{"id":"https://openalex.org/W2989942488","doi":"https://doi.org/10.1109/isgteurope.2019.8905757","title":"Harmonics Content and Voltage Signal Based Hybrid Backup Scheme for Protection of Microgrid Under Different Contingencies","display_name":"Harmonics Content and Voltage Signal Based Hybrid Backup Scheme for Protection of Microgrid Under Different Contingencies","publication_year":2019,"publication_date":"2019-09-01","ids":{"openalex":"https://openalex.org/W2989942488","doi":"https://doi.org/10.1109/isgteurope.2019.8905757","mag":"2989942488"},"language":"en","primary_location":{"id":"doi:10.1109/isgteurope.2019.8905757","is_oa":false,"landing_page_url":"https://doi.org/10.1109/isgteurope.2019.8905757","pdf_url":null,"source":null,"license":null,"license_id":null,"version":"publishedVersion","is_accepted":true,"is_published":true,"raw_source_name":"2019 IEEE PES Innovative Smart Grid Technologies Europe (ISGT-Europe)","raw_type":"proceedings-article"},"type":"conference-paper","indexed_in":["crossref"],"open_access":{"is_oa":false,"oa_status":"closed","oa_url":null,"any_repository_has_fulltext":false},"authorships":[{"author_position":"first","author":{"id":"https://openalex.org/A5003024103","display_name":"Matin Jamaliyan Daryani","orcid":null},"institutions":[{"id":"https://openalex.org/I48912391","display_name":"Istanbul Technical University","ror":"https://ror.org/059636586","country_code":"TR","type":"education","lineage":["https://openalex.org/I48912391"]}],"countries":["TR"],"is_corresponding":false,"raw_author_name":"Matin Jamaliyan Daryani","raw_affiliation_strings":["Istanbul Technical University,Dep. of Electrical engineering,Istanbul,Turkey","Dep. of Electrical engineering, Istanbul Technical University, Istanbul, Turkey"],"raw_orcid":null,"affiliations":[{"raw_affiliation_string":"Istanbul Technical University,Dep. of Electrical engineering,Istanbul,Turkey","institution_ids":["https://openalex.org/I48912391"]},{"raw_affiliation_string":"Dep. of Electrical engineering, Istanbul Technical University, Istanbul, Turkey","institution_ids":["https://openalex.org/I48912391"]}]},{"author_position":"middle","author":{"id":"https://openalex.org/A5070279922","display_name":"Alireza Esmaeili Karkevandi","orcid":null},"institutions":[{"id":"https://openalex.org/I1516879","display_name":"Tarbiat Modares University","ror":"https://ror.org/03mwgfy56","country_code":"IR","type":"education","lineage":["https://openalex.org/I1516879"]}],"countries":["IR"],"is_corresponding":false,"raw_author_name":"Alireza Esmaeili Karkevandi","raw_affiliation_strings":["Tarbiat Modares University,Dep. of Electrical engineering,Tehran,Iran","Dep. of Electrical engineering, Tarbiat Modares University, Tehran, Iran"],"raw_orcid":null,"affiliations":[{"raw_affiliation_string":"Tarbiat Modares University,Dep. of Electrical engineering,Tehran,Iran","institution_ids":["https://openalex.org/I1516879"]},{"raw_affiliation_string":"Dep. of Electrical engineering, Tarbiat Modares University, Tehran, Iran","institution_ids":["https://openalex.org/I1516879"]}]},{"author_position":"last","author":{"id":"https://openalex.org/A5050334732","display_name":"\u00d6mer Usta","orcid":"https://orcid.org/0000-0003-0800-6872"},"institutions":[{"id":"https://openalex.org/I48912391","display_name":"Istanbul Technical University","ror":"https://ror.org/059636586","country_code":"TR","type":"education","lineage":["https://openalex.org/I48912391"]}],"countries":["TR"],"is_corresponding":false,"raw_author_name":"Omer Usta","raw_affiliation_strings":["Istanbul Technical University,Dep. of Electrical engineering,Istanbul,Turkey","Dep. of Electrical engineering, Istanbul Technical University, Istanbul, Turkey"],"raw_orcid":null,"affiliations":[{"raw_affiliation_string":"Istanbul Technical University,Dep. of Electrical engineering,Istanbul,Turkey","institution_ids":["https://openalex.org/I48912391"]},{"raw_affiliation_string":"Dep. of Electrical engineering, Istanbul Technical University, Istanbul, Turkey","institution_ids":["https://openalex.org/I48912391"]}]}],"institutions":[],"countries_distinct_count":2,"institutions_distinct_count":2,"corresponding_author_ids":[],"corresponding_institution_ids":[],"apc_list":null,"apc_paid":null,"fwci":1.1947,"has_fulltext":false,"cited_by_count":4,"citation_normalized_percentile":{"value":0.76301518,"is_in_top_1_percent":false,"is_in_top_10_percent":false},"cited_by_percentile_year":{"min":89,"max":94},"biblio":{"volume":null,"issue":null,"first_page":"1","last_page":"5"},"is_retracted":false,"is_paratext":false,"is_xpac":false,"primary_topic":{"id":"https://openalex.org/T13183","display_name":"Islanding Detection in Power Systems","score":1.0,"subfield":{"id":"https://openalex.org/subfields/2208","display_name":"Electrical and Electronic Engineering"},"field":{"id":"https://openalex.org/fields/22","display_name":"Engineering"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}},"topics":[{"id":"https://openalex.org/T13183","display_name":"Islanding Detection in Power Systems","score":1.0,"subfield":{"id":"https://openalex.org/subfields/2208","display_name":"Electrical and Electronic Engineering"},"field":{"id":"https://openalex.org/fields/22","display_name":"Engineering"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}},{"id":"https://openalex.org/T10972","display_name":"Power Systems Fault Detection","score":0.9997000098228455,"subfield":{"id":"https://openalex.org/subfields/2207","display_name":"Control and Systems Engineering"},"field":{"id":"https://openalex.org/fields/22","display_name":"Engineering"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}},{"id":"https://openalex.org/T10223","display_name":"Microgrid Control and Optimization","score":0.9894000291824341,"subfield":{"id":"https://openalex.org/subfields/2207","display_name":"Control and Systems Engineering"},"field":{"id":"https://openalex.org/fields/22","display_name":"Engineering"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}}],"keywords":[{"id":"https://openalex.org/keywords/microgrid","display_name":"Microgrid","score":0.9037419557571411},{"id":"https://openalex.org/keywords/backup","display_name":"Backup","score":0.8583396077156067},{"id":"https://openalex.org/keywords/overcurrent","display_name":"Overcurrent","score":0.7231987714767456},{"id":"https://openalex.org/keywords/computer-science","display_name":"Computer science","score":0.5858485102653503},{"id":"https://openalex.org/keywords/tripping","display_name":"Tripping","score":0.5832422971725464},{"id":"https://openalex.org/keywords/reliability","display_name":"Reliability (semiconductor)","score":0.5830916166305542},{"id":"https://openalex.org/keywords/reliability-engineering","display_name":"Reliability engineering","score":0.5403826832771301},{"id":"https://openalex.org/keywords/power-system-protection","display_name":"Power-system protection","score":0.5191171169281006},{"id":"https://openalex.org/keywords/total-harmonic-distortion","display_name":"Total harmonic distortion","score":0.4582890272140503},{"id":"https://openalex.org/keywords/electric-power-system","display_name":"Electric power system","score":0.40040498971939087},{"id":"https://openalex.org/keywords/voltage","display_name":"Voltage","score":0.3833344578742981},{"id":"https://openalex.org/keywords/electronic-engineering","display_name":"Electronic engineering","score":0.35128915309906006},{"id":"https://openalex.org/keywords/circuit-breaker","display_name":"Circuit breaker","score":0.30901169776916504},{"id":"https://openalex.org/keywords/power","display_name":"Power (physics)","score":0.3005577027797699},{"id":"https://openalex.org/keywords/engineering","display_name":"Engineering","score":0.29464054107666016},{"id":"https://openalex.org/keywords/electrical-engineering","display_name":"Electrical engineering","score":0.1850079894065857}],"concepts":[{"id":"https://openalex.org/C2776784348","wikidata":"https://www.wikidata.org/wiki/Q5762595","display_name":"Microgrid","level":3,"score":0.9037419557571411},{"id":"https://openalex.org/C2780945871","wikidata":"https://www.wikidata.org/wiki/Q194274","display_name":"Backup","level":2,"score":0.8583396077156067},{"id":"https://openalex.org/C47949032","wikidata":"https://www.wikidata.org/wiki/Q663542","display_name":"Overcurrent","level":3,"score":0.7231987714767456},{"id":"https://openalex.org/C41008148","wikidata":"https://www.wikidata.org/wiki/Q21198","display_name":"Computer science","level":0,"score":0.5858485102653503},{"id":"https://openalex.org/C2779733308","wikidata":"https://www.wikidata.org/wiki/Q17146464","display_name":"Tripping","level":3,"score":0.5832422971725464},{"id":"https://openalex.org/C43214815","wikidata":"https://www.wikidata.org/wiki/Q7310987","display_name":"Reliability (semiconductor)","level":3,"score":0.5830916166305542},{"id":"https://openalex.org/C200601418","wikidata":"https://www.wikidata.org/wiki/Q2193887","display_name":"Reliability engineering","level":1,"score":0.5403826832771301},{"id":"https://openalex.org/C38361682","wikidata":"https://www.wikidata.org/wiki/Q1756067","display_name":"Power-system protection","level":4,"score":0.5191171169281006},{"id":"https://openalex.org/C42156128","wikidata":"https://www.wikidata.org/wiki/Q162641","display_name":"Total harmonic distortion","level":3,"score":0.4582890272140503},{"id":"https://openalex.org/C89227174","wikidata":"https://www.wikidata.org/wiki/Q2388981","display_name":"Electric power system","level":3,"score":0.40040498971939087},{"id":"https://openalex.org/C165801399","wikidata":"https://www.wikidata.org/wiki/Q25428","display_name":"Voltage","level":2,"score":0.3833344578742981},{"id":"https://openalex.org/C24326235","wikidata":"https://www.wikidata.org/wiki/Q126095","display_name":"Electronic engineering","level":1,"score":0.35128915309906006},{"id":"https://openalex.org/C61352017","wikidata":"https://www.wikidata.org/wiki/Q211058","display_name":"Circuit breaker","level":2,"score":0.30901169776916504},{"id":"https://openalex.org/C163258240","wikidata":"https://www.wikidata.org/wiki/Q25342","display_name":"Power (physics)","level":2,"score":0.3005577027797699},{"id":"https://openalex.org/C127413603","wikidata":"https://www.wikidata.org/wiki/Q11023","display_name":"Engineering","level":0,"score":0.29464054107666016},{"id":"https://openalex.org/C119599485","wikidata":"https://www.wikidata.org/wiki/Q43035","display_name":"Electrical engineering","level":1,"score":0.1850079894065857},{"id":"https://openalex.org/C62520636","wikidata":"https://www.wikidata.org/wiki/Q944","display_name":"Quantum mechanics","level":1,"score":0.0},{"id":"https://openalex.org/C77088390","wikidata":"https://www.wikidata.org/wiki/Q8513","display_name":"Database","level":1,"score":0.0},{"id":"https://openalex.org/C121332964","wikidata":"https://www.wikidata.org/wiki/Q413","display_name":"Physics","level":0,"score":0.0}],"mesh":[],"locations_count":2,"locations":[{"id":"doi:10.1109/isgteurope.2019.8905757","is_oa":false,"landing_page_url":"https://doi.org/10.1109/isgteurope.2019.8905757","pdf_url":null,"source":null,"license":null,"license_id":null,"version":"publishedVersion","is_accepted":true,"is_published":true,"raw_source_name":"2019 IEEE PES Innovative Smart Grid Technologies Europe (ISGT-Europe)","raw_type":"proceedings-article"},{"id":"pmh:oai:polen.itu.edu.tr:11527/43611","is_oa":false,"landing_page_url":"https://hdl.handle.net/11527/43611","pdf_url":null,"source":{"id":"https://openalex.org/S4306400460","display_name":"Istanbul Technical University Academic Open Archive (Istanbul Technical University)","issn_l":null,"issn":null,"is_oa":false,"is_in_doaj":false,"is_core":false,"host_organization":"https://openalex.org/I48912391","host_organization_name":"Istanbul Technical University","host_organization_lineage":["https://openalex.org/I48912391"],"host_organization_lineage_names":[],"type":"repository"},"license":null,"license_id":null,"version":"submittedVersion","is_accepted":false,"is_published":false,"raw_source_name":null,"raw_type":"Article"}],"best_oa_location":null,"sustainable_development_goals":[],"awards":[],"funders":[],"has_content":{"pdf":false,"grobid_xml":false},"content_urls":null,"referenced_works_count":13,"referenced_works":["https://openalex.org/W1966092317","https://openalex.org/W2041934566","https://openalex.org/W2132499494","https://openalex.org/W2140462580","https://openalex.org/W2145721163","https://openalex.org/W2155891432","https://openalex.org/W2320970856","https://openalex.org/W2433145132","https://openalex.org/W2740085469","https://openalex.org/W2770421461","https://openalex.org/W2787447377","https://openalex.org/W2900672682","https://openalex.org/W6718042475"],"related_works":["https://openalex.org/W2548362380","https://openalex.org/W1965197903","https://openalex.org/W2376919679","https://openalex.org/W2168485142","https://openalex.org/W2100398797","https://openalex.org/W2360825494","https://openalex.org/W2103092243","https://openalex.org/W2143347644","https://openalex.org/W2391612739","https://openalex.org/W2075328848"],"abstract_inverted_index":{"The":[0,67,127],"concept":[1],"of":[2,12,23,33,41,43,62,65,89,95,107,129,144,160],"adaptive":[3,24,49,68],"protection":[4,14,25,34,50,63,88],"has":[5],"been":[6],"applied":[7],"to":[8,57,103],"solve":[9],"the":[10,21,44,90,93,98,105,108,130,136],"problems":[11],"conventional":[13],"approaches":[15],"for":[16,141],"microgrid.":[17,66,161],"However,":[18],"even":[19],"in":[20,54,92,97],"case":[22,94],"system":[26,64,110,133,137],"implementation,":[27],"many":[28],"factors":[29],"can":[30,138],"cause":[31],"malfunction":[32],"and":[35,60,146,157],"there":[36],"is":[37,52,74,124,134],"always":[38],"a":[39,78],"possibility":[40],"failure":[42,96],"communication":[45,113,147],"system.":[46],"A":[47],"hybrid":[48,132],"strategy":[51,70],"proposed":[53,109,131],"this":[55],"work":[56],"enhance":[58,104],"selectivity":[59],"reliability":[61,106],"overcurrent":[69],"as":[71],"primary":[72,99],"scheme":[73],"backed":[75],"up":[76,118],"by":[77,154],"Total":[79],"Harmonic":[80],"Distortion":[81],"(THD)":[82],"detection":[83],"method":[84],"that":[85,135],"takes":[86],"over":[87],"network":[91],"method.":[100],"In":[101],"order":[102],"during":[111],"possible":[112],"losses,":[114],"additional":[115],"non-communication":[116],"back":[117],"algorithm":[119],"based":[120],"on":[121],"voltage":[122],"measurement":[123],"developed,":[125],"too.":[126],"advantage":[128],"operate":[139],"correctly":[140],"all":[142],"types":[143],"internal":[145],"failures,":[148],"plus":[149],"prevents":[150],"unwanted":[151],"tripping":[152],"caused":[153],"DG":[155],"integration":[156],"dynamic":[158],"behavior":[159]},"counts_by_year":[{"year":2023,"cited_by_count":1},{"year":2022,"cited_by_count":1},{"year":2021,"cited_by_count":1},{"year":2020,"cited_by_count":1}],"updated_date":"2026-07-29T14:22:42.915294","created_date":"2025-10-10T00:00:00"}
