{"id":"https://openalex.org/W2094202802","doi":"https://doi.org/10.1109/isie.2013.6563732","title":"An improved reactive power control strategy for inverters in microgrids","display_name":"An improved reactive power control strategy for inverters in microgrids","publication_year":2013,"publication_date":"2013-05-01","ids":{"openalex":"https://openalex.org/W2094202802","doi":"https://doi.org/10.1109/isie.2013.6563732","mag":"2094202802"},"language":"en","primary_location":{"id":"doi:10.1109/isie.2013.6563732","is_oa":false,"landing_page_url":"https://doi.org/10.1109/isie.2013.6563732","pdf_url":null,"source":null,"license":null,"license_id":null,"version":"publishedVersion","is_accepted":true,"is_published":true,"raw_source_name":"2013 IEEE International Symposium on Industrial Electronics","raw_type":"proceedings-article"},"type":"article","indexed_in":["crossref"],"open_access":{"is_oa":false,"oa_status":"closed","oa_url":null,"any_repository_has_fulltext":false},"authorships":[{"author_position":"first","author":{"id":"https://openalex.org/A5100405781","display_name":"Ping Zhang","orcid":"https://orcid.org/0000-0001-9163-6191"},"institutions":[{"id":"https://openalex.org/I76130692","display_name":"Zhejiang University","ror":"https://ror.org/00a2xv884","country_code":"CN","type":"education","lineage":["https://openalex.org/I76130692"]}],"countries":["CN"],"is_corresponding":true,"raw_author_name":"Ping Zhang","raw_affiliation_strings":["College of Electrical Engineering, Zhejiang University, Hangzhou, China","College of Electrical Engineering, ZheJiang University, Hangzhou, china"],"affiliations":[{"raw_affiliation_string":"College of Electrical Engineering, Zhejiang University, Hangzhou, China","institution_ids":["https://openalex.org/I76130692"]},{"raw_affiliation_string":"College of Electrical Engineering, ZheJiang University, Hangzhou, china","institution_ids":["https://openalex.org/I76130692"]}]},{"author_position":"middle","author":{"id":"https://openalex.org/A5070887372","display_name":"Ronggui Li","orcid":"https://orcid.org/0000-0003-2606-0792"},"institutions":[{"id":"https://openalex.org/I76130692","display_name":"Zhejiang University","ror":"https://ror.org/00a2xv884","country_code":"CN","type":"education","lineage":["https://openalex.org/I76130692"]}],"countries":["CN"],"is_corresponding":false,"raw_author_name":"Ronggui Li","raw_affiliation_strings":["College of Electrical Engineering, Zhejiang University, Hangzhou, China","College of Electrical Engineering, ZheJiang University, Hangzhou, china"],"affiliations":[{"raw_affiliation_string":"College of Electrical Engineering, Zhejiang University, Hangzhou, China","institution_ids":["https://openalex.org/I76130692"]},{"raw_affiliation_string":"College of Electrical Engineering, ZheJiang University, Hangzhou, china","institution_ids":["https://openalex.org/I76130692"]}]},{"author_position":"middle","author":{"id":"https://openalex.org/A5102134986","display_name":"Jianjiang Shi","orcid":null},"institutions":[{"id":"https://openalex.org/I76130692","display_name":"Zhejiang University","ror":"https://ror.org/00a2xv884","country_code":"CN","type":"education","lineage":["https://openalex.org/I76130692"]}],"countries":["CN"],"is_corresponding":false,"raw_author_name":"Jianjiang Shi","raw_affiliation_strings":["College of Electrical Engineering, Zhejiang University, Hangzhou, China","College of Electrical Engineering, ZheJiang University, Hangzhou, china"],"affiliations":[{"raw_affiliation_string":"College of Electrical Engineering, Zhejiang University, Hangzhou, China","institution_ids":["https://openalex.org/I76130692"]},{"raw_affiliation_string":"College of Electrical Engineering, ZheJiang University, Hangzhou, china","institution_ids":["https://openalex.org/I76130692"]}]},{"author_position":"last","author":{"id":"https://openalex.org/A5082049172","display_name":"Xiangning He","orcid":"https://orcid.org/0000-0002-0953-0097"},"institutions":[{"id":"https://openalex.org/I76130692","display_name":"Zhejiang University","ror":"https://ror.org/00a2xv884","country_code":"CN","type":"education","lineage":["https://openalex.org/I76130692"]}],"countries":["CN"],"is_corresponding":false,"raw_author_name":"Xiangning He","raw_affiliation_strings":["College of Electrical Engineering, Zhejiang University, Hangzhou, China","College of Electrical Engineering, ZheJiang University, Hangzhou, china"],"affiliations":[{"raw_affiliation_string":"College of Electrical Engineering, Zhejiang University, Hangzhou, China","institution_ids":["https://openalex.org/I76130692"]},{"raw_affiliation_string":"College of Electrical Engineering, ZheJiang University, Hangzhou, china","institution_ids":["https://openalex.org/I76130692"]}]}],"institutions":[],"countries_distinct_count":1,"institutions_distinct_count":4,"corresponding_author_ids":["https://openalex.org/A5100405781"],"corresponding_institution_ids":["https://openalex.org/I76130692"],"apc_list":null,"apc_paid":null,"fwci":1.5149,"has_fulltext":false,"cited_by_count":7,"citation_normalized_percentile":{"value":0.85696206,"is_in_top_1_percent":false,"is_in_top_10_percent":false},"cited_by_percentile_year":{"min":89,"max":95},"biblio":{"volume":null,"issue":null,"first_page":"1","last_page":"6"},"is_retracted":false,"is_paratext":false,"is_xpac":false,"primary_topic":{"id":"https://openalex.org/T10223","display_name":"Microgrid Control and Optimization","score":1.0,"subfield":{"id":"https://openalex.org/subfields/2207","display_name":"Control and Systems Engineering"},"field":{"id":"https://openalex.org/fields/22","display_name":"Engineering"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}},"topics":[{"id":"https://openalex.org/T10223","display_name":"Microgrid Control and Optimization","score":1.0,"subfield":{"id":"https://openalex.org/subfields/2207","display_name":"Control and Systems Engineering"},"field":{"id":"https://openalex.org/fields/22","display_name":"Engineering"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}},{"id":"https://openalex.org/T13183","display_name":"Islanding Detection in Power Systems","score":0.9912999868392944,"subfield":{"id":"https://openalex.org/subfields/2208","display_name":"Electrical and Electronic Engineering"},"field":{"id":"https://openalex.org/fields/22","display_name":"Engineering"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}},{"id":"https://openalex.org/T10603","display_name":"Smart Grid Energy Management","score":0.9822999835014343,"subfield":{"id":"https://openalex.org/subfields/2208","display_name":"Electrical and Electronic Engineering"},"field":{"id":"https://openalex.org/fields/22","display_name":"Engineering"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}}],"keywords":[{"id":"https://openalex.org/keywords/voltage-droop","display_name":"Voltage droop","score":0.9243472814559937},{"id":"https://openalex.org/keywords/ac-power","display_name":"AC power","score":0.7770453691482544},{"id":"https://openalex.org/keywords/control-theory","display_name":"Control theory (sociology)","score":0.7184632420539856},{"id":"https://openalex.org/keywords/voltage-source","display_name":"Voltage source","score":0.6490031480789185},{"id":"https://openalex.org/keywords/output-impedance","display_name":"Output impedance","score":0.5607967376708984},{"id":"https://openalex.org/keywords/inductance","display_name":"Inductance","score":0.545307457447052},{"id":"https://openalex.org/keywords/microgrid","display_name":"Microgrid","score":0.5160965323448181},{"id":"https://openalex.org/keywords/electrical-impedance","display_name":"Electrical impedance","score":0.5042160749435425},{"id":"https://openalex.org/keywords/voltage","display_name":"Voltage","score":0.4569381773471832},{"id":"https://openalex.org/keywords/volt-ampere-reactive","display_name":"Volt-ampere reactive","score":0.4256626069545746},{"id":"https://openalex.org/keywords/power","display_name":"Power (physics)","score":0.4243416488170624},{"id":"https://openalex.org/keywords/computer-science","display_name":"Computer science","score":0.4169290065765381},{"id":"https://openalex.org/keywords/power-factor","display_name":"Power factor","score":0.41372302174568176},{"id":"https://openalex.org/keywords/engineering","display_name":"Engineering","score":0.3649154603481293},{"id":"https://openalex.org/keywords/voltage-optimisation","display_name":"Voltage optimisation","score":0.34252795577049255},{"id":"https://openalex.org/keywords/electrical-engineering","display_name":"Electrical engineering","score":0.17593839764595032},{"id":"https://openalex.org/keywords/control","display_name":"Control (management)","score":0.1368546485900879},{"id":"https://openalex.org/keywords/physics","display_name":"Physics","score":0.10491642355918884}],"concepts":[{"id":"https://openalex.org/C40760162","wikidata":"https://www.wikidata.org/wiki/Q10920295","display_name":"Voltage droop","level":4,"score":0.9243472814559937},{"id":"https://openalex.org/C108755667","wikidata":"https://www.wikidata.org/wiki/Q1930258","display_name":"AC power","level":3,"score":0.7770453691482544},{"id":"https://openalex.org/C47446073","wikidata":"https://www.wikidata.org/wiki/Q5165890","display_name":"Control theory (sociology)","level":3,"score":0.7184632420539856},{"id":"https://openalex.org/C144655898","wikidata":"https://www.wikidata.org/wiki/Q1161128","display_name":"Voltage source","level":3,"score":0.6490031480789185},{"id":"https://openalex.org/C58112919","wikidata":"https://www.wikidata.org/wiki/Q631203","display_name":"Output impedance","level":3,"score":0.5607967376708984},{"id":"https://openalex.org/C29210110","wikidata":"https://www.wikidata.org/wiki/Q177897","display_name":"Inductance","level":3,"score":0.545307457447052},{"id":"https://openalex.org/C2776784348","wikidata":"https://www.wikidata.org/wiki/Q5762595","display_name":"Microgrid","level":3,"score":0.5160965323448181},{"id":"https://openalex.org/C17829176","wikidata":"https://www.wikidata.org/wiki/Q179043","display_name":"Electrical impedance","level":2,"score":0.5042160749435425},{"id":"https://openalex.org/C165801399","wikidata":"https://www.wikidata.org/wiki/Q25428","display_name":"Voltage","level":2,"score":0.4569381773471832},{"id":"https://openalex.org/C59407501","wikidata":"https://www.wikidata.org/wiki/Q550341","display_name":"Volt-ampere reactive","level":5,"score":0.4256626069545746},{"id":"https://openalex.org/C163258240","wikidata":"https://www.wikidata.org/wiki/Q25342","display_name":"Power (physics)","level":2,"score":0.4243416488170624},{"id":"https://openalex.org/C41008148","wikidata":"https://www.wikidata.org/wiki/Q21198","display_name":"Computer science","level":0,"score":0.4169290065765381},{"id":"https://openalex.org/C64424096","wikidata":"https://www.wikidata.org/wiki/Q750454","display_name":"Power factor","level":3,"score":0.41372302174568176},{"id":"https://openalex.org/C127413603","wikidata":"https://www.wikidata.org/wiki/Q11023","display_name":"Engineering","level":0,"score":0.3649154603481293},{"id":"https://openalex.org/C46529443","wikidata":"https://www.wikidata.org/wiki/Q7940750","display_name":"Voltage optimisation","level":4,"score":0.34252795577049255},{"id":"https://openalex.org/C119599485","wikidata":"https://www.wikidata.org/wiki/Q43035","display_name":"Electrical engineering","level":1,"score":0.17593839764595032},{"id":"https://openalex.org/C2775924081","wikidata":"https://www.wikidata.org/wiki/Q55608371","display_name":"Control (management)","level":2,"score":0.1368546485900879},{"id":"https://openalex.org/C121332964","wikidata":"https://www.wikidata.org/wiki/Q413","display_name":"Physics","level":0,"score":0.10491642355918884},{"id":"https://openalex.org/C154945302","wikidata":"https://www.wikidata.org/wiki/Q11660","display_name":"Artificial intelligence","level":1,"score":0.0},{"id":"https://openalex.org/C62520636","wikidata":"https://www.wikidata.org/wiki/Q944","display_name":"Quantum mechanics","level":1,"score":0.0}],"mesh":[],"locations_count":1,"locations":[{"id":"doi:10.1109/isie.2013.6563732","is_oa":false,"landing_page_url":"https://doi.org/10.1109/isie.2013.6563732","pdf_url":null,"source":null,"license":null,"license_id":null,"version":"publishedVersion","is_accepted":true,"is_published":true,"raw_source_name":"2013 IEEE International Symposium on Industrial Electronics","raw_type":"proceedings-article"}],"best_oa_location":null,"sustainable_development_goals":[{"display_name":"Affordable and clean energy","id":"https://metadata.un.org/sdg/7","score":0.8700000047683716}],"awards":[],"funders":[],"has_content":{"grobid_xml":false,"pdf":false},"content_urls":null,"referenced_works_count":9,"referenced_works":["https://openalex.org/W2099373322","https://openalex.org/W2103943551","https://openalex.org/W2105806216","https://openalex.org/W2108326722","https://openalex.org/W2124708943","https://openalex.org/W2146819726","https://openalex.org/W2149392049","https://openalex.org/W2168753575","https://openalex.org/W4232284745"],"related_works":["https://openalex.org/W1970562241","https://openalex.org/W2507420394","https://openalex.org/W2077073890","https://openalex.org/W2269166041","https://openalex.org/W2977399316","https://openalex.org/W2409882009","https://openalex.org/W2980232854","https://openalex.org/W2377000424","https://openalex.org/W3024702869","https://openalex.org/W4386072451"],"abstract_inverted_index":{"Due":[0],"to":[1,37,69,102,159,201],"the":[2,6,39,42,47,50,54,58,64,77,80,90,104,120,123,130,151,154,160,164,167,173,188,203],"different":[3],"system":[4,82,106,156],"impedance,":[5,118],"conventional":[7,51],"droop":[8,32,52,87,141],"control":[9,16,33,147,193],"scheme":[10],"cannot":[11],"achieve":[12],"accurate":[13],"sharing":[14,191],"and":[15,63,125,128,192,196],"of":[17,41,57,92],"reactive":[18,43,65,93,126,189],"power":[19,44,66,94,127,190],"among":[20,73,134],"voltage-source":[21],"inverters":[22],"(VSIs)":[23],"in":[24,111,177],"microgrid":[25],"(MG).":[26],"In":[27],"this":[28],"paper,":[29],"a":[30,85,97,112,138],"new":[31],"strategy":[34,48,184],"is":[35,67,100,148,157],"proposed":[36,183,204],"raise":[38],"accuracy":[40],"control.":[45],"Firstly,":[46],"eliminates":[49],"for":[53],"reference":[55],"voltage":[56,139,175],"VSI":[59,155],"under":[60],"no":[61],"load,":[62],"left":[68],"be":[70],"actually":[71],"shared":[72],"VSIs":[74],"based":[75,162],"on":[76,163],"truth":[78],"that":[79,166],"inductive":[81,109],"impedance":[83,107],"presents":[84],"natural":[86],"characteristic":[88],"as":[89],"output":[91],"increases.":[95],"Secondly,":[96],"virtual":[98],"inductance":[99],"introduced":[101],"make":[103],"whole":[105,168],"predominantly":[108],"even":[110],"low-voltage":[113],"network":[114],"with":[115,143],"resistive":[116],"line":[117],"preventing":[119],"coupling":[121],"between":[122],"real":[124],"suppressing":[129],"circulating":[131],"current":[132],"quickly":[133],"paralleled":[135],"VSIs.":[136],"Finally,":[137],"amplitude":[140,176],"loop":[142],"zero":[144],"steady-state":[145],"error":[146],"employed":[149],"at":[150],"point":[152],"where":[153],"connected":[158],"MG":[161],"fact":[165],"ac":[169],"bus":[170],"has":[171],"approximately":[172],"same":[174],"well-regulated":[178],"or":[179],"small-scale":[180],"MGs.":[181],"The":[182],"can":[185],"effectively":[186],"improve":[187],"accuracy.":[194],"Simulation":[195],"experimental":[197],"results":[198],"are":[199],"given":[200],"validate":[202],"strategy.":[205]},"counts_by_year":[{"year":2025,"cited_by_count":1},{"year":2024,"cited_by_count":1},{"year":2021,"cited_by_count":1},{"year":2017,"cited_by_count":1},{"year":2016,"cited_by_count":1},{"year":2015,"cited_by_count":1},{"year":2014,"cited_by_count":1}],"updated_date":"2025-11-06T03:46:38.306776","created_date":"2025-10-10T00:00:00"}
