{"id":"https://openalex.org/W2991259016","doi":"https://doi.org/10.1109/isgteurope.2019.8905497","title":"Agent-based Distributed Finite-time Secondary Control of Energy Storage Systems in Microgrids \u2014 Controller Hardware-in-the-Loop Validation","display_name":"Agent-based Distributed Finite-time Secondary Control of Energy Storage Systems in Microgrids \u2014 Controller Hardware-in-the-Loop Validation","publication_year":2019,"publication_date":"2019-09-01","ids":{"openalex":"https://openalex.org/W2991259016","doi":"https://doi.org/10.1109/isgteurope.2019.8905497","mag":"2991259016"},"language":"en","primary_location":{"id":"doi:10.1109/isgteurope.2019.8905497","is_oa":false,"landing_page_url":"https://doi.org/10.1109/isgteurope.2019.8905497","pdf_url":null,"source":null,"license":null,"license_id":null,"version":"publishedVersion","is_accepted":true,"is_published":true,"raw_source_name":"2019 IEEE PES Innovative Smart Grid Technologies Europe (ISGT-Europe)","raw_type":"proceedings-article"},"type":"article","indexed_in":["crossref"],"open_access":{"is_oa":false,"oa_status":"closed","oa_url":null,"any_repository_has_fulltext":false},"authorships":[{"author_position":"first","author":{"id":null,"display_name":"Tung-Lam Nguyen","orcid":null},"institutions":[{"id":"https://openalex.org/I4210165697","display_name":"Laboratoire de G\u00e9nie \u00c9lectrique de Grenoble","ror":"https://ror.org/05hyx5a17","country_code":"FR","type":"facility","lineage":["https://openalex.org/I106785703","https://openalex.org/I1294671590","https://openalex.org/I1294671590","https://openalex.org/I4210095849","https://openalex.org/I4210165697","https://openalex.org/I899635006","https://openalex.org/I899635006"]},{"id":"https://openalex.org/I899635006","display_name":"Universit\u00e9 Grenoble Alpes","ror":"https://ror.org/02rx3b187","country_code":"FR","type":"education","lineage":["https://openalex.org/I899635006"]}],"countries":["FR"],"is_corresponding":true,"raw_author_name":"Tung-Lam Nguyen","raw_affiliation_strings":["Univ. Grenoble Alpes, G2Elab,Grenoble,France,F-38000","G2ELab - Laboratoire de G\u00e9nie Electrique de Grenoble (B\u00e2timent GreEn-ER, 21 avenue des martyrs, CS 90624, 38031 Grenoble CEDEX 1 - France)"],"affiliations":[{"raw_affiliation_string":"Univ. Grenoble Alpes, G2Elab,Grenoble,France,F-38000","institution_ids":["https://openalex.org/I4210165697","https://openalex.org/I899635006"]},{"raw_affiliation_string":"G2ELab - Laboratoire de G\u00e9nie Electrique de Grenoble (B\u00e2timent GreEn-ER, 21 avenue des martyrs, CS 90624, 38031 Grenoble CEDEX 1 - France)","institution_ids":["https://openalex.org/I4210165697"]}]},{"author_position":"middle","author":{"id":"https://openalex.org/A5100698936","display_name":"Yu Wang","orcid":"https://orcid.org/0000-0002-9750-324X"},"institutions":[{"id":"https://openalex.org/I172675005","display_name":"Nanyang Technological University","ror":"https://ror.org/02e7b5302","country_code":"SG","type":"education","lineage":["https://openalex.org/I172675005"]}],"countries":["SG"],"is_corresponding":false,"raw_author_name":"Yu Wang","raw_affiliation_strings":["Nanyang Technological University,Singapore","NTU - Nanayang Technological University (Singapore)"],"affiliations":[{"raw_affiliation_string":"Nanyang Technological University,Singapore","institution_ids":["https://openalex.org/I172675005"]},{"raw_affiliation_string":"NTU - Nanayang Technological University (Singapore)","institution_ids":["https://openalex.org/I172675005"]}]},{"author_position":"middle","author":{"id":"https://openalex.org/A5088874619","display_name":"Quoc Tuan Tran","orcid":"https://orcid.org/0000-0003-4733-1571"},"institutions":[{"id":"https://openalex.org/I2738703131","display_name":"Commissariat \u00e0 l'\u00c9nergie Atomique et aux \u00c9nergies Alternatives","ror":"https://ror.org/00jjx8s55","country_code":"FR","type":"government","lineage":["https://openalex.org/I2738703131"]},{"id":"https://openalex.org/I4210094700","display_name":"Institut National de l'\u00c9nergie Solaire","ror":"https://ror.org/00qk0vr83","country_code":"FR","type":"facility","lineage":["https://openalex.org/I1294671590","https://openalex.org/I2738703131","https://openalex.org/I4210089901","https://openalex.org/I4210094700","https://openalex.org/I4210139971","https://openalex.org/I70900168"]}],"countries":["FR"],"is_corresponding":false,"raw_author_name":"Quoc-Tuan Tran","raw_affiliation_strings":["CEA-INES,Le Bourget-du-lac,France","INES - Institut National de L'Energie Solaire (Parc Technologique de Savoie Technolac 50 Av. du Lac L\u00e9man, B\u00e2timent Lynx - BP 332 F-73377 Le Bourget-du-Lac cedex - France)"],"affiliations":[{"raw_affiliation_string":"CEA-INES,Le Bourget-du-lac,France","institution_ids":["https://openalex.org/I2738703131","https://openalex.org/I4210094700"]},{"raw_affiliation_string":"INES - Institut National de L'Energie Solaire (Parc Technologique de Savoie Technolac 50 Av. du Lac L\u00e9man, B\u00e2timent Lynx - BP 332 F-73377 Le Bourget-du-Lac cedex - France)","institution_ids":["https://openalex.org/I4210094700"]}]},{"author_position":"middle","author":{"id":"https://openalex.org/A5044157955","display_name":"Rapha\u00ebl Caire","orcid":"https://orcid.org/0000-0003-4041-3507"},"institutions":[{"id":"https://openalex.org/I4210165697","display_name":"Laboratoire de G\u00e9nie \u00c9lectrique de Grenoble","ror":"https://ror.org/05hyx5a17","country_code":"FR","type":"facility","lineage":["https://openalex.org/I106785703","https://openalex.org/I1294671590","https://openalex.org/I1294671590","https://openalex.org/I4210095849","https://openalex.org/I4210165697","https://openalex.org/I899635006","https://openalex.org/I899635006"]},{"id":"https://openalex.org/I899635006","display_name":"Universit\u00e9 Grenoble Alpes","ror":"https://ror.org/02rx3b187","country_code":"FR","type":"education","lineage":["https://openalex.org/I899635006"]}],"countries":["FR"],"is_corresponding":false,"raw_author_name":"Raphael Caire","raw_affiliation_strings":["Univ. Grenoble Alpes, G2Elab,Grenoble,France,F-38000","G2ELab - Laboratoire de G\u00e9nie Electrique de Grenoble (B\u00e2timent GreEn-ER, 21 avenue des martyrs, CS 90624, 38031 Grenoble CEDEX 1 - France)"],"affiliations":[{"raw_affiliation_string":"Univ. Grenoble Alpes, G2Elab,Grenoble,France,F-38000","institution_ids":["https://openalex.org/I4210165697","https://openalex.org/I899635006"]},{"raw_affiliation_string":"G2ELab - Laboratoire de G\u00e9nie Electrique de Grenoble (B\u00e2timent GreEn-ER, 21 avenue des martyrs, CS 90624, 38031 Grenoble CEDEX 1 - France)","institution_ids":["https://openalex.org/I4210165697"]}]},{"author_position":"last","author":{"id":"https://openalex.org/A5107861018","display_name":"Yvon B\u00e9sanger","orcid":null},"institutions":[{"id":"https://openalex.org/I4210165697","display_name":"Laboratoire de G\u00e9nie \u00c9lectrique de Grenoble","ror":"https://ror.org/05hyx5a17","country_code":"FR","type":"facility","lineage":["https://openalex.org/I106785703","https://openalex.org/I1294671590","https://openalex.org/I1294671590","https://openalex.org/I4210095849","https://openalex.org/I4210165697","https://openalex.org/I899635006","https://openalex.org/I899635006"]},{"id":"https://openalex.org/I899635006","display_name":"Universit\u00e9 Grenoble Alpes","ror":"https://ror.org/02rx3b187","country_code":"FR","type":"education","lineage":["https://openalex.org/I899635006"]}],"countries":["FR"],"is_corresponding":false,"raw_author_name":"Yvon Besanger","raw_affiliation_strings":["Univ. Grenoble Alpes, G2Elab,Grenoble,France,F-38000","G2ELab - Laboratoire de G\u00e9nie Electrique de Grenoble (B\u00e2timent GreEn-ER, 21 avenue des martyrs, CS 90624, 38031 Grenoble CEDEX 1 - France)"],"affiliations":[{"raw_affiliation_string":"Univ. Grenoble Alpes, G2Elab,Grenoble,France,F-38000","institution_ids":["https://openalex.org/I4210165697","https://openalex.org/I899635006"]},{"raw_affiliation_string":"G2ELab - Laboratoire de G\u00e9nie Electrique de Grenoble (B\u00e2timent GreEn-ER, 21 avenue des martyrs, CS 90624, 38031 Grenoble CEDEX 1 - France)","institution_ids":["https://openalex.org/I4210165697"]}]}],"institutions":[],"countries_distinct_count":2,"institutions_distinct_count":5,"corresponding_author_ids":[],"corresponding_institution_ids":["https://openalex.org/I4210165697","https://openalex.org/I899635006"],"apc_list":null,"apc_paid":null,"fwci":0.1685,"has_fulltext":false,"cited_by_count":2,"citation_normalized_percentile":{"value":0.51388076,"is_in_top_1_percent":false,"is_in_top_10_percent":false},"cited_by_percentile_year":{"min":90,"max":95},"biblio":{"volume":null,"issue":null,"first_page":"1","last_page":"5"},"is_retracted":false,"is_paratext":false,"is_xpac":false,"primary_topic":{"id":"https://openalex.org/T10223","display_name":"Microgrid Control and Optimization","score":0.9997000098228455,"subfield":{"id":"https://openalex.org/subfields/2207","display_name":"Control and Systems Engineering"},"field":{"id":"https://openalex.org/fields/22","display_name":"Engineering"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}},"topics":[{"id":"https://openalex.org/T10223","display_name":"Microgrid Control and Optimization","score":0.9997000098228455,"subfield":{"id":"https://openalex.org/subfields/2207","display_name":"Control and Systems Engineering"},"field":{"id":"https://openalex.org/fields/22","display_name":"Engineering"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}},{"id":"https://openalex.org/T10249","display_name":"Distributed Control Multi-Agent Systems","score":0.9904000163078308,"subfield":{"id":"https://openalex.org/subfields/1705","display_name":"Computer Networks and Communications"},"field":{"id":"https://openalex.org/fields/17","display_name":"Computer Science"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}},{"id":"https://openalex.org/T10603","display_name":"Smart Grid Energy Management","score":0.987500011920929,"subfield":{"id":"https://openalex.org/subfields/2208","display_name":"Electrical and Electronic Engineering"},"field":{"id":"https://openalex.org/fields/22","display_name":"Engineering"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}}],"keywords":[{"id":"https://openalex.org/keywords/microgrid","display_name":"Microgrid","score":0.9442671537399292},{"id":"https://openalex.org/keywords/controller","display_name":"Controller (irrigation)","score":0.6793199777603149},{"id":"https://openalex.org/keywords/computer-science","display_name":"Computer science","score":0.6008340120315552},{"id":"https://openalex.org/keywords/hardware-in-the-loop-simulation","display_name":"Hardware-in-the-loop simulation","score":0.5941111445426941},{"id":"https://openalex.org/keywords/overshoot","display_name":"Overshoot (microwave communication)","score":0.5756765604019165},{"id":"https://openalex.org/keywords/energy-storage","display_name":"Energy storage","score":0.4988691806793213},{"id":"https://openalex.org/keywords/scheme","display_name":"Scheme (mathematics)","score":0.4615398049354553},{"id":"https://openalex.org/keywords/power","display_name":"Power (physics)","score":0.35354721546173096},{"id":"https://openalex.org/keywords/embedded-system","display_name":"Embedded system","score":0.31975436210632324},{"id":"https://openalex.org/keywords/control","display_name":"Control (management)","score":0.2776781916618347}],"concepts":[{"id":"https://openalex.org/C2776784348","wikidata":"https://www.wikidata.org/wiki/Q5762595","display_name":"Microgrid","level":3,"score":0.9442671537399292},{"id":"https://openalex.org/C203479927","wikidata":"https://www.wikidata.org/wiki/Q5165939","display_name":"Controller (irrigation)","level":2,"score":0.6793199777603149},{"id":"https://openalex.org/C41008148","wikidata":"https://www.wikidata.org/wiki/Q21198","display_name":"Computer science","level":0,"score":0.6008340120315552},{"id":"https://openalex.org/C70587628","wikidata":"https://www.wikidata.org/wiki/Q1142371","display_name":"Hardware-in-the-loop simulation","level":2,"score":0.5941111445426941},{"id":"https://openalex.org/C2780323453","wikidata":"https://www.wikidata.org/wiki/Q7113957","display_name":"Overshoot (microwave communication)","level":2,"score":0.5756765604019165},{"id":"https://openalex.org/C73916439","wikidata":"https://www.wikidata.org/wiki/Q837718","display_name":"Energy storage","level":3,"score":0.4988691806793213},{"id":"https://openalex.org/C77618280","wikidata":"https://www.wikidata.org/wiki/Q1155772","display_name":"Scheme (mathematics)","level":2,"score":0.4615398049354553},{"id":"https://openalex.org/C163258240","wikidata":"https://www.wikidata.org/wiki/Q25342","display_name":"Power (physics)","level":2,"score":0.35354721546173096},{"id":"https://openalex.org/C149635348","wikidata":"https://www.wikidata.org/wiki/Q193040","display_name":"Embedded system","level":1,"score":0.31975436210632324},{"id":"https://openalex.org/C2775924081","wikidata":"https://www.wikidata.org/wiki/Q55608371","display_name":"Control (management)","level":2,"score":0.2776781916618347},{"id":"https://openalex.org/C86803240","wikidata":"https://www.wikidata.org/wiki/Q420","display_name":"Biology","level":0,"score":0.0},{"id":"https://openalex.org/C62520636","wikidata":"https://www.wikidata.org/wiki/Q944","display_name":"Quantum mechanics","level":1,"score":0.0},{"id":"https://openalex.org/C134306372","wikidata":"https://www.wikidata.org/wiki/Q7754","display_name":"Mathematical analysis","level":1,"score":0.0},{"id":"https://openalex.org/C154945302","wikidata":"https://www.wikidata.org/wiki/Q11660","display_name":"Artificial intelligence","level":1,"score":0.0},{"id":"https://openalex.org/C6557445","wikidata":"https://www.wikidata.org/wiki/Q173113","display_name":"Agronomy","level":1,"score":0.0},{"id":"https://openalex.org/C121332964","wikidata":"https://www.wikidata.org/wiki/Q413","display_name":"Physics","level":0,"score":0.0},{"id":"https://openalex.org/C33923547","wikidata":"https://www.wikidata.org/wiki/Q395","display_name":"Mathematics","level":0,"score":0.0},{"id":"https://openalex.org/C76155785","wikidata":"https://www.wikidata.org/wiki/Q418","display_name":"Telecommunications","level":1,"score":0.0}],"mesh":[],"locations_count":2,"locations":[{"id":"doi:10.1109/isgteurope.2019.8905497","is_oa":false,"landing_page_url":"https://doi.org/10.1109/isgteurope.2019.8905497","pdf_url":null,"source":null,"license":null,"license_id":null,"version":"publishedVersion","is_accepted":true,"is_published":true,"raw_source_name":"2019 IEEE PES Innovative Smart Grid Technologies Europe (ISGT-Europe)","raw_type":"proceedings-article"},{"id":"pmh:oai:HAL:hal-04776720v1","is_oa":false,"landing_page_url":"https://hal.science/hal-04776720","pdf_url":null,"source":{"id":"https://openalex.org/S4406922461","display_name":"SPIRE - Sciences Po Institutional REpository","issn_l":null,"issn":null,"is_oa":false,"is_in_doaj":false,"is_core":false,"host_organization":null,"host_organization_name":null,"host_organization_lineage":[],"host_organization_lineage_names":[],"type":"repository"},"license":null,"license_id":null,"version":"submittedVersion","is_accepted":false,"is_published":false,"raw_source_name":"2019 IEEE PES Innovative Smart Grid Technologies Europe (ISGT-Europe), Sep 2019, Bucharest, France. pp.1-5, &#x27E8;10.1109/ISGTEurope.2019.8905497&#x27E9;","raw_type":"Conference papers"}],"best_oa_location":null,"sustainable_development_goals":[{"id":"https://metadata.un.org/sdg/7","display_name":"Affordable and clean energy","score":0.8700000047683716}],"awards":[],"funders":[],"has_content":{"pdf":false,"grobid_xml":false},"content_urls":null,"referenced_works_count":9,"referenced_works":["https://openalex.org/W1994440383","https://openalex.org/W2074229485","https://openalex.org/W2095411820","https://openalex.org/W2143843955","https://openalex.org/W2550409724","https://openalex.org/W2566906344","https://openalex.org/W2608925587","https://openalex.org/W2737628516","https://openalex.org/W6737216508"],"related_works":["https://openalex.org/W1574359403","https://openalex.org/W2057975886","https://openalex.org/W4308700935","https://openalex.org/W4210780382","https://openalex.org/W2356033827","https://openalex.org/W2391138633","https://openalex.org/W3037384208","https://openalex.org/W1600945217","https://openalex.org/W1932401759","https://openalex.org/W2354175256"],"abstract_inverted_index":{"In":[0],"this":[1],"paper,":[2],"we":[3],"proposed":[4,46,109,128],"a":[5,56,84],"novel":[6],"agent-based":[7],"distributed":[8],"secondary":[9],"control":[10,47,98,110],"strategy":[11],"for":[12],"energy":[13],"storage":[14],"systems":[15,76],"(ESSs)":[16],"in":[17,55,77,83],"islanded":[18,104],"ac":[19,105],"microgrids.":[20],"Agents":[21],"are":[22],"designed":[23],"to":[24],"deploy":[25],"the":[26,45,51,80,91,108,116,122,127],"finite-time":[27],"consensus":[28],"algorithm":[29],"with":[30,44,59,74,107],"non-linear":[31],"law":[32],"by":[33],"receiving":[34],"limited":[35],"information":[36],"from":[37],"local":[38],"and":[39,63,79,100,124],"neighbor":[40],"agents.":[41],"The":[42,118],"ESSs":[43],"scheme":[48,111],"can":[49],"achieve":[50],"balance":[52],"of":[53,93,126],"state-of-charge":[54],"good":[57],"performance":[58,123],"small":[60],"power":[61],"overshoot":[62],"fast":[64],"converge":[65],"speed.":[66],"A":[67],"Controller":[68],"Hardware-in-the-Loop":[69],"microgrid":[70,96,106],"platform":[71,89],"is":[72],"provided":[73],"physical":[75],"OPAL-RT":[78],"agent":[81],"system":[82],"Raspberry":[85],"Pis":[86],"cluster.":[87],"This":[88],"enables":[90],"investigation":[92],"interactions":[94],"among":[95],"entities,":[97],"systems,":[99],"communication":[101],"networks.":[102],"An":[103],"has":[112],"been":[113],"implemented":[114],"on":[115],"platform.":[117],"experiment":[119],"results":[120],"demonstrate":[121],"advantages":[125],"method.":[129]},"counts_by_year":[{"year":2025,"cited_by_count":1},{"year":2022,"cited_by_count":1}],"updated_date":"2026-04-21T08:09:41.155169","created_date":"2025-10-10T00:00:00"}
