{"id":"https://openalex.org/W4391342858","doi":"https://doi.org/10.1109/isgteurope56780.2023.10407763","title":"Reconfiguration Method for Low Voltage Distribution Networks","display_name":"Reconfiguration Method for Low Voltage Distribution Networks","publication_year":2023,"publication_date":"2023-10-23","ids":{"openalex":"https://openalex.org/W4391342858","doi":"https://doi.org/10.1109/isgteurope56780.2023.10407763"},"language":"en","primary_location":{"id":"doi:10.1109/isgteurope56780.2023.10407763","is_oa":false,"landing_page_url":"https://doi.org/10.1109/isgteurope56780.2023.10407763","pdf_url":null,"source":null,"license":null,"license_id":null,"version":"publishedVersion","is_accepted":true,"is_published":true,"raw_source_name":"2023 IEEE PES Innovative Smart Grid Technologies Europe (ISGT EUROPE)","raw_type":"proceedings-article"},"type":"article","indexed_in":["crossref"],"open_access":{"is_oa":false,"oa_status":"closed","oa_url":null,"any_repository_has_fulltext":false},"authorships":[{"author_position":"first","author":{"id":"https://openalex.org/A5068466747","display_name":"Sari Kerckhove","orcid":"https://orcid.org/0000-0002-0921-1010"},"institutions":[{"id":"https://openalex.org/I99464096","display_name":"KU Leuven","ror":"https://ror.org/05f950310","country_code":"BE","type":"education","lineage":["https://openalex.org/I99464096"]}],"countries":["BE"],"is_corresponding":false,"raw_author_name":"Sari Kerckhove","raw_affiliation_strings":["KU Leuven, EnergyVille, VITO,Electrical Engineering dept.,Leuven,Belgium","Electrical Engineering dept., KU Leuven, EnergyVille, VITO, Leuven, Belgium"],"raw_orcid":null,"affiliations":[{"raw_affiliation_string":"KU Leuven, EnergyVille, VITO,Electrical Engineering dept.,Leuven,Belgium","institution_ids":["https://openalex.org/I99464096"]},{"raw_affiliation_string":"Electrical Engineering dept., KU Leuven, EnergyVille, VITO, Leuven, Belgium","institution_ids":["https://openalex.org/I99464096"]}]},{"author_position":"middle","author":{"id":"https://openalex.org/A5081145804","display_name":"Reinhilde D\u2019hulst","orcid":"https://orcid.org/0000-0003-3444-6644"},"institutions":[{"id":"https://openalex.org/I2800534741","display_name":"Directorate-General for Energy","ror":"https://ror.org/04gkw9q47","country_code":"BE","type":"government","lineage":["https://openalex.org/I1320481043","https://openalex.org/I2800387288","https://openalex.org/I2800534741"]}],"countries":["BE"],"is_corresponding":false,"raw_author_name":"Reinhilde D\u2019Hulst","raw_affiliation_strings":["Energy Technology Unit EnergyVille, VITO,Genk,Belgium","Energy Technology Unit EnergyVille, VITO, Genk, Belgium"],"raw_orcid":null,"affiliations":[{"raw_affiliation_string":"Energy Technology Unit EnergyVille, VITO,Genk,Belgium","institution_ids":["https://openalex.org/I2800534741"]},{"raw_affiliation_string":"Energy Technology Unit EnergyVille, VITO, Genk, Belgium","institution_ids":["https://openalex.org/I2800534741"]}]},{"author_position":"last","author":{"id":"https://openalex.org/A5018842792","display_name":"Dirk Van Hertem","orcid":"https://orcid.org/0000-0001-5461-8891"},"institutions":[{"id":"https://openalex.org/I99464096","display_name":"KU Leuven","ror":"https://ror.org/05f950310","country_code":"BE","type":"education","lineage":["https://openalex.org/I99464096"]}],"countries":["BE"],"is_corresponding":false,"raw_author_name":"Dirk Van Hertem","raw_affiliation_strings":["KU Leuven, EnergyVille,Electrical Engineering dept.,Leuven,Belgium","Electrical Engineering dept., KU Leuven, EnergyVille, Leuven, Belgium"],"raw_orcid":null,"affiliations":[{"raw_affiliation_string":"KU Leuven, EnergyVille,Electrical Engineering dept.,Leuven,Belgium","institution_ids":["https://openalex.org/I99464096"]},{"raw_affiliation_string":"Electrical Engineering dept., KU Leuven, EnergyVille, Leuven, Belgium","institution_ids":["https://openalex.org/I99464096"]}]}],"institutions":[],"countries_distinct_count":1,"institutions_distinct_count":3,"corresponding_author_ids":[],"corresponding_institution_ids":[],"apc_list":null,"apc_paid":null,"fwci":0.6136,"has_fulltext":false,"cited_by_count":5,"citation_normalized_percentile":{"value":0.68735119,"is_in_top_1_percent":false,"is_in_top_10_percent":false},"cited_by_percentile_year":{"min":90,"max":96},"biblio":{"volume":null,"issue":null,"first_page":null,"last_page":null},"is_retracted":false,"is_paratext":false,"is_xpac":false,"primary_topic":{"id":"https://openalex.org/T10454","display_name":"Optimal Power Flow Distribution","score":0.9998999834060669,"subfield":{"id":"https://openalex.org/subfields/2208","display_name":"Electrical and Electronic Engineering"},"field":{"id":"https://openalex.org/fields/22","display_name":"Engineering"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}},"topics":[{"id":"https://openalex.org/T10454","display_name":"Optimal Power Flow Distribution","score":0.9998999834060669,"subfield":{"id":"https://openalex.org/subfields/2208","display_name":"Electrical and Electronic Engineering"},"field":{"id":"https://openalex.org/fields/22","display_name":"Engineering"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}},{"id":"https://openalex.org/T10223","display_name":"Microgrid Control and Optimization","score":0.9990000128746033,"subfield":{"id":"https://openalex.org/subfields/2207","display_name":"Control and Systems Engineering"},"field":{"id":"https://openalex.org/fields/22","display_name":"Engineering"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}},{"id":"https://openalex.org/T10603","display_name":"Smart Grid Energy Management","score":0.9854000210762024,"subfield":{"id":"https://openalex.org/subfields/2208","display_name":"Electrical and Electronic Engineering"},"field":{"id":"https://openalex.org/fields/22","display_name":"Engineering"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}}],"keywords":[{"id":"https://openalex.org/keywords/control-reconfiguration","display_name":"Control reconfiguration","score":0.9168416261672974},{"id":"https://openalex.org/keywords/computer-science","display_name":"Computer science","score":0.6407873034477234},{"id":"https://openalex.org/keywords/grid","display_name":"Grid","score":0.5375297665596008},{"id":"https://openalex.org/keywords/heuristic","display_name":"Heuristic","score":0.5228567123413086},{"id":"https://openalex.org/keywords/voltage","display_name":"Voltage","score":0.4905347228050232},{"id":"https://openalex.org/keywords/low-voltage","display_name":"Low voltage","score":0.45949414372444153},{"id":"https://openalex.org/keywords/distributed-generation","display_name":"Distributed generation","score":0.4537392854690552},{"id":"https://openalex.org/keywords/power","display_name":"Power (physics)","score":0.4181780219078064},{"id":"https://openalex.org/keywords/mathematical-optimization","display_name":"Mathematical optimization","score":0.412982314825058},{"id":"https://openalex.org/keywords/distributed-computing","display_name":"Distributed computing","score":0.4013378620147705},{"id":"https://openalex.org/keywords/topology","display_name":"Topology (electrical circuits)","score":0.3662514388561249},{"id":"https://openalex.org/keywords/reliability-engineering","display_name":"Reliability engineering","score":0.3525356352329254},{"id":"https://openalex.org/keywords/engineering","display_name":"Engineering","score":0.2171432375907898},{"id":"https://openalex.org/keywords/electrical-engineering","display_name":"Electrical engineering","score":0.1809772253036499},{"id":"https://openalex.org/keywords/embedded-system","display_name":"Embedded system","score":0.16850614547729492},{"id":"https://openalex.org/keywords/renewable-energy","display_name":"Renewable energy","score":0.14372768998146057},{"id":"https://openalex.org/keywords/mathematics","display_name":"Mathematics","score":0.10144659876823425}],"concepts":[{"id":"https://openalex.org/C119701452","wikidata":"https://www.wikidata.org/wiki/Q5165881","display_name":"Control reconfiguration","level":2,"score":0.9168416261672974},{"id":"https://openalex.org/C41008148","wikidata":"https://www.wikidata.org/wiki/Q21198","display_name":"Computer science","level":0,"score":0.6407873034477234},{"id":"https://openalex.org/C187691185","wikidata":"https://www.wikidata.org/wiki/Q2020720","display_name":"Grid","level":2,"score":0.5375297665596008},{"id":"https://openalex.org/C173801870","wikidata":"https://www.wikidata.org/wiki/Q201413","display_name":"Heuristic","level":2,"score":0.5228567123413086},{"id":"https://openalex.org/C165801399","wikidata":"https://www.wikidata.org/wiki/Q25428","display_name":"Voltage","level":2,"score":0.4905347228050232},{"id":"https://openalex.org/C128624480","wikidata":"https://www.wikidata.org/wiki/Q1504817","display_name":"Low voltage","level":3,"score":0.45949414372444153},{"id":"https://openalex.org/C544738498","wikidata":"https://www.wikidata.org/wiki/Q861135","display_name":"Distributed generation","level":3,"score":0.4537392854690552},{"id":"https://openalex.org/C163258240","wikidata":"https://www.wikidata.org/wiki/Q25342","display_name":"Power (physics)","level":2,"score":0.4181780219078064},{"id":"https://openalex.org/C126255220","wikidata":"https://www.wikidata.org/wiki/Q141495","display_name":"Mathematical optimization","level":1,"score":0.412982314825058},{"id":"https://openalex.org/C120314980","wikidata":"https://www.wikidata.org/wiki/Q180634","display_name":"Distributed computing","level":1,"score":0.4013378620147705},{"id":"https://openalex.org/C184720557","wikidata":"https://www.wikidata.org/wiki/Q7825049","display_name":"Topology (electrical circuits)","level":2,"score":0.3662514388561249},{"id":"https://openalex.org/C200601418","wikidata":"https://www.wikidata.org/wiki/Q2193887","display_name":"Reliability engineering","level":1,"score":0.3525356352329254},{"id":"https://openalex.org/C127413603","wikidata":"https://www.wikidata.org/wiki/Q11023","display_name":"Engineering","level":0,"score":0.2171432375907898},{"id":"https://openalex.org/C119599485","wikidata":"https://www.wikidata.org/wiki/Q43035","display_name":"Electrical engineering","level":1,"score":0.1809772253036499},{"id":"https://openalex.org/C149635348","wikidata":"https://www.wikidata.org/wiki/Q193040","display_name":"Embedded system","level":1,"score":0.16850614547729492},{"id":"https://openalex.org/C188573790","wikidata":"https://www.wikidata.org/wiki/Q12705","display_name":"Renewable energy","level":2,"score":0.14372768998146057},{"id":"https://openalex.org/C33923547","wikidata":"https://www.wikidata.org/wiki/Q395","display_name":"Mathematics","level":0,"score":0.10144659876823425},{"id":"https://openalex.org/C62520636","wikidata":"https://www.wikidata.org/wiki/Q944","display_name":"Quantum mechanics","level":1,"score":0.0},{"id":"https://openalex.org/C121332964","wikidata":"https://www.wikidata.org/wiki/Q413","display_name":"Physics","level":0,"score":0.0},{"id":"https://openalex.org/C2524010","wikidata":"https://www.wikidata.org/wiki/Q8087","display_name":"Geometry","level":1,"score":0.0},{"id":"https://openalex.org/C154945302","wikidata":"https://www.wikidata.org/wiki/Q11660","display_name":"Artificial intelligence","level":1,"score":0.0}],"mesh":[],"locations_count":2,"locations":[{"id":"doi:10.1109/isgteurope56780.2023.10407763","is_oa":false,"landing_page_url":"https://doi.org/10.1109/isgteurope56780.2023.10407763","pdf_url":null,"source":null,"license":null,"license_id":null,"version":"publishedVersion","is_accepted":true,"is_published":true,"raw_source_name":"2023 IEEE PES Innovative Smart Grid Technologies Europe (ISGT EUROPE)","raw_type":"proceedings-article"},{"id":"pmh:oai:lirias2repo.kuleuven.be:20.500.12942/771431","is_oa":false,"landing_page_url":"https://lirias.kuleuven.be/handle/20.500.12942/771431","pdf_url":null,"source":{"id":"https://openalex.org/S4306401954","display_name":"Lirias (KU Leuven)","issn_l":null,"issn":null,"is_oa":false,"is_in_doaj":false,"is_core":false,"host_organization":"https://openalex.org/I99464096","host_organization_name":"KU Leuven","host_organization_lineage":["https://openalex.org/I99464096"],"host_organization_lineage_names":[],"type":"repository"},"license":null,"license_id":null,"version":"submittedVersion","is_accepted":false,"is_published":false,"raw_source_name":"2023 IEEE PES Innovative Smart Grid Technologies Europe (ISGT EUROPE), Grenoble, France","raw_type":"info:eu-repo/semantics/publishedVersion"}],"best_oa_location":null,"sustainable_development_goals":[{"score":0.7300000190734863,"id":"https://metadata.un.org/sdg/7","display_name":"Affordable and clean energy"}],"awards":[],"funders":[],"has_content":{"pdf":false,"grobid_xml":false},"content_urls":null,"referenced_works_count":13,"referenced_works":["https://openalex.org/W1975075148","https://openalex.org/W2015140184","https://openalex.org/W2043630738","https://openalex.org/W2124767421","https://openalex.org/W2146943217","https://openalex.org/W2345310144","https://openalex.org/W2800642441","https://openalex.org/W2802014092","https://openalex.org/W2803573880","https://openalex.org/W2994666729","https://openalex.org/W3195842960","https://openalex.org/W4241079583","https://openalex.org/W4288059668"],"related_works":["https://openalex.org/W2357657342","https://openalex.org/W2153432761","https://openalex.org/W2152623100","https://openalex.org/W2142042635","https://openalex.org/W4214878056","https://openalex.org/W1580144672","https://openalex.org/W1988127757","https://openalex.org/W4248634784","https://openalex.org/W2103296973","https://openalex.org/W2165832238"],"abstract_inverted_index":{"Increasing":[0],"electrification":[1],"of":[2,10,115,175],"transportation":[3],"and":[4,7,24,85,93,130,137],"heating/cooling":[5],"systems,":[6],"increasing":[8],"installation":[9],"distributed":[11],"energy":[12],"resources,":[13],"strain":[14],"the":[15,21,49,65,96,112,120,125,159,164,173],"electricity":[16],"distribution":[17,27,45,61,72],"networks.":[18],"To":[19],"limit":[20],"necessary":[22],"investment-":[23],"operational":[25],"costs,":[26],"system":[28],"operators":[29],"benefit":[30],"from":[31,77],"optimally":[32],"using":[33,132],"their":[34],"existing":[35],"grid":[36,179],"infrastructure.":[37],"One":[38],"important":[39],"strategy":[40],"to":[41,111,118,135],"achieve":[42],"this,":[43],"is":[44],"network":[46],"reconfiguration.":[47],"In":[48],"past,":[50],"reconfiguration":[51,106,151,182],"methods":[52,67,107],"have":[53,82],"mostly":[54],"been":[55],"developed":[56],"for":[57,147],"medium":[58],"voltage":[59,70,161],"(MV)":[60],"grids.":[62],"Directly":[63],"applying":[64],"same":[66],"on":[68],"low":[69,160],"(LV)":[71],"grids,":[73],"which":[74,104,153],"structurally":[75],"differ":[76],"MV":[78],"grids":[79,117],"as":[80],"they":[81],"more":[83],"feeders":[84],"are":[86,145],"less":[87],"meshed,":[88],"ignores":[89],"these":[90],"structural":[91,113],"differences,":[92],"therefore":[94],"reduces":[95],"methods\u2019":[97],"effectiveness.This":[98],"paper":[99],"proposes":[100],"two":[101],"ways":[102],"in":[103,181],"heuristic":[105,150],"can":[108],"be":[109],"adapted":[110],"properties":[114,180],"LV":[116,177],"reduce":[119],"solution":[121],"time:":[122],"(1(":[123],"decomposing":[124],"problem":[126],"into":[127],"independent":[128],"subproblems,":[129],"(2)":[131],"a":[133,148],"cache":[134],"store":[136],"reuse":[138],"summarized":[139],"power":[140],"flow":[141],"results.":[142],"The":[143],"improvements":[144],"demonstrated":[146],"loss-minimizing":[149],"method":[152],"also":[154],"limits":[155],"congestion":[156],"risks.":[157],"For":[158],"test":[162],"network,":[163],"computational":[165],"time":[166],"was":[167],"reduced":[168],"by":[169],"96%,":[170],"clearly":[171],"illustrating":[172],"advantage":[174],"exploiting":[176],"specific":[178],"algorithms.":[183]},"counts_by_year":[{"year":2025,"cited_by_count":2},{"year":2024,"cited_by_count":2},{"year":2023,"cited_by_count":1}],"updated_date":"2026-06-11T09:08:48.828518","created_date":"2025-10-10T00:00:00"}