{"id":"https://openalex.org/W2077645817","doi":"https://doi.org/10.1109/isie.2013.6563803","title":"Distributed reactive power control methods to avoid voltage rise in grid-connected photovoltaic power generation systems","display_name":"Distributed reactive power control methods to avoid voltage rise in grid-connected photovoltaic power generation systems","publication_year":2013,"publication_date":"2013-05-01","ids":{"openalex":"https://openalex.org/W2077645817","doi":"https://doi.org/10.1109/isie.2013.6563803","mag":"2077645817"},"language":"en","primary_location":{"id":"doi:10.1109/isie.2013.6563803","is_oa":false,"landing_page_url":"https://doi.org/10.1109/isie.2013.6563803","pdf_url":null,"source":null,"license":null,"license_id":null,"version":"publishedVersion","is_accepted":true,"is_published":true,"raw_source_name":"2013 IEEE International Symposium on Industrial Electronics","raw_type":"proceedings-article"},"type":"article","indexed_in":["crossref"],"open_access":{"is_oa":true,"oa_status":"green","oa_url":"https://hdl.handle.net/2117/20254","any_repository_has_fulltext":true},"authorships":[{"author_position":"first","author":{"id":"https://openalex.org/A5035831255","display_name":"Pau Mart\u00ed","orcid":"https://orcid.org/0000-0002-5189-0782"},"institutions":[{"id":"https://openalex.org/I9617848","display_name":"Universitat Polit\u00e8cnica de Catalunya","ror":"https://ror.org/03mb6wj31","country_code":"ES","type":"education","lineage":["https://openalex.org/I9617848"]}],"countries":["ES"],"is_corresponding":true,"raw_author_name":"Pau Marti","raw_affiliation_strings":["Automatic Control Department, Technical University of Catalonia, Barcelona, Spain","Automatic Control Department, Technical University of Catalonia, Pau Gargallo 5, 08028 Barcelona, Spain#TAB#"],"affiliations":[{"raw_affiliation_string":"Automatic Control Department, Technical University of Catalonia, Barcelona, Spain","institution_ids":["https://openalex.org/I9617848"]},{"raw_affiliation_string":"Automatic Control Department, Technical University of Catalonia, Pau Gargallo 5, 08028 Barcelona, Spain#TAB#","institution_ids":["https://openalex.org/I9617848"]}]},{"author_position":"middle","author":{"id":"https://openalex.org/A5044922710","display_name":"Manel Velasco","orcid":"https://orcid.org/0000-0002-0764-3063"},"institutions":[{"id":"https://openalex.org/I9617848","display_name":"Universitat Polit\u00e8cnica de Catalunya","ror":"https://ror.org/03mb6wj31","country_code":"ES","type":"education","lineage":["https://openalex.org/I9617848"]}],"countries":["ES"],"is_corresponding":false,"raw_author_name":"Manel Velasco","raw_affiliation_strings":["Automatic Control Department, Technical University of Catalonia, Barcelona, Spain","Automatic Control Department, Technical University of Catalonia, Pau Gargallo 5, 08028 Barcelona, Spain#TAB#"],"affiliations":[{"raw_affiliation_string":"Automatic Control Department, Technical University of Catalonia, Barcelona, Spain","institution_ids":["https://openalex.org/I9617848"]},{"raw_affiliation_string":"Automatic Control Department, Technical University of Catalonia, Pau Gargallo 5, 08028 Barcelona, Spain#TAB#","institution_ids":["https://openalex.org/I9617848"]}]},{"author_position":"middle","author":{"id":"https://openalex.org/A5040587018","display_name":"Josep M. Fuertes","orcid":null},"institutions":[{"id":"https://openalex.org/I9617848","display_name":"Universitat Polit\u00e8cnica de Catalunya","ror":"https://ror.org/03mb6wj31","country_code":"ES","type":"education","lineage":["https://openalex.org/I9617848"]}],"countries":["ES"],"is_corresponding":false,"raw_author_name":"Josep M. Fuertes","raw_affiliation_strings":["Automatic Control Department, Technical University of Catalonia, Barcelona, Spain","Automatic Control Department, Technical University of Catalonia, Pau Gargallo 5, 08028 Barcelona, Spain#TAB#"],"affiliations":[{"raw_affiliation_string":"Automatic Control Department, Technical University of Catalonia, Barcelona, Spain","institution_ids":["https://openalex.org/I9617848"]},{"raw_affiliation_string":"Automatic Control Department, Technical University of Catalonia, Pau Gargallo 5, 08028 Barcelona, Spain#TAB#","institution_ids":["https://openalex.org/I9617848"]}]},{"author_position":"middle","author":{"id":"https://openalex.org/A5061814615","display_name":"Antonio Camacho","orcid":"https://orcid.org/0000-0002-0673-6452"},"institutions":[{"id":"https://openalex.org/I9617848","display_name":"Universitat Polit\u00e8cnica de Catalunya","ror":"https://ror.org/03mb6wj31","country_code":"ES","type":"education","lineage":["https://openalex.org/I9617848"]}],"countries":["ES"],"is_corresponding":false,"raw_author_name":"Antonio Camacho","raw_affiliation_strings":["Department of Electronic Engineering, Technical University of Catalonia, Vilanova i la Geltru, Spain","Department of Electronic Engineering, Technical University of Catalonia, Av. Victor Balaguer s/n, 08800 Vilanova i la Geltr\u00fa, Spain"],"affiliations":[{"raw_affiliation_string":"Department of Electronic Engineering, Technical University of Catalonia, Vilanova i la Geltru, Spain","institution_ids":["https://openalex.org/I9617848"]},{"raw_affiliation_string":"Department of Electronic Engineering, Technical University of Catalonia, Av. Victor Balaguer s/n, 08800 Vilanova i la Geltr\u00fa, Spain","institution_ids":["https://openalex.org/I9617848"]}]},{"author_position":"middle","author":{"id":"https://openalex.org/A5043251354","display_name":"Jaume Miret","orcid":"https://orcid.org/0000-0003-1175-4900"},"institutions":[{"id":"https://openalex.org/I9617848","display_name":"Universitat Polit\u00e8cnica de Catalunya","ror":"https://ror.org/03mb6wj31","country_code":"ES","type":"education","lineage":["https://openalex.org/I9617848"]}],"countries":["ES"],"is_corresponding":false,"raw_author_name":"Jaume Miret","raw_affiliation_strings":["Department of Electronic Engineering, Technical University of Catalonia, Vilanova i la Geltru, Spain","Department of Electronic Engineering, Technical University of Catalonia, Av. Victor Balaguer s/n, 08800 Vilanova i la Geltr\u00fa, Spain"],"affiliations":[{"raw_affiliation_string":"Department of Electronic Engineering, Technical University of Catalonia, Vilanova i la Geltru, Spain","institution_ids":["https://openalex.org/I9617848"]},{"raw_affiliation_string":"Department of Electronic Engineering, Technical University of Catalonia, Av. Victor Balaguer s/n, 08800 Vilanova i la Geltr\u00fa, Spain","institution_ids":["https://openalex.org/I9617848"]}]},{"author_position":"last","author":{"id":"https://openalex.org/A5051254575","display_name":"Miguel Castilla","orcid":"https://orcid.org/0000-0002-3284-860X"},"institutions":[{"id":"https://openalex.org/I9617848","display_name":"Universitat Polit\u00e8cnica de Catalunya","ror":"https://ror.org/03mb6wj31","country_code":"ES","type":"education","lineage":["https://openalex.org/I9617848"]}],"countries":["ES"],"is_corresponding":false,"raw_author_name":"Miguel Castilla","raw_affiliation_strings":["Department of Electronic Engineering, Technical University of Catalonia, Vilanova i la Geltru, Spain","Department of Electronic Engineering, Technical University of Catalonia, Av. Victor Balaguer s/n, 08800 Vilanova i la Geltr\u00fa, Spain"],"affiliations":[{"raw_affiliation_string":"Department of Electronic Engineering, Technical University of Catalonia, Vilanova i la Geltru, Spain","institution_ids":["https://openalex.org/I9617848"]},{"raw_affiliation_string":"Department of Electronic Engineering, Technical University of Catalonia, Av. Victor Balaguer s/n, 08800 Vilanova i la Geltr\u00fa, Spain","institution_ids":["https://openalex.org/I9617848"]}]}],"institutions":[],"countries_distinct_count":1,"institutions_distinct_count":6,"corresponding_author_ids":["https://openalex.org/A5035831255"],"corresponding_institution_ids":["https://openalex.org/I9617848"],"apc_list":null,"apc_paid":null,"fwci":2.0344,"has_fulltext":false,"cited_by_count":8,"citation_normalized_percentile":{"value":0.88330873,"is_in_top_1_percent":false,"is_in_top_10_percent":false},"cited_by_percentile_year":{"min":89,"max":96},"biblio":{"volume":null,"issue":null,"first_page":"1","last_page":"6"},"is_retracted":false,"is_paratext":false,"is_xpac":false,"primary_topic":{"id":"https://openalex.org/T10223","display_name":"Microgrid Control and Optimization","score":0.9998999834060669,"subfield":{"id":"https://openalex.org/subfields/2207","display_name":"Control and Systems Engineering"},"field":{"id":"https://openalex.org/fields/22","display_name":"Engineering"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}},"topics":[{"id":"https://openalex.org/T10223","display_name":"Microgrid Control and Optimization","score":0.9998999834060669,"subfield":{"id":"https://openalex.org/subfields/2207","display_name":"Control and Systems Engineering"},"field":{"id":"https://openalex.org/fields/22","display_name":"Engineering"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}},{"id":"https://openalex.org/T10603","display_name":"Smart Grid Energy Management","score":0.9991999864578247,"subfield":{"id":"https://openalex.org/subfields/2208","display_name":"Electrical and Electronic Engineering"},"field":{"id":"https://openalex.org/fields/22","display_name":"Engineering"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}},{"id":"https://openalex.org/T10454","display_name":"Optimal Power Flow Distribution","score":0.9983999729156494,"subfield":{"id":"https://openalex.org/subfields/2208","display_name":"Electrical and Electronic Engineering"},"field":{"id":"https://openalex.org/fields/22","display_name":"Engineering"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}}],"keywords":[{"id":"https://openalex.org/keywords/ac-power","display_name":"AC power","score":0.7438846826553345},{"id":"https://openalex.org/keywords/voltage-optimisation","display_name":"Voltage optimisation","score":0.6345868706703186},{"id":"https://openalex.org/keywords/photovoltaic-system","display_name":"Photovoltaic system","score":0.5960584282875061},{"id":"https://openalex.org/keywords/distributed-generation","display_name":"Distributed generation","score":0.565872311592102},{"id":"https://openalex.org/keywords/computer-science","display_name":"Computer science","score":0.5608519315719604},{"id":"https://openalex.org/keywords/power-control","display_name":"Power control","score":0.5407125949859619},{"id":"https://openalex.org/keywords/voltage-regulation","display_name":"Voltage regulation","score":0.5378363132476807},{"id":"https://openalex.org/keywords/voltage","display_name":"Voltage","score":0.5053215622901917},{"id":"https://openalex.org/keywords/grid-connection","display_name":"Grid connection","score":0.5034093260765076},{"id":"https://openalex.org/keywords/electrical-engineering","display_name":"Electrical engineering","score":0.44482287764549255},{"id":"https://openalex.org/keywords/grid","display_name":"Grid","score":0.44205519556999207},{"id":"https://openalex.org/keywords/electricity-generation","display_name":"Electricity generation","score":0.4404464662075043},{"id":"https://openalex.org/keywords/grid-connected-photovoltaic-power-system","display_name":"Grid-connected photovoltaic power system","score":0.42577216029167175},{"id":"https://openalex.org/keywords/volt-ampere-reactive","display_name":"Volt-ampere reactive","score":0.42153623700141907},{"id":"https://openalex.org/keywords/power","display_name":"Power (physics)","score":0.38533830642700195},{"id":"https://openalex.org/keywords/electronic-engineering","display_name":"Electronic engineering","score":0.3689553141593933},{"id":"https://openalex.org/keywords/maximum-power-point-tracking","display_name":"Maximum power point tracking","score":0.3425326943397522},{"id":"https://openalex.org/keywords/engineering","display_name":"Engineering","score":0.31823021173477173},{"id":"https://openalex.org/keywords/renewable-energy","display_name":"Renewable energy","score":0.11987465620040894},{"id":"https://openalex.org/keywords/physics","display_name":"Physics","score":0.06321772933006287}],"concepts":[{"id":"https://openalex.org/C108755667","wikidata":"https://www.wikidata.org/wiki/Q1930258","display_name":"AC power","level":3,"score":0.7438846826553345},{"id":"https://openalex.org/C46529443","wikidata":"https://www.wikidata.org/wiki/Q7940750","display_name":"Voltage optimisation","level":4,"score":0.6345868706703186},{"id":"https://openalex.org/C41291067","wikidata":"https://www.wikidata.org/wiki/Q1897785","display_name":"Photovoltaic system","level":2,"score":0.5960584282875061},{"id":"https://openalex.org/C544738498","wikidata":"https://www.wikidata.org/wiki/Q861135","display_name":"Distributed generation","level":3,"score":0.565872311592102},{"id":"https://openalex.org/C41008148","wikidata":"https://www.wikidata.org/wiki/Q21198","display_name":"Computer science","level":0,"score":0.5608519315719604},{"id":"https://openalex.org/C56685638","wikidata":"https://www.wikidata.org/wiki/Q2300474","display_name":"Power control","level":3,"score":0.5407125949859619},{"id":"https://openalex.org/C196226539","wikidata":"https://www.wikidata.org/wiki/Q7940752","display_name":"Voltage regulation","level":3,"score":0.5378363132476807},{"id":"https://openalex.org/C165801399","wikidata":"https://www.wikidata.org/wiki/Q25428","display_name":"Voltage","level":2,"score":0.5053215622901917},{"id":"https://openalex.org/C2780685028","wikidata":"https://www.wikidata.org/wiki/Q1096907","display_name":"Grid connection","level":3,"score":0.5034093260765076},{"id":"https://openalex.org/C119599485","wikidata":"https://www.wikidata.org/wiki/Q43035","display_name":"Electrical engineering","level":1,"score":0.44482287764549255},{"id":"https://openalex.org/C187691185","wikidata":"https://www.wikidata.org/wiki/Q2020720","display_name":"Grid","level":2,"score":0.44205519556999207},{"id":"https://openalex.org/C423512","wikidata":"https://www.wikidata.org/wiki/Q383973","display_name":"Electricity generation","level":3,"score":0.4404464662075043},{"id":"https://openalex.org/C195697387","wikidata":"https://www.wikidata.org/wiki/Q5608561","display_name":"Grid-connected photovoltaic power system","level":5,"score":0.42577216029167175},{"id":"https://openalex.org/C59407501","wikidata":"https://www.wikidata.org/wiki/Q550341","display_name":"Volt-ampere reactive","level":5,"score":0.42153623700141907},{"id":"https://openalex.org/C163258240","wikidata":"https://www.wikidata.org/wiki/Q25342","display_name":"Power (physics)","level":2,"score":0.38533830642700195},{"id":"https://openalex.org/C24326235","wikidata":"https://www.wikidata.org/wiki/Q126095","display_name":"Electronic engineering","level":1,"score":0.3689553141593933},{"id":"https://openalex.org/C36139824","wikidata":"https://www.wikidata.org/wiki/Q1052007","display_name":"Maximum power point tracking","level":4,"score":0.3425326943397522},{"id":"https://openalex.org/C127413603","wikidata":"https://www.wikidata.org/wiki/Q11023","display_name":"Engineering","level":0,"score":0.31823021173477173},{"id":"https://openalex.org/C188573790","wikidata":"https://www.wikidata.org/wiki/Q12705","display_name":"Renewable energy","level":2,"score":0.11987465620040894},{"id":"https://openalex.org/C121332964","wikidata":"https://www.wikidata.org/wiki/Q413","display_name":"Physics","level":0,"score":0.06321772933006287},{"id":"https://openalex.org/C62520636","wikidata":"https://www.wikidata.org/wiki/Q944","display_name":"Quantum mechanics","level":1,"score":0.0},{"id":"https://openalex.org/C11190779","wikidata":"https://www.wikidata.org/wiki/Q664575","display_name":"Inverter","level":3,"score":0.0},{"id":"https://openalex.org/C2524010","wikidata":"https://www.wikidata.org/wiki/Q8087","display_name":"Geometry","level":1,"score":0.0},{"id":"https://openalex.org/C33923547","wikidata":"https://www.wikidata.org/wiki/Q395","display_name":"Mathematics","level":0,"score":0.0}],"mesh":[],"locations_count":2,"locations":[{"id":"doi:10.1109/isie.2013.6563803","is_oa":false,"landing_page_url":"https://doi.org/10.1109/isie.2013.6563803","pdf_url":null,"source":null,"license":null,"license_id":null,"version":"publishedVersion","is_accepted":true,"is_published":true,"raw_source_name":"2013 IEEE International Symposium on Industrial Electronics","raw_type":"proceedings-article"},{"id":"pmh:oai:upcommons.upc.edu:2117/20254","is_oa":true,"landing_page_url":"https://hdl.handle.net/2117/20254","pdf_url":null,"source":{"id":"https://openalex.org/S4210207057","display_name":"QRU Quaderns de Recerca en Urbanisme","issn_l":"2014-9689","issn":["2014-9689","2385-6777"],"is_oa":true,"is_in_doaj":false,"is_core":false,"host_organization":"https://openalex.org/P4310322448","host_organization_name":"Q71272178","host_organization_lineage":["https://openalex.org/P4310322448"],"host_organization_lineage_names":["Q71272178"],"type":"journal"},"license":"cc-by-nc-nd","license_id":"https://openalex.org/licenses/cc-by-nc-nd","version":"submittedVersion","is_accepted":false,"is_published":false,"raw_source_name":null,"raw_type":"Conference report"}],"best_oa_location":{"id":"pmh:oai:upcommons.upc.edu:2117/20254","is_oa":true,"landing_page_url":"https://hdl.handle.net/2117/20254","pdf_url":null,"source":{"id":"https://openalex.org/S4210207057","display_name":"QRU Quaderns de Recerca en Urbanisme","issn_l":"2014-9689","issn":["2014-9689","2385-6777"],"is_oa":true,"is_in_doaj":false,"is_core":false,"host_organization":"https://openalex.org/P4310322448","host_organization_name":"Q71272178","host_organization_lineage":["https://openalex.org/P4310322448"],"host_organization_lineage_names":["Q71272178"],"type":"journal"},"license":"cc-by-nc-nd","license_id":"https://openalex.org/licenses/cc-by-nc-nd","version":"submittedVersion","is_accepted":false,"is_published":false,"raw_source_name":null,"raw_type":"Conference report"},"sustainable_development_goals":[{"display_name":"Industry, innovation and infrastructure","id":"https://metadata.un.org/sdg/9","score":0.550000011920929}],"awards":[],"funders":[],"has_content":{"pdf":false,"grobid_xml":false},"content_urls":null,"referenced_works_count":24,"referenced_works":["https://openalex.org/W1597530601","https://openalex.org/W1864047636","https://openalex.org/W1970676140","https://openalex.org/W1990492651","https://openalex.org/W1993492456","https://openalex.org/W1998572623","https://openalex.org/W2046928418","https://openalex.org/W2050427013","https://openalex.org/W2055593572","https://openalex.org/W2107529670","https://openalex.org/W2111212237","https://openalex.org/W2120825160","https://openalex.org/W2130820962","https://openalex.org/W2147727848","https://openalex.org/W2153575149","https://openalex.org/W2162226798","https://openalex.org/W2162814194","https://openalex.org/W2340742279","https://openalex.org/W3148453538","https://openalex.org/W4251645464","https://openalex.org/W4253954259","https://openalex.org/W6635751221","https://openalex.org/W6647728970","https://openalex.org/W6963693682"],"related_works":["https://openalex.org/W2740618342","https://openalex.org/W3019765971","https://openalex.org/W2034600866","https://openalex.org/W4221095389","https://openalex.org/W4284711461","https://openalex.org/W4376457885","https://openalex.org/W2393545836","https://openalex.org/W2383413209","https://openalex.org/W3003861339","https://openalex.org/W2165471520"],"abstract_inverted_index":{"A":[0],"high":[1],"density":[2],"of":[3,19,71,79,89,116],"grid-connected":[4],"photovoltaic":[5],"(PV)":[6],"power":[7,46,51,92,122],"generation":[8,21],"systems":[9],"is":[10],"expected":[11],"to":[12,40,57,82],"occur":[13],"in":[14,27],"urban":[15],"areas.":[16],"The":[17],"connection":[18],"distributed":[20,120],"(DG)":[22],"may":[23,101],"cause":[24],"serious":[25],"problems":[26],"the":[28,42,45,63,69,76,87,130],"distribution":[29],"system":[30],"such":[31],"as":[32],"voltage":[33,36,65],"rise.":[34],"Several":[35],"control":[37,52,93,96,123],"strategies":[38],"exist":[39],"avoid":[41],"over-voltage":[43],"at":[44,98],"grid.":[47],"In":[48,74],"particular,":[49],"reactive":[50,91,121],"methods":[53,94,124],"have":[54,126],"been":[55,127],"proved":[56],"successfully":[58],"bring":[59],"DGs":[60,84],"voltages":[61],"within":[62],"admissible":[64],"range":[66],"without":[67],"reducing":[68],"production":[70],"active":[72],"power.":[73],"addition,":[75],"possible":[77],"use":[78],"communication":[80,137],"infrastructure":[81],"link":[83],"opens":[85],"up":[86],"development":[88],"new":[90],"where":[95],"actions":[97],"each":[99],"DG":[100],"be":[102],"decided":[103],"using":[104],"both":[105],"local":[106],"and":[107,118],"global":[108],"information.":[109],"This":[110],"paper":[111],"presents":[112],"a":[113,136],"comparative":[114],"study":[115],"existing":[117],"novel":[119],"that":[125],"designed":[128],"exploiting":[129],"information":[131],"exchange":[132],"facility":[133],"provided":[134],"by":[135],"infrastructure.":[138]},"counts_by_year":[{"year":2021,"cited_by_count":1},{"year":2019,"cited_by_count":2},{"year":2017,"cited_by_count":1},{"year":2016,"cited_by_count":1},{"year":2015,"cited_by_count":2},{"year":2014,"cited_by_count":1}],"updated_date":"2026-04-14T08:04:32.555800","created_date":"2025-10-10T00:00:00"}
