{"id":"https://openalex.org/W1963815333","doi":"https://doi.org/10.1109/isic.2012.6398254","title":"Observer-based fault isolation for statically non-isolable linear systems","display_name":"Observer-based fault isolation for statically non-isolable linear systems","publication_year":2012,"publication_date":"2012-10-01","ids":{"openalex":"https://openalex.org/W1963815333","doi":"https://doi.org/10.1109/isic.2012.6398254","mag":"1963815333"},"language":"en","primary_location":{"id":"doi:10.1109/isic.2012.6398254","is_oa":false,"landing_page_url":"https://doi.org/10.1109/isic.2012.6398254","pdf_url":null,"source":null,"license":null,"license_id":null,"version":"publishedVersion","is_accepted":true,"is_published":true,"raw_source_name":"2012 IEEE International Symposium on Intelligent Control","raw_type":"proceedings-article"},"type":"article","indexed_in":["crossref"],"open_access":{"is_oa":false,"oa_status":"closed","oa_url":null,"any_repository_has_fulltext":false},"authorships":[{"author_position":"first","author":{"id":"https://openalex.org/A5084721587","display_name":"Arne Wahrburg","orcid":"https://orcid.org/0000-0002-1622-002X"},"institutions":[{"id":"https://openalex.org/I31512782","display_name":"Technical University of Darmstadt","ror":"https://ror.org/05n911h24","country_code":"DE","type":"education","lineage":["https://openalex.org/I31512782"]}],"countries":["DE"],"is_corresponding":true,"raw_author_name":"Arne Wahrburg","raw_affiliation_strings":["Institute of Automatic Control, Technische Universit\u00e4t Darmstadt, Darmstadt, Germany","Institute of Automatic Control, Technische Universit\u00e4t Darmstadt, Landgraf-Georg-Str. 4, 64283, GERMANY"],"affiliations":[{"raw_affiliation_string":"Institute of Automatic Control, Technische Universit\u00e4t Darmstadt, Darmstadt, Germany","institution_ids":["https://openalex.org/I31512782"]},{"raw_affiliation_string":"Institute of Automatic Control, Technische Universit\u00e4t Darmstadt, Landgraf-Georg-Str. 4, 64283, GERMANY","institution_ids":["https://openalex.org/I31512782"]}]},{"author_position":"last","author":{"id":"https://openalex.org/A5018434031","display_name":"J\u00fcrgen Adamy","orcid":"https://orcid.org/0000-0001-5612-4932"},"institutions":[{"id":"https://openalex.org/I31512782","display_name":"Technical University of Darmstadt","ror":"https://ror.org/05n911h24","country_code":"DE","type":"education","lineage":["https://openalex.org/I31512782"]}],"countries":["DE"],"is_corresponding":false,"raw_author_name":"Jurgen Adamy","raw_affiliation_strings":["Institute of Automatic Control, Technische Universit\u00e4t Darmstadt, Darmstadt, Germany","Institute of Automatic Control, Technische Universit\u00e4t Darmstadt, Landgraf-Georg-Str. 4, 64283, GERMANY"],"affiliations":[{"raw_affiliation_string":"Institute of Automatic Control, Technische Universit\u00e4t Darmstadt, Darmstadt, Germany","institution_ids":["https://openalex.org/I31512782"]},{"raw_affiliation_string":"Institute of Automatic Control, Technische Universit\u00e4t Darmstadt, Landgraf-Georg-Str. 4, 64283, GERMANY","institution_ids":["https://openalex.org/I31512782"]}]}],"institutions":[],"countries_distinct_count":1,"institutions_distinct_count":2,"corresponding_author_ids":["https://openalex.org/A5084721587"],"corresponding_institution_ids":["https://openalex.org/I31512782"],"apc_list":null,"apc_paid":null,"fwci":3.3782,"has_fulltext":false,"cited_by_count":7,"citation_normalized_percentile":{"value":0.91890481,"is_in_top_1_percent":false,"is_in_top_10_percent":true},"cited_by_percentile_year":{"min":89,"max":96},"biblio":{"volume":"36","issue":null,"first_page":"1207","last_page":"1213"},"is_retracted":false,"is_paratext":false,"is_xpac":false,"primary_topic":{"id":"https://openalex.org/T10876","display_name":"Fault Detection and Control Systems","score":1.0,"subfield":{"id":"https://openalex.org/subfields/2207","display_name":"Control and Systems Engineering"},"field":{"id":"https://openalex.org/fields/22","display_name":"Engineering"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}},"topics":[{"id":"https://openalex.org/T10876","display_name":"Fault Detection and Control Systems","score":1.0,"subfield":{"id":"https://openalex.org/subfields/2207","display_name":"Control and Systems Engineering"},"field":{"id":"https://openalex.org/fields/22","display_name":"Engineering"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}},{"id":"https://openalex.org/T10791","display_name":"Advanced Control Systems Optimization","score":0.9933000206947327,"subfield":{"id":"https://openalex.org/subfields/2207","display_name":"Control and Systems Engineering"},"field":{"id":"https://openalex.org/fields/22","display_name":"Engineering"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}},{"id":"https://openalex.org/T14470","display_name":"Advanced Data Processing Techniques","score":0.9804999828338623,"subfield":{"id":"https://openalex.org/subfields/2207","display_name":"Control and Systems Engineering"},"field":{"id":"https://openalex.org/fields/22","display_name":"Engineering"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}}],"keywords":[{"id":"https://openalex.org/keywords/fault-detection-and-isolation","display_name":"Fault detection and isolation","score":0.7738234996795654},{"id":"https://openalex.org/keywords/observer","display_name":"Observer (physics)","score":0.7651031613349915},{"id":"https://openalex.org/keywords/actuator","display_name":"Actuator","score":0.7281385660171509},{"id":"https://openalex.org/keywords/isolation","display_name":"Isolation (microbiology)","score":0.7119768261909485},{"id":"https://openalex.org/keywords/computer-science","display_name":"Computer science","score":0.5625160932540894},{"id":"https://openalex.org/keywords/linear-system","display_name":"Linear system","score":0.5507053136825562},{"id":"https://openalex.org/keywords/control-theory","display_name":"Control theory (sociology)","score":0.5233591794967651},{"id":"https://openalex.org/keywords/fault","display_name":"Fault (geology)","score":0.47640788555145264},{"id":"https://openalex.org/keywords/control-engineering","display_name":"Control engineering","score":0.3970659375190735},{"id":"https://openalex.org/keywords/engineering","display_name":"Engineering","score":0.24404707551002502},{"id":"https://openalex.org/keywords/mathematics","display_name":"Mathematics","score":0.20889747142791748},{"id":"https://openalex.org/keywords/control","display_name":"Control (management)","score":0.14492791891098022},{"id":"https://openalex.org/keywords/artificial-intelligence","display_name":"Artificial intelligence","score":0.13496950268745422}],"concepts":[{"id":"https://openalex.org/C152745839","wikidata":"https://www.wikidata.org/wiki/Q5438153","display_name":"Fault detection and isolation","level":3,"score":0.7738234996795654},{"id":"https://openalex.org/C2780704645","wikidata":"https://www.wikidata.org/wiki/Q9251458","display_name":"Observer (physics)","level":2,"score":0.7651031613349915},{"id":"https://openalex.org/C172707124","wikidata":"https://www.wikidata.org/wiki/Q423488","display_name":"Actuator","level":2,"score":0.7281385660171509},{"id":"https://openalex.org/C2775941552","wikidata":"https://www.wikidata.org/wiki/Q25212305","display_name":"Isolation (microbiology)","level":2,"score":0.7119768261909485},{"id":"https://openalex.org/C41008148","wikidata":"https://www.wikidata.org/wiki/Q21198","display_name":"Computer science","level":0,"score":0.5625160932540894},{"id":"https://openalex.org/C6802819","wikidata":"https://www.wikidata.org/wiki/Q1072174","display_name":"Linear system","level":2,"score":0.5507053136825562},{"id":"https://openalex.org/C47446073","wikidata":"https://www.wikidata.org/wiki/Q5165890","display_name":"Control theory (sociology)","level":3,"score":0.5233591794967651},{"id":"https://openalex.org/C175551986","wikidata":"https://www.wikidata.org/wiki/Q47089","display_name":"Fault (geology)","level":2,"score":0.47640788555145264},{"id":"https://openalex.org/C133731056","wikidata":"https://www.wikidata.org/wiki/Q4917288","display_name":"Control engineering","level":1,"score":0.3970659375190735},{"id":"https://openalex.org/C127413603","wikidata":"https://www.wikidata.org/wiki/Q11023","display_name":"Engineering","level":0,"score":0.24404707551002502},{"id":"https://openalex.org/C33923547","wikidata":"https://www.wikidata.org/wiki/Q395","display_name":"Mathematics","level":0,"score":0.20889747142791748},{"id":"https://openalex.org/C2775924081","wikidata":"https://www.wikidata.org/wiki/Q55608371","display_name":"Control (management)","level":2,"score":0.14492791891098022},{"id":"https://openalex.org/C154945302","wikidata":"https://www.wikidata.org/wiki/Q11660","display_name":"Artificial intelligence","level":1,"score":0.13496950268745422},{"id":"https://openalex.org/C127313418","wikidata":"https://www.wikidata.org/wiki/Q1069","display_name":"Geology","level":0,"score":0.0},{"id":"https://openalex.org/C165205528","wikidata":"https://www.wikidata.org/wiki/Q83371","display_name":"Seismology","level":1,"score":0.0},{"id":"https://openalex.org/C121332964","wikidata":"https://www.wikidata.org/wiki/Q413","display_name":"Physics","level":0,"score":0.0},{"id":"https://openalex.org/C62520636","wikidata":"https://www.wikidata.org/wiki/Q944","display_name":"Quantum mechanics","level":1,"score":0.0},{"id":"https://openalex.org/C134306372","wikidata":"https://www.wikidata.org/wiki/Q7754","display_name":"Mathematical analysis","level":1,"score":0.0},{"id":"https://openalex.org/C89423630","wikidata":"https://www.wikidata.org/wiki/Q7193","display_name":"Microbiology","level":1,"score":0.0},{"id":"https://openalex.org/C86803240","wikidata":"https://www.wikidata.org/wiki/Q420","display_name":"Biology","level":0,"score":0.0}],"mesh":[],"locations_count":1,"locations":[{"id":"doi:10.1109/isic.2012.6398254","is_oa":false,"landing_page_url":"https://doi.org/10.1109/isic.2012.6398254","pdf_url":null,"source":null,"license":null,"license_id":null,"version":"publishedVersion","is_accepted":true,"is_published":true,"raw_source_name":"2012 IEEE International Symposium on Intelligent Control","raw_type":"proceedings-article"}],"best_oa_location":null,"sustainable_development_goals":[],"awards":[],"funders":[],"has_content":{"grobid_xml":false,"pdf":false},"content_urls":null,"referenced_works_count":28,"referenced_works":["https://openalex.org/W177309642","https://openalex.org/W1482540049","https://openalex.org/W1510598017","https://openalex.org/W1533525061","https://openalex.org/W1654016072","https://openalex.org/W1964729920","https://openalex.org/W1984240524","https://openalex.org/W1992936633","https://openalex.org/W2002034573","https://openalex.org/W2002536935","https://openalex.org/W2005686439","https://openalex.org/W2014714997","https://openalex.org/W2020582173","https://openalex.org/W2031127020","https://openalex.org/W2074965708","https://openalex.org/W2079271849","https://openalex.org/W2092140992","https://openalex.org/W2113556584","https://openalex.org/W2117796671","https://openalex.org/W2121990262","https://openalex.org/W2132314780","https://openalex.org/W2173067334","https://openalex.org/W2322426953","https://openalex.org/W2324439968","https://openalex.org/W3146551586","https://openalex.org/W4234011532","https://openalex.org/W6658256918","https://openalex.org/W6673395905"],"related_works":["https://openalex.org/W2490690736","https://openalex.org/W2099333796","https://openalex.org/W2394779770","https://openalex.org/W1999058329","https://openalex.org/W3121254296","https://openalex.org/W2060193301","https://openalex.org/W2096333878","https://openalex.org/W2762711590","https://openalex.org/W2016812753","https://openalex.org/W4313023967"],"abstract_inverted_index":{"This":[0],"contribution":[1],"deals":[2],"with":[3],"the":[4,44,51,91],"design":[5,93],"of":[6,25,53],"fault":[7,56,61,84],"isolation":[8,62,85],"observers":[9,34,86],"(FIOs).":[10],"Their":[11],"purpose":[12],"is":[13],"to":[14,47,95],"detect":[15],"and":[16,99],"isolate":[17,96],"faults":[18],"acting":[19],"on":[20],"linear":[21,48],"systems":[22,49],"by":[23,81],"means":[24],"only":[26],"a":[27,54],"single":[28],"observer.":[29],"While":[30],"parameterizations":[31],"for":[32,38],"such":[33,64],"have":[35],"been":[36],"proposed":[37,92],"statically":[39],"isolable":[40],"systems,":[41,65],"we":[42,66],"generalize":[43],"existing":[45],"results":[46],"without":[50],"restriction":[52],"non-singular":[55],"detectability":[57],"matrix.":[58],"To":[59],"achieve":[60],"in":[63],"introduce":[67],"virtual":[68,76],"system":[69],"extensions,":[70],"which":[71],"enable":[72],"stable":[73],"isolation.":[74],"These":[75],"augmentations":[77],"are":[78],"then":[79],"realized":[80],"dynamically":[82],"extended":[83],"(DFIOs).":[87],"Apart":[88],"from":[89],"that":[90],"allows":[94],"both":[97],"actuator":[98],"sensor":[100],"faults.":[101]},"counts_by_year":[{"year":2020,"cited_by_count":1},{"year":2014,"cited_by_count":2},{"year":2013,"cited_by_count":2},{"year":2012,"cited_by_count":2}],"updated_date":"2025-11-06T03:46:38.306776","created_date":"2025-10-10T00:00:00"}