{"id":"https://openalex.org/W2990133629","doi":"https://doi.org/10.1109/isgteurope.2019.8905579","title":"Advanced Short-Circuit Current Calculation for Doubly-Fed Induction Generator Based Wind Turbines According to IEC 60909","display_name":"Advanced Short-Circuit Current Calculation for Doubly-Fed Induction Generator Based Wind Turbines According to IEC 60909","publication_year":2019,"publication_date":"2019-09-01","ids":{"openalex":"https://openalex.org/W2990133629","doi":"https://doi.org/10.1109/isgteurope.2019.8905579","mag":"2990133629"},"language":"en","primary_location":{"id":"doi:10.1109/isgteurope.2019.8905579","is_oa":false,"landing_page_url":"https://doi.org/10.1109/isgteurope.2019.8905579","pdf_url":null,"source":null,"license":null,"license_id":null,"version":"publishedVersion","is_accepted":true,"is_published":true,"raw_source_name":"2019 IEEE PES Innovative Smart Grid Technologies Europe (ISGT-Europe)","raw_type":"proceedings-article"},"type":"conference-paper","indexed_in":["crossref"],"open_access":{"is_oa":false,"oa_status":"closed","oa_url":null,"any_repository_has_fulltext":false},"authorships":[{"author_position":"first","author":{"id":"https://openalex.org/A5060466151","display_name":"Thomas Lager","orcid":null},"institutions":[{"id":"https://openalex.org/I114112103","display_name":"Leibniz University Hannover","ror":"https://ror.org/0304hq317","country_code":"DE","type":"education","lineage":["https://openalex.org/I114112103"]}],"countries":["DE"],"is_corresponding":false,"raw_author_name":"Thomas Lager","raw_affiliation_strings":["Institute of Electric Power Systems, Leibniz Universit&#x00E4;t Hannover,Hanover,Germany","Institute of Electric Power Systems, Leibniz Universit\u00e4t Hannover, Hanover, Germany"],"raw_orcid":null,"affiliations":[{"raw_affiliation_string":"Institute of Electric Power Systems, Leibniz Universit&#x00E4;t Hannover,Hanover,Germany","institution_ids":["https://openalex.org/I114112103"]},{"raw_affiliation_string":"Institute of Electric Power Systems, Leibniz Universit\u00e4t Hannover, Hanover, Germany","institution_ids":["https://openalex.org/I114112103"]}]},{"author_position":"last","author":{"id":"https://openalex.org/A5054889817","display_name":"Lutz Hofmann","orcid":"https://orcid.org/0000-0002-3688-6136"},"institutions":[{"id":"https://openalex.org/I114112103","display_name":"Leibniz University Hannover","ror":"https://ror.org/0304hq317","country_code":"DE","type":"education","lineage":["https://openalex.org/I114112103"]}],"countries":["DE"],"is_corresponding":false,"raw_author_name":"Lutz Hofmann","raw_affiliation_strings":["Institute of Electric Power Systems, Leibniz Universit&#x00E4;t Hannover,Hanover,Germany","Institute of Electric Power Systems, Leibniz Universit\u00e4t Hannover, Hanover, Germany"],"raw_orcid":null,"affiliations":[{"raw_affiliation_string":"Institute of Electric Power Systems, Leibniz Universit&#x00E4;t Hannover,Hanover,Germany","institution_ids":["https://openalex.org/I114112103"]},{"raw_affiliation_string":"Institute of Electric Power Systems, Leibniz Universit\u00e4t Hannover, Hanover, Germany","institution_ids":["https://openalex.org/I114112103"]}]}],"institutions":[],"countries_distinct_count":1,"institutions_distinct_count":1,"corresponding_author_ids":[],"corresponding_institution_ids":["https://openalex.org/I114112103"],"apc_list":null,"apc_paid":null,"fwci":0.0,"has_fulltext":false,"cited_by_count":1,"citation_normalized_percentile":{"value":0.17544363,"is_in_top_1_percent":false,"is_in_top_10_percent":false},"cited_by_percentile_year":{"min":90,"max":94},"biblio":{"volume":null,"issue":null,"first_page":"1","last_page":"5"},"is_retracted":false,"is_paratext":false,"is_xpac":false,"primary_topic":{"id":"https://openalex.org/T10740","display_name":"Wind Turbine Control Systems","score":0.9995999932289124,"subfield":{"id":"https://openalex.org/subfields/2208","display_name":"Electrical and Electronic Engineering"},"field":{"id":"https://openalex.org/fields/22","display_name":"Engineering"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}},"topics":[{"id":"https://openalex.org/T10740","display_name":"Wind Turbine Control Systems","score":0.9995999932289124,"subfield":{"id":"https://openalex.org/subfields/2208","display_name":"Electrical and Electronic Engineering"},"field":{"id":"https://openalex.org/fields/22","display_name":"Engineering"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}},{"id":"https://openalex.org/T10680","display_name":"Wind Energy Research and Development","score":0.9983000159263611,"subfield":{"id":"https://openalex.org/subfields/2202","display_name":"Aerospace Engineering"},"field":{"id":"https://openalex.org/fields/22","display_name":"Engineering"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}},{"id":"https://openalex.org/T10278","display_name":"Electric Motor Design and Analysis","score":0.9977999925613403,"subfield":{"id":"https://openalex.org/subfields/2208","display_name":"Electrical and Electronic Engineering"},"field":{"id":"https://openalex.org/fields/22","display_name":"Engineering"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}}],"keywords":[{"id":"https://openalex.org/keywords/induction-generator","display_name":"Induction generator","score":0.7676770687103271},{"id":"https://openalex.org/keywords/stator","display_name":"Stator","score":0.6745916604995728},{"id":"https://openalex.org/keywords/rotor","display_name":"Rotor (electric)","score":0.6340519785881042},{"id":"https://openalex.org/keywords/wind-power","display_name":"Wind power","score":0.6324415802955627},{"id":"https://openalex.org/keywords/electrical-impedance","display_name":"Electrical impedance","score":0.6005354523658752},{"id":"https://openalex.org/keywords/current","display_name":"Current (fluid)","score":0.5932153463363647},{"id":"https://openalex.org/keywords/doubly-fed-electric-machine","display_name":"Doubly fed electric machine","score":0.5816451907157898},{"id":"https://openalex.org/keywords/short-circuit","display_name":"Short circuit","score":0.5431179404258728},{"id":"https://openalex.org/keywords/control-theory","display_name":"Control theory (sociology)","score":0.5211053490638733},{"id":"https://openalex.org/keywords/voltage","display_name":"Voltage","score":0.4913610517978668},{"id":"https://openalex.org/keywords/equivalent-circuit","display_name":"Equivalent circuit","score":0.4908600449562073},{"id":"https://openalex.org/keywords/generator","display_name":"Generator (circuit theory)","score":0.4871687591075897},{"id":"https://openalex.org/keywords/engineering","display_name":"Engineering","score":0.39781755208969116},{"id":"https://openalex.org/keywords/computer-science","display_name":"Computer science","score":0.35542023181915283},{"id":"https://openalex.org/keywords/electrical-engineering","display_name":"Electrical engineering","score":0.3481099605560303},{"id":"https://openalex.org/keywords/physics","display_name":"Physics","score":0.2501569390296936},{"id":"https://openalex.org/keywords/ac-power","display_name":"AC power","score":0.22317135334014893},{"id":"https://openalex.org/keywords/power","display_name":"Power (physics)","score":0.09628832340240479}],"concepts":[{"id":"https://openalex.org/C98716924","wikidata":"https://www.wikidata.org/wiki/Q752750","display_name":"Induction generator","level":3,"score":0.7676770687103271},{"id":"https://openalex.org/C2776529397","wikidata":"https://www.wikidata.org/wiki/Q190312","display_name":"Stator","level":2,"score":0.6745916604995728},{"id":"https://openalex.org/C17281054","wikidata":"https://www.wikidata.org/wiki/Q193466","display_name":"Rotor (electric)","level":2,"score":0.6340519785881042},{"id":"https://openalex.org/C78600449","wikidata":"https://www.wikidata.org/wiki/Q43302","display_name":"Wind power","level":2,"score":0.6324415802955627},{"id":"https://openalex.org/C17829176","wikidata":"https://www.wikidata.org/wiki/Q179043","display_name":"Electrical impedance","level":2,"score":0.6005354523658752},{"id":"https://openalex.org/C148043351","wikidata":"https://www.wikidata.org/wiki/Q4456944","display_name":"Current (fluid)","level":2,"score":0.5932153463363647},{"id":"https://openalex.org/C200971846","wikidata":"https://www.wikidata.org/wiki/Q1420518","display_name":"Doubly fed electric machine","level":4,"score":0.5816451907157898},{"id":"https://openalex.org/C68583231","wikidata":"https://www.wikidata.org/wiki/Q206907","display_name":"Short circuit","level":3,"score":0.5431179404258728},{"id":"https://openalex.org/C47446073","wikidata":"https://www.wikidata.org/wiki/Q5165890","display_name":"Control theory (sociology)","level":3,"score":0.5211053490638733},{"id":"https://openalex.org/C165801399","wikidata":"https://www.wikidata.org/wiki/Q25428","display_name":"Voltage","level":2,"score":0.4913610517978668},{"id":"https://openalex.org/C23572009","wikidata":"https://www.wikidata.org/wiki/Q964981","display_name":"Equivalent circuit","level":3,"score":0.4908600449562073},{"id":"https://openalex.org/C2780992000","wikidata":"https://www.wikidata.org/wiki/Q17016113","display_name":"Generator (circuit theory)","level":3,"score":0.4871687591075897},{"id":"https://openalex.org/C127413603","wikidata":"https://www.wikidata.org/wiki/Q11023","display_name":"Engineering","level":0,"score":0.39781755208969116},{"id":"https://openalex.org/C41008148","wikidata":"https://www.wikidata.org/wiki/Q21198","display_name":"Computer science","level":0,"score":0.35542023181915283},{"id":"https://openalex.org/C119599485","wikidata":"https://www.wikidata.org/wiki/Q43035","display_name":"Electrical engineering","level":1,"score":0.3481099605560303},{"id":"https://openalex.org/C121332964","wikidata":"https://www.wikidata.org/wiki/Q413","display_name":"Physics","level":0,"score":0.2501569390296936},{"id":"https://openalex.org/C108755667","wikidata":"https://www.wikidata.org/wiki/Q1930258","display_name":"AC power","level":3,"score":0.22317135334014893},{"id":"https://openalex.org/C163258240","wikidata":"https://www.wikidata.org/wiki/Q25342","display_name":"Power (physics)","level":2,"score":0.09628832340240479},{"id":"https://openalex.org/C154945302","wikidata":"https://www.wikidata.org/wiki/Q11660","display_name":"Artificial intelligence","level":1,"score":0.0},{"id":"https://openalex.org/C62520636","wikidata":"https://www.wikidata.org/wiki/Q944","display_name":"Quantum mechanics","level":1,"score":0.0},{"id":"https://openalex.org/C2775924081","wikidata":"https://www.wikidata.org/wiki/Q55608371","display_name":"Control (management)","level":2,"score":0.0}],"mesh":[],"locations_count":1,"locations":[{"id":"doi:10.1109/isgteurope.2019.8905579","is_oa":false,"landing_page_url":"https://doi.org/10.1109/isgteurope.2019.8905579","pdf_url":null,"source":null,"license":null,"license_id":null,"version":"publishedVersion","is_accepted":true,"is_published":true,"raw_source_name":"2019 IEEE PES Innovative Smart Grid Technologies Europe (ISGT-Europe)","raw_type":"proceedings-article"}],"best_oa_location":null,"sustainable_development_goals":[{"score":0.8999999761581421,"display_name":"Affordable and clean energy","id":"https://metadata.un.org/sdg/7"}],"awards":[],"funders":[],"has_content":{"pdf":false,"grobid_xml":false},"content_urls":null,"referenced_works_count":4,"referenced_works":["https://openalex.org/W568756109","https://openalex.org/W2210072541","https://openalex.org/W2970264321","https://openalex.org/W4285719527"],"related_works":["https://openalex.org/W4299603952","https://openalex.org/W2075094391","https://openalex.org/W3115699807","https://openalex.org/W2710298203","https://openalex.org/W4213246261","https://openalex.org/W2886891539","https://openalex.org/W2312609498","https://openalex.org/W2373960390","https://openalex.org/W4294151797","https://openalex.org/W1573282862"],"abstract_inverted_index":{"In":[0],"this":[1,70],"paper,":[2],"an":[3,63,81,97],"advanced":[4,64,98],"approach":[5,66],"to":[6,23,60,85],"calculate":[7],"the":[8,40,50,89,101,105],"short-circuit":[9,29,36],"current":[10,37,103,108],"contribution":[11,38],"of":[12,39,88,100,109],"wind":[13],"turbines":[14],"based":[15],"on":[16],"doubly":[17],"fed":[18],"induction":[19],"generators":[20],"(DFIGs)":[21],"according":[22],"IEC":[24,112],"60909":[25],"for":[26,42,76,95],"a":[27,72,93],"three-phase":[28],"is":[30,47,67,78,114],"presented":[31],"and":[32,52,104],"analysed.":[33],"The":[34],"initial":[35],"DFIG":[41,77,110],"various":[43],"rotor":[44],"voltage":[45],"settings":[46],"calculated":[48],"with":[49,80],"top":[51],"bottom":[53],"envelope":[54],"derived":[55],"by":[56],"several":[57],"interpolations.":[58],"Due":[59],"unreliable":[61],"results,":[62],"analytical":[65],"proposed.":[68],"Within":[69],"approach,":[71],"simplified":[73],"impedance":[74],"calculation":[75],"suggested":[79],"additional":[82],"correction":[83],"factor":[84],"counteract":[86],"inaccuracies":[87],"considered":[90],"assumptions.":[91],"Therefore,":[92],"possibility":[94],"deducing":[96],"consideration":[99],"stator":[102],"LSC":[106],"grid":[107],"in":[111],"60909-0":[113],"displayed.":[115]},"counts_by_year":[{"year":2023,"cited_by_count":1}],"updated_date":"2026-07-29T14:22:42.915294","created_date":"2025-10-10T00:00:00"}