{"id":"https://openalex.org/W2990203768","doi":"https://doi.org/10.1109/isgteurope.2019.8905638","title":"Evolution of Distribution Underground Monitoring","display_name":"Evolution of Distribution Underground Monitoring","publication_year":2019,"publication_date":"2019-09-01","ids":{"openalex":"https://openalex.org/W2990203768","doi":"https://doi.org/10.1109/isgteurope.2019.8905638","mag":"2990203768"},"language":"en","primary_location":{"id":"doi:10.1109/isgteurope.2019.8905638","is_oa":false,"landing_page_url":"https://doi.org/10.1109/isgteurope.2019.8905638","pdf_url":null,"source":null,"license":null,"license_id":null,"version":"publishedVersion","is_accepted":true,"is_published":true,"raw_source_name":"2019 IEEE PES Innovative Smart Grid Technologies Europe (ISGT-Europe)","raw_type":"proceedings-article"},"type":"article","indexed_in":["crossref"],"open_access":{"is_oa":false,"oa_status":"closed","oa_url":null,"any_repository_has_fulltext":false},"authorships":[{"author_position":"first","author":{"id":"https://openalex.org/A5081572659","display_name":"Francisc Zavoda","orcid":null},"institutions":[{"id":"https://openalex.org/I47099075","display_name":"Hydro-Qu\u00e9bec","ror":"https://ror.org/01nhzsw25","country_code":"CA","type":"government","lineage":["https://openalex.org/I47099075"]}],"countries":["CA"],"is_corresponding":true,"raw_author_name":"Francisc Zavoda","raw_affiliation_strings":["IREQ (Hydro-Quebec),Equipment performance &#x0026; sustainability,Montreal,QC,Canada","Equipment performance & sustainability, IREQ (Hydro-Quebec), Montreal, QC, Canada"],"affiliations":[{"raw_affiliation_string":"IREQ (Hydro-Quebec),Equipment performance &#x0026; sustainability,Montreal,QC,Canada","institution_ids":["https://openalex.org/I47099075"]},{"raw_affiliation_string":"Equipment performance & sustainability, IREQ (Hydro-Quebec), Montreal, QC, Canada","institution_ids":["https://openalex.org/I47099075"]}]},{"author_position":"middle","author":{"id":"https://openalex.org/A5004800648","display_name":"George C. Fofeldea","orcid":null},"institutions":[{"id":"https://openalex.org/I86519309","display_name":"The University of Texas at Austin","ror":"https://ror.org/00hj54h04","country_code":"US","type":"education","lineage":["https://openalex.org/I86519309"]}],"countries":["US"],"is_corresponding":false,"raw_author_name":"George C. Fofeldea","raw_affiliation_strings":["3M,Electrical division,Austin,TX,USA","Electrical division, 3M, Austin, TX, USA"],"affiliations":[{"raw_affiliation_string":"3M,Electrical division,Austin,TX,USA","institution_ids":["https://openalex.org/I86519309"]},{"raw_affiliation_string":"Electrical division, 3M, Austin, TX, USA","institution_ids":[]}]},{"author_position":"last","author":{"id":"https://openalex.org/A5051223790","display_name":"Ernie M. Rodriguez","orcid":null},"institutions":[{"id":"https://openalex.org/I86519309","display_name":"The University of Texas at Austin","ror":"https://ror.org/00hj54h04","country_code":"US","type":"education","lineage":["https://openalex.org/I86519309"]}],"countries":["US"],"is_corresponding":false,"raw_author_name":"Ernie M. Rodriguez","raw_affiliation_strings":["3M,Electrical division,Austin,TX,USA","Electrical division, 3M, Austin, TX, USA"],"affiliations":[{"raw_affiliation_string":"3M,Electrical division,Austin,TX,USA","institution_ids":["https://openalex.org/I86519309"]},{"raw_affiliation_string":"Electrical division, 3M, Austin, TX, USA","institution_ids":[]}]}],"institutions":[],"countries_distinct_count":2,"institutions_distinct_count":3,"corresponding_author_ids":["https://openalex.org/A5081572659"],"corresponding_institution_ids":["https://openalex.org/I47099075"],"apc_list":null,"apc_paid":null,"fwci":0.0,"has_fulltext":false,"cited_by_count":0,"citation_normalized_percentile":{"value":0.15567944,"is_in_top_1_percent":false,"is_in_top_10_percent":false},"cited_by_percentile_year":null,"biblio":{"volume":null,"issue":null,"first_page":"1","last_page":"5"},"is_retracted":false,"is_paratext":false,"is_xpac":false,"primary_topic":{"id":"https://openalex.org/T10917","display_name":"Smart Grid Security and Resilience","score":0.9883000254631042,"subfield":{"id":"https://openalex.org/subfields/2207","display_name":"Control and Systems Engineering"},"field":{"id":"https://openalex.org/fields/22","display_name":"Engineering"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}},"topics":[{"id":"https://openalex.org/T10917","display_name":"Smart Grid Security and Resilience","score":0.9883000254631042,"subfield":{"id":"https://openalex.org/subfields/2207","display_name":"Control and Systems Engineering"},"field":{"id":"https://openalex.org/fields/22","display_name":"Engineering"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}},{"id":"https://openalex.org/T10603","display_name":"Smart Grid Energy Management","score":0.9775000214576721,"subfield":{"id":"https://openalex.org/subfields/2208","display_name":"Electrical and Electronic Engineering"},"field":{"id":"https://openalex.org/fields/22","display_name":"Engineering"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}},{"id":"https://openalex.org/T12146","display_name":"Power Line Communications and Noise","score":0.9625999927520752,"subfield":{"id":"https://openalex.org/subfields/2208","display_name":"Electrical and Electronic Engineering"},"field":{"id":"https://openalex.org/fields/22","display_name":"Engineering"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}}],"keywords":[{"id":"https://openalex.org/keywords/lagging","display_name":"Lagging","score":0.8098509907722473},{"id":"https://openalex.org/keywords/smart-grid","display_name":"Smart grid","score":0.7707977294921875},{"id":"https://openalex.org/keywords/automation","display_name":"Automation","score":0.6146653294563293},{"id":"https://openalex.org/keywords/computer-science","display_name":"Computer science","score":0.5381103157997131},{"id":"https://openalex.org/keywords/renewable-energy","display_name":"Renewable energy","score":0.484379380941391},{"id":"https://openalex.org/keywords/electric-power-system","display_name":"Electric power system","score":0.410988986492157},{"id":"https://openalex.org/keywords/systems-engineering","display_name":"Systems engineering","score":0.37953513860702515},{"id":"https://openalex.org/keywords/telecommunications","display_name":"Telecommunications","score":0.35329073667526245},{"id":"https://openalex.org/keywords/reliability-engineering","display_name":"Reliability engineering","score":0.3252716660499573},{"id":"https://openalex.org/keywords/power","display_name":"Power (physics)","score":0.3244393765926361},{"id":"https://openalex.org/keywords/engineering","display_name":"Engineering","score":0.3000703454017639},{"id":"https://openalex.org/keywords/electrical-engineering","display_name":"Electrical engineering","score":0.2926296591758728}],"concepts":[{"id":"https://openalex.org/C2776962539","wikidata":"https://www.wikidata.org/wiki/Q6472078","display_name":"Lagging","level":2,"score":0.8098509907722473},{"id":"https://openalex.org/C10558101","wikidata":"https://www.wikidata.org/wiki/Q689855","display_name":"Smart grid","level":2,"score":0.7707977294921875},{"id":"https://openalex.org/C115901376","wikidata":"https://www.wikidata.org/wiki/Q184199","display_name":"Automation","level":2,"score":0.6146653294563293},{"id":"https://openalex.org/C41008148","wikidata":"https://www.wikidata.org/wiki/Q21198","display_name":"Computer science","level":0,"score":0.5381103157997131},{"id":"https://openalex.org/C188573790","wikidata":"https://www.wikidata.org/wiki/Q12705","display_name":"Renewable energy","level":2,"score":0.484379380941391},{"id":"https://openalex.org/C89227174","wikidata":"https://www.wikidata.org/wiki/Q2388981","display_name":"Electric power system","level":3,"score":0.410988986492157},{"id":"https://openalex.org/C201995342","wikidata":"https://www.wikidata.org/wiki/Q682496","display_name":"Systems engineering","level":1,"score":0.37953513860702515},{"id":"https://openalex.org/C76155785","wikidata":"https://www.wikidata.org/wiki/Q418","display_name":"Telecommunications","level":1,"score":0.35329073667526245},{"id":"https://openalex.org/C200601418","wikidata":"https://www.wikidata.org/wiki/Q2193887","display_name":"Reliability engineering","level":1,"score":0.3252716660499573},{"id":"https://openalex.org/C163258240","wikidata":"https://www.wikidata.org/wiki/Q25342","display_name":"Power (physics)","level":2,"score":0.3244393765926361},{"id":"https://openalex.org/C127413603","wikidata":"https://www.wikidata.org/wiki/Q11023","display_name":"Engineering","level":0,"score":0.3000703454017639},{"id":"https://openalex.org/C119599485","wikidata":"https://www.wikidata.org/wiki/Q43035","display_name":"Electrical engineering","level":1,"score":0.2926296591758728},{"id":"https://openalex.org/C71924100","wikidata":"https://www.wikidata.org/wiki/Q11190","display_name":"Medicine","level":0,"score":0.0},{"id":"https://openalex.org/C121332964","wikidata":"https://www.wikidata.org/wiki/Q413","display_name":"Physics","level":0,"score":0.0},{"id":"https://openalex.org/C62520636","wikidata":"https://www.wikidata.org/wiki/Q944","display_name":"Quantum mechanics","level":1,"score":0.0},{"id":"https://openalex.org/C78519656","wikidata":"https://www.wikidata.org/wiki/Q101333","display_name":"Mechanical engineering","level":1,"score":0.0},{"id":"https://openalex.org/C142724271","wikidata":"https://www.wikidata.org/wiki/Q7208","display_name":"Pathology","level":1,"score":0.0}],"mesh":[],"locations_count":1,"locations":[{"id":"doi:10.1109/isgteurope.2019.8905638","is_oa":false,"landing_page_url":"https://doi.org/10.1109/isgteurope.2019.8905638","pdf_url":null,"source":null,"license":null,"license_id":null,"version":"publishedVersion","is_accepted":true,"is_published":true,"raw_source_name":"2019 IEEE PES Innovative Smart Grid Technologies Europe (ISGT-Europe)","raw_type":"proceedings-article"}],"best_oa_location":null,"sustainable_development_goals":[{"score":0.7599999904632568,"id":"https://metadata.un.org/sdg/7","display_name":"Affordable and clean energy"}],"awards":[],"funders":[],"has_content":{"grobid_xml":false,"pdf":false},"content_urls":null,"referenced_works_count":0,"referenced_works":[],"related_works":["https://openalex.org/W2135562825","https://openalex.org/W3145783610","https://openalex.org/W2354181859","https://openalex.org/W2757096358","https://openalex.org/W2472614530","https://openalex.org/W2375646802","https://openalex.org/W2052668055","https://openalex.org/W2162038069","https://openalex.org/W627568556","https://openalex.org/W2358087883"],"abstract_inverted_index":{"Grid":[0],"modernization":[1,14],"brings":[2],"significant":[3],"advantages":[4],"for":[5,38,57,117],"customers.":[6],"One":[7],"of":[8,33,47,92],"the":[9,76,84,115],"factors":[10],"contributing":[11],"to":[12,68,125],"this":[13,82],"is":[15,36,55,87,121,134],"enabling":[16],"intelligent":[17],"communication":[18,130],"across":[19],"sensing,":[20],"measurement,":[21],"and":[22,42,66,72,94,106,129],"control":[23],"layers":[24],"that":[25],"are":[26,78],"embedded":[27],"into":[28],"existing":[29],"power":[30,85],"systems.":[31],"Knowledge":[32],"system":[34,86],"conditions":[35],"required":[37],"both":[39],"real-time":[40],"management":[41],"improved":[43],"maintenance":[44],"strategies.":[45],"Monitoring":[46],"parameters":[48],"such":[49,102],"as":[50],"voltage,":[51],"current,":[52],"temperature,":[53],"etc.":[54],"critical":[56],"many":[58],"smart":[59,95],"distribution":[60,133],"applications.":[61],"The":[62,108],"market":[63],"offer":[64],"sensors":[65],"IEDs":[67],"improve":[69],"network":[70,77],"performance":[71],"their":[73],"numbers":[74],"in":[75,127],"constantly":[79],"increasing.":[80],"At":[81],"time,":[83],"showing":[88],"various":[89],"implementation":[90],"stages":[91],"automation":[93],"applications":[96],"integration":[97],"associated":[98],"with":[99],"structural":[100],"components":[101],"as:":[103],"generation/renewables,":[104],"transmission":[105],"distribution.":[107],"last":[109],"component,":[110],"distribution,":[111],"which":[112],"was":[113],"lagging":[114],"others":[116],"a":[118],"long":[119],"period":[120],"catching":[122],"up,":[123],"due":[124],"advances":[126],"sensing":[128],"technologies.":[131],"Underground":[132],"an":[135],"example.":[136]},"counts_by_year":[],"updated_date":"2025-11-06T03:46:38.306776","created_date":"2025-10-10T00:00:00"}
