{"id":"https://openalex.org/W4200005472","doi":"https://doi.org/10.1109/isgteurope52324.2021.9640178","title":"Real-time testing of out-of-step protection devices","display_name":"Real-time testing of out-of-step protection devices","publication_year":2021,"publication_date":"2021-10-18","ids":{"openalex":"https://openalex.org/W4200005472","doi":"https://doi.org/10.1109/isgteurope52324.2021.9640178"},"language":"en","primary_location":{"id":"doi:10.1109/isgteurope52324.2021.9640178","is_oa":false,"landing_page_url":"https://doi.org/10.1109/isgteurope52324.2021.9640178","pdf_url":null,"source":{"id":"https://openalex.org/S4363605480","display_name":"2021 IEEE PES Innovative Smart Grid Technologies Europe (ISGT Europe)","issn_l":null,"issn":null,"is_oa":false,"is_in_doaj":false,"is_core":false,"host_organization":null,"host_organization_name":null,"host_organization_lineage":[],"host_organization_lineage_names":[],"type":"conference"},"license":null,"license_id":null,"version":"publishedVersion","is_accepted":true,"is_published":true,"raw_source_name":"2021 IEEE PES Innovative Smart Grid Technologies Europe (ISGT Europe)","raw_type":"proceedings-article"},"type":"article","indexed_in":["crossref"],"open_access":{"is_oa":false,"oa_status":"closed","oa_url":null,"any_repository_has_fulltext":false},"authorships":[{"author_position":"first","author":{"id":"https://openalex.org/A5055684302","display_name":"Marko Tealane","orcid":"https://orcid.org/0000-0002-5419-9276"},"institutions":[{"id":"https://openalex.org/I111112146","display_name":"Tallinn University of Technology","ror":"https://ror.org/0443cwa12","country_code":"EE","type":"education","lineage":["https://openalex.org/I111112146"]}],"countries":["EE"],"is_corresponding":true,"raw_author_name":"Marko Tealane","raw_affiliation_strings":["Tallinn University of Technology, Tallinn, Estonia"],"affiliations":[{"raw_affiliation_string":"Tallinn University of Technology, Tallinn, Estonia","institution_ids":["https://openalex.org/I111112146"]}]},{"author_position":"middle","author":{"id":"https://openalex.org/A5049364962","display_name":"Jako Kilter","orcid":"https://orcid.org/0000-0003-4985-857X"},"institutions":[{"id":"https://openalex.org/I111112146","display_name":"Tallinn University of Technology","ror":"https://ror.org/0443cwa12","country_code":"EE","type":"education","lineage":["https://openalex.org/I111112146"]}],"countries":["EE"],"is_corresponding":false,"raw_author_name":"Jako Kilter","raw_affiliation_strings":["Tallinn University of Technology, Tallinn, Estonia"],"affiliations":[{"raw_affiliation_string":"Tallinn University of Technology, Tallinn, Estonia","institution_ids":["https://openalex.org/I111112146"]}]},{"author_position":"last","author":{"id":"https://openalex.org/A5021639982","display_name":"Kristen Pill","orcid":null},"institutions":[],"countries":[],"is_corresponding":false,"raw_author_name":"Kristen Pill","raw_affiliation_strings":["Energy System Control Centre Elering AS, Tallinn, Estonia"],"affiliations":[{"raw_affiliation_string":"Energy System Control Centre Elering AS, Tallinn, Estonia","institution_ids":[]}]}],"institutions":[],"countries_distinct_count":1,"institutions_distinct_count":3,"corresponding_author_ids":["https://openalex.org/A5055684302"],"corresponding_institution_ids":["https://openalex.org/I111112146"],"apc_list":null,"apc_paid":null,"fwci":0.4363,"has_fulltext":false,"cited_by_count":1,"citation_normalized_percentile":{"value":0.46458527,"is_in_top_1_percent":false,"is_in_top_10_percent":false},"cited_by_percentile_year":{"min":89,"max":94},"biblio":{"volume":"1","issue":null,"first_page":"1","last_page":"5"},"is_retracted":false,"is_paratext":false,"is_xpac":false,"primary_topic":{"id":"https://openalex.org/T10972","display_name":"Power Systems Fault Detection","score":0.9997000098228455,"subfield":{"id":"https://openalex.org/subfields/2207","display_name":"Control and Systems Engineering"},"field":{"id":"https://openalex.org/fields/22","display_name":"Engineering"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}},"topics":[{"id":"https://openalex.org/T10972","display_name":"Power Systems Fault Detection","score":0.9997000098228455,"subfield":{"id":"https://openalex.org/subfields/2207","display_name":"Control and Systems Engineering"},"field":{"id":"https://openalex.org/fields/22","display_name":"Engineering"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}},{"id":"https://openalex.org/T10305","display_name":"Power System Optimization and Stability","score":0.9995999932289124,"subfield":{"id":"https://openalex.org/subfields/2208","display_name":"Electrical and Electronic Engineering"},"field":{"id":"https://openalex.org/fields/22","display_name":"Engineering"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}},{"id":"https://openalex.org/T11102","display_name":"HVDC Systems and Fault Protection","score":0.9991000294685364,"subfield":{"id":"https://openalex.org/subfields/2208","display_name":"Electrical and Electronic Engineering"},"field":{"id":"https://openalex.org/fields/22","display_name":"Engineering"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}}],"keywords":[{"id":"https://openalex.org/keywords/electric-power-system","display_name":"Electric power system","score":0.7055855393409729},{"id":"https://openalex.org/keywords/computer-science","display_name":"Computer science","score":0.6452534794807434},{"id":"https://openalex.org/keywords/reliability-engineering","display_name":"Reliability engineering","score":0.5903908610343933},{"id":"https://openalex.org/keywords/grid","display_name":"Grid","score":0.5164973139762878},{"id":"https://openalex.org/keywords/power-grid","display_name":"Power grid","score":0.4884447157382965},{"id":"https://openalex.org/keywords/power-network","display_name":"Power network","score":0.48821333050727844},{"id":"https://openalex.org/keywords/transmission-line","display_name":"Transmission line","score":0.4767128825187683},{"id":"https://openalex.org/keywords/power-system-protection","display_name":"Power-system protection","score":0.45483678579330444},{"id":"https://openalex.org/keywords/protective-relay","display_name":"Protective relay","score":0.45312172174453735},{"id":"https://openalex.org/keywords/power","display_name":"Power (physics)","score":0.4492166042327881},{"id":"https://openalex.org/keywords/transmission-system","display_name":"Transmission system","score":0.4119589328765869},{"id":"https://openalex.org/keywords/transmission","display_name":"Transmission (telecommunications)","score":0.4007289707660675},{"id":"https://openalex.org/keywords/real-time-computing","display_name":"Real-time computing","score":0.3494349718093872},{"id":"https://openalex.org/keywords/engineering","display_name":"Engineering","score":0.2770204544067383},{"id":"https://openalex.org/keywords/telecommunications","display_name":"Telecommunications","score":0.14349016547203064}],"concepts":[{"id":"https://openalex.org/C89227174","wikidata":"https://www.wikidata.org/wiki/Q2388981","display_name":"Electric power system","level":3,"score":0.7055855393409729},{"id":"https://openalex.org/C41008148","wikidata":"https://www.wikidata.org/wiki/Q21198","display_name":"Computer science","level":0,"score":0.6452534794807434},{"id":"https://openalex.org/C200601418","wikidata":"https://www.wikidata.org/wiki/Q2193887","display_name":"Reliability engineering","level":1,"score":0.5903908610343933},{"id":"https://openalex.org/C187691185","wikidata":"https://www.wikidata.org/wiki/Q2020720","display_name":"Grid","level":2,"score":0.5164973139762878},{"id":"https://openalex.org/C2983254600","wikidata":"https://www.wikidata.org/wiki/Q1096907","display_name":"Power grid","level":3,"score":0.4884447157382965},{"id":"https://openalex.org/C2989126829","wikidata":"https://www.wikidata.org/wiki/Q2388981","display_name":"Power network","level":4,"score":0.48821333050727844},{"id":"https://openalex.org/C33441834","wikidata":"https://www.wikidata.org/wiki/Q693004","display_name":"Transmission line","level":2,"score":0.4767128825187683},{"id":"https://openalex.org/C38361682","wikidata":"https://www.wikidata.org/wiki/Q1756067","display_name":"Power-system protection","level":4,"score":0.45483678579330444},{"id":"https://openalex.org/C2412688","wikidata":"https://www.wikidata.org/wiki/Q503732","display_name":"Protective relay","level":4,"score":0.45312172174453735},{"id":"https://openalex.org/C163258240","wikidata":"https://www.wikidata.org/wiki/Q25342","display_name":"Power (physics)","level":2,"score":0.4492166042327881},{"id":"https://openalex.org/C113608303","wikidata":"https://www.wikidata.org/wiki/Q1056835","display_name":"Transmission system","level":3,"score":0.4119589328765869},{"id":"https://openalex.org/C761482","wikidata":"https://www.wikidata.org/wiki/Q118093","display_name":"Transmission (telecommunications)","level":2,"score":0.4007289707660675},{"id":"https://openalex.org/C79403827","wikidata":"https://www.wikidata.org/wiki/Q3988","display_name":"Real-time computing","level":1,"score":0.3494349718093872},{"id":"https://openalex.org/C127413603","wikidata":"https://www.wikidata.org/wiki/Q11023","display_name":"Engineering","level":0,"score":0.2770204544067383},{"id":"https://openalex.org/C76155785","wikidata":"https://www.wikidata.org/wiki/Q418","display_name":"Telecommunications","level":1,"score":0.14349016547203064},{"id":"https://openalex.org/C2524010","wikidata":"https://www.wikidata.org/wiki/Q8087","display_name":"Geometry","level":1,"score":0.0},{"id":"https://openalex.org/C121332964","wikidata":"https://www.wikidata.org/wiki/Q413","display_name":"Physics","level":0,"score":0.0},{"id":"https://openalex.org/C33923547","wikidata":"https://www.wikidata.org/wiki/Q395","display_name":"Mathematics","level":0,"score":0.0},{"id":"https://openalex.org/C62520636","wikidata":"https://www.wikidata.org/wiki/Q944","display_name":"Quantum mechanics","level":1,"score":0.0}],"mesh":[],"locations_count":1,"locations":[{"id":"doi:10.1109/isgteurope52324.2021.9640178","is_oa":false,"landing_page_url":"https://doi.org/10.1109/isgteurope52324.2021.9640178","pdf_url":null,"source":{"id":"https://openalex.org/S4363605480","display_name":"2021 IEEE PES Innovative Smart Grid Technologies Europe (ISGT Europe)","issn_l":null,"issn":null,"is_oa":false,"is_in_doaj":false,"is_core":false,"host_organization":null,"host_organization_name":null,"host_organization_lineage":[],"host_organization_lineage_names":[],"type":"conference"},"license":null,"license_id":null,"version":"publishedVersion","is_accepted":true,"is_published":true,"raw_source_name":"2021 IEEE PES Innovative Smart Grid Technologies Europe (ISGT Europe)","raw_type":"proceedings-article"}],"best_oa_location":null,"sustainable_development_goals":[{"display_name":"Affordable and clean energy","id":"https://metadata.un.org/sdg/7","score":0.8600000143051147}],"awards":[],"funders":[],"has_content":{"pdf":false,"grobid_xml":false},"content_urls":null,"referenced_works_count":9,"referenced_works":["https://openalex.org/W331415589","https://openalex.org/W1763243278","https://openalex.org/W1993218568","https://openalex.org/W2025060080","https://openalex.org/W2093063928","https://openalex.org/W2119458669","https://openalex.org/W2140317750","https://openalex.org/W2160222320","https://openalex.org/W2282196176"],"related_works":["https://openalex.org/W2363176919","https://openalex.org/W2385742051","https://openalex.org/W2387911390","https://openalex.org/W2378980158","https://openalex.org/W2377889200","https://openalex.org/W2382989357","https://openalex.org/W2096076908","https://openalex.org/W2542276659","https://openalex.org/W2351185368","https://openalex.org/W2981570070"],"abstract_inverted_index":{"In":[0,23],"future":[1,111],"power":[2,7,18],"systems":[3],"the":[4,26,39,47,78,84],"share":[5],"of":[6,28],"electronic":[8],"interfaced":[9],"generation":[10,61],"will":[11,21],"increase":[12],"and":[13,41,60,65,108],"respective":[14],"challenges":[15],"related":[16],"to":[17],"system":[19,56,86,101,106],"protection":[20,31,109],"emerge.":[22],"this":[24,94],"paper":[25],"performance":[27,48,75],"different":[29],"out-of-step":[30],"algorithms":[32,79],"is":[33,96],"assessed":[34],"using":[35],"actual":[36],"relays":[37],"from":[38,93],"network":[40],"real-time":[42],"digital":[43],"simulator":[44],"RTDS.":[45],"For":[46],"analysis":[49,82,95],"various":[50],"grid":[51],"conditions":[52],"were":[53],"considered,":[54],"e.g.":[55],"strength,":[57],"line":[58],"lengths":[59],"mix":[62],"between":[63,77],"renewables":[64],"conventional":[66],"synchronous":[67],"units.":[68],"The":[69],"results":[70],"indicate":[71],"that":[72],"there":[73],"are":[74],"differences":[76],"(relays),":[80],"therefore,":[81],"considering":[83],"specific":[85],"characteristics":[87],"should":[88],"be":[89],"made.":[90],"Information":[91],"obtained":[92],"essential":[97],"input":[98],"for":[99,110],"transmission":[100],"operators":[102],"when":[103],"planning":[104],"their":[105],"operation":[107],"networks.":[112]},"counts_by_year":[{"year":2022,"cited_by_count":1}],"updated_date":"2025-11-06T03:46:38.306776","created_date":"2025-10-10T00:00:00"}
