{"id":"https://openalex.org/W4407361204","doi":"https://doi.org/10.1109/isgteurope62998.2024.10863668","title":"A Fixed Point Method for the AC Power Flow Calculation","display_name":"A Fixed Point Method for the AC Power Flow Calculation","publication_year":2024,"publication_date":"2024-10-14","ids":{"openalex":"https://openalex.org/W4407361204","doi":"https://doi.org/10.1109/isgteurope62998.2024.10863668"},"language":"en","primary_location":{"id":"doi:10.1109/isgteurope62998.2024.10863668","is_oa":false,"landing_page_url":"https://doi.org/10.1109/isgteurope62998.2024.10863668","pdf_url":null,"source":null,"license":null,"license_id":null,"version":"publishedVersion","is_accepted":true,"is_published":true,"raw_source_name":"2024 IEEE PES Innovative Smart Grid Technologies Europe (ISGT EUROPE)","raw_type":"proceedings-article"},"type":"article","indexed_in":["crossref"],"open_access":{"is_oa":false,"oa_status":"closed","oa_url":null,"any_repository_has_fulltext":false},"authorships":[{"author_position":"first","author":{"id":"https://openalex.org/A5084903927","display_name":"Miguel Jim\u00e9nez Carrizosa","orcid":"https://orcid.org/0000-0002-8703-8276"},"institutions":[{"id":"https://openalex.org/I88060688","display_name":"Universidad Polit\u00e9cnica de Madrid","ror":"https://ror.org/03n6nwv02","country_code":"ES","type":"education","lineage":["https://openalex.org/I88060688"]}],"countries":["ES"],"is_corresponding":true,"raw_author_name":"Miguel Jim\u00e9nez Carrizosa","raw_affiliation_strings":["Universidad Polit&#x00E9;cnica de Madrid (UPM),Escuela T&#x00E9;cnica Superior de Ingenieros de Minas y Energ&#x00ED;a Centro de Electr&#x00F3;nica Industrial (CEI-UPM),Madrid,Spain"],"affiliations":[{"raw_affiliation_string":"Universidad Polit&#x00E9;cnica de Madrid (UPM),Escuela T&#x00E9;cnica Superior de Ingenieros de Minas y Energ&#x00ED;a Centro de Electr&#x00F3;nica Industrial (CEI-UPM),Madrid,Spain","institution_ids":["https://openalex.org/I88060688"]}]},{"author_position":"last","author":{"id":"https://openalex.org/A5036071325","display_name":"Dionysios Moutevelis","orcid":"https://orcid.org/0000-0002-3388-117X"},"institutions":[{"id":"https://openalex.org/I92621186","display_name":"Acciona (Spain)","ror":"https://ror.org/04y85wy15","country_code":"ES","type":"company","lineage":["https://openalex.org/I92621186"]},{"id":"https://openalex.org/I9617848","display_name":"Universitat Polit\u00e8cnica de Catalunya","ror":"https://ror.org/03mb6wj31","country_code":"ES","type":"education","lineage":["https://openalex.org/I9617848"]}],"countries":["ES"],"is_corresponding":false,"raw_author_name":"Dionysios Moutevelis","raw_affiliation_strings":["Centre d&#x2019;Innovaci&#x00F3; Tecn&#x00F2;lgica en Convertidors Est&#x00E0;tics i Accionaments - Universitat Polit&#x00E8;cnica de Catalunya (CITCEA-UPC),Barcelona,Spain"],"affiliations":[{"raw_affiliation_string":"Centre d&#x2019;Innovaci&#x00F3; Tecn&#x00F2;lgica en Convertidors Est&#x00E0;tics i Accionaments - Universitat Polit&#x00E8;cnica de Catalunya (CITCEA-UPC),Barcelona,Spain","institution_ids":["https://openalex.org/I9617848","https://openalex.org/I92621186"]}]}],"institutions":[],"countries_distinct_count":1,"institutions_distinct_count":2,"corresponding_author_ids":["https://openalex.org/A5084903927"],"corresponding_institution_ids":["https://openalex.org/I88060688"],"apc_list":null,"apc_paid":null,"fwci":0.0,"has_fulltext":false,"cited_by_count":0,"citation_normalized_percentile":{"value":0.25257772,"is_in_top_1_percent":false,"is_in_top_10_percent":false},"cited_by_percentile_year":null,"biblio":{"volume":null,"issue":null,"first_page":"1","last_page":"5"},"is_retracted":false,"is_paratext":false,"is_xpac":false,"primary_topic":{"id":"https://openalex.org/T10305","display_name":"Power System Optimization and Stability","score":0.9850000143051147,"subfield":{"id":"https://openalex.org/subfields/2208","display_name":"Electrical and Electronic Engineering"},"field":{"id":"https://openalex.org/fields/22","display_name":"Engineering"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}},"topics":[{"id":"https://openalex.org/T10305","display_name":"Power System Optimization and Stability","score":0.9850000143051147,"subfield":{"id":"https://openalex.org/subfields/2208","display_name":"Electrical and Electronic Engineering"},"field":{"id":"https://openalex.org/fields/22","display_name":"Engineering"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}},{"id":"https://openalex.org/T12804","display_name":"Thermal Analysis in Power Transmission","score":0.975600004196167,"subfield":{"id":"https://openalex.org/subfields/2207","display_name":"Control and Systems Engineering"},"field":{"id":"https://openalex.org/fields/22","display_name":"Engineering"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}},{"id":"https://openalex.org/T12810","display_name":"Real-time simulation and control systems","score":0.975600004196167,"subfield":{"id":"https://openalex.org/subfields/2207","display_name":"Control and Systems Engineering"},"field":{"id":"https://openalex.org/fields/22","display_name":"Engineering"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}}],"keywords":[{"id":"https://openalex.org/keywords/power-flow","display_name":"Power flow","score":0.6266028881072998},{"id":"https://openalex.org/keywords/fixed-point","display_name":"Fixed point","score":0.5694301724433899},{"id":"https://openalex.org/keywords/flow","display_name":"Flow (mathematics)","score":0.4744340479373932},{"id":"https://openalex.org/keywords/computer-science","display_name":"Computer science","score":0.46765321493148804},{"id":"https://openalex.org/keywords/power","display_name":"Power (physics)","score":0.3922354578971863},{"id":"https://openalex.org/keywords/topology","display_name":"Topology (electrical circuits)","score":0.36103689670562744},{"id":"https://openalex.org/keywords/electric-power-system","display_name":"Electric power system","score":0.31117722392082214},{"id":"https://openalex.org/keywords/mathematics","display_name":"Mathematics","score":0.29617077112197876},{"id":"https://openalex.org/keywords/electrical-engineering","display_name":"Electrical engineering","score":0.2702678442001343},{"id":"https://openalex.org/keywords/mechanics","display_name":"Mechanics","score":0.2532350420951843},{"id":"https://openalex.org/keywords/mathematical-analysis","display_name":"Mathematical analysis","score":0.22478267550468445},{"id":"https://openalex.org/keywords/physics","display_name":"Physics","score":0.22042027115821838},{"id":"https://openalex.org/keywords/engineering","display_name":"Engineering","score":0.14591458439826965}],"concepts":[{"id":"https://openalex.org/C2986056383","wikidata":"https://www.wikidata.org/wiki/Q556030","display_name":"Power flow","level":4,"score":0.6266028881072998},{"id":"https://openalex.org/C61445026","wikidata":"https://www.wikidata.org/wiki/Q217608","display_name":"Fixed point","level":2,"score":0.5694301724433899},{"id":"https://openalex.org/C38349280","wikidata":"https://www.wikidata.org/wiki/Q1434290","display_name":"Flow (mathematics)","level":2,"score":0.4744340479373932},{"id":"https://openalex.org/C41008148","wikidata":"https://www.wikidata.org/wiki/Q21198","display_name":"Computer science","level":0,"score":0.46765321493148804},{"id":"https://openalex.org/C163258240","wikidata":"https://www.wikidata.org/wiki/Q25342","display_name":"Power (physics)","level":2,"score":0.3922354578971863},{"id":"https://openalex.org/C184720557","wikidata":"https://www.wikidata.org/wiki/Q7825049","display_name":"Topology (electrical circuits)","level":2,"score":0.36103689670562744},{"id":"https://openalex.org/C89227174","wikidata":"https://www.wikidata.org/wiki/Q2388981","display_name":"Electric power system","level":3,"score":0.31117722392082214},{"id":"https://openalex.org/C33923547","wikidata":"https://www.wikidata.org/wiki/Q395","display_name":"Mathematics","level":0,"score":0.29617077112197876},{"id":"https://openalex.org/C119599485","wikidata":"https://www.wikidata.org/wiki/Q43035","display_name":"Electrical engineering","level":1,"score":0.2702678442001343},{"id":"https://openalex.org/C57879066","wikidata":"https://www.wikidata.org/wiki/Q41217","display_name":"Mechanics","level":1,"score":0.2532350420951843},{"id":"https://openalex.org/C134306372","wikidata":"https://www.wikidata.org/wiki/Q7754","display_name":"Mathematical analysis","level":1,"score":0.22478267550468445},{"id":"https://openalex.org/C121332964","wikidata":"https://www.wikidata.org/wiki/Q413","display_name":"Physics","level":0,"score":0.22042027115821838},{"id":"https://openalex.org/C127413603","wikidata":"https://www.wikidata.org/wiki/Q11023","display_name":"Engineering","level":0,"score":0.14591458439826965},{"id":"https://openalex.org/C62520636","wikidata":"https://www.wikidata.org/wiki/Q944","display_name":"Quantum mechanics","level":1,"score":0.0}],"mesh":[],"locations_count":1,"locations":[{"id":"doi:10.1109/isgteurope62998.2024.10863668","is_oa":false,"landing_page_url":"https://doi.org/10.1109/isgteurope62998.2024.10863668","pdf_url":null,"source":null,"license":null,"license_id":null,"version":"publishedVersion","is_accepted":true,"is_published":true,"raw_source_name":"2024 IEEE PES Innovative Smart Grid Technologies Europe (ISGT EUROPE)","raw_type":"proceedings-article"}],"best_oa_location":null,"sustainable_development_goals":[{"score":0.7799999713897705,"display_name":"Affordable and clean energy","id":"https://metadata.un.org/sdg/7"}],"awards":[],"funders":[],"has_content":{"pdf":false,"grobid_xml":false},"content_urls":null,"referenced_works_count":11,"referenced_works":["https://openalex.org/W1016398172","https://openalex.org/W1484104892","https://openalex.org/W1980092375","https://openalex.org/W1984452440","https://openalex.org/W2485674704","https://openalex.org/W2738518985","https://openalex.org/W4206407320","https://openalex.org/W4212821273","https://openalex.org/W4285384271","https://openalex.org/W4300548550","https://openalex.org/W4382936248"],"related_works":["https://openalex.org/W172022518","https://openalex.org/W124145845","https://openalex.org/W4293114312","https://openalex.org/W1970560677","https://openalex.org/W4362700221","https://openalex.org/W2090103360","https://openalex.org/W1700814124","https://openalex.org/W3103887953","https://openalex.org/W2404455309","https://openalex.org/W2093947781"],"abstract_inverted_index":{"This":[0],"paper":[1],"presents":[2],"an":[3],"AC":[4],"power":[5,57,83],"flow":[6,58,84],"algorithm":[7,23,47],"using":[8],"a":[9,25,75],"fixed":[10],"point":[11],"method":[12,20,79,92],"based":[13],"on":[14],"the":[15,22,28,31,52,55,56,61,81,90,100,103,109],"contractive":[16],"mapping":[17],"theorem.":[18],"The":[19,45,86],"guarantees":[21],"convergence":[24,97],"priori":[26],"and":[27,80,96],"uniqueness":[29],"of":[30,54,102],"solution,":[32],"if":[33],"it":[34],"exists,":[35],"while":[36],"requiring":[37],"less":[38],"computational":[39],"efforts":[40],"compared":[41,73,107],"to":[42,108],"classical":[43,76],"methods.":[44],"proposed":[46,91],"is":[48,72],"firstly":[49],"applied":[50],"for":[51,60],"solution":[53],"problem":[59],"IEEE":[62],"14-bus":[63],"system":[64],"under":[65],"load":[66],"stress":[67],"scenarios.":[68],"Then,":[69],"its":[70],"performance":[71],"against":[74],"Jacobian":[77,111],"matrix-based":[78],"continuation":[82],"method.":[85,114],"results":[87],"show":[88],"that":[89],"provides":[93],"better":[94],"accuracy":[95],"properties":[98],"in":[99],"vicinity":[101],"critical":[104],"voltage":[105],"point,":[106],"standard":[110],"matrix-based,":[112],"Newton-Raphson":[113]},"counts_by_year":[],"updated_date":"2025-12-19T19:40:27.379048","created_date":"2025-10-10T00:00:00"}
