{"id":"https://openalex.org/W2904079384","doi":"https://doi.org/10.1109/isgteurope.2018.8571862","title":"Fast Distribution Grid State Estimation Using Improved Sensitivity Analysis","display_name":"Fast Distribution Grid State Estimation Using Improved Sensitivity Analysis","publication_year":2018,"publication_date":"2018-10-01","ids":{"openalex":"https://openalex.org/W2904079384","doi":"https://doi.org/10.1109/isgteurope.2018.8571862","mag":"2904079384"},"language":"en","primary_location":{"id":"doi:10.1109/isgteurope.2018.8571862","is_oa":false,"landing_page_url":"https://doi.org/10.1109/isgteurope.2018.8571862","pdf_url":null,"source":null,"license":null,"license_id":null,"version":"publishedVersion","is_accepted":true,"is_published":true,"raw_source_name":"2018 IEEE PES Innovative Smart Grid Technologies Conference Europe (ISGT-Europe)","raw_type":"proceedings-article"},"type":"article","indexed_in":["crossref"],"open_access":{"is_oa":false,"oa_status":"closed","oa_url":null,"any_repository_has_fulltext":false},"authorships":[{"author_position":"first","author":{"id":"https://openalex.org/A5041017390","display_name":"Philippe Steinbusch","orcid":null},"institutions":[{"id":"https://openalex.org/I167360494","display_name":"University of Wuppertal","ror":"https://ror.org/00613ak93","country_code":"DE","type":"education","lineage":["https://openalex.org/I167360494"]}],"countries":["DE"],"is_corresponding":true,"raw_author_name":"Philippe Steinbusch","raw_affiliation_strings":["Institute of Power System Engineering, University of Wuppertal, Wuppertal, Germany"],"affiliations":[{"raw_affiliation_string":"Institute of Power System Engineering, University of Wuppertal, Wuppertal, Germany","institution_ids":["https://openalex.org/I167360494"]}]},{"author_position":"middle","author":{"id":"https://openalex.org/A5065766969","display_name":"Marcel Modernann","orcid":null},"institutions":[{"id":"https://openalex.org/I167360494","display_name":"University of Wuppertal","ror":"https://ror.org/00613ak93","country_code":"DE","type":"education","lineage":["https://openalex.org/I167360494"]}],"countries":["DE"],"is_corresponding":false,"raw_author_name":"Marcel Modernann","raw_affiliation_strings":["Institute of Power System Engineering, University of Wuppertal, Wuppertal, Germany"],"affiliations":[{"raw_affiliation_string":"Institute of Power System Engineering, University of Wuppertal, Wuppertal, Germany","institution_ids":["https://openalex.org/I167360494"]}]},{"author_position":"middle","author":{"id":"https://openalex.org/A5069798128","display_name":"Mahjar Wazifehdust","orcid":null},"institutions":[{"id":"https://openalex.org/I167360494","display_name":"University of Wuppertal","ror":"https://ror.org/00613ak93","country_code":"DE","type":"education","lineage":["https://openalex.org/I167360494"]}],"countries":["DE"],"is_corresponding":false,"raw_author_name":"Mahjar Wazifehdust","raw_affiliation_strings":["Institute of Power System Engineering, University of Wuppertal, Wuppertal, Germany"],"affiliations":[{"raw_affiliation_string":"Institute of Power System Engineering, University of Wuppertal, Wuppertal, Germany","institution_ids":["https://openalex.org/I167360494"]}]},{"author_position":"last","author":{"id":"https://openalex.org/A5087138881","display_name":"Markus Zdrallek","orcid":null},"institutions":[{"id":"https://openalex.org/I167360494","display_name":"University of Wuppertal","ror":"https://ror.org/00613ak93","country_code":"DE","type":"education","lineage":["https://openalex.org/I167360494"]}],"countries":["DE"],"is_corresponding":false,"raw_author_name":"Markus Zdrallek","raw_affiliation_strings":["Institute of Power System Engineering, University of Wuppertal, Wuppertal, Germany"],"affiliations":[{"raw_affiliation_string":"Institute of Power System Engineering, University of Wuppertal, Wuppertal, Germany","institution_ids":["https://openalex.org/I167360494"]}]}],"institutions":[],"countries_distinct_count":1,"institutions_distinct_count":4,"corresponding_author_ids":["https://openalex.org/A5041017390"],"corresponding_institution_ids":["https://openalex.org/I167360494"],"apc_list":null,"apc_paid":null,"fwci":0.1288,"has_fulltext":false,"cited_by_count":1,"citation_normalized_percentile":{"value":0.50665473,"is_in_top_1_percent":false,"is_in_top_10_percent":false},"cited_by_percentile_year":{"min":89,"max":94},"biblio":{"volume":null,"issue":null,"first_page":"1","last_page":"6"},"is_retracted":false,"is_paratext":false,"is_xpac":false,"primary_topic":{"id":"https://openalex.org/T10305","display_name":"Power System Optimization and Stability","score":0.9997000098228455,"subfield":{"id":"https://openalex.org/subfields/2208","display_name":"Electrical and Electronic Engineering"},"field":{"id":"https://openalex.org/fields/22","display_name":"Engineering"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}},"topics":[{"id":"https://openalex.org/T10305","display_name":"Power System Optimization and Stability","score":0.9997000098228455,"subfield":{"id":"https://openalex.org/subfields/2208","display_name":"Electrical and Electronic Engineering"},"field":{"id":"https://openalex.org/fields/22","display_name":"Engineering"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}},{"id":"https://openalex.org/T10917","display_name":"Smart Grid Security and Resilience","score":0.998199999332428,"subfield":{"id":"https://openalex.org/subfields/2207","display_name":"Control and Systems Engineering"},"field":{"id":"https://openalex.org/fields/22","display_name":"Engineering"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}},{"id":"https://openalex.org/T10454","display_name":"Optimal Power Flow Distribution","score":0.9957000017166138,"subfield":{"id":"https://openalex.org/subfields/2208","display_name":"Electrical and Electronic Engineering"},"field":{"id":"https://openalex.org/fields/22","display_name":"Engineering"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}}],"keywords":[{"id":"https://openalex.org/keywords/sensitivity","display_name":"Sensitivity (control systems)","score":0.8063623309135437},{"id":"https://openalex.org/keywords/smart-grid","display_name":"Smart grid","score":0.7440224289894104},{"id":"https://openalex.org/keywords/computer-science","display_name":"Computer science","score":0.7209110260009766},{"id":"https://openalex.org/keywords/flexibility","display_name":"Flexibility (engineering)","score":0.7150094509124756},{"id":"https://openalex.org/keywords/grid","display_name":"Grid","score":0.6695663332939148},{"id":"https://openalex.org/keywords/reliability-engineering","display_name":"Reliability engineering","score":0.49510636925697327},{"id":"https://openalex.org/keywords/field","display_name":"Field (mathematics)","score":0.4776909649372101},{"id":"https://openalex.org/keywords/function","display_name":"Function (biology)","score":0.45623019337654114},{"id":"https://openalex.org/keywords/state","display_name":"State (computer science)","score":0.42982667684555054},{"id":"https://openalex.org/keywords/distributed-computing","display_name":"Distributed computing","score":0.42602774500846863},{"id":"https://openalex.org/keywords/control-engineering","display_name":"Control engineering","score":0.36063066124916077},{"id":"https://openalex.org/keywords/real-time-computing","display_name":"Real-time computing","score":0.344099223613739},{"id":"https://openalex.org/keywords/electronic-engineering","display_name":"Electronic engineering","score":0.33807286620140076},{"id":"https://openalex.org/keywords/algorithm","display_name":"Algorithm","score":0.1907241940498352},{"id":"https://openalex.org/keywords/engineering","display_name":"Engineering","score":0.17511102557182312},{"id":"https://openalex.org/keywords/electrical-engineering","display_name":"Electrical engineering","score":0.15653666853904724}],"concepts":[{"id":"https://openalex.org/C21200559","wikidata":"https://www.wikidata.org/wiki/Q7451068","display_name":"Sensitivity (control systems)","level":2,"score":0.8063623309135437},{"id":"https://openalex.org/C10558101","wikidata":"https://www.wikidata.org/wiki/Q689855","display_name":"Smart grid","level":2,"score":0.7440224289894104},{"id":"https://openalex.org/C41008148","wikidata":"https://www.wikidata.org/wiki/Q21198","display_name":"Computer science","level":0,"score":0.7209110260009766},{"id":"https://openalex.org/C2780598303","wikidata":"https://www.wikidata.org/wiki/Q65921492","display_name":"Flexibility (engineering)","level":2,"score":0.7150094509124756},{"id":"https://openalex.org/C187691185","wikidata":"https://www.wikidata.org/wiki/Q2020720","display_name":"Grid","level":2,"score":0.6695663332939148},{"id":"https://openalex.org/C200601418","wikidata":"https://www.wikidata.org/wiki/Q2193887","display_name":"Reliability engineering","level":1,"score":0.49510636925697327},{"id":"https://openalex.org/C9652623","wikidata":"https://www.wikidata.org/wiki/Q190109","display_name":"Field (mathematics)","level":2,"score":0.4776909649372101},{"id":"https://openalex.org/C14036430","wikidata":"https://www.wikidata.org/wiki/Q3736076","display_name":"Function (biology)","level":2,"score":0.45623019337654114},{"id":"https://openalex.org/C48103436","wikidata":"https://www.wikidata.org/wiki/Q599031","display_name":"State (computer science)","level":2,"score":0.42982667684555054},{"id":"https://openalex.org/C120314980","wikidata":"https://www.wikidata.org/wiki/Q180634","display_name":"Distributed computing","level":1,"score":0.42602774500846863},{"id":"https://openalex.org/C133731056","wikidata":"https://www.wikidata.org/wiki/Q4917288","display_name":"Control engineering","level":1,"score":0.36063066124916077},{"id":"https://openalex.org/C79403827","wikidata":"https://www.wikidata.org/wiki/Q3988","display_name":"Real-time computing","level":1,"score":0.344099223613739},{"id":"https://openalex.org/C24326235","wikidata":"https://www.wikidata.org/wiki/Q126095","display_name":"Electronic engineering","level":1,"score":0.33807286620140076},{"id":"https://openalex.org/C11413529","wikidata":"https://www.wikidata.org/wiki/Q8366","display_name":"Algorithm","level":1,"score":0.1907241940498352},{"id":"https://openalex.org/C127413603","wikidata":"https://www.wikidata.org/wiki/Q11023","display_name":"Engineering","level":0,"score":0.17511102557182312},{"id":"https://openalex.org/C119599485","wikidata":"https://www.wikidata.org/wiki/Q43035","display_name":"Electrical engineering","level":1,"score":0.15653666853904724},{"id":"https://openalex.org/C78458016","wikidata":"https://www.wikidata.org/wiki/Q840400","display_name":"Evolutionary biology","level":1,"score":0.0},{"id":"https://openalex.org/C2524010","wikidata":"https://www.wikidata.org/wiki/Q8087","display_name":"Geometry","level":1,"score":0.0},{"id":"https://openalex.org/C202444582","wikidata":"https://www.wikidata.org/wiki/Q837863","display_name":"Pure mathematics","level":1,"score":0.0},{"id":"https://openalex.org/C86803240","wikidata":"https://www.wikidata.org/wiki/Q420","display_name":"Biology","level":0,"score":0.0},{"id":"https://openalex.org/C105795698","wikidata":"https://www.wikidata.org/wiki/Q12483","display_name":"Statistics","level":1,"score":0.0},{"id":"https://openalex.org/C33923547","wikidata":"https://www.wikidata.org/wiki/Q395","display_name":"Mathematics","level":0,"score":0.0}],"mesh":[],"locations_count":1,"locations":[{"id":"doi:10.1109/isgteurope.2018.8571862","is_oa":false,"landing_page_url":"https://doi.org/10.1109/isgteurope.2018.8571862","pdf_url":null,"source":null,"license":null,"license_id":null,"version":"publishedVersion","is_accepted":true,"is_published":true,"raw_source_name":"2018 IEEE PES Innovative Smart Grid Technologies Conference Europe (ISGT-Europe)","raw_type":"proceedings-article"}],"best_oa_location":null,"sustainable_development_goals":[{"display_name":"Affordable and clean energy","id":"https://metadata.un.org/sdg/7","score":0.7099999785423279}],"awards":[],"funders":[],"has_content":{"grobid_xml":false,"pdf":false},"content_urls":null,"referenced_works_count":12,"referenced_works":["https://openalex.org/W2043556232","https://openalex.org/W2072305550","https://openalex.org/W2106424475","https://openalex.org/W2142055017","https://openalex.org/W2183972878","https://openalex.org/W2567275013","https://openalex.org/W2591677329","https://openalex.org/W2769249957","https://openalex.org/W2783625044","https://openalex.org/W6686056686","https://openalex.org/W6745960978","https://openalex.org/W7038227445"],"related_works":["https://openalex.org/W4236696095","https://openalex.org/W3143779693","https://openalex.org/W2626808643","https://openalex.org/W2004064826","https://openalex.org/W3103727510","https://openalex.org/W97045569","https://openalex.org/W2751256511","https://openalex.org/W1527069879","https://openalex.org/W2946179579","https://openalex.org/W2348021072"],"abstract_inverted_index":{"The":[0,106,123],"upcoming":[1],"changes":[2],"in":[3,55,91,129],"the":[4,9,37,41,45,56,58,83,88,97,103,114,142],"electrical":[5],"power":[6],"supply":[7],"increase":[8],"challenges":[10],"for":[11,44],"grid":[12,89,137],"operators.":[13],"Smart":[14,136],"Grid":[15],"Systems":[16],"are":[17,31,53,134,144],"being":[18],"developed":[19],"and":[20,36,131],"further":[21],"applications":[22,66],"e.g.":[23],"adaptivity,":[24],"market":[25],"integration":[26],"or":[27],"holistic":[28],"flexibility":[29],"provision":[30],"incorporated.":[32],"All":[33],"these":[34],"functions":[35,138],"increasing":[38],"complexity":[39],"raise":[40],"computational":[42,59],"effort":[43],"used":[46,54],"hardware.":[47],"Especially":[48],"if":[49],"remote":[50],"terminal":[51],"units":[52],"field":[57],"performance":[60],"is":[61,127],"limited.":[62],"A":[63],"lot":[64],"of":[65,102,121],"need":[67],"a":[68,77,92,118],"load":[69,79,107],"flow":[70,80,108],"estimation":[71],"which":[72,139],"can":[73,86,110],"be":[74,111],"done":[75],"by":[76,113],"conventional":[78],"calculation.":[81],"Also":[82],"sensitivity":[84,104,125],"analysis":[85,126],"estimate":[87],"state":[90],"more":[93],"efficient":[94],"way.":[95],"Therefore,":[96],"paper":[98],"presents":[99],"an":[100],"improvement":[101,143],"analysis:":[105],"calculation":[109],"substituted":[112],"new":[115],"function":[116],"without":[117],"significant":[119],"loss":[120],"accuracy.":[122],"improved":[124],"demonstrated":[128],"detail":[130],"precision":[132],"tests":[133],"shown.":[135],"benefit":[140],"from":[141],"introduced,":[145],"too.":[146]},"counts_by_year":[{"year":2020,"cited_by_count":1}],"updated_date":"2025-11-06T03:46:38.306776","created_date":"2025-10-10T00:00:00"}
