata":"https://www.wikidata.org/wiki/Q2020720","display_name":"Grid","level":2,"score":0.4481649398803711},{"id":"https://openalex.org/C68121349","wikidata":"https://www.wikidata.org/wiki/Q7505144","display_name":"Shunt generator","level":4,"score":0.443392813205719},{"id":"https://openalex.org/C165801399","wikidata":"https://www.wikidata.org/wiki/Q25428","display_name":"Voltage","level":2,"score":0.440392404794693},{"id":"https://openalex.org/C47446073","wikidata":"https://www.wikidata.org/wiki/Q5165890","display_name":"Control theory (sociology)","level":3,"score":0.4352642595767975},{"id":"https://openalex.org/C119599485","wikidata":"https://www.wikidata.org/wiki/Q43035","display_name":"Electrical engineering","level":1,"score":0.43214157223701477},{"id":"https://openalex.org/C423512","wikidata":"https://www.wikidata.org/wiki/Q383973","display_name":"Electricity generation","level":3,"score":0.4210677146911621},{"id":"https://openalex.org/C201320609","wikidata":"https://www.wikidata.org/wiki/Q3274420","display_name":"Permanent magnet synchronous generator","level":3,"score":0.37340956926345825},{"id":"https://openalex.org/C163258240","wikidata":"https://www.wikidata.org/wiki/Q25342","display_name":"Power (physics)","level":2,"score":0.3540465235710144},{"id":"https://openalex.org/C127413603","wikidata":"https://www.wikidata.org/wiki/Q11023","display_name":"Engineering","level":0,"score":0.33899182081222534},{"id":"https://openalex.org/C121332964","wikidata":"https://www.wikidata.org/wiki/Q413","display_name":"Physics","level":0,"score":0.13394403457641602},{"id":"https://openalex.org/C2775924081","wikidata":"https://www.wikidata.org/wiki/Q55608371","display_name":"Control (management)","level":2,"score":0.0995190441608429},{"id":"https://openalex.org/C147168706","wikidata":"https://www.wikidata.org/wiki/Q1457734","display_name":"Recurrent neural network","level":3,"score":0.0},{"id":"https://openalex.org/C2524010","wikidata":"https://www.wikidata.org/wiki/Q8087","display_name":"Geometry","level":1,"score":0.0},{"id":"https://openalex.org/C119857082","wikidata":"https://www.wikidata.org/wiki/Q2539","display_name":"Machine learning","level":1,"score":0.0},{"id":"https://openalex.org/C33923547","wikidata":"https://www.wikidata.org/wiki/Q395","display_name":"Mathematics","level":0,"score":0.0},{"id":"https://openalex.org/C62520636","wikidata":"https://www.wikidata.org/wiki/Q944","display_name":"Quantum mechanics","level":1,"score":0.0},{"id":"https://openalex.org/C154945302","wikidata":"https://www.wikidata.org/wiki/Q11660","display_name":"Artificial intelligence","level":1,"score":0.0},{"id":"https://openalex.org/C86582703","wikidata":"https://www.wikidata.org/wiki/Q7617824","display_name":"Stochastic neural network","level":4,"score":0.0},{"id":"https://openalex.org/C50644808","wikidata":"https://www.wikidata.org/wiki/Q192776","display_name":"Artificial neural network","level":2,"score":0.0}],"mesh":[],"locations_count":1,"locations":[{"id":"doi:10.1109/isie.2014.6864629","is_oa":false,"landing_page_url":"https://doi.org/10.1109/isie.2014.6864629","pdf_url":null,"source":null,"license":null,"license_id":null,"version":"publishedVersion","is_accepted":true,"is_published":true,"raw_source_name":"2014 IEEE 23rd International Symposium on Industrial Electronics (ISIE)","raw_type":"proceedings-article"}],"best_oa_location":null,"sustainable_development_goals":[{"display_name":"Affordable and clean energy","score":0.8899999856948853,"id":"https://metadata.un.org/sdg/7"}],"awards":[],"funders":[],"has_content":{"grobid_xml":false,"pdf":false},"content_urls":null,"referenced_works_count":14,"referenced_works":["https://openalex.org/W1598168251","https://openalex.org/W2012923650","https://openalex.org/W2018359526","https://openalex.org/W2022286342","https://openalex.org/W2048457870","https://openalex.org/W2123896795","https://openalex.org/W2125333996","https://openalex.org/W2131057580","https://openalex.org/W2139830682","https://openalex.org/W2144148488","https://openalex.org/W2152092043","https://openalex.org/W2160119641","https://openalex.org/W2163123616","https://openalex.org/W2169567050"],"related_works":["https://openalex.org/W2527000641","https://openalex.org/W2069414036","https://openalex.org/W2386878440","https://openalex.org/W2353952507","https://openalex.org/W2391594540","https://openalex.org/W2352462290","https://openalex.org/W3158196634","https://openalex.org/W4302004468","https://openalex.org/W2377899075","https://openalex.org/W379375666"],"abstract_inverted_index":{"Modern":[0],"micro-grid":[1,123],"needs":[2],"to":[3,57,79,105],"integrate":[4],"all":[5],"possible":[6],"and":[7,23,108],"economically":[8],"attractive":[9],"renewable":[10],"energy":[11],"resources.":[12],"In":[13],"many":[14],"cases":[15],"these":[16],"generations":[17],"are":[18,24],"not":[19],"smooth":[20],"in":[21,26,76],"nature":[22],"situated":[25],"remote":[27],"locations":[28],"where":[29],"regular":[30],"maintenance":[31],"is":[32,55,67,74],"difficult.":[33],"This":[34],"paper":[35],"proposes":[36],"a":[37,42,77],"brushless":[38],"generation":[39],"system":[40,104],"using":[41],"dual":[43],"stator":[44],"winding":[45,51,66,87],"induction":[46],"generator":[47,73],"(DSWIG).":[48],"The":[49,72],"power":[50],"of":[52,84,102,119],"the":[53,58,64,85,90,94,100,103,113],"DSWIG":[54],"connected":[56],"grid":[59],"by":[60,88],"rectifier-inverter":[61],"system,":[62],"whereas,":[63],"excitation":[65,95],"fed":[68],"from":[69],"an":[70],"inverter.":[71],"controlled":[75],"way":[78],"enable":[80],"terminal":[81],"voltage":[82,107],"regulation":[83],"main":[86],"controlling":[89],"rotor":[91],"flux":[92],"through":[93],"winding.":[96],"Preliminary":[97],"results":[98,116],"show":[99,117],"capability":[101],"regulate":[106],"maintain":[109],"constant":[110],"frequency":[111],"at":[112],"micro-grid.":[114],"Simulations":[115],"usefulness":[118],"such":[120],"systems":[121],"for":[122],"operation.":[124]},"counts_by_year":[{"year":2020,"cited_by_count":1},{"year":2018,"cited_by_count":1},{"year":2015,"cited_by_count":1}],"updated_date":"2025-11-06T03:46:38.306776","created_date":"2025-10-10T00:00:00"}
